{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T18:55:10Z","timestamp":1775156110531,"version":"3.50.1"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>Prospective, multicenter study on cadaveric models and patients undergoing L4\u20135 decompression and interspinous fixation device (IFD) placement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To validate the intraoperative pull-up strength of the InSpan (InSpan LLC, Burlington, MA) IFD as a standalone device, assessing its immediate and long-term stability.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>Interspinous fixation devices (IFDs) are used in spinal stenosis treatment and fusion procedures to distract the disc and foraminal space, providing posterior stabilization. Despite their utility, concerns about spinous process fractures and implant loosening persist.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A total of 50 cases, including 29 cadavers (group 1) and 21 patients (group 2), underwent L4\u20135 decompression with InSpan IFD placement. Over 6 months, 21 patients were consecutively enrolled at 3 sites, treated by interventional pain management and spine surgeons, with 100% recruitment. Implant stability was tested intraoperatively using a thumb-index finger pull test, followed by a body lift-off pull-up test, with confirmation through physical and fluoroscopic evaluation. Patients were followed for up to 24 months, and outcome measures such as the Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) scores, implant failure, and revision rates were recorded.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      All 29 cadavers in group 1 passed the pull-up tests without implant loosening. In group 2, 95% (20\/21) of primary IFD surgeries passed on the first attempt, whereas 1 revision case failed the body lift-up test and required further decompression. Two-year follow-up for 14 patients showed significant improvements in VAS (79.44%) and ODI (68.56%) scores (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.001). Radiographic assessments confirmed stable implants with no loosening or fractures. Males had longer surgery times (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      &lt;0.05), but outcomes were similar across genders.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The InSpan IFD provides significant immediate and long-term stability. The pull-up test is a reliable method to assess intraoperative fixation, with potential applications in suspected inadequate fixation cases.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Level of Evidence:<\/jats:title>\n                    <jats:p>Level III.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000002052","type":"journal-article","created":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T18:00:50Z","timestamp":1775152850000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Validation of Intraoperative Pull-Up Strength Testing of an Interspinous Fixation Device for Immediate and Long-Term Clinical Stability"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1378-1697","authenticated-orcid":false,"given":"Kingsley R.","family":"Chin","sequence":"first","affiliation":[{"name":"Less Exposure Surgery Specialists Institute (LESS Institute; LESS Clinic), Fort Lauderdale"},{"name":"Department of Orthopedics, Herbert Wertheim College of Medicine at Florida International University, Miami"},{"name":"Less Exposure Spine Surgery (LESS) Society 501(c)(3), Fort Lauderdale, FL"},{"name":"Faculty of Science and Sports, University of Technology, Kingston, Jamaica, West Indies"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark","family":"Jones","sequence":"additional","affiliation":[{"name":"Pain Medicine of the South, Knoxville, TN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sandra","family":"Thompson","sequence":"additional","affiliation":[{"name":"The Pain Center, Boise, ID"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Pannozzo","sequence":"additional","affiliation":[{"name":"Summa Pain Care, Scottsdale, AZ"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soubrata V.","family":"Raikar","sequence":"additional","affiliation":[{"name":"Midwest Anesthesia and Pain Management, Fremont, NE"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yeshvant A.","family":"Navalgund","sequence":"additional","affiliation":[{"name":"National Spine and Pain Centers, Glen Burnie, MD"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Steven","family":"Siwek","sequence":"additional","affiliation":[{"name":"The Pain Center of Arizona, Phoenix, AZ"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sachin","family":"Narain","sequence":"additional","affiliation":[{"name":"The Pain Center of Arizona, Gilbert, AZ"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luis","family":"Fandos","sequence":"additional","affiliation":[{"name":"National Spine and Pain Centers, Bay Shore"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rajmani","family":"Krishnan","sequence":"additional","affiliation":[{"name":"Island Interventional Pain Management, Commack, NY"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Paul","family":"Ky","sequence":"additional","affiliation":[{"name":"Advanced Pain Solutions, Fresno"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Glade","family":"Roper","sequence":"additional","affiliation":[{"name":"VIP Specialists, Visalia, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tian","family":"Xia","sequence":"additional","affiliation":[{"name":"Integrated Pain Management, Chicago, IL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erik","family":"Spayde","sequence":"additional","affiliation":[{"name":"St. Charles Spine Institute, Thousand Oaks"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William M.","family":"Costigan","sequence":"additional","affiliation":[{"name":"Congress Orthopedic Associates, Pasadena, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Vito","family":"Lore","sequence":"additional","affiliation":[{"name":"LESSpine, Burlington, MA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Angel","family":"Walker","sequence":"additional","affiliation":[{"name":"Less Exposure Spine Surgery (LESS) Society 501(c)(3), Fort Lauderdale, FL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hope","family":"Estevez","sequence":"additional","affiliation":[{"name":"Less Exposure Surgery Specialists Institute (LESS Institute; LESS Clinic), Fort Lauderdale"},{"name":"Less Exposure Spine Surgery (LESS) Society 501(c)(3), Fort Lauderdale, FL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jason A.","family":"Seale","sequence":"additional","affiliation":[{"name":"Less Exposure Surgery Specialists Institute (LESS Institute; LESS Clinic), Fort Lauderdale"},{"name":"Less Exposure Spine Surgery (LESS) Society 501(c)(3), Fort Lauderdale, FL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chukwunonso C.","family":"Ilogu","sequence":"additional","affiliation":[{"name":"Less Exposure Surgery Specialists Institute (LESS Institute; LESS Clinic), Fort Lauderdale"},{"name":"Less Exposure Spine Surgery (LESS) Society 501(c)(3), Fort Lauderdale, FL"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2026,3,30]]},"reference":[{"key":"R1-20260402","doi-asserted-by":"crossref","first-page":"802","DOI":"10.2106\/00004623-199173060-00002","article-title":"Degenerative lumbar spondylolisthesis with spinal stenosis. A prospective study comparing decompression with decompression and intertransverse process arthrodesis","volume":"73","author":"Herkowitz","year":"1991","journal-title":"J Bone Joint Surg Am"},{"key":"R2-20260402","doi-asserted-by":"crossref","first-page":"983","DOI":"10.1097\/00007632-199306150-00006","article-title":"A prospective, randomized study of lumbar fusion. Preliminary results","volume":"18","author":"Zdeblick","year":"1993","journal-title":"Spine"},{"key":"R3-20260402","doi-asserted-by":"crossref","first-page":"860","DOI":"10.3171\/jns.1992.77.6.0860","article-title":"Transpedicular screw-rod fixation of the lumbar spine: operative technique and outcome in 104 cases","volume":"77","author":"Dickman","year":"1992","journal-title":"J Neurosurg"},{"key":"R4-20260402","doi-asserted-by":"crossref","first-page":"1082","DOI":"10.1016\/j.spinee.2017.04.002","article-title":"Comparison of minimally invasive spine surgery using intraoperative computed tomography integrated navigation, fluoroscopy, and conventional open surgery for lumbar spondylolisthesis: a prospective registry-based cohort study","volume":"17","author":"Wu","year":"2017","journal-title":"Spine J"},{"issue":"suppl 2","key":"R5-20260402","first-page":"163","article-title":"Risk factors for adjacent-segment failure following lumbar fixation with rigid instrumentation for degenerative instability","volume":"90","author":"Etebar","year":"1999","journal-title":"J Neurosurg"},{"key":"R6-20260402","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1186\/s13018-023-03838-x","article-title":"Fixation-induced surgical segment\u2019s high stiffness and the damage of posterior structures together trigger a higher risk of adjacent segment disease in patients with lumbar interbody fusion operations","volume":"18","author":"Cai","year":"2023","journal-title":"J Orthop Surg Res"},{"key":"R7-20260402","doi-asserted-by":"crossref","first-page":"e1112","DOI":"10.1016\/j.wneu.2019.04.051","article-title":"Biomechanical analysis of different lumbar interspinous process devices: a finite element study","volume":"127","author":"Shen","year":"2019","journal-title":"World Neurosurg"},{"key":"R8-20260402","doi-asserted-by":"crossref","first-page":"2079","DOI":"10.2147\/JPR.S453343","article-title":"24-Month outcomes of indirect decompression using a minimally invasive interspinous fixation device versus standard open direct decompression for lumbar spinal stenosis: a prospective comparison","volume":"17","author":"Baranidharan","year":"2024","journal-title":"J Pain Res"},{"key":"R9-20260402","doi-asserted-by":"crossref","first-page":"975052","DOI":"10.1155\/2014\/975052","article-title":"Controversies about interspinous process devices in the treatment of degenerative lumbar spine diseases: past, present, and future","volume":"2014","author":"Gazzeri","year":"2014","journal-title":"Biomed Res Int"},{"key":"R10-20260402","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s12178-017-9401-z","article-title":"Interspinous implants: are the new implants better than the last generation? A review","volume":"10","author":"Pintauro","year":"2017","journal-title":"Curr Rev Musculoskelet Med"},{"key":"R11-20260402","doi-asserted-by":"crossref","first-page":"132","DOI":"10.3171\/spi.2006.4.2.132","article-title":"Comparison of CD HORIZON SPIRE spinous process plate stabilization and pedicle screw fixation after anterior lumbar interbody fusion. Invited submission from the Joint Section Meeting On Disorders of the Spine and Peripheral Nerves, March 2005","volume":"4","author":"Wang","year":"2006","journal-title":"J Neurosurg Spine"},{"key":"R12-20260402","doi-asserted-by":"crossref","first-page":"386","DOI":"10.21037\/jss-24-13","article-title":"Advancing the design of interspinous fixation devices for improved biomechanical performance: dual vs. single-locking set screw mechanisms and symmetrical vs. asymmetrical plate designs","volume":"10","author":"Chin","year":"2024","journal-title":"J Spine Surg"},{"key":"R13-20260402","doi-asserted-by":"crossref","first-page":"398","DOI":"10.21037\/jss-23-49","article-title":"Prospective 5-year follow-up of L5-S1 versus L4-5 midline decompression and interspinous-interlaminar fixation as a stand-alone treatment for spinal stenosis compared with laminectomies","volume":"9","author":"Chin","year":"2023","journal-title":"J Spine Surg"},{"key":"R14-20260402","doi-asserted-by":"crossref","first-page":"549","DOI":"10.21037\/jss-20-547","article-title":"Greater than 5-year follow-up of outpatient L4-L5 lumbar interspinous fixation for degenerative spinal stenosis using the INSPAN device","volume":"6","author":"Chin","year":"2020","journal-title":"J Spine Surg"},{"key":"R15-20260402","first-page":"e19956","article-title":"Inter spinal fixation and stabilization device for lumbar radiculopathy and back pain","volume":"13","author":"Raikar","year":"2021","journal-title":"Cureus"},{"key":"R16-20260402","doi-asserted-by":"crossref","first-page":"E1279","DOI":"10.1097\/BSD.0000000000000411","article-title":"Lumbar spinous process fixation and fusion: a systematic review and critical analysis of an emerging spinal technology","volume":"30","author":"Lopez","year":"2017","journal-title":"Clin Spine Surg"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000002052","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,2]],"date-time":"2026-04-02T18:00:53Z","timestamp":1775152853000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000002052"}},"subtitle":["A Cadaveric and Prospective Clinical Study"],"short-title":[],"issued":{"date-parts":[[2026,3,30]]},"references-count":16,"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000002052","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3,30]]},"assertion":[{"value":"2024-10-16","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-01-26","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}