{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,26]],"date-time":"2025-10-26T22:51:04Z","timestamp":1761519064012},"reference-count":17,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,2]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>An in vitro biomechanical study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>To determine the fracture reduction achieved by a novel inflatable bone tamp under simulated physiological load.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>Previous biomechanical studies have showed that kyphoplasty allows near-total restoration of lost vertebral height in unloaded conditions and partial height restoration under simulated physiological loads. Clinically, loss of reduction has been observed after bone tamp deflation, before cement injection. The present study evaluated fracture reduction achieved by an inflatable bone tamp during kyphoplasty while maintaining physiological load. Comparison to commercially available inflatable bone tamp was also performed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Materials and Methods:<\/jats:title>\n            <jats:p>Eighteen osteoporotic vertebral bodies (T11\u2013L4) were alternately assigned to one of the 2 treatment groups: group A\u2014AFFIRM<jats:sup>\u00ae<\/jats:sup> (Algea Thearpies, a division of Globus Medical Inc., Audubon, PA); and group B\u2014KYPHON (Kyphon Inc., Sunnyvale, CA). The vertebral bodies were compressed axially on an MTS Bionix 858 machine at a rate of 5 mm\/min until compressed to 40% of the initial anterior height. Load versus displacement was recorded. The fractured VBs then underwent kyphoplasty with cement augmentation. The augmented vertebral bodies were then recompressed and anterior vertebral body height (mm) and wedge angle (degrees) was measured initially, after mechanically creating an anterior wedge fracture, and after repairing the compression fracture. Each vertebral body was subjected to 111 N load to simulate in vivo physiological loading during inflation and cement augmentation. The vertebral height, wedge angle, cement volume, and inflation pressures were compared between the treatment groups using an unpaired <jats:italic toggle=\"yes\">t<\/jats:italic> test (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.05). Failure loads were compared between intact and repaired VBs using a paired <jats:italic toggle=\"yes\">t<\/jats:italic> test (<jats:italic toggle=\"yes\">P<\/jats:italic>&lt;0.05).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>Average lost height restored in group A was 29%, and 30% in group B compared to the compressed state. Similar trends were observed in the mean changes of vertebral body wedge angle in both the groups. No significant difference in mean inflation pressures (group A 182\u00b133 psi; group B 175\u00b137 psi) were found between the 2 groups. Average percentage increase in failure load was 218% and 241% for groups A and B, respectively. Mean injected cement volume was 6.65\u00b10.65 and 6.73\u00b10.41 mL for groups A and B, respectively.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Some height restoration was observed using the 2 bone tamps in fractured vertebral bodies under simulated physiological load. The fracture reduction achieved by the 2 inflatable bone tamps was equivalent. No significant difference between mean inflation pressures and failure load was demonstrated between the 2 groups.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0b013e31829a37ce","type":"journal-article","created":{"date-parts":[[2013,6,1]],"date-time":"2013-06-01T12:13:08Z","timestamp":1370088788000},"page":"E31-E37","source":"Crossref","is-referenced-by-count":6,"title":["An In Vitro Evaluation of Fracture Reduction Achieved by Inflatable Bone Tamps Under Simulated Physiological Load"],"prefix":"10.1097","volume":"30","author":[{"given":"Michael","family":"Gordon","sequence":"first","affiliation":[{"name":"Newport Orthopedic Institute, Newport Beach, CA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Walter C.","family":"Peppelman","sequence":"additional","affiliation":[{"name":"Pennsylvania Spine Institute, Harrisburg"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"William","family":"Beutler","sequence":"additional","affiliation":[{"name":"Pennsylvania Spine Institute, Harrisburg"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Damien","family":"O'Halloran","sequence":"additional","affiliation":[{"name":"Globus Medical Inc., Audubon, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suresh R.","family":"Chinthakunta","sequence":"additional","affiliation":[{"name":"Globus Medical Inc., Audubon, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brandon","family":"Bucklen","sequence":"additional","affiliation":[{"name":"Globus Medical Inc., Audubon, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230831","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1007\/s00586-010-1341-x","article-title":"Vertebral body stenting: a new method for vertebral augmentation versus kyphoplasty","volume":"19","author":"Rotter","year":"2010","journal-title":"Eur Spine J"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1097\/00007632-200208010-00009","article-title":"An ex vivo evaluation of an inflatable bone tamp used to reduce fractures within vertebral bodies under load","volume":"27","author":"Belkoff","year":"2002","journal-title":"Spine"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1097\/00007632-200101150-00008","article-title":"An ex vivo biomechanical evaluation of an inflatable bone tamp used in the treatment of compression fracture","volume":"26","author":"Belkoff","year":"2001","journal-title":"Spine"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1148\/radiol.2373041654","article-title":"Kyphoplasty versus vertebroplasty to increase vertebral body height: a cadaveric study","volume":"237","author":"Hiwatashi","year":"2005","journal-title":"Radiology"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1007\/s00264-011-1283-x","article-title":"Percutaneous vertebroplasty versus balloon kyphoplasty for treatment of osteoporotic vertebral compression fracture: a meta-analysis of randomised and non-randomised controlled trials","volume":"35","author":"Han","year":"2011","journal-title":"Int Orthop"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"2915","DOI":"10.1007\/s00198-011-1639-5","article-title":"Balloon kyphoplasty and vertebroplasty in the management of vertebral compression fractures","volume":"22","author":"Boonen","year":"2011","journal-title":"Osteoporos Int"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"e5","DOI":"10.3171\/foc.2005.18.3.6","article-title":"Immediate and early postoperative pain relief after kyphoplasty without significant restoration of vertebral body height in acute osteoporotic vertebral fractures","volume":"18","author":"Feltes","year":"2005","journal-title":"Neurosurg Focus"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"2806","DOI":"10.1097\/01.brs.0000190885.85675.a0","article-title":"Balloon kyphoplasty is effective in deformity correction of osteoporotic vertebral compression fractures","volume":"30","author":"Voggenreiter","year":"2005","journal-title":"Spine"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"1783","DOI":"10.1097\/BRS.0b013e3181b7cc5d","article-title":"Biomechanical comparison of kyphoplasty versus a titanium mesh implant with cement for stabilization of vertebral compression fractures","volume":"35","author":"Upasani","year":"2010","journal-title":"Spine"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"2468","DOI":"10.1097\/00007632-199912010-00008","article-title":"In vivo intradiscal pressure measurement in healthy individuals and in patients with ongoing back problems","volume":"24","author":"Sato","year":"1999","journal-title":"Spine"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1097\/00007632-199904150-00005","article-title":"New in vivo measurements of pressures in the intervertebral disc in daily life","volume":"24","author":"Wilke","year":"1999","journal-title":"Spine"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"1631","DOI":"10.1097\/00007632-200107150-00026","article-title":"Initial outcome and efficacy of \u201ckyphoplasty\u201d in the treatment of painful osteoporotic vertebral compression fractures","volume":"26","author":"Lieberman","year":"2001","journal-title":"Spine"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1097\/00007632-200001150-00004","article-title":"Effect of augmentation on the mechanics of vertebral wedge fractures","volume":"25","author":"Wilson","year":"2000","journal-title":"Spine"},{"key":"R14-20230831","first-page":"1893","article-title":"Kyphosis correction and height restoration effects of percutaneous vertebroplasty","volume":"24","author":"Teng","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"R15-20230831","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1359\/jbmr.2003.18.1.24","article-title":"The dynamic mobility of vertebral compression fractures","volume":"18","author":"McKiernan","year":"2003","journal-title":"J Bone Miner Res"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"891","DOI":"10.1148\/radiol.2333030400","article-title":"Osteoporotic vertebral collapse: percutaneous vertebroplasty and local kyphosis correction","volume":"233","author":"Carlier","year":"2004","journal-title":"Radiology"},{"key":"R17-20230831","doi-asserted-by":"crossref","first-page":"1772","DOI":"10.1097\/00007632-199909010-00004","article-title":"Biomechanical efficacy of unipedicular versus bipedicular vertebroplasty for the management of osteoporotic compression fractures","volume":"24","author":"Tohmeh","year":"1999","journal-title":"Spine"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201702000-00014","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T18:27:07Z","timestamp":1693506427000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201702000-00014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,2]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0b013e31829a37ce","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2017,2]]}}}