{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T02:26:52Z","timestamp":1781490412657,"version":"3.54.1"},"reference-count":28,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2012,12]]},"DOI":"10.1097\/bth.0b013e31826d221a","type":"journal-article","created":{"date-parts":[[2012,11,16]],"date-time":"2012-11-16T08:00:19Z","timestamp":1353052819000},"page":"236-241","source":"Crossref","is-referenced-by-count":10,"title":["Four-corner Arthrodesis With a Locking, Dorsal Circular Polyether-Ether-Ketone (PEEK-Optima) Plate"],"prefix":"10.1097","volume":"16","author":[{"given":"Peter C.","family":"Rhee","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sanjeev","family":"Kakar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander Y.","family":"Shin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-14-20210126","first-page":"358","article-title":"The SLAC wrist: scapholunate advanced collapse pattern of degenerative arthritis.","volume":"9A","author":"Watson","year":"1987","journal-title":"J Hand Surg"},{"key":"R2-14-20210126","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1054\/JHSB.1999.0066","article-title":"One thousand intercarpal arthrodeses.","volume":"24B","author":"Watson","year":"1999","journal-title":"J Hand Surg"},{"key":"R3-14-20210126","doi-asserted-by":"crossref","first-page":"741","DOI":"10.1016\/0363-5023(94)90177-5","article-title":"Scapholunate advanced collapse wrist salvage.","volume":"19A","author":"Ashmead","year":"1994","journal-title":"J Hand Surg"},{"key":"R4-14-20210126","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.jhsa.2010.01.025","article-title":"The outcome of scaphoid excision and four-corner arthrodesis for advanced carpal collapse at a minimum of ten years.","volume":"35A","author":"Bain","year":"2010","journal-title":"J Hand Surg"},{"key":"R5-14-20210126","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1053\/jhsu.2001.20160","article-title":"Degenerative arthritis of the wrist: proximal row carpectomy versus scaphoid excision and four-corner arthrodesis.","volume":"26A","author":"Cohen","year":"2001","journal-title":"J Hand Surg"},{"key":"R6-14-20210126","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/01.sap.0000194245.94684.54","article-title":"Long-term results of midcarpal arthrodesis in the treatment of scaphoid nonunion advanced collapse (SNAC-Wrist) and scapholunate advanced collapse (SLAC-Wrist).","volume":"56","author":"Dacho","year":"2006","journal-title":"Ann Plast Surg"},{"key":"R7-14-20210126","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/0363-5023(94)90178-3","article-title":"Surgical treatment of scapholunate advanced collapse.","volume":"19A","author":"Krakauer","year":"1994","journal-title":"J Hand Surg"},{"key":"R8-14-20210126","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1097\/BTH.0b013e3181f60fec","article-title":"Four-corner fusion and scaphoid excision using headless compression screws for SLAC and SNAC wrist deformities.","volume":"15","author":"Richards","year":"2011","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R9-14-20210126","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/S0363-5023(96)80097-9","article-title":"Midcarpal arthrodesis.","volume":"1A","author":"Siegel","year":"1996","journal-title":"J Hand Surg"},{"key":"R10-14-20210126","doi-asserted-by":"crossref","first-page":"965","DOI":"10.1016\/S0363-5023(05)80144-3","article-title":"Motion-preserving procedures in the treatment of scapholunate advanced collapse wrist: proximal row carpectomy versus four-corner arthrodesis.","volume":"20A","author":"Wyrick","year":"1995","journal-title":"J Hand Surg"},{"key":"R11-14-20210126","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s11999-009-1139-5","article-title":"High fusion rates with circular plate fixation for four-corner arthrodesis of the wrist.","volume":"468","author":"Bedford","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"R12-14-20210126","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1097\/01.prs.0000227737.90007.5d","article-title":"A prospective outcomes study of four-corner wrist arthrodesis using a circular limited wrist fusion plate for stage II scapholunate advanced collapse wrist deformity.","volume":"118","author":"Chung","year":"2006","journal-title":"Plast Reconstr Surg"},{"key":"R13-14-20210126","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1097\/BTH.0b013e31815e4580","article-title":"Spider plate fixation: no significant improvement in limited wrist arthrodesis.","volume":"12","author":"Collins","year":"2008","journal-title":"Tech Hand Up Extrem Surg"},{"key":"R14-14-20210126","first-page":"323","article-title":"Outcome of four-corner arthrodesis for advanced carpal collapse: circular plate versus traditional techniques.","volume":"75","author":"De Smet","year":"2009","journal-title":"Acta Orthop Belg"},{"key":"R15-14-20210126","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/j.jhsa.2005.04.007","article-title":"Results of four-corner arthrodesis using dorsal circular plate fixation.","volume":"30A","author":"Kendall","year":"2005","journal-title":"J Hand Surg"},{"key":"R16-14-20210126","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/j.jhsa.2008.02.001","article-title":"Four-corner arthrodesis using a circular plate and distal radius bone grafting: a consecutive case series.","volume":"33A","author":"Merrell","year":"2008","journal-title":"J Hand Surg"},{"key":"R17-14-20210126","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1016\/0363-5023(93)90412-V","article-title":"Lunotriquetral arthrodesis.","volume":"18A","author":"Nelson","year":"1993","journal-title":"J Hand Surg"},{"key":"R18-14-20210126","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1007\/s11552-008-9099-x","article-title":"Scaphoid excision and limited wrist fusion: a comparison of K-wire and circular plate fixation.","volume":"3","author":"Rodgers","year":"2008","journal-title":"Hand"},{"key":"R19-14-20210126","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1016\/j.jhsb.2006.08.016","article-title":"Complications of circular plate fixation for four-corner arthrodesis.","volume":"32B","author":"Shindle","year":"2007","journal-title":"J Hand Surg"},{"key":"R20-14-20210126","doi-asserted-by":"crossref","first-page":"1122","DOI":"10.1016\/j.jhsa.2005.08.007","article-title":"Complications and outcome of four-corner arthrodesis: circular plate fixation versus traditional techniques.","volume":"30A","author":"Vance","year":"2005","journal-title":"J Hand Surg"},{"key":"R22-14-20210126","doi-asserted-by":"crossref","first-page":"76","DOI":"10.1080\/02841850601026450","article-title":"Imaging of four-corner fusion (SLAC arthrodesis) of the wrist with 64-slice computed tomography.","volume":"48","author":"Ekelund","year":"2007","journal-title":"Acta Radiol"},{"key":"R23-14-20210126","doi-asserted-by":"crossref","first-page":"4845","DOI":"10.1016\/j.biomaterials.2007.07.013","article-title":"PEEK biomaterials in trauma, orthopedic, and spinal implants.","volume":"28","author":"Kurtz","year":"2007","journal-title":"Biomaterials"},{"key":"R24-14-20210126","doi-asserted-by":"crossref","first-page":"470","DOI":"10.55095\/achot2010\/078","article-title":"Polyetheretherketone (PEEK). Part II: application in clinical practice.","volume":"77","author":"Pokorny","year":"2010","journal-title":"Acta Chir Orthop Traumatol Cech"},{"key":"R25-14-20210126","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1177\/1753193411406799","article-title":"Biomechanical comparison of three fixation techniques used for four-corner arthrodesis.","volume":"36B","author":"Kraisarin","year":"2011","journal-title":"J Hand Surg"},{"key":"R26-14-20210126","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1016\/j.jhsa.2008.08.023","article-title":"Biomechanical comparison of the holding strength of a peek-optima circular plate versus a stainless steel oblique T-plate for radioscapholunate arthrodesis.","volume":"33A","author":"Isaacs","year":"2008","journal-title":"J Hand Surg"},{"key":"R27-14-20210126","doi-asserted-by":"crossref","first-page":"1291","DOI":"10.1016\/j.jhsa.2007.07.023","article-title":"A method of defining palpable landmarks for the ligament-splitting dorsal wrist capsulotomy.","volume":"32A","author":"Berger","year":"2007","journal-title":"J Hand Surg"},{"key":"R28-14-20210126","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/00000637-199507000-00011","article-title":"New dorsal capsulotomy for the surgical exposure of the wrist.","volume":"35","author":"Berger","year":"1995","journal-title":"Ann Plast Surg"},{"key":"R30-14-20210126","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1053\/jssh.2001.23905","article-title":"Four-corner arthrodesis.","volume":"1","author":"Shin","year":"2001","journal-title":"J Am Soc Surg Hand"}],"container-title":["Techniques in Hand &amp; Upper Extremity Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/BTH.0b013e31826d221a","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,6,26]],"date-time":"2023-06-26T20:33:28Z","timestamp":1687811608000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00130911-201212000-00014"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,12]]},"references-count":28,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2012]]}},"URL":"https:\/\/doi.org\/10.1097\/bth.0b013e31826d221a","relation":{},"ISSN":["1089-3393"],"issn-type":[{"value":"1089-3393","type":"print"}],"subject":[],"published":{"date-parts":[[2012,12]]}}}