{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,7]],"date-time":"2026-08-07T16:31:01Z","timestamp":1786120261882,"version":"build-2736575974"},"reference-count":20,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2013,5]]},"DOI":"10.1097\/bsd.0b013e31823d36b6","type":"journal-article","created":{"date-parts":[[2011,11,19]],"date-time":"2011-11-19T04:17:39Z","timestamp":1321676259000},"page":"127-134","source":"Crossref","is-referenced-by-count":53,"title":["Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for C1 Lateral Mass and C2 Pedicle Screw Placement for Atlantoaxial Instability"],"prefix":"10.1097","volume":"26","author":[{"given":"Yong Liang","family":"Yang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong Sheng","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ji Liang","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-2-20210204","doi-asserted-by":"crossref","first-page":"279","DOI":"10.2106\/00004623-197860030-00001","article-title":"Atlanto-axial arthrodesis by the wedge compression method.","volume":"60","author":"Brooks","year":"1978","journal-title":"J Bone Joint Surg Am"},{"key":"R2-2-20210204","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1097\/00000658-193710000-00026","article-title":"Skeletal traction in the treatment of fractures and dislocations of the cervical spine.","volume":"106","author":"Gallie","year":"1937","journal-title":"Ann Surg"},{"key":"R3-2-20210204","doi-asserted-by":"crossref","first-page":"318","DOI":"10.1227\/00006123-198403000-00010","article-title":"Posterior stabilization with an interlaminar clamp in cervical injuries: technical note and review of the long term experience with the method.","volume":"14","author":"Holness","year":"1984","journal-title":"Neurosurgery"},{"key":"R4-2-20210204","first-page":"46","article-title":"Surgical stabilization of C1 and C2 fractures.","volume":"16","author":"Grob","year":"1987","journal-title":"Orthopade"},{"key":"R6-2-20210204","doi-asserted-by":"crossref","first-page":"961","DOI":"10.3171\/jns.1997.86.6.0961","article-title":"Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique.","volume":"86","author":"Madawi","year":"1997","journal-title":"J Neurosurg"},{"key":"R12-2-20210204","doi-asserted-by":"crossref","first-page":"2081","DOI":"10.2106\/00004623-200409000-00032","article-title":"Fractures of the odontoid process of the axis. 1974.","volume":"86-A","author":"Anderson","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R13-2-20210204","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/BSD.0b013e31805777da","article-title":"Odontoid screw placement using isocentric 3-dimensional C-arm fluoroscopy.","volume":"21","author":"Summers","year":"2008","journal-title":"J Spinal Disord Tech"},{"key":"R14-2-20210204","doi-asserted-by":"crossref","first-page":"1592","DOI":"10.1016\/j.jocn.2009.03.026","article-title":"Posterior C1 lateral mass and C2 pedicle screw internal fixation for atlantoaxial instability.","volume":"16","author":"Xie","year":"2009","journal-title":"J Clin Neurosci"},{"key":"R15-2-20210204","first-page":"2995","article-title":"Comparison of the clinical accuracy of cervical (C2-C7) pedicle screw insertion assisted by fluoroscopy, computed tomography-based navigation, and intraoperative three-dimensional C-arm navigation.","volume":"123","author":"Liu","year":"2010","journal-title":"Chin Med J (Engl)"},{"key":"R16-2-20210204","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1007\/BF01400872","article-title":"Plate and screw fixation for atlanto-axial subluxation.","volume":"129","author":"Goel","year":"1994","journal-title":"Acta Neurochir (Wien)"},{"key":"R18-2-20210204","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.spinee.2006.08.010","article-title":"Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques.","volume":"7","author":"Claybrooks","year":"2007","journal-title":"Spine J"},{"key":"R20-2-20210204","first-page":"257","article-title":"Improved accuracy of computer-assisted cervical pedicle screw insertion.","volume":"99","author":"Kotani","year":"2003","journal-title":"J Neurosurg"},{"key":"R21-2-20210204","doi-asserted-by":"crossref","first-page":"809","DOI":"10.1007\/s00586-010-1291-3","article-title":"Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation.","volume":"19","author":"Mueller","year":"2010","journal-title":"Eur Spine J"},{"key":"R22-2-20210204","doi-asserted-by":"crossref","first-page":"722","DOI":"10.1016\/j.wneu.2010.02.067","article-title":"Long-term results of computer-assisted posterior occipitocervical reconstruction.","volume":"73","author":"Ogihara","year":"2010","journal-title":"World Neurosurg"},{"key":"R23-2-20210204","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1080\/10790268.2008.11753648","article-title":"Comparison of radiation exposure in lumbar pedicle screw placement with fluoroscopy vs computer-assisted image guidance with intraoperative three-dimensional imaging.","volume":"31","author":"Smith","year":"2008","journal-title":"J Spinal Cord Med"},{"key":"R24-2-20210204","doi-asserted-by":"crossref","first-page":"1833","DOI":"10.1007\/s11999-008-0632-6","article-title":"Computer-navigated iliosacral screw insertion reduces malposition rate and radiation exposure.","volume":"467","author":"Zwingmann","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"R25-2-20210204","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1302\/0301-620X.89B3.18424","article-title":"Accuracy analysis of Iso-C3D versus fluoroscopy-based navigated retrograde drilling of osteochondral lesions: a pilot study.","volume":"89","author":"Citak","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"R26-2-20210204","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1007\/s00586-005-0992-5","article-title":"Computer-assisted screw insertion into the first sacral vertebra using a three-dimensional image intensifier: results of a controlled experimental investigation.","volume":"15","author":"Briem","year":"2006","journal-title":"Eur Spine J"},{"issue":"suppl 1","key":"R28-2-20210204","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.injury.2004.05.014","article-title":"Computer aided tumor resection in the pelvis.","volume":"35","author":"Krettek","year":"2004","journal-title":"Injury"},{"key":"R29-2-20210204","doi-asserted-by":"crossref","first-page":"1899","DOI":"10.1007\/s00586-011-1860-0","article-title":"Anterior single screw fixation of odontoid fracture with intraoperative iso-C 3-dimensional imaging.","volume":"20","author":"Yang","year":"2011","journal-title":"Eur Spine J"}],"container-title":["Journal of Spinal Disorders &amp; Techniques"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/BSD.0b013e31823d36b6","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,6]],"date-time":"2026-08-06T20:23:36Z","timestamp":1786047816000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/00024720-201305000-00002"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,5]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2013]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0b013e31823d36b6","relation":{},"ISSN":["1536-0652"],"issn-type":[{"value":"1536-0652","type":"print"}],"subject":[],"published":{"date-parts":[[2013,5]]}}}