{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:40:04Z","timestamp":1747068004329,"version":"3.40.5"},"reference-count":10,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Open reduction internal fixation with plate fixation is commonly used in treating metacarpal fractures to facilitate early rehabilitation. However, it is sometimes challenging to maintain a satisfactory 3-dimensional alignment during the plating process. We present a method using a temporary centrally placed intramedullary k-wire to maintain a fundamental stability for reduction of metacarpal fractures. This method facilitates the plating process and simplifies the open reduction internal fixation of the metacarpal fractures.<\/jats:p>","DOI":"10.1097\/bth.0000000000000408","type":"journal-article","created":{"date-parts":[[2022,8,22]],"date-time":"2022-08-22T12:00:28Z","timestamp":1661169628000},"page":"45-48","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["The Addition of a Temporary Intramedullary K-wire to Facilitate Plating for Metacarpal Fractures"],"prefix":"10.1097","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3721-9386","authenticated-orcid":false,"given":"Chi-Han","family":"Huang","sequence":"first","affiliation":[{"name":"Division of Plastic and Reconstructive Surgery, Department of Surgery, Taipei Veterans General Hospital, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I-Ning","family":"Lo","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan"},{"name":"Department of Orthopaedics, National Yang Ming Chiao Tung University, Taipei, Taiwan"},{"name":"Department of Orthopaedics, Taipei Veterans General Hospital Taitung Branch, Taitung, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung-Pan","family":"Wang","sequence":"additional","affiliation":[{"name":"Department of Orthopaedics and Traumatology, Taipei Veterans General Hospital, Taipei, Taiwan"},{"name":"Department of Orthopaedics, National Yang Ming Chiao Tung University, Taipei, Taiwan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2023,3]]},"reference":[{"key":"R1-20250512","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/S0030-5898(20)31711-9","article-title":"Metacarpal fractures and dislocations","volume":"23","author":"Ashkenaze","year":"1992","journal-title":"Orthop Clin North Am"},{"key":"R2-20250512","doi-asserted-by":"crossref","first-page":"e2261","DOI":"10.1097\/GOX.0000000000002261","article-title":"Extra-articular metacarpal fractures: closed reduction and percutaneous pinning versus open reduction and internal fixation","volume":"7","author":"Vasilakis","year":"2019","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R3-20250512","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1007\/s11552-013-9562-1","article-title":"Metacarpal fractures: treatment and complications","volume":"9","author":"Kollitz","year":"2014","journal-title":"Hand"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1186\/s12891-021-04200-0","article-title":"Metacarpal shaft fixation: a biomechanical comparison of dorsal plating, lag screws, and headless compression screws","volume":"22","author":"Dyrna","year":"2021","journal-title":"BMC Musculoskelet Disord"},{"key":"R5-20250512","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1016\/j.jhsa.2010.01.002","article-title":"Comparison between locking and non-locking plates for fixation of metacarpal fractures in an animal model","volume":"35","author":"Ochman","year":"2010","journal-title":"J Hand Surg Am"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1097\/01.blo.0000205888.04200.c5","article-title":"Extraarticular hand fractures in adults: a review of new developments","volume":"445","author":"Freeland","year":"2006","journal-title":"Clin Orthop Relat Res"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"392.e1","DOI":"10.1016\/j.jhsa.2017.02.013","article-title":"Headless compression screw versus kirschner wire fixation for metacarpal neck fractures: a biomechanical study","volume":"42","author":"Avery","year":"2017","journal-title":"J Hand Surg Am"},{"key":"R8-20250512","doi-asserted-by":"crossref","first-page":"692","DOI":"10.1016\/j.jhsa.2014.11.023","article-title":"Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws","volume":"40","author":"del Pi\u00f1al","year":"2015","journal-title":"J Hand Surg Am"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"466","DOI":"10.1177\/1753193420980324","article-title":"Outcomes of 173 metacarpal and phalangeal fractures treated by intramedullary headless screw fixation with a 4-year follow-up","volume":"46","author":"Poggetti","year":"2021","journal-title":"J Hand Surg Eur Vol"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1177\/1753193416641319","article-title":"Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study","volume":"41","author":"Borbas","year":"2016","journal-title":"J Hand Surg Eur Vol"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000408","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:10:04Z","timestamp":1747066204000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000408"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8,22]]},"references-count":10,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000408","relation":{},"ISSN":["1531-6572"],"issn-type":[{"type":"electronic","value":"1531-6572"}],"subject":[],"published":{"date-parts":[[2022,8,22]]}}}