{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:40:10Z","timestamp":1747068010074,"version":"3.40.5"},"reference-count":16,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Precontoured olecranon plates are frequently used in the management of proximal ulna fractures. Occasionally, in comminuted proximal ulna fractures or segmental ulna fractures, available precontoured olecranon plates are too short for the management of these fractures. The authors have utilized posterolateral distal humerus plates in these instances. The coronal bend in some posterolateral distal humerus plates anecdotally fits well to the proximal ulna, despite being designed for the distal humerus. We sought to measure the coronal angulation of precontoured posterolateral distal humerus plates from various companies and compare these to established proximal ulna angles. Case examples are also provided.<\/jats:p>","DOI":"10.1097\/bth.0000000000000415","type":"journal-article","created":{"date-parts":[[2022,10,26]],"date-time":"2022-10-26T17:00:10Z","timestamp":1666803610000},"page":"79-83","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Plating of Proximal Ulna Fractures Using Posterolateral Distal Humerus Plates: Surgical Technique and Case Series"],"prefix":"10.1097","volume":"27","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9152-0559","authenticated-orcid":false,"given":"Allicia O.","family":"Imada","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"McArthur","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nathan T.","family":"Morrell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2023,6]]},"reference":[{"key":"R1-20250512","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/j.hcl.2015.07.003","article-title":"Olecranon fractures","volume":"31","author":"Brolin","year":"2015","journal-title":"Hand Clin"},{"key":"R2-20250512","doi-asserted-by":"crossref","first-page":"2416","DOI":"10.2106\/JBJS.H.01419","article-title":"Clinical evaluation of locking compression plate fixation for comminuted olecranon fractures","volume":"91","author":"Buijze","year":"2009","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20250512","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1302\/2058-5241.4.180022","article-title":"Fractures of the proximal ulna: current concepts in surgical management","volume":"4","author":"Siebenlist","year":"2019","journal-title":"EFORT Open Rev"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1016\/j.otsr.2014.09.025","article-title":"Critical analysis of olecranon fracture management by pre-contoured locking plates","volume":"101","author":"Niglis","year":"2015","journal-title":"Orthop Traumatol Surg Res"},{"key":"R5-20250512","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1016\/j.jse.2011.07.004","article-title":"Three-dimensional morphometry of the proximal ulna: a comparison to currently used anatomically preshaped ulna plates","volume":"21","author":"Puchwein","year":"2012","journal-title":"J Shoulder Elbow Surg"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"763","DOI":"10.1007\/s00276-014-1260-3","article-title":"Morphometric analysis of the proximal ulna using three-dimensional computed tomography and computer-aided design: varus, dorsal, and torsion angulation","volume":"36","author":"Yong","year":"2014","journal-title":"Surg Radiol Anat"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"1015","DOI":"10.1007\/s00276-014-1287-5","article-title":"Proximal ulna morphometry: which are the \u2018true\u2019 anatomical preshaped olecranon plates?","volume":"36","author":"Totlis","year":"2014","journal-title":"Surg Radiol Anat"},{"key":"R8-20250512","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1302\/0301-620X.89B6.18975","article-title":"The influence of lateral and anterior angulation of the proximal ulna on the treatment of a Monteggia fracture: an anatomical cadaver study","volume":"89","author":"Grechenig","year":"2007","journal-title":"J Bone Joint Surg Br"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1016\/j.cjtee.2020.08.001","article-title":"Expanding the horizons of clinical applications of proximal humerus locking plates in the lower extremities: a technical note","volume":"23","author":"Pires","year":"2020","journal-title":"Chin J Traumatol"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"e312","DOI":"10.1097\/BOT.0000000000001765","article-title":"Use of proximal humerus locking plates for fixation of pediatric femoral neck fractures: technical trick","volume":"34","author":"Gurnea","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R11-20250512","doi-asserted-by":"crossref","first-page":"e0491","DOI":"10.2106\/JBJS.CC.19.00491","article-title":"The repair of an acute pathological subtrochanteric femur fracture using an adult 3.5-mm proximal humerus locking plate in an adolescent patient: a case report","volume":"10","author":"Newbury","year":"2020","journal-title":"JBJS Case Connect"},{"key":"R12-20250512","doi-asserted-by":"crossref","first-page":"e63","DOI":"10.1097\/BOT.0b013e3181f8d9c3","article-title":"Adult proximal humerus locking plate for the treatment of a pediatric subtrochanteric femoral nonunion: a case report","volume":"25","author":"Cortes","year":"2011","journal-title":"J Orthop Trauma"},{"key":"R13-20250512","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s12306-013-0310-z","article-title":"Adult proximal humerus locking plate for fixation of paediatric subtrochanteric fractures","volume":"98","author":"Gogna","year":"2014","journal-title":"Musculoskelet Surg"},{"key":"R14-20250512","doi-asserted-by":"crossref","first-page":"rju069","DOI":"10.1093\/jscr\/rju069","article-title":"Use of a proximal humeral plate for a paediatric peri-prosthetic femoral fracture","volume":"7","author":"Shaw","year":"2014","journal-title":"J Surg Case Rep"},{"key":"R15-20250512","first-page":"370","article-title":"Adult periarticular locking plates for the treatment of pediatric and adolescent subtrochanteric hip fractures","volume":"67","author":"Sanders","year":"2009","journal-title":"Bull NYU Hosp Jt Dis"},{"key":"R16-20250512","first-page":"306","article-title":"Use of proximal humerus plates for the fixation of the subtrochanteric femoral shortening osteotomy during total hip arthroplasty for Crowe type IV developmental dysplasia of the hip patients","volume":"31","author":"\u00c7a\u011flar","year":"2020","journal-title":"Jt Dis Relat Surg"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000415","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:09:59Z","timestamp":1747066199000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000415"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10,26]]},"references-count":16,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000415","relation":{},"ISSN":["1531-6572"],"issn-type":[{"type":"electronic","value":"1531-6572"}],"subject":[],"published":{"date-parts":[[2022,10,26]]}}}