{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,9]],"date-time":"2026-09-09T05:17:28Z","timestamp":1788931048508,"version":"build-2803163510"},"reference-count":61,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Distal radius fractures are the most common upper extremity fracture and volar locking plate fixation has become a common modality for operative management of these injuries over the last 2 decades. However, despite the widespread use of volar locking plates, there remains no comprehensive guide detailing the available reduction techniques using these systems. This review aims to consolidate the reduction techniques from the literature along with the authors\u2019 experiences into a blueprint for distal radius fracture reduction when using a volar plate. Techniques described include those with and without use of the plate and with supplementary means of fixation for both extra-articular and intra-articular fracture patterns.<\/jats:p>","DOI":"10.1097\/bth.0000000000000380","type":"journal-article","created":{"date-parts":[[2022,2,8]],"date-time":"2022-02-08T08:01:32Z","timestamp":1644307292000},"page":"168-177","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["Reduction Techniques in Volar Locking Plate Fixation of Distal Radius Fractures"],"prefix":"10.1097","volume":"26","author":[{"given":"Todd H.","family":"Alter","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bobby B.","family":"Varghese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cristina R.","family":"DelPrete","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian M.","family":"Katt","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James T.","family":"Monica","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,9]]},"reference":[{"key":"R1-20250512","doi-asserted-by":"crossref","first-page":"e242","DOI":"10.1097\/BOT.0000000000000312","article-title":"The epidemiology of upper extremity fractures in the united states, 2009","volume":"29","author":"Karl","year":"2015","journal-title":"J Orthop Trauma"},{"key":"R2-20250512","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.ocl.2017.12.001","article-title":"Evidence-based review of distal radius fractures","volume":"49","author":"Mauck","year":"2018","journal-title":"Orthop Clin North Am"},{"key":"R3-20250512","doi-asserted-by":"crossref","first-page":"767","DOI":"10.1007\/s00423-015-1324-9","article-title":"Comparison of treatment outcomes between nonsurgical and surgical treatment of distal radius fracture in elderly: a systematic review and meta-analysis","volume":"400","author":"Ju","year":"2015","journal-title":"Langenbecks Arch Surg"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1186\/s13018-020-01734-2","article-title":"Nonoperative treatment versus volar locking plate fixation for elderly patients with distal radial fracture: a systematic review and meta-analysis","volume":"15","author":"Li","year":"2020","journal-title":"J Orthop Surg Res"},{"key":"R5-20250512","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1007\/s00776-014-0560-0","article-title":"Outcomes and complications of fractures of distal radius (AO type B and C): volar plating versus nonoperative treatment","volume":"19","author":"Sharma","year":"2014","journal-title":"J Orthop Sci"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1142\/S0218810400000223","article-title":"The treatment of unstable distal radius fractures with volar fixation","volume":"5","author":"Orbay","year":"2000","journal-title":"Hand Surg"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1097\/00000637-200044050-00016","article-title":"Extensor tendon rupture after internal fixation of a distal radius fracture using a dorsally placed AO\/ASIF titanium pi plate. Arbeitsgemeinschaft f\u00fcr Osteosynthesefragen\/Association for the Study of Internal Fixation","volume":"44","author":"Schnur","year":"2000","journal-title":"Ann Plast Surg"},{"key":"R8-20250512","first-page":"789","article-title":"Extensor tendon rupture secondary to the AO\/ASIF titanium distal radius plate without associated plate failure: a case report","volume":"29","author":"Lowry","year":"2000","journal-title":"Am J Orthop"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1007\/s00402-020-03365-y","article-title":"Indications, surgical approach, reduction, and stabilization techniques of distal radius fractures","volume":"140","author":"Leixnering","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"1118","DOI":"10.2106\/JBJS.17.00912","article-title":"A comparison of the effect of one, three, or six weeks of immobilization on function and pain after open reduction and internal fixation of distal radial fractures in adults: a randomized controlled trial","volume":"100","author":"Watson","year":"2018","journal-title":"J Bone Joint Surg Am"},{"key":"R11-20250512","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1007\/s12593-014-0155-1","article-title":"Functional outcome and complications at 2.5 years following volar locking plate fixation of distal radius fractures","volume":"7","author":"MacFarlane","year":"2015","journal-title":"J Hand Microsurg"},{"key":"R12-20250512","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/s00264-010-0974-z","article-title":"Operative treatment of distal radial fractures with locking plate system-a prospective study","volume":"35","author":"Kwan","year":"2011","journal-title":"Int Orthop"},{"key":"R13-20250512","doi-asserted-by":"crossref","first-page":"77","DOI":"10.5435\/JAAOS-D-15-00525","article-title":"Complex distal radius fractures: an anatomic algorithm for surgical management","volume":"25","author":"Rhee","year":"2017","journal-title":"J Am Acad Orthop Surg"},{"key":"R14-20250512","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1051\/sicotj\/2015012","article-title":"Distal radius anatomy applied to the treatment of wrist fractures by plate: a review of recent literature","volume":"1","author":"Obert","year":"2015","journal-title":"SICOT J"},{"key":"R15-20250512","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1016\/j.hcl.2009.08.003","article-title":"Distal radius fractures\u2014classification of treatment and indications for surgery","volume":"26","author":"Ilyas","year":"2010","journal-title":"Hand Clin"},{"key":"R16-20250512","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1016\/0363-5023(90)90143-F","article-title":"Effects of distal radius fracture malunion on wrist joint mechanics","volume":"15","author":"Pogue","year":"1990","journal-title":"J Hand Surg Am"},{"key":"R17-20250512","doi-asserted-by":"crossref","first-page":"492","DOI":"10.1016\/0363-5023(93)90098-N","article-title":"Effects of radial deformity on distal radioulnar joint mechanics","volume":"18","author":"Adams","year":"1993","journal-title":"J Hand Surg [Am]"},{"key":"R18-20250512","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1053\/jhsu.2002.32083","article-title":"The effects of dorsally angulated distal radius fractures on carpal kinematics","volume":"12","author":"Park","year":"2002","journal-title":"J Hand Surg Am"},{"key":"R19-20250512","doi-asserted-by":"crossref","first-page":"159","DOI":"10.5435\/00124635-200505000-00003","article-title":"Plating of the distal radius","volume":"13","author":"Nana","year":"2005","journal-title":"J Am Acad Orthop Surg"},{"key":"R20-20250512","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/0020-1383(89)90113-7","article-title":"Stability assessment of distal radial fractures","volume":"20","author":"Lafontaine","year":"1989","journal-title":"Injury"},{"key":"R21-20250512","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.jhsa.2014.01.006","article-title":"Volar plate fixation failure for volar shearing distal radius fractures with small lunate facet fragments","volume":"39","author":"Beck","year":"2014","journal-title":"J Hand Surg Am"},{"key":"R22-20250512","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1053\/jhsu.1999.0525","article-title":"Wire-loop fixation of volar displaced osteochondral fractures of the distal radius","volume":"24","author":"Chin","year":"1999","journal-title":"J Hand Surg Am"},{"key":"R23-20250512","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1051\/sicotj\/2020026","article-title":"Plate coverage predicts failure for volarly unstable distal radius fractures with volar lunate facet fragments","volume":"6","author":"Izawa","year":"2020","journal-title":"SICOT J"},{"key":"R24-20250512","doi-asserted-by":"crossref","first-page":"1905","DOI":"10.1016\/j.jhsa.2015.03.014","article-title":"Management of severely comminuted distal radius fractures","volume":"40","author":"Brogan","year":"2015","journal-title":"J Hand Surg Am"},{"issue":"suppl 2, pt 2","key":"R25-20250512","first-page":"256","article-title":"Treatment of unstable distal radial fractures with the volar locking plating system. Surgical technique","volume":"89","author":"Chung","year":"2007","journal-title":"J Bone Joint Surg Am"},{"key":"R26-20250512","doi-asserted-by":"crossref","first-page":"1264","DOI":"10.1016\/j.jhsa.2014.03.041","article-title":"The impact of coronal alignment on distal radioulnar joint stability following distal radius fracture","volume":"39","author":"Dy","year":"2014","journal-title":"J Hand Surg Am"},{"key":"R27-20250512","doi-asserted-by":"crossref","first-page":"e31","DOI":"10.2106\/JBJS.ST.15.00075","article-title":"Treatment of distal radial fractures by open reduction and internal fixation with a volar locking plate","volume":"6","author":"Mauser","year":"2016","journal-title":"JBJS Essent Surg Tech"},{"key":"R28-20250512","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.jhsa.2014.08.022","article-title":"Coronal shift of distal radius fractures: influence of the distal interosseous membrane on distal radioulnar joint instability","volume":"40","author":"Trehan","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R29-20250512","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1097\/BTH.0000000000000166","article-title":"A sandwich method using kapandji intrafocal pinning to facilitate palmar plating of displaced distal radius fractures","volume":"21","author":"Huang","year":"2017","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R30-20250512","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1016\/S0030-5898(21)00018-3","article-title":"Intrafocal (Kapandji) pinning of unstable fractures of the distal radius","volume":"24","author":"Greatting","year":"1993","journal-title":"Orthop Clin North Am"},{"key":"R31-20250512","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1097\/BTH.0000000000000108","article-title":"External fixator for maintaining reduction before volar plating: a simple treatment method for association of osteosynthesis type C3 distal radius fracture","volume":"20","author":"Tsai","year":"2016","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R32-20250512","doi-asserted-by":"crossref","first-page":"1624","DOI":"10.1016\/j.jhsa.2007.09.009","article-title":"External fixation of distal radius fractures","volume":"32","author":"Slutsky","year":"2007","journal-title":"J Hand Surg Am"},{"key":"R33-20250512","first-page":"e6849","article-title":"Prospective randomized study comparing the external fixator and volar locking plate in intraarticular distal radius fractures: which is better?","volume":"12","author":"Sharma","year":"2020","journal-title":"Cureus"},{"key":"R34-20250512","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1097\/01.blo.0000205898.21233.f5","article-title":"External fixation techniques for distal radius fractures","volume":"445","author":"Capo","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R35-20250512","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1016\/j.hcl.2010.04.006","article-title":"Nonbridging external fixation of distal radius fractures","volume":"26","author":"Eichenbaum","year":"2010","journal-title":"Hand Clin"},{"key":"R36-20250512","doi-asserted-by":"crossref","first-page":"e103371","DOI":"10.1371\/journal.pone.0103371","article-title":"Biomechanical comparison of osteoporotic distal radius fractures fixed by distal locking screws with different length","volume":"9","author":"Liu","year":"2014","journal-title":"PLoS One"},{"key":"R37-20250512","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1097\/BTH.0000000000000201","article-title":"A novel technique for correcting radial length and translation in distal radius fractures","volume":"22","author":"Wang","year":"2018","journal-title":"Tech Hand Up Extrem Surg"},{"issue":"suppl 1","key":"R38-20250512","doi-asserted-by":"crossref","first-page":"S6","DOI":"10.1097\/BOT.0000000000001206","article-title":"Surgical technique: anterolateral approach to the humerus","volume":"32","author":"Liskutin","year":"2018","journal-title":"J Orthop Trauma"},{"key":"R39-20250512","doi-asserted-by":"crossref","first-page":"2322","DOI":"10.1016\/j.injury.2018.09.010","article-title":"Screw distraction technique for gaining fibular length","volume":"49","author":"Ye","year":"2018","journal-title":"Injury"},{"key":"R40-20250512","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1007\/s10195-013-0245-z","article-title":"Flexor tendon injuries following plate fixation of distal radius fractures: a systematic review of the literature","volume":"14","author":"Asadollahi","year":"2013","journal-title":"J Orthop Traumatol"},{"key":"R41-20250512","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1142\/S0218810414500282","article-title":"Intra-operative correction of volar tilt of distal radius fractures using volar locking plate as reduction tool: review of 24 cases","volume":"19","author":"Sreedharan","year":"2014","journal-title":"Hand Surg"},{"issue":"suppl 3","key":"R42-20250512","doi-asserted-by":"crossref","first-page":"S39","DOI":"10.1097\/BOT.0000000000000904","article-title":"Use of volar plate for indirect coronal plane reduction in an intraarticular distal radius fracture","volume":"31","author":"Senehi","year":"2017","journal-title":"J Orthop Trauma"},{"key":"R43-20250512","doi-asserted-by":"crossref","first-page":"2465","DOI":"10.1016\/j.jhsa.2015.09.008","article-title":"Correction of residual radial translation of the distal fragment in distal radius fracture open reduction","volume":"40","author":"Ross","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R44-20250512","first-page":"160","article-title":"Coronal plane deformity correction in distal radius fracture fixation with the volar locking plate","volume":"27","author":"Aneja","year":"2018","journal-title":"J Surg Orthop Adv"},{"key":"R45-20250512","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1097\/01.bth.0000146774.80480.e9","article-title":"Condylar stabilizing technique for intra-articular fracture of distal radius","volume":"9","author":"Kiyoshige","year":"2005","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R46-20250512","doi-asserted-by":"crossref","first-page":"1516","DOI":"10.1016\/j.jhsa.2006.08.015","article-title":"Arthroscopic management of distal radius fractures","volume":"31A","author":"Wiesler","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R47-20250512","doi-asserted-by":"crossref","first-page":"1505","DOI":"10.1007\/s00590-018-2263-2","article-title":"Why do we use arthroscopy for distal radius fractures?","volume":"28","author":"Ardouin","year":"2018","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R48-20250512","doi-asserted-by":"crossref","first-page":"1694","DOI":"10.1016\/j.jhsa.2011.07.021","article-title":"Technical tips for (dry) arthroscopic reduction and internal fixation of distal radius fractures","volume":"36","author":"Del Pi\u00f1al","year":"2011","journal-title":"J Hand Surg Am"},{"key":"R49-20250512","doi-asserted-by":"crossref","first-page":"547","DOI":"10.1007\/s00064-014-0312-5","article-title":"Arthroscopy of the distal radioulnar joint","volume":"26","author":"Pillukat","year":"2014","journal-title":"Oper Orthop Traumatol"},{"key":"R50-20250512","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1007\/s00402-020-03373-y","article-title":"Arthroscopic assisted treatment of distal radius fractures and concomitant injuries","volume":"140","author":"Kastenberger","year":"2020","journal-title":"Arch Orthop Trauma Surg"},{"key":"R51-20250512","doi-asserted-by":"crossref","first-page":"3017","DOI":"10.1007\/s11999-015-4347-1","article-title":"Are volar locking plates superior to percutaneous k-wires for distal radius fractures? A meta-analysis","volume":"473","author":"Chaudhry","year":"2015","journal-title":"Clin Orthop Relat Res"},{"key":"R52-20250512","doi-asserted-by":"crossref","first-page":"158","DOI":"10.1177\/1753193417735810","article-title":"Percutaneous pinning versus volar locking plate internal fixation for unstable distal radius fractures: a meta-analysis","volume":"43","author":"Peng","year":"2018","journal-title":"J Hand Surg Eur Vol"},{"key":"R53-20250512","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1177\/1753193417743936","article-title":"Volar locking plate fixation versus external fixation of distal radius fractures: a meta-analysis","volume":"43","author":"Gouk","year":"2018","journal-title":"J Hand Surg Eur Vol"},{"key":"R54-20250512","doi-asserted-by":"crossref","first-page":"1280","DOI":"10.2106\/JBJS.19.01442","article-title":"Volar locked plating versus closed reduction and casting for acute, displaced distal radial fractures in the elderly: a systematic review and meta-analysis of randomized controlled trials","volume":"102","author":"Stephens","year":"2020","journal-title":"J Bone Joint Surg Am"},{"key":"R55-20250512","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1055\/s-0038-1667304","article-title":"Complications of volar plating of distal radius fractures: a systematic review","volume":"8","author":"Alter","year":"2019","journal-title":"J Wrist Surg"},{"key":"R56-20250512","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1016\/J.JHSB.2005.09.021","article-title":"Peripheral nerve compression neuropathy after fractures of the distal radius","volume":"31","author":"Bienek","year":"2006","journal-title":"J Hand Surg Br"},{"key":"R57-20250512","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1097\/00003086-198808000-00027","article-title":"Late compression neuropathies after Colles\u2019 fractures","volume":"233","author":"Aro","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"R58-20250512","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1097\/00005131-199607000-00007","article-title":"Contact stress distributions in malreduced intraarticular distal radius fractures","volume":"10","author":"Anderson","year":"1996","journal-title":"J Orthop Trauma"},{"key":"R59-20250512","doi-asserted-by":"crossref","first-page":"739","DOI":"10.2106\/00004623-199605000-00014","article-title":"A comparison of early and late reconstruction of malunited fractures of the distal end of the radius","volume":"78","author":"Jupiter","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"R60-20250512","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.jhsa.2005.10.010","article-title":"Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius","volume":"31","author":"Rozental","year":"2006","journal-title":"J Hand Surg Am"},{"key":"R61-20250512","doi-asserted-by":"crossref","first-page":"2198","DOI":"10.1016\/j.jhsa.2013.08.116","article-title":"Prospective evaluation of distal radius fractures treated with variable-angle volar locking plates","volume":"38","author":"Fowler","year":"2013","journal-title":"J Hand Surg Am"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000380","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:09:53Z","timestamp":1747066193000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000380"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,8]]},"references-count":61,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000380","relation":{},"ISSN":["1531-6572"],"issn-type":[{"value":"1531-6572","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,8]]}}}