{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,19]],"date-time":"2026-05-19T21:11:08Z","timestamp":1779225068155,"version":"3.51.4"},"reference-count":13,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"8","license":[{"start":{"date-parts":[[2022,8,1]],"date-time":"2022-08-01T00:00:00Z","timestamp":1659312000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>Mechanical power (MP) is a way of estimating the energy delivered by the ventilator to the patient. For both volume-controlled ventilation (VCV) and pressure-controlled ventilation (PCV) methods have been described to calculate the MP. The pressure-volume (PV) loop, from which the MP is calculated, is different for VCV compared with PCV. We aimed to compare the MP of VCV with zero pause time (VCV-0), VCV with 10% pause time (VCV-10), and PCV within patients in different patient categories based on severity of lung injury.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>In a proof-of-concept study, we enrolled 46 mechanically ventilated patients without spontaneous breathing efforts. Baseline measurements were done in pressure-controlled mode. Subsequently, measurements were done in VCV-0 and VCV-10. Tidal volume and all other settings were kept the same.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>ICU, single university medical center.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Fifty-eight cases in 46 patients on controlled ventilation modes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>Comparison between the MP of PCV, VCV-0, and VCV-10.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENT AND MAIN RESULTS:<\/jats:title>\n            <jats:p>The mean MP of VCV-0, VCV-10, and PCV was 19.30, 21.80, and 20.87 J\/min, respectively (<jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.05 for all comparisons). The transpulmonary MP of VCV-0, VCV-10, and PCV was 6.75, 8.60, and 7.99 J\/min, respectively (<jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.05 for all comparisons).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>In patients ventilated in a controlled mode, VCV without pause time had the lowest MP followed by PCV. VCV with 10% pause time had the highest MP.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000000741","type":"journal-article","created":{"date-parts":[[2022,8,15]],"date-time":"2022-08-15T20:00:27Z","timestamp":1660593627000},"page":"e0741","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":11,"title":["Mechanical Power Differs Between Pressure-Controlled Ventilation and Different Volume-Controlled Ventilation Modes"],"prefix":"10.1097","volume":"4","author":[{"given":"Petra J.","family":"Rietveld","sequence":"first","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jacob W. M.","family":"Snoep","sequence":"additional","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marjolein","family":"Lamping","sequence":"additional","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Franciska","family":"van der Velde","sequence":"additional","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Evert","family":"de Jonge","sequence":"additional","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David W.","family":"van Westerloo","sequence":"additional","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abraham","family":"Schoe","sequence":"additional","affiliation":[{"name":"All authors: Department of Intensive Care, Leiden University Medical Centre, Leiden, The Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2022,8,15]]},"reference":[{"key":"R1-20240807","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1186\/2110-5820-1-28","article-title":"Ventilator-induced lung injury: Historical perspectives and clinical implications.","volume":"1","author":"de Prost","year":"2011","journal-title":"Ann Intensive Care"},{"key":"R2-20240807","doi-asserted-by":"crossref","first-page":"15s","DOI":"10.1183\/09031936.03.00021303","article-title":"Physical and biological triggers of ventilator-induced lung injury and its prevention.","volume":"47","author":"Gattinoni","year":"2003","journal-title":"Eur Respir J Suppl"},{"key":"R3-20240807","doi-asserted-by":"crossref","first-page":"286","DOI":"10.21037\/atm.2017.07.08","article-title":"Driving pressure and mechanical power: New targets for VILI prevention.","volume":"5","author":"Tonetti","year":"2017","journal-title":"Ann Transl Med"},{"key":"R4-20240807","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1007\/s00134-016-4505-2","article-title":"Ventilator-related causes of lung injury: The mechanical power.","volume":"42","author":"Gattinoni","year":"2016","journal-title":"Intensive Care Med"},{"key":"R5-20240807","doi-asserted-by":"crossref","first-page":"1100","DOI":"10.1097\/ALN.0000000000001056","article-title":"Mechanical power and development of ventilator-induced lung injury.","volume":"124","author":"Cressoni","year":"2016","journal-title":"Anesthesiology"},{"key":"R6-20240807","doi-asserted-by":"crossref","first-page":"1914","DOI":"10.1007\/s00134-018-5375-6","article-title":"Mechanical power of ventilation is associated with mortality in critically ill patients: An analysis of patients in two observational cohorts.","volume":"44","author":"Serpa Neto","year":"2018","journal-title":"Intensive Care Med"},{"key":"R7-20240807","doi-asserted-by":"crossref","first-page":"1495","DOI":"10.1007\/s00134-019-05698-8","article-title":"Calculating mechanical power for pressure-controlled ventilation.","volume":"45","author":"van der Meijden","year":"2019","journal-title":"Intensive Care Med"},{"key":"R8-20240807","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1378\/chest.14-3169","article-title":"Pressure-controlled vs volume-controlled ventilation in acute respiratory failure: A physiology-based narrative and systematic review.","volume":"148","author":"Rittayamai","year":"2015","journal-title":"Chest"},{"key":"R9-20240807","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1164\/rccm.201312-2193CI","article-title":"The application of esophageal pressure measurement in patients with respiratory failure.","volume":"189","author":"Akoumianaki","year":"2014","journal-title":"Am J Respir Crit Care Med"},{"key":"R10-20240807","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1186\/s13054-017-1905-9","article-title":"Regional physiology of ARDS.","volume":"21","author":"Gattinoni","year":"2017","journal-title":"Crit Care"},{"key":"R11-20240807","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1186\/s40635-019-0276-8","article-title":"Mechanical power at a glance: A simple surrogate for volume-controlled ventilation.","volume":"7","author":"Giosa","year":"2019","journal-title":"Intensive Care Med Exp"},{"key":"R12-20240807","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1007\/s00134-019-05636-8","article-title":"Calculation of mechanical power for pressure-controlled ventilation.","volume":"45","author":"Becher","year":"2019","journal-title":"Intensive Care Med"},{"key":"R13-20240807","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1186\/s13054-020-03116-w","article-title":"Bedside calculation of mechanical power during volume- and pressure-controlled mechanical ventilation.","volume":"24","author":"Chiumello","year":"2020","journal-title":"Crit Care"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000741","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T14:35:58Z","timestamp":1723041358000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000741"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,8]]},"references-count":13,"journal-issue":{"issue":"8","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000000741","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,8]]}}}