{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T10:05:13Z","timestamp":1780567513788,"version":"3.54.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","license":[{"start":{"date-parts":[[2022,10,1]],"date-time":"2022-10-01T00:00:00Z","timestamp":1664582400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>Evaluate the time course of thrombocytopenia in patients with Impella devices (Abiomed, Danvers, MA).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>This was a retrospective, multicenter review of electronic medical records at a large hospital system from April 2018 to August 2020.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Electronic medical records of patients at SSM Health hospitals were reviewed.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Patients 18\u201389 years old admitted to an SSM Health hospital from April 2018 to August 2020 who received greater than or equal to 24 hours of percutaneous mechanical circulatory support (pMCS) with an Impella device were included. Exclusion criteria were use of other pMCS devices, history of heparin-induced thrombocytopenia (HIT), and presence of device upon transfer from an outside hospital.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>None.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Ninety-three patients were included. The median duration of pMCS was 63.5 hours. Thrombocytopenia occurred in 86% of patients and was evident 24 hours after device placement. The platelet nadir occurred 84 hours after device placement. Platelet recovery occurred 86.5 hours after device removal. The duration of thrombocytopenia was 156 hours. Signs of hemolysis were present in 44.09% of patients, were evident 12\u201324 hours after device placement, and resolved after device removal.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Thrombocytopenia occurred in the majority of patients and was evident 24 hours after device placement. The time course of thrombocytopenia mirrored that of hemolysis.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000000772","type":"journal-article","created":{"date-parts":[[2022,10,10]],"date-time":"2022-10-10T20:00:07Z","timestamp":1665432007000},"page":"e0772","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":5,"title":["Evaluation of Thrombocytopenia in Patients Receiving Percutaneous Mechanical Circulatory Support With an Impella Device"],"prefix":"10.1097","volume":"4","author":[{"given":"Erin A.","family":"Houry","sequence":"first","affiliation":[{"name":"Department of Pharmacy, SSM Health Saint Louis University Hospital, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brooke E.","family":"Gengler","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, SSM Health Saint Louis University Hospital, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Justin L.","family":"Alberts","sequence":"additional","affiliation":[{"name":"Department of Pharmacy Practice, St. Louis College of Pharmacy at UHSP in St. Louis, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph S.","family":"Van Tuyl","sequence":"additional","affiliation":[{"name":"Department of Pharmacy, SSM Health Saint Louis University Hospital, St. Louis, MO."},{"name":"Department of Pharmacy Practice, St. Louis College of Pharmacy at UHSP in St. Louis, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,10,7]]},"reference":[{"key":"R1-20240807","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1055\/s-0038-1676369","article-title":"The impella device: Historical background, clinical applications and future directions.","volume":"28","author":"Glazier","year":"2019","journal-title":"Int J Angiol"},{"key":"R2-20240807","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1186\/s13019-016-0513-0","article-title":"IABP: History-evolution-pathophysiology-indications: What we need to know.","volume":"11","author":"Parissis","year":"2016","journal-title":"J Cardiothorac Surg"},{"key":"R3-20240807","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1111\/j.1540-8183.2008.00363.x","article-title":"Thrombocytopenia in patients treated with heparin, combination antiplatelet therapy, and intra-aortic balloon pump counterpulsation.","volume":"21","author":"Bream-Rouwenhorst","year":"2008","journal-title":"J Interv Cardiol"},{"key":"R4-20240807","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1007\/s40119-019-00152-8","article-title":"Complications of temporary percutaneous mechanical circulatory support for cardiogenic shock: An appraisal of contemporary literature.","volume":"8","author":"Subramaniam","year":"2019","journal-title":"Cardiol Ther"},{"key":"R5-20240807","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1177\/0897190018822105","article-title":"Anticoagulation of a percutaneous left ventricular assist device using a low-dose heparin purge solution protocol: A case series.","volume":"33","author":"Newsome","year":"2020","journal-title":"J Pharm Pract"},{"key":"R6-20240807","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1002\/clc.20694","article-title":"Clinical implications of thrombocytopenia among patients undergoing intra-aortic balloon pump counterpulsation in the coronary care unit.","volume":"33","author":"Roy","year":"2010","journal-title":"Clin Cardiol"},{"key":"R7-20240807","doi-asserted-by":"crossref","first-page":"e7","DOI":"10.1016\/j.jacc.2015.03.036","article-title":"2015 SCAI\/ACC\/HFSA\/STS clinical expert consensus statement on the use of percutaneous mechanical circulatory support devices in cardiovascular care: Endorsed by the American Heart Assocation, the Cardiological Society of India, and sociedad latino americana de cardiologia intervencion; affirmation of value by the Canadian Association of Interventional Cardiology-Association canadienne de Cardiologie d\u2019intervention.","volume":"65","author":"Rihal","year":"2015","journal-title":"J Am Coll Cardiol"},{"issue":"9 Suppl 1","key":"R8-20240807","doi-asserted-by":"crossref","first-page":"1212","DOI":"10.1016\/S0735-1097(19)31819-4","article-title":"Incidence of heparin-induced thrombocytopenia in patients with newly-implanted mechanical circulatory support devices.","volume":"73","author":"Attar","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"R9-20240807","doi-asserted-by":"crossref","first-page":"4160","DOI":"10.1182\/blood-2012-07-443051","article-title":"Predictive value of the 4Ts scoring system for heparin-induced thrombocytopenia: A systematic review and meta-analysis.","volume":"120","author":"Cuker","year":"2012","journal-title":"Blood"},{"key":"R10-20240807","doi-asserted-by":"crossref","first-page":"575","DOI":"10.1136\/pgmj.2007.059188","article-title":"Heparin induced thrombocytopenia: Diagnosis and management update.","volume":"83","author":"Ahmed","year":"2007","journal-title":"Postgrad Med J"},{"key":"R11-20240807","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1097\/MAT.0000000000000290","article-title":"Incidence of hemolysis in patients with cardiogenic shock treated with impella percutaneous left ventricular assist device.","volume":"62","author":"Badiye","year":"2016","journal-title":"ASAIO J"},{"key":"R12-20240807","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1177\/0897190017727191","article-title":"Anticoagulation of percutaneous ventricular assist device using argatroban-based purge solution: A case series.","volume":"31","author":"Blum","year":"2018","journal-title":"J Pharm Pract"},{"key":"R13-20240807","doi-asserted-by":"crossref","first-page":"e163","DOI":"10.2146\/ajhp160212","article-title":"Use of an argatroban-based purge solution in a percutaneous ventricular assist device.","volume":"74","author":"Laliberte","year":"2017","journal-title":"Am J Health Syst Pharm"},{"key":"R14-20240807","doi-asserted-by":"crossref","first-page":"e117","DOI":"10.1097\/MAT.0000000000001126","article-title":"Anticoagulation of impella with a bivalirudin purge solution.","volume":"66","author":"Szymanski","year":"2020","journal-title":"ASAIO J"},{"key":"R15-20240807","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1177\/0391398820964810","article-title":"Anticoagulation with temporary Impella device in patients with heparin-induced thrombocytopenia: A case series.","volume":"44","author":"Hohlfelder","year":"2021","journal-title":"Int J Artif Organs"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000772","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T14:15:10Z","timestamp":1723040110000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000772"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,10]]},"references-count":15,"journal-issue":{"issue":"10","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000000772","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,10]]}}}