{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T22:09:31Z","timestamp":1779919771360,"version":"3.53.1"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","license":[{"start":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T00:00:00Z","timestamp":1779840000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>Study Design:<\/jats:title>\n                    <jats:p>This is a finite element biomechanical analysis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective:<\/jats:title>\n                    <jats:p>To evaluate the optimal injection dose and distribution of bone cement in vertebroplasty using the finite element method.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Summary of Background Data:<\/jats:title>\n                    <jats:p>In the treatment of osteoporotic lumbar compression fractures, PVP (percutaneous vertebroplasty) is widely used. Although this surgical method can effectively relieve pain and improve the quality of life of patients in many cases, there are still some patients who have unsatisfactory results. This may be related to factors such as the distribution of bone cement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and Methods:<\/jats:title>\n                    <jats:p>CT data of 1 patient with an L1 fracture were extracted to construct the thoracolumbar (T12\u2013L2) fracture model. The 4, 6, and 8\u00a0mL bone cement filling models were constructed, and the 4 and 6\u00a0mL models were further divided into lump and discrete types to form 5 different bone cement filling models. All models fully restrained the L2 vertebral base, while 500\u00a0N axial loads were applied to the T12 endplate to simulate body weight, and 10\u00a0Nm torque was applied to simulate the 4 spinal movements of left bend, right rotation, flexion, and extension. The stress values of 5 models under different motion conditions were analyzed and compared with those without bone cement.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>Five finite element models of osteoporotic vertebral compression fractures with different amounts and distributions of bone cement were successfully established. It was found that the Von Mises stress in all parts of the 8\u00a0mL lump bone cement model group was the minimum value in the upright + left bending state. In addition, at the same volume of bone cement, there was no significant difference in stress levels between the lump and discrete bone cement models.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>A 4\u00a0mL of bone cement in percutaneous vertebroplasty does not improve the biomechanical microenvironment of the spine during lumbar arthroplasty. We need to inject as much bone cement as possible, and if there are signs of leakage, the injection should be stopped immediately.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/bsd.0000000000002091","type":"journal-article","created":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T22:00:10Z","timestamp":1779919210000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Optimal Dosage and Distribution of Bone Cement in Vertebroplasty"],"prefix":"10.1097","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5772-4830","authenticated-orcid":false,"given":"Gong","family":"Yao","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Cai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhijian","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,5,27]]},"reference":[{"key":"R1-20260527","first-page":"E33","article-title":"Risk factors for the occurrence of insufficient cement distribution in the fractured area after percutaneous vertebroplasty in osteoporotic vertebral compression fractures","volume":"21","author":"Ye","year":"2016","journal-title":"Pain Physician"},{"key":"R2-20260527","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.21037\/apm-20-955","article-title":"Three-dimensional finite element analysis of optimal distribution model of vertebroplasty","volume":"9","author":"Wang","year":"2020","journal-title":"Ann Palliat Med"},{"key":"R3-20260527","doi-asserted-by":"crossref","first-page":"56","DOI":"10.13004\/kjnt.2022.18.e13","article-title":"A comparative study on the treatment of osteoporotic vertebral compression fractures with early ambulation and at least 1 week of absolute bed rest","volume":"18","author":"Kim","year":"2022","journal-title":"Korean J Neurotrauma"},{"key":"R4-20260527","first-page":"697","article-title":"The conservative treatment of traumatic thoracolumbar vertebral fractures","volume":"115","author":"Spiegl","year":"2018","journal-title":"Dtsch Arztebl Int"},{"key":"R5-20260527","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1007\/s00198-019-05101-8","article-title":"Percutaneous vertebroplasty versus non-operative treatment for osteoporotic vertebral compression fractures: a meta-analysis of randomized controlled trials","volume":"30","author":"Lou","year":"2019","journal-title":"Osteoporos Int"},{"key":"R6-20260527","first-page":"732","article-title":"Biomechanical effects of different bone cement diffusion patterns after vertebroplasty: finite element analysis [Chinese]","volume":"34","author":"Yao","year":"2021","journal-title":"Zhongguo Gu Shang"},{"key":"R7-20260527","doi-asserted-by":"crossref","first-page":"2718","DOI":"10.1007\/s00586-014-3379-7","article-title":"Effect of vertebroplasty with bone filler device and comparison with balloon kyphoplasty","volume":"23","author":"Yang","year":"2014","journal-title":"Eur Spine J"},{"key":"R8-20260527","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1097\/01.BRS.0000061987.71624.17","article-title":"The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis","volume":"28","author":"Polikeit","year":"2003","journal-title":"Spine"},{"key":"R9-20260527","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1097\/00007632-200107150-00009","article-title":"Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty","volume":"26","author":"Liebschner","year":"2001","journal-title":"Spine"},{"key":"R10-20260527","doi-asserted-by":"crossref","first-page":"1549","DOI":"10.1097\/01.BRS.0000076831.38265.8D","article-title":"The effect of vertebral body percentage fill on mechanical behavior during percutaneous vertebroplasty","volume":"28","author":"Molloy","year":"2003","journal-title":"Spine"},{"key":"R11-20260527","doi-asserted-by":"crossref","first-page":"e140","DOI":"10.1016\/j.wneu.2023.02.021","article-title":"Unsubtracted roadmap technique for preventing cement leakage during percutaneous vertebroplasty: a retrospective cohort study","volume":"173","author":"Kim","year":"2023","journal-title":"World Neurosurg"},{"key":"R12-20260527","doi-asserted-by":"crossref","first-page":"246","DOI":"10.1016\/j.jss.2014.12.053","article-title":"Biomechanical effects of cement distribution in the fractured area on osteoporotic vertebral compression fractures: a three-dimensional finite element analysis","volume":"195","author":"Liang","year":"2015","journal-title":"J Surg Res"},{"key":"R13-20260527","doi-asserted-by":"crossref","first-page":"621","DOI":"10.1186\/s12891-022-05522-3","article-title":"A finite element analysis on different bone cement forms and injection volumes injected into lumbar vertebral body in percutaneous kyphoplasty","volume":"23","author":"Zhang","year":"2022","journal-title":"BMC Musculoskelet Disord"},{"key":"R14-20260527","first-page":"166","article-title":"Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty [French]","volume":"33","author":"Galibert","year":"1987","journal-title":"Neurochirurgie"},{"key":"R15-20260527","doi-asserted-by":"crossref","first-page":"e828","DOI":"10.1016\/j.wneu.2022.12.117","article-title":"Systematic retrospective analysis of risk factors and preventive measures of bone cement leakage in percutaneous kyphoplasty","volume":"171","author":"Li","year":"2023","journal-title":"World Neurosurg"},{"key":"R16-20260527","doi-asserted-by":"crossref","first-page":"214","DOI":"10.3390\/healthcare10020214","article-title":"Application of Machine Learning in Developing Decision-Making Support Models for Decompressed Vertebroplasty.","volume":"10","author":"Liao","year":"2022","journal-title":"Healthcare (Basel)"},{"key":"R17-20260527","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1097\/00007632-200107150-00007","article-title":"The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior","volume":"26","author":"Belkoff","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R18-20260527","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1186\/s12891-022-05135-w","article-title":"Correlation analysis of the puncture-side bone cement\/vertebral body volume ratio and bone cement leakage in the paravertebral vein in vertebroplasty","volume":"23","author":"Gao","year":"2022","journal-title":"BMC Musculoskelet Disord"},{"key":"R19-20260527","doi-asserted-by":"crossref","first-page":"e5675","DOI":"10.1097\/MD.0000000000005675","article-title":"Risk factors for recollapse of the augmented vertebrae after percutaneous vertebroplasty for osteoporotic vertebral fractures with intravertebral vacuum cleft","volume":"96","author":"Yu","year":"2017","journal-title":"Medicine (Baltimore)"},{"key":"R20-20260527","doi-asserted-by":"crossref","first-page":"e31829","DOI":"10.1016\/j.heliyon.2024.e31829","article-title":"Assessment of the accuracy of 3D printed medical models through reverse engineering","volume":"10","author":"Wakjira","year":"2024","journal-title":"Heliyon"},{"key":"R21-20260527","doi-asserted-by":"crossref","first-page":"301","DOI":"10.3109\/17453677208998949","article-title":"A new method to analyse the mechanical behaviour of skeletal parts","volume":"43","author":"Brekelmans","year":"1972","journal-title":"Acta Orthop Scand"},{"key":"R22-20260527","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1016\/0021-9290(73)90096-1","article-title":"Analog studies of forces in the human spine: computational techniques","volume":"6","author":"Belytschko","year":"1973","journal-title":"J Biomech"},{"key":"R23-20260527","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1080\/03091902.2022.2026502","article-title":"Reconstruction of the artificial knee joint using a reverse engineering approach based on computer-aided design","volume":"46","author":"Darmanto","year":"2022","journal-title":"J Med Eng Technol"},{"key":"R24-20260527","doi-asserted-by":"crossref","first-page":"43","DOI":"10.3390\/jfb12030043","article-title":"Finite element method for the evaluation of the human spine: a literature overview","volume":"12","author":"Naoum","year":"2021","journal-title":"J Funct Biomater"}],"container-title":["Clinical Spine Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000002091","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,27]],"date-time":"2026-05-27T22:00:13Z","timestamp":1779919213000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BSD.0000000000002091"}},"subtitle":["A Finite Element Analysis"],"short-title":[],"issued":{"date-parts":[[2026,5,27]]},"references-count":24,"URL":"https:\/\/doi.org\/10.1097\/bsd.0000000000002091","relation":{},"ISSN":["2380-0186","2380-0194"],"issn-type":[{"value":"2380-0186","type":"print"},{"value":"2380-0194","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,27]]},"assertion":[{"value":"2025-02-09","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-22","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}