{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,18]],"date-time":"2026-10-18T20:53:32Z","timestamp":1792356812825,"version":"4.4.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2007,5]]},"DOI":"10.1097\/bsd.0b013e318030d2f3","type":"journal-article","created":{"date-parts":[[2007,5,1]],"date-time":"2007-05-01T04:02:50Z","timestamp":1177992170000},"page":"248-254","source":"Crossref","is-referenced-by-count":17,"title":["Early Failure of Bioabsorbable Anterior Cervical Fusion Plates"],"prefix":"10.1097","volume":"20","author":[{"given":"Mario","family":"Brkaric","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kevin C.","family":"Baker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Raj","family":"Israel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Trevor","family":"Harding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David M.","family":"Montgomery","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harry N.","family":"Herkowitz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-13-20210204","doi-asserted-by":"crossref","first-page":"636","DOI":"10.1016\/j.spinee.2004.04.010","article-title":"Does rigid instrumentation increase the fusion rate in one-level anterior cervical discectomy and fusion?","volume":"4","author":"Samartzis","year":"2004","journal-title":"Spine J"},{"key":"R2-13-20210204","doi-asserted-by":"crossref","first-page":"2788","DOI":"10.1097\/01.brs.0000190453.46472.08","article-title":"Does anterior plating of the cervical spine predispose segment changes?","volume":"30","author":"Rao","year":"2005","journal-title":"Spine"},{"key":"R3-13-20210204","doi-asserted-by":"crossref","first-page":"2138","DOI":"10.1097\/01.brs.0000180479.63092.17","article-title":"Long-term results after anterior cervical discectomy and fusion with allograft and plating: a 5 to 11 year radiologic and clinical follow-up","volume":"30","author":"Yue","year":"2005","journal-title":"Spine"},{"key":"R4-13-20210204","first-page":"229","article-title":"Anterior cervical plating enhances arthrodesis after discectomy and fusion with cortical allograft","volume":"50","author":"Kaiser","year":"2002","journal-title":"Neurosurgery"},{"key":"R5-13-20210204","doi-asserted-by":"crossref","first-page":"467","DOI":"10.1097\/00002517-199912000-00003","article-title":"The effect of cervical plating on single-level anterior cervical discectomy and fusion","volume":"12","author":"Wang","year":"1999","journal-title":"J Spinal Disord"},{"key":"R6-13-20210204","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1097\/00007632-200001010-00009","article-title":"Increased fusion rates with cervical plating for two-level anterior cervical discectomy and fusion","volume":"25","author":"Wang","year":"2000","journal-title":"Spine"},{"key":"R7-13-20210204","doi-asserted-by":"crossref","first-page":"643","DOI":"10.1097\/00007632-200103150-00015","article-title":"Increased fusion rates with cervical plating for three-level anterior cervical discectomy and fusion","volume":"26","author":"Wang","year":"2001","journal-title":"Spine"},{"key":"R8-13-20210204","doi-asserted-by":"crossref","first-page":"2706","DOI":"10.1097\/00007632-200212010-00010","article-title":"Bioabsorbable poly-L-lactic acid cages for lumbar interbody fusion","volume":"27","author":"van Dijk","year":"2002","journal-title":"Spine"},{"key":"R9-13-20210204","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1002\/jbm.10466","article-title":"In vitro and in vivo degradation of bioabsorbable poly-L-lactic acid fusion cages","volume":"63","author":"van Dijk","year":"2002","journal-title":"J Biomed Mater Res"},{"key":"R10-13-20210204","doi-asserted-by":"crossref","first-page":"4","DOI":"10.3171\/foc.2004.16.3.5","article-title":"Cervical spine fusion with bioabsorbable cages","volume":"16","author":"Lippman","year":"2004","journal-title":"Neurosurg Focus"},{"key":"R11-13-20210204","doi-asserted-by":"crossref","first-page":"3161","DOI":"10.1016\/S0142-9612(03)00155-8","article-title":"Mechanical evaluation of novel spinal interbody fusion cages made of bioactive, resorbable composites","volume":"24","author":"Shikinami","year":"2003","journal-title":"Biomaterials"},{"key":"R12-13-20210204","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1177\/230949900100900117","article-title":"Polyethylene wear and osteolysis in total hip arthroplasty","volume":"9","author":"Zhu","year":"2001","journal-title":"J Orthop Surg"},{"key":"R13-13-20210204","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/01.blo.0000196044.42413.c7","article-title":"Osteolysis caused by tibial component in total knee arthroplasty","volume":"443","author":"Cheng","year":"2006","journal-title":"Clin Orthop Relat Res"},{"issue":"suppl","key":"R15-13-20210204","first-page":"473","article-title":"Use of a bioabsorbable anterior cervical plate in the treatment of cervical degenerative and traumatic disc disruption","volume":"97","author":"Vaccaro","year":"2002","journal-title":"J Nerosurg"},{"key":"R16-13-20210204","doi-asserted-by":"crossref","first-page":"631","DOI":"10.1227\/01.NEU.0000108942.07872.2A","article-title":"Stabilization of anterior cervical spine with bioabsorbable polymer in one- and two-level fusions","volume":"54","author":"Park","year":"2004","journal-title":"Neurosurgery"},{"key":"R17-13-20210204","doi-asserted-by":"crossref","first-page":"850","DOI":"10.1097\/01.PRS.0000132856.69391.43","article-title":"Resorbable PLLA-PGA plate and screw fixation in pediatric craniofacial surgery: clinical experience in 1883 patients","volume":"114","author":"Eppley","year":"2004","journal-title":"Plast Reconstr Surg"},{"key":"R18-13-20210204","doi-asserted-by":"crossref","first-page":"1281","DOI":"10.1053\/jpsu.2002.34983","article-title":"Treatment of pectus excavatum with bioabsorbale polylactide plates: preliminary results","volume":"27","author":"Lansman","year":"2002","journal-title":"J Pediatr Surg"},{"key":"R19-13-20210204","doi-asserted-by":"crossref","first-page":"26","DOI":"10.2106\/00004623-200201000-00005","article-title":"Treatment of syndesmotic disruptions of the ankle with bioabsorbable screw fixation","volume":"84-A","author":"Hovis","year":"2002","journal-title":"J Bone Joint Surg Am"},{"key":"R20-13-20210204","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1067\/mse.2003.16","article-title":"Failure of polymerized lactic acid tacks in shoulder surgery","volume":"12","author":"Wilkerson","year":"2003","journal-title":"J Shoulder Elbow Surg"},{"key":"R21-13-20210204","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1053\/jars.2002.32197","article-title":"Broken poly-L-lactic acid interference screw after ligament reconstruction","volume":"18","author":"Shafer","year":"2002","journal-title":"Arthroscopy"},{"key":"R22-13-20210204","doi-asserted-by":"crossref","first-page":"33","DOI":"10.2106\/00004623-200412002-00006","article-title":"Increasing patient safety and orthopaedic device quality via adverse event reporting mechanisms","volume":"86","author":"Tanner","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R23-13-20210204","article-title":"Fundamentals of Materials Science and Engineering","author":"Callister","year":"2001"},{"key":"R24-13-20210204","article-title":"Mechanical Behavior of Materials","author":"Meyers","year":"1999"},{"key":"R25-13-20210204","article-title":"Fractography","volume":"12","year":"1987"},{"key":"R26-13-20210204","article-title":"Fracture Mechanics","author":"Anderson","year":"1995"},{"key":"R27-13-20210204","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1002\/jbm.1067","article-title":"Resorbable polymer fibers for ligament augmentation","volume":"58","author":"Durselen","year":"2001","journal-title":"J Biomed Mater Res B Appl Biomater"}],"container-title":["Journal of Spinal Disorders &amp; Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BSD.0b013e318030d2f3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T16:34:24Z","timestamp":1786034064000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00024720-200705000-00013"}},"subtitle":["Case Report and Failure Analysis"],"short-title":[],"issued":{"date-parts":[[2007,5]]},"references-count":26,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2007]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0b013e318030d2f3","relation":{},"ISSN":["1536-0652"],"issn-type":[{"value":"1536-0652","type":"print"}],"subject":[],"published":{"date-parts":[[2007,5]]}}}