{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,11]],"date-time":"2026-02-11T14:22:44Z","timestamp":1770819764152,"version":"3.50.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Extra-articular base fractures of the thumb are typical in hand surgeon practice. Nonoperative methods (spica) and operative methods are available for its management. There are operative methods described, such as plate and screws, Kirschner wires, and intramedullary screws. However, there is only a retrograde technique described. This study aims to present a new technique of an anterograde intramedullary headless compression screw to manage the extra-articular thumb metacarpal base fracture. This minimally invasive method allows an early range of motion and does not cross the articular surface of the thumb. This alternative fixation method has the advantage of low damage to soft tissues and good functional outcomes.<\/jats:p>","DOI":"10.1097\/bth.0000000000000403","type":"journal-article","created":{"date-parts":[[2022,8,2]],"date-time":"2022-08-02T09:00:20Z","timestamp":1659430820000},"page":"17-21","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Anterograde Intramedullary Headless Compression Screw for Managing Extra-articular Thumb Metacarpal Base Fracture: Technique and Report"],"prefix":"10.1097","volume":"27","author":[{"given":"Luis G.","family":"Rosifini Alves Rezende","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2023,3]]},"reference":[{"key":"R1-20250512","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1097\/00007611-197207000-00007","article-title":"Fractures of the thumb metacarpal","volume":"65","author":"Green","year":"1972","journal-title":"South Med J"},{"key":"R2-20250512","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1016\/J.JHSE.2007.06.017","article-title":"Fractures of the tubular bones of the hand","volume":"32","author":"Stanton","year":"2007","journal-title":"J Hand Surg Eur Vol"},{"key":"R3-20250512","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1177\/1753193420924215","article-title":"Retrograde intramedullary headless compression screws for treatment of extra-articular thumb metacarpal base fractures","volume":"45","author":"Barrera-Ochoa","year":"2020","journal-title":"J Hand Surg Eur Vol"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1097\/BTH.0000000000000198","article-title":"Antegrade percutaneous intramedullary fixation technique for metacarpal fractures: prospective study on 150 cases","volume":"22","author":"Rocchi","year":"2018","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R5-20250512","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1016\/j.jhsa.2014.11.023","article-title":"Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws","volume":"40","author":"del Pi\u00f1al","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"1260","DOI":"10.1016\/j.jhsa.2010.04.032","article-title":"Intramedullary cannulated headless screw fixation of a comminuted subcapital metacarpal fracture: case report","volume":"35","author":"Boulton","year":"2010","journal-title":"J Hand Surg Am"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1016\/j.jhsa.2012.09.029","article-title":"Quantitative 3-dimensional CT analyses of intramedullary headless screw fixation for metacarpal neck fractures","volume":"38","author":"ten Berg","year":"2013","journal-title":"J Hand Surg Am"},{"key":"R8-20250512","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1016\/j.jhsg.2019.07.002","article-title":"Antegrade intramedullary screw fixation: a novel approach to metacarpal fractures","volume":"1","author":"Hoang","year":"2019","journal-title":"J Hand Surg Glob On"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1302\/2058-5241.5.190068","article-title":"Intramedullary compression screw fixation of metacarpal and phalangeal fractures","volume":"5","author":"Guidi","year":"2020","journal-title":"EFORT Open Rev"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"e3895","DOI":"10.1097\/GOX.0000000000003895","article-title":"Intramedullary screw fixation comprehensive technique guide for metacarpal and phalanx fractures: pearls and pitfalls","volume":"9","author":"Chao","year":"2021","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R11-20250512","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1097\/BTH.0000000000000363","article-title":"Corrective fifth metacarpal neck osteotomy and intramedullary screw fixation technique: technique and case report","volume":"26","author":"Rosifini Alves Rezende","year":"2022","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R12-20250512","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1177\/1753193419898066","article-title":"Intramedullary screw fixation for metacarpal shaft fractures: a biomechanical human cadaver study","volume":"45","author":"Lab\u00e8r","year":"2020","journal-title":"J Hand Surg Eur Vol"},{"key":"R13-20250512","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1177\/1558944719836214","article-title":"Low rate of complications following intramedullary headless compression screw fixation of metacarpal fractures","volume":"15","author":"Warrender","year":"2020","journal-title":"Hand (N Y)"},{"key":"R14-20250512","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1055\/s-0036-1593390","article-title":"Intramedullary fixation of metacarpal fractures using headless compression screws","volume":"8","author":"Tobert","year":"2016","journal-title":"J Hand Microsurg"},{"key":"R15-20250512","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/BTH.0000000000000302","article-title":"Intramedullary headless screw fixation for metacarpal fractures","volume":"25","author":"Sellers","year":"2021","journal-title":"Tech Hand Up Extrem Surg"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000403","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:10:33Z","timestamp":1747066233000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000403"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,2]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000403","relation":{},"ISSN":["1531-6572"],"issn-type":[{"value":"1531-6572","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8,2]]}}}