{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T17:58:25Z","timestamp":1774634305450,"version":"3.50.1"},"reference-count":12,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Distal radius fractures are common injuries that often require surgical intervention. Commonly, these fractures are fixed using open reduction internal fixation with plating and screws. This often requires a more extensive soft tissue dissection and exposure. In contrast for certain cases, percutaneous headless compression screws may be appropriate. We present a technique for minimally invasive arthroscopic-assisted reduction and percutaneous screw fixation with an extremity traction device. A case is provided to demonstrate the technique as a viable option for the treatment of intra-articular distal radius fractures.<\/jats:p>","DOI":"10.1097\/bth.0000000000000461","type":"journal-article","created":{"date-parts":[[2023,11,16]],"date-time":"2023-11-16T08:02:15Z","timestamp":1700121735000},"page":"101-105","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Technique for Minimally Invasive, Arthroscopic-assisted Distal Radius Fracture Fixation"],"prefix":"10.1097","volume":"28","author":[{"given":"Vincent","family":"Lau","sequence":"first","affiliation":[{"name":"Jefferson Health, New Jersey Department of Orthopedic Surgery, Stratford, NJ"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rick","family":"Tosti","sequence":"additional","affiliation":[{"name":"Rothman Orthopedic Institute Department of Hand Surgery, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Rivlin","sequence":"additional","affiliation":[{"name":"Rothman Orthopedic Institute Department of Hand Surgery, Philadelphia, PA"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,6]]},"reference":[{"key":"R1-20250512","doi-asserted-by":"crossref","first-page":"478","DOI":"10.3109\/17453670903171875","article-title":"Open reduction and internal fixation compared to closed reduction and external fixation in distal radial fractures: a randomized study of 50 patients","volume":"80","author":"Abramo","year":"2009","journal-title":"Acta Orthop"},{"key":"R3-20250512","doi-asserted-by":"crossref","first-page":"330","DOI":"10.1016\/j.jhsa.2021.11.025","article-title":"Outcomes of arthroscopic-assisted distal radius fracture volar plating: a meta-analysis","volume":"47","author":"Shihab","year":"2022","journal-title":"J Hand Surg"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1051\/sicotj\/2015012","article-title":"Distal radius anatomy applied to the treatment of wrist fractures by plate: a review of recent literature","volume":"1","author":"Obert","year":"2015","journal-title":"SICOT-J"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1007\/s00402-013-1866-7","article-title":"Comparative study of the closed reduction percutaneous cannulated screw fixation and open reduction palmar locking plate fixation in the treatment of AO type A2 distal radius fractures","volume":"134","author":"Gereli","year":"2014","journal-title":"Arch Orthop Trauma Surg"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/j.hcl.2005.02.004","article-title":"Closed manipulation and casting of distal radius fractures","volume":"21","author":"Fernandez","year":"2005","journal-title":"Hand Clin"},{"key":"R8-20250512","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1016\/j.jhsa.2011.01.023","article-title":"Complications of K-wire fixation in procedures involving the hand and wrist","volume":"36","author":"Hsu","year":"2011","journal-title":"J Hand Surg [Am]"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.2106\/00004623-199908000-00005","article-title":"Intra-articular fractures of the distal aspect of the radius: arthroscopically assisted reduction compared with open reduction and internal fixation","volume":"81","author":"Doi","year":"1999","journal-title":"J Bone Joint Surg"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1016\/S0363-5023(97)80068-8","article-title":"Arthroscopic diagnosis of intra-articular soft tissue injuries associated with distal radial fractures","volume":"22","author":"Richards","year":"1997","journal-title":"J Hand Surg"},{"key":"R11-20250512","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1053\/jhsu.2000.6467","article-title":"Peripheral tears of the triangular fibrocartilage complex cause distal radioulnar joint instability after distal radial fractures","volume":"25","author":"Lindau","year":"2000","journal-title":"J Hand Surg [Am]"},{"key":"R12-20250512","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1053\/jars.2003.50154","article-title":"Results of acute arthroscopically repaired triangular fibrocartilage complex injuries associated with intra-articular distal radius fractures","volume":"19","author":"Ruch","year":"2003","journal-title":"Arthroscopy"},{"key":"R13-20250512","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1053\/jhsu.2001.28760","article-title":"Intra-articular distal radius fractures: arthroscopic assessment of radiographically assisted reduction","volume":"26","author":"Edwards","year":"2001","journal-title":"J Hand Surg"},{"issue":"6","key":"R14-20250512","doi-asserted-by":"crossref","first-page":"778","DOI":"10.1302\/0301-620X.90B6.19809","article-title":"Treatment of intra-articular fractures of the distal radius: fluoroscopic or arthroscopic reduction?","volume":"90-B","author":"Varitimidis","year":"2008","journal-title":"J Bone Joint Surg Br"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000461","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:12:52Z","timestamp":1747066372000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000461"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,11,16]]},"references-count":12,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000461","relation":{},"ISSN":["1531-6572"],"issn-type":[{"value":"1531-6572","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,11,16]]}}}