{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,6,20]],"date-time":"2025-06-20T04:44:26Z","timestamp":1750394666636},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:sec>\n            <jats:title>Study Design:<\/jats:title>\n            <jats:p>Cadaveric and biomechanical study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>The aim of this study was to assess the safety and pullout strength of medial, partial nonthreaded thoracic pedicle screws compared with conventional screws.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary of Background Data:<\/jats:title>\n            <jats:p>The perforation rate of the pedicle screws has been reported as high as 41%. Nerve injury and irritation can result from the compression of malpositioned screw on neural structures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods:<\/jats:title>\n            <jats:p>Ten fresh cadavers were studied. Screws, 5.0 and 6.0 mm, were inserted from T1 to T6 and T7 to T12, respectively. Pedicle perforations and fractures were recorded upon screw insertion and final positioning (nonthreaded portion facing medially) after a wide laminectomy. Pullout strength of novel and conventional screws were then tested using an Instron machine in an artificial bone substitute.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>A total of 240 thoracic pedicle screws were inserted. Of them, 88.8% (213 screws) were fully contained during screw insertion. There were 5.0% (12 screws) grade 1 medial perforations and 6.2% (15 screws) grade 1 lateral perforations during screw insertion. Upon final positioning, 93.8% (225 screws) were fully contained. All grade 1 medial perforations, which occurred during insertion, were converted to grade 0. No dural or nerve root injuries occurred. Pedicle split fractures were noted in 6.7% (16 screws). The use of medial, partial nonthreaded screws reduced the overall perforation rate from 11.2% to 6.2%. The mean pullout load for the 5 mm fully threaded screw versus medial, partial nonthreaded was 1419.3\u00b1106.1 N (1275.8\u20131538.8 N) and 1336.6\u00b144.2 N (1293.0\u20131405.1 N) respectively, whereas 6 mm pullout load averaged 2126.0\u00b1134.8 N (1986.3\u20132338.3 N) and 2036.5\u00b1210.0 N (1818.4\u20132355.9 N). The difference was not statistically significant.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>The use of medial, partial nonthreaded pedicle screws reduced the medial perforation rate from 5.0% to 0%; however, the pullout strength was not significantly reduced. The use of this novel screw can potentially reduce the incidence of nerve injury or irritation after medial pedicle perforations.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/bsd.0b013e3182aab29d","type":"journal-article","created":{"date-parts":[[2013,10,1]],"date-time":"2013-10-01T07:11:41Z","timestamp":1380611501000},"page":"E297-E304","source":"Crossref","is-referenced-by-count":6,"title":["The Safety and Strength of a Novel Medial, Partial Nonthreaded Pedicle Screw"],"prefix":"10.1097","volume":"30","author":[{"given":"Mun Keong","family":"Kwan","sequence":"first","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chris Yin Wei","family":"Chan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lim Beng","family":"Saw","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shanmugam","family":"Rukmanikanthan","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lawrence G.","family":"Lenke","sequence":"additional","affiliation":[{"name":"Department of Orthopaedic Surgery, Washington University Medical Center, Saint Louis, MO"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20230831","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1097\/00003086-198602000-00003","article-title":"Internal fixation of the lumbar spine with pedicle screw plating","volume":"203","author":"Roy-Camille","year":"1986","journal-title":"Clin Orthop Relat Res"},{"key":"R2-20230831","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1097\/01.BRS.0000106979.54651.D6","article-title":"Biomechanical evaluation of contemporary posterior spinal internal fixation configurations in an unstable burst-fracture calf spine model: special references of hook configurations and pedicle screws","volume":"29","author":"An","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R3-20230831","doi-asserted-by":"crossref","first-page":"2040","DOI":"10.1097\/01.brs.0000138268.12324.1a","article-title":"Comparative analysis of pedicle screw versus hook instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis","volume":"29","author":"Kim","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R4-20230831","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1097\/01.brs.0000209251.65417.16","article-title":"Combined anterior plus posterior stabilization versus posterior short-segment instrumentation and fusion for mid-lumbar (L2-L4) burst fractures","volume":"31","author":"Korovessis","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R5-20230831","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1097\/00007632-200005010-00018","article-title":"Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 4\u00bd-year series","volume":"25","author":"Parker","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"R6-20230831","doi-asserted-by":"crossref","first-page":"445","DOI":"10.1097\/00024720-200212000-00001","article-title":"The accuracy of pedicle screw placement in the thoracic spine using the \u201cFunnel Technique\u201d: part 1. A cadaveric study","volume":"15","author":"Yingsakmonkol","year":"2002","journal-title":"J Spinal Disord Tech"},{"key":"R7-20230831","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1097\/01.BRS.0000109983.12113.9B","article-title":"Free hand pedicle screw placement in the thoracic spine: is it safe","volume":"29","author":"Kim","year":"2004","journal-title":"Spine (Phila Pa 1976)"},{"key":"R8-20230831","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1097\/00007632-199805010-00021","article-title":"Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique","volume":"23","author":"Xu","year":"1998","journal-title":"Spine (Phila Pa 1976)"},{"key":"R9-20230831","doi-asserted-by":"crossref","first-page":"2049","DOI":"10.1097\/00007632-200109150-00022","article-title":"Thoracic pedicle screw fixation in spinal deformities: are they really safe","volume":"26","author":"Suk","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R10-20230831","doi-asserted-by":"crossref","first-page":"E56","DOI":"10.1097\/01.brs.0000252094.64857.ab","article-title":"Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries","volume":"32","author":"Rajasekaran","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R11-20230831","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1097\/01.BRS.0000048461.51308.CD","article-title":"Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance: a cadaver study","volume":"28","author":"Mirza","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R12-20230831","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.2106\/00004623-199508000-00009","article-title":"Placement of pedicle screws in the thoracic spine. Part II: an anatomical and radiographic assessment","volume":"77","author":"Vaccaro","year":"1995","journal-title":"J Bone Joint Surg Am"},{"key":"R13-20230831","doi-asserted-by":"crossref","first-page":"1047","DOI":"10.1097\/01.ta.0000215949.95089.18","article-title":"The safety of fluoroscopically-assisted thoracic pedicle screw instrumentation for spine trauma","volume":"60","author":"Bransford","year":"2006","journal-title":"J Trauma"},{"key":"R14-20230831","doi-asserted-by":"crossref","first-page":"1519","DOI":"10.2106\/00004623-199911000-00003","article-title":"Complications associated with pedicle screws","volume":"81","author":"Lonstein","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"R15-20230831","first-page":"S223","article-title":"Comparison of computerized tomography and direct visualization in thoracic pedicle screw placement","volume":"97","author":"Rao","year":"2002","journal-title":"J Neurosurg"},{"key":"R16-20230831","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1186\/1471-2474-10-44","article-title":"Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone","volume":"10","author":"Tsai","year":"2009","journal-title":"BMC Musculoskelet Disord"},{"key":"R18-20230831","doi-asserted-by":"crossref","first-page":"E355","DOI":"10.1097\/01.brs.0000219394.48091.d6","article-title":"Pullout strength of thoracic pedicle screw instrumentation: comparison of the transpedicular and extrapedicular techniques","volume":"31","author":"White","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R19-20230831","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1186\/1471-2474-12-33","article-title":"Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: a comparative study between cannulated screws with cement injection and solid screws with cement pre-filling","volume":"12","author":"Chen","year":"2011","journal-title":"BMC Musculoskelet Disord"},{"key":"R20-20230831","doi-asserted-by":"crossref","first-page":"2266S","DOI":"10.1097\/00007632-199410151-00003","article-title":"Surgical treatment alternatives for fixation of unstable fractures of the thoracic and lumbar spine. A meta-analysis","volume":"19","author":"Dickman","year":"1994","journal-title":"Spine (Phila Pa 1976)"},{"key":"R21-20230831","doi-asserted-by":"crossref","first-page":"2400","DOI":"10.1097\/01.brs.0000240212.31241.8e","article-title":"Selective posterior thoracic fusions for adolescent idiopathic scoliosis: comparison of hooks versus pedicle screws","volume":"31","author":"Dobbs","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R22-20230831","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1097\/01.brs.0000197865.20803.d4","article-title":"Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis","volume":"31","author":"Kim","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"R23-20230831","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.jocn.2004.11.006","article-title":"Unstable upper and middle thoracic fractures. Preliminary experience with a posterior transpedicular correction-fixation technique","volume":"12","author":"Payer","year":"2005","journal-title":"J Clin Neurosci"},{"key":"R24-20230831","doi-asserted-by":"crossref","first-page":"2782","DOI":"10.1097\/00007632-200212150-00008","article-title":"The treatment of unstable thoracic spine fractures with transpedicular screw instrumentation: a 3-year consecutive series","volume":"27","author":"Yue","year":"2002","journal-title":"Spine (Phila Pa 1976)"},{"key":"R25-20230831","first-page":"5","article-title":"Pedicle sizes of the thoracic vertebrae from T1 to T12 in Thai adults","volume":"10","author":"Thanapipatsiri","year":"1996","journal-title":"J Asian Orthop Assoc"},{"key":"R26-20230831","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1007\/s00586-003-0586-z","article-title":"Quantitative three-dimensional anatomy of cervical, thoracic and lumbar vertebrae of Chinese Singaporeans","volume":"13","author":"Tan","year":"2004","journal-title":"Eur Spine J"},{"key":"R27-20230831","doi-asserted-by":"crossref","first-page":"1553","DOI":"10.1097\/00007632-199707150-00002","article-title":"Anatomic relations of the thoracic pedicle to the adjacent neural structures","volume":"22","author":"Ebraheim","year":"1997","journal-title":"Spine (Phila Pa 1976)"},{"key":"R28-20230831","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1097\/00002517-200102000-00007","article-title":"Thoracic pedicle: surgical anatomic evaluation and relations","volume":"14","author":"Ugur","year":"2001","journal-title":"J Spinal Disord"},{"key":"R29-20230831","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1097\/00007632-198703000-00012","article-title":"Analysis of the morphometric characteristics of the thoracic and lumbar pedicles","volume":"12","author":"Zindrick","year":"1987","journal-title":"Spine (Phila Pa 1976)"},{"key":"R30-20230831","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.2106\/00004623-199508000-00008","article-title":"Placement of pedicle screws in the thoracic spine. Part I: morphometric analysis of the thoracic vertebrae","volume":"77","author":"Vaccaro","year":"1995","journal-title":"J Bone Joint Surg Am"},{"key":"R31-20230831","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1097\/00007632-199108000-00006","article-title":"Thoracic human vertebrae. Quantitative three-dimensional anatomy","volume":"16","author":"Panjabi","year":"1991","journal-title":"Spine (Phila Pa 1976)"},{"key":"R32-20230831","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1007\/s00586-009-1157-8","article-title":"Safety of thoracic pedicle screw application using the funnel technique in Asians: a cadaveric evaluation","volume":"19","author":"Chan","year":"2010","journal-title":"Eur Spine J"},{"key":"R34-20230831","doi-asserted-by":"crossref","first-page":"2340","DOI":"10.1097\/00007632-200111010-00010","article-title":"In vivo accuracy of thoracic pedicle screws","volume":"26","author":"Belmont","year":"2001","journal-title":"Spine (Phila Pa 1976)"},{"key":"R35-20230831","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1097\/00024720-200212000-00002","article-title":"Thoracic pedicle screw instrumentation using the \u201cFunnel Technique\u201d: part 2. Clinical experience","volume":"15","author":"Viau","year":"2002","journal-title":"J Spinal Disord Tech"},{"key":"R36-20230831","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1097\/00007632-200301010-00021","article-title":"Fluoroscopically assisted pedicle screw fixation for thoracic and thoracolumbar injuries: technique and short-term complications","volume":"28","author":"Carbone","year":"2003","journal-title":"Spine (Phila Pa 1976)"},{"key":"R37-20230831","doi-asserted-by":"crossref","first-page":"1320","DOI":"10.1097\/00007632-199606010-00008","article-title":"Accuracy of pedicle screw placement in lumbar vertebrae","volume":"21","author":"Castro","year":"1996","journal-title":"Spine (Phila Pa 1976)"},{"key":"R38-20230831","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1097\/00024720-200608000-00011","article-title":"Accuracy of pedicle screw placement for upper and middle thoracic pathologies without coronal plane spinal deformity using conventional methods","volume":"19","author":"Guzey","year":"2006","journal-title":"J Spinal Disord Tech"},{"key":"R39-20230831","doi-asserted-by":"crossref","first-page":"E465","DOI":"10.1097\/BRS.0b013e3181d1021a","article-title":"Complications of pedicle screw fixation in scoliosis surgery: a systematic review","volume":"35","author":"Hicks","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"R40-20230831","doi-asserted-by":"crossref","first-page":"402","DOI":"10.1007\/BF01834068","article-title":"Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients","volume":"6","author":"Laine","year":"1997","journal-title":"Eur Spine J"},{"key":"R41-20230831","doi-asserted-by":"crossref","first-page":"E111","DOI":"10.1097\/01.brs.0000254048.79024.8b","article-title":"Pedicle screw placement accuracy: a meta-analysis","volume":"32","author":"Kosmopoulos","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"R42-20230831","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1097\/00003086-198602000-00011","article-title":"An internal fixator for posterior application to short segments of the thoracic, lumbar, or lumbosacral spine. Design and testing","volume":"203","author":"Krag","year":"1986","journal-title":"Clin Orthop Relat Res"},{"key":"R43-20230831","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1097\/00003086-200104000-00031","article-title":"Bending strength and holding power of tibial locking screws","volume":"385","author":"Lin","year":"2001","journal-title":"Clin Orthop Relat Res"},{"key":"R44-20230831","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1115\/1.2796022","article-title":"Factors affecting the pullout strength of cancellous bone screws","volume":"118","author":"Chapman","year":"1996","journal-title":"J Biomech Eng"}],"container-title":["Clinical Spine Surgery: A Spine Publication"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/01933606-201704000-00033","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,31]],"date-time":"2023-08-31T18:35:14Z","timestamp":1693506914000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/01933606-201704000-00033"}},"subtitle":["A Cadaveric and Biomechanical Investigation"],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":42,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/bsd.0b013e3182aab29d","relation":{},"ISSN":["2380-0186"],"issn-type":[{"value":"2380-0186","type":"print"}],"subject":[],"published":{"date-parts":[[2017,4]]}}}