{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T06:04:57Z","timestamp":1763445897893,"version":"3.45.0"},"reference-count":8,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","funder":[{"name":"Tampa General Hospital"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>Four-corner fusion is a reliable surgical option for symptomatic scapholunate advanced collapse and scaphoid nonunion advanced collapse. There are multiple current techniques with potential complications, including nonunion, hardware failure, impingement, and cartilage disruption. Despite these potential complications, 4-corner fusion can result in good functional outcomes and patient satisfaction. We present a cartilage-sparing technique using snap-off compression pins for 4-corner fusion. Potential benefits of this technique include strong internal fixation and stable compression with implants that avoid dorsal surfaces and the radiolunate articulation.<\/jats:p>","DOI":"10.1097\/bth.0000000000000531","type":"journal-article","created":{"date-parts":[[2025,8,20]],"date-time":"2025-08-20T04:00:08Z","timestamp":1755662408000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Snap Off Compression Pins for 4 Corner Fusion With Case Series"],"prefix":"10.1097","volume":"29","author":[{"given":"Gus","family":"Strauss","sequence":"first","affiliation":[{"name":"Hand and Upper Extremity Surgery, Florida Orthopaedic Institute, Temple Terrace"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-1698-0292","authenticated-orcid":false,"given":"Tantien","family":"Nguyen","sequence":"additional","affiliation":[{"name":"Foundation for Orthopaedic Research and Education"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michael","family":"Doarn","sequence":"additional","affiliation":[{"name":"Hand and Upper Extremity Surgery, Florida Orthopaedic Institute, Temple Terrace"},{"name":"Department of Orthopaedic Surgery, Tampa General Hospital"},{"name":"Department of Orthopaedics and Sports Medicine, University of South Florida, Tampa, FL"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2025,12]]},"reference":[{"key":"R1-20251118","doi-asserted-by":"crossref","first-page":"909","DOI":"10.1016\/j.bjps.2018.12.033","article-title":"Four-corner fusion: comparing outcomes of conventional K-wire-, locking plate-, and retrograde headless compression screw fixations","volume":"72","author":"Erne","year":"2019","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"R2-20251118","doi-asserted-by":"crossref","first-page":"57","DOI":"10.1097\/00003086-198601000-00008","article-title":"Evolution of arthritis of the wrist","volume":"202","author":"Watson","year":"1986","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20251118","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.jhsa.2023.11.009","article-title":"A changing landscape in the surgical management of wrist arthritis: an analysis of national trends from 2009 to 2019","volume":"49","author":"Kopriva","year":"2024","journal-title":"J Hand Surg Am"},{"key":"R4-20251118","doi-asserted-by":"crossref","first-page":"703.e1","DOI":"10.1016\/j.jhsa.2019.02.016","article-title":"Cerclage fusion technique for 4-corner arthrodesis","volume":"44","author":"Goyal","year":"2019","journal-title":"J Hand Surg Am"},{"key":"R5-20251118","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1177\/1753193408094444","article-title":"Four-corner arthrodesis using the Quad memory staple","volume":"34","author":"Van Amerongen","year":"2009","journal-title":"J Hand Surg Eur Vol"},{"key":"R6-20251118","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.jhsb.2006.08.016","article-title":"Complications of circular plate fixation for four-corner arthrodesis","volume":"32","author":"Shindle","year":"2007","journal-title":"J Hand Surg Eur Vol"},{"key":"R7-20251118","doi-asserted-by":"crossref","first-page":"102886","DOI":"10.1016\/j.otsr.2021.102886","article-title":"Four-corner fusion: clinical and radiological outcome after fixation by headless compression screws or dorsal locking plate at minimum 5 years\u2019 follow-up","volume":"107","author":"d\u2019Almeida","year":"2021","journal-title":"Orthop Traumatol Surg Res"},{"key":"R8-20251118","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1055\/s-0035-1549277","article-title":"The long-term outcome of four-corner fusion","volume":"4","author":"Trail","year":"2015","journal-title":"J Wrist Surg"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000531","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,18]],"date-time":"2025-11-18T06:00:24Z","timestamp":1763445624000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0000000000000531"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,21]]},"references-count":8,"journal-issue":{"issue":"4","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0000000000000531","relation":{},"ISSN":["1531-6572"],"issn-type":[{"type":"electronic","value":"1531-6572"}],"subject":[],"published":{"date-parts":[[2025,8,21]]},"assertion":[{"value":"2025-01-29","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-14","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}