{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,5,13]],"date-time":"2025-05-13T04:05:53Z","timestamp":1747109153730,"version":"3.40.5"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Maintaining the reduction of a transverse humeral shaft fracture can be particularly challenging while applying a compression plate for definitive fixation. Nitinol compression staples are being increasingly utilized in orthopedic surgery due to their unique ability to apply continuous compression between staple legs at body temperature. We have found them to be particularly useful in the maintenance of the reduction of transverse humeral shaft fractures before compression plate application. This simple technique allows for the removal of reduction clamps and precise plate placement. We describe our technique for using nitinol compression staples to augment fracture fixation in transverse humeral shaft fractures as well as our experience using this technique in a case series of 4 patients.<\/jats:p>","DOI":"10.1097\/bth.0000000000000470","type":"journal-article","created":{"date-parts":[[2024,2,2]],"date-time":"2024-02-02T13:01:02Z","timestamp":1706878862000},"page":"80-87","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Augmented Fixation in Transverse Midshaft Humerus Fractures Using a Nitinol Staple: Surgical Technique and Case Series"],"prefix":"10.1097","volume":"28","author":[{"given":"Jack G.","family":"Graham","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Daniel E.","family":"Davis","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,6]]},"reference":[{"key":"R2-20250512","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1302\/2058-5241.6.200033","article-title":"Humeral shaft fractures","volume":"6","author":"Gallusser","year":"2021","journal-title":"EFORT Open Rev"},{"key":"R3-20250512","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s12178-012-9125-z","article-title":"Humeral shaft fractures","volume":"5","author":"Spiguel","year":"2012","journal-title":"Curr Rev Musculoskelet Med"},{"key":"R4-20250512","doi-asserted-by":"crossref","first-page":"290","DOI":"10.2106\/00004623-200402000-00011","article-title":"The incidence of fractures and dislocations referred for orthopaedic services in a capitated population","volume":"86","author":"Brinker","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R5-20250512","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1302\/0301-620X.88B11.17634","article-title":"Fractures of the shaft of the humerus. An epidemiological study of 401 fractures","volume":"88","author":"Ekholm","year":"2006","journal-title":"J Bone Joint Surg Br"},{"key":"R6-20250512","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1016\/j.injury.2006.04.130","article-title":"Epidemiology of adult fractures: a review","volume":"37","author":"Court-Brown","year":"2006","journal-title":"Injury"},{"key":"R7-20250512","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1097\/00003086-198208000-00003","article-title":"Epidemiologic features of humeral fractures","volume":"168","author":"Rose","year":"1982","journal-title":"Clin Orthop Relat Res"},{"key":"R8-20250512","doi-asserted-by":"crossref","first-page":"478","DOI":"10.2106\/00004623-200004000-00003","article-title":"Functional bracing for the treatment of fractures of the humeral diaphysis","volume":"82","author":"Sarmiento","year":"2000","journal-title":"J Bone Joint Surg Am"},{"key":"R9-20250512","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1097\/01.bot.0000246466.01287.04","article-title":"Outcome after closed functional treatment of humeral shaft fractures","volume":"20","author":"Ekholm","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R10-20250512","doi-asserted-by":"crossref","first-page":"1792","DOI":"10.1001\/jama.2020.3182","article-title":"Effect of surgery vs functional bracing on functional outcome among patients with closed displaced humeral shaft fractures: The FISH randomized clinical trial","volume":"323","author":"R\u00e4m\u00f6","year":"2020","journal-title":"JAMA"},{"key":"R11-20250512","doi-asserted-by":"crossref","first-page":"597","DOI":"10.1097\/01.bot.0000249423.48074.82","article-title":"Treatment of diaphyseal fractures of the humerus using a functional brace","volume":"20","author":"Rutgers","year":"2006","journal-title":"J Orthop Trauma"},{"key":"R12-20250512","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3928\/01477447-20100924-02","article-title":"Outcome of nonoperative vs operative treatment of humeral shaft fractures: a retrospective study of 213 patients","volume":"33","author":"Denard","year":"2010","journal-title":"Orthopedics"},{"key":"R13-20250512","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1016\/j.jse.2020.01.072","article-title":"Conservative vs. operative treatment for humeral shaft fractures: A meta-analysis and systematic review of randomized clinical trials and observational studies","volume":"29","author":"van de Wall","year":"2020","journal-title":"J Shoulder Elbow Surg"},{"key":"R14-20250512","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1097\/BOT.0000000000001666","article-title":"Modern results of functional bracing of humeral shaft fractures: a multicenter retrospective analysis","volume":"34","author":"Serrano","year":"2020","journal-title":"J Orthop Trauma"},{"key":"R15-20250512","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1007\/s10195-017-0459-6","article-title":"Humeral shaft fractures: National trends in management","volume":"18","author":"Schoch","year":"2017","journal-title":"J Orthop Traumatol"},{"key":"R16-20250512","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1016\/j.matdes.2013.11.084","article-title":"A review of shape memory alloy research, applications and opportunities","volume":"56","author":"Mohd Jani","year":"2014","journal-title":"Mater Des"},{"key":"R17-20250512","doi-asserted-by":"crossref","first-page":"228","DOI":"10.1016\/j.jmbbm.2015.06.010","article-title":"Fatigue of Nitinol: The state-of-the-art and ongoing challenges","volume":"50","author":"Mahtabi","year":"2015","journal-title":"J Mech Behav Biomed Mater"},{"key":"R18-20250512","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/S0921-5093(99)00294-4","article-title":"An overview of Nitinol medical applications","volume":"A273\u2013275","author":"Duerig","year":"1999","journal-title":"Mater Sci Eng"},{"key":"R19-20250512","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/j.ocl.2019.02.002","article-title":"Fracture fixation using shape-memory (Ninitol) Staples","volume":"50","author":"Wu","year":"2019","journal-title":"Orthop Clin North Am"},{"key":"R20-20250512","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.jmbbm.2007.08.001","article-title":"Fatigue and durability of Nitinol stents","volume":"1","author":"Pelton","year":"2008","journal-title":"J Mech Behav Biomed Mater"},{"key":"R21-20250512","doi-asserted-by":"crossref","first-page":"1469","DOI":"10.1016\/j.joen.2009.06.015","article-title":"A review of cyclic fatigue testing of nickel-titanium rotary instruments","volume":"35","author":"Plotino","year":"2009","journal-title":"J Endod"},{"key":"R22-20250512","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s40634-016-0055-3","article-title":"Biomechanical evaluation of shape-memory alloy staples for internal fixation-an in vitro study","volume":"3","author":"Hoon","year":"2016","journal-title":"J Exp Orthop"},{"key":"R23-20250512","first-page":"712","article-title":"Internal fixation with Ni-Ti shape memory alloy compressive staples in orthopedic surgery. A review of 51 cases","volume":"100","author":"Yang","year":"1987","journal-title":"Chin Med J (Engl)"},{"key":"R24-20250512","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/0020-1383(93)90313-U","article-title":"Treatment of intra-articular fractures with shape memory compression staples","volume":"24","author":"Dai","year":"1993","journal-title":"Injury"},{"key":"R25-20250512","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1053\/j.jfas.2004.07.003","article-title":"First metatarsophalangeal joint arthrodesis: A new technique of internal fixation by using memory compression staples","volume":"43","author":"Choudhary","year":"2004","journal-title":"J Foot Ankle Surg"},{"key":"R26-20250512","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1097\/01.bth.0000231581.70524.0c","article-title":"Three-corner wrist fusion using memory staples","volume":"10","author":"van Riet","year":"2006","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R27-20250512","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/01.bth.0000236982.68719.c8","article-title":"Lunocapitate fusion using the OSStaple compression staple","volume":"10","author":"Ronchetti","year":"2006","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R28-20250512","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1053\/j.jfas.2005.12.008","article-title":"Tarsal joint fusion using memory compression staples--a study of 10 cases","volume":"45","author":"Malal","year":"2006","journal-title":"J Foot Ankle Surg"},{"key":"R29-20250512","doi-asserted-by":"crossref","first-page":"102","DOI":"10.7547\/0960102","article-title":"Nitinol compression staples for bone fixation in foot surgery","volume":"96","author":"Mereau","year":"2006","journal-title":"J Am Podiatr Med Assoc"},{"key":"R30-20250512","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1177\/1071100717737740","article-title":"Radiographic results of nitinol compression staples for hindfoot and midfoot arthrodeses","volume":"39","author":"Schipper","year":"2018","journal-title":"Foot Ankle Int"},{"key":"R31-20250512","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1097\/BTH.0000000000000303","article-title":"The use of nitinol compression staple fixation and bone graft for scaphoid waist fractures and nonunion: A surgical technique","volume":"25","author":"Congiusta","year":"2020","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R32-20250512","first-page":"102","article-title":"A novel and simple method for stabilizing a transverse segment in a posterior wall acetabular fracture: continuous compression staples, a report of three cases","volume":"12","author":"Ochuba","year":"2022","journal-title":"J Orthop Case Rep"},{"key":"R33-20250512","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1177\/1558944721999732","article-title":"Retrospective comparison of capitolunate arthrodesis using headless compression screws versus nitinol memory staples for SLAC and SNAC Wrist: Radiographic, functional, and patient-reported outcomes","volume":"18","author":"McKnight","year":"2023","journal-title":"Hand (N Y)"},{"key":"R35-20250512","doi-asserted-by":"crossref","first-page":"e263","DOI":"10.5435\/JAAOS-D-18-00142","article-title":"Radial nerve palsy recovery with fractures of the humerus: An updated systematic review","volume":"28","author":"Ilyas","year":"2020","journal-title":"J Am Acad Orthop Surg"},{"key":"R36-20250512","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1177\/10711007221080963","article-title":"Radiographically occult nonunions after application of nitinol compression staples: A report of 3 cases","volume":"43","author":"Zhao","year":"2022","journal-title":"Foot Ankle Int"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000470","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,12]],"date-time":"2025-05-12T16:11:40Z","timestamp":1747066300000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000470"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,2,2]]},"references-count":34,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000470","relation":{},"ISSN":["1531-6572"],"issn-type":[{"type":"electronic","value":"1531-6572"}],"subject":[],"published":{"date-parts":[[2024,2,2]]}}}