{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T04:17:55Z","timestamp":1780719475823,"version":"3.54.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"12","license":[{"start":{"date-parts":[[2022,12,1]],"date-time":"2022-12-01T00:00:00Z","timestamp":1669852800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>We aimed to examine the associations between use of cuffed or uncuffed endotracheal tubes (ETTs) and complications during and after short-term intubation of post-palatoplasty patients without intrinsic lung disease.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Retrospective cohort study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Operating room and PICU.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Children without intrinsic lung disease who had undergone palatoplasty at a single institution. Inclusion criteria: intubation using ETTs with an internal diameter of 3.5\u2009mm and postoperative management in the PICU. Exclusion criteria: 1) patients for whom ETTs with internal diameters other than 3.5\u2009mm were used, 2) patients who had already been extubated in the operating room, and 3) patients who had a tracheostomy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>None.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Eighty-seven patients were screened for eligibility; 71 met the inclusion criteria. Of the 71 patients, 41 (58%) with polyurethane-cuffed ETTs (PUC-ETTs) and 30 (42%) with uncuffed ETTs were enrolled. We failed to identify an association between type of PUC-ETT and the development of atelectasis (odds ratio [OR], 1.06; 95% CI, 0.35\u20133.20; <jats:italic toggle=\"yes\">p<\/jats:italic> = 1.00). Similarly, we failed to identify an association between type of PUC-ETT and development of stridor (OR, 1.58; 95% CI, 0.43\u20135.81; <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.715) or hoarseness after extubation (OR, 7.03; 95% CI, 0.83\u201359.6; <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.10). At extubation, air leak pressure was higher in the PUC-ETT group than in the uncuffed ETT group (<jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.001), a finding which was not evident at intubation. The number of patients who received IV dexamethasone and the cases of inhaled racemic epinephrine were not statistically significant.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>In this select population of post-palatoplasty infants without intrinsic lung disease, we failed to identify any association between type of ETT (cuffed or uncuffed) and greater odds of developing respiratory complications. Taken together with the 95% CI of the effect size, our data indicate continued uncertainty about type of ETT that should be used for short-term intubation.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000000817","type":"journal-article","created":{"date-parts":[[2023,10,19]],"date-time":"2023-10-19T19:06:43Z","timestamp":1697742403000},"page":"e0817","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Respiratory Complications Between Cuffed and Uncuffed Endotracheal Tubes in Pediatric Respiratory Management After Palatoplasty: Single-Center Retrospective Cohort Study"],"prefix":"10.1097","volume":"4","author":[{"given":"Hironori","family":"Minoura","sequence":"first","affiliation":[{"name":"Department of Pediatric Intensive Care, Nagano Children\u2019s Hospital, Nagano, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takashi","family":"Ichino","sequence":"additional","affiliation":[{"name":"Department of Anesthesia, Nagano Children\u2019s Hospital, Nagano, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Masatomo","family":"Kitamura","sequence":"additional","affiliation":[{"name":"Department of Pediatric Intensive Care, Nagano Children\u2019s Hospital, Nagano, Japan."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,12,14]]},"reference":[{"key":"R1-20240807","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1097\/00000542-199703000-00015","article-title":"Comparison of cuffed and uncuffed endotracheal tubes in young children during general anesthesia.","volume":"86","author":"Khine","year":"1997","journal-title":"Anesthesiology"},{"key":"R2-20240807","doi-asserted-by":"crossref","first-page":"333","DOI":"10.1016\/j.jpeds.2003.12.018","article-title":"The use of cuffed versus uncuffed endotracheal tubes in pediatric intensive care.","volume":"144","author":"Newth","year":"2004","journal-title":"J Pediatr"},{"key":"R3-20240807","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1111\/pan.12528","article-title":"Pediatric airway anatomy may not be what we thought: Implications for clinical practice and the use of cuffed endotracheal tubes.","volume":"25","author":"Tobias","year":"2015","journal-title":"Paediatr Anaesth"},{"key":"R4-20240807","doi-asserted-by":"crossref","first-page":"280","DOI":"10.1016\/j.jcrc.2010.05.035","article-title":"A polyurethane cuffed endotracheal tube is associated with decreased rates of ventilator-associated pneumonia.","volume":"26","author":"Miller","year":"2011","journal-title":"J Crit Care"},{"key":"R5-20240807","doi-asserted-by":"crossref","first-page":"203","DOI":"10.1186\/s13054-016-1380-8","article-title":"The value of polyurethane-cuffed endotracheal tubes to reduce microaspiration and intubation-related pneumonia: A systematic review of laboratory and clinical studies.","volume":"20","author":"Blot","year":"2016","journal-title":"Crit Care"},{"key":"R6-20240807","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.jtcvs.2007.08.052","article-title":"Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: A pilot study.","volume":"135","author":"Poelaert","year":"2008","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R7-20240807","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1111\/pan.13340","article-title":"The incidence of postoperative respiratory complications: A retrospective analysis of cuffed vs uncuffed tracheal tubes in children 0-7 years of age.","volume":"28","author":"de Wit","year":"2018","journal-title":"Paediatr Anaesth"},{"key":"R8-20240807","doi-asserted-by":"crossref","first-page":"614F614","DOI":"10.1136\/archdischild-2020-320764","article-title":"Comparison of the efficacy and safety of cuffed versus uncuffed endotracheal tubes for infants in the intensive care setting: A pilot, unblinded RCT.","volume":"106","author":"Thomas","year":"2021","journal-title":"Arch Dis Child Fetal Neonatal Ed"},{"key":"R9-20240807","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1007\/s00540-015-2093-x","article-title":"Postoperative complications associated with extubation strategies following palatoplasty: A single-center retrospective analysis.","volume":"30","author":"Kishimoto","year":"2016","journal-title":"J Anesth"},{"key":"R10-20240807","doi-asserted-by":"crossref","first-page":"1","DOI":"10.18637\/jss.v014.i09","article-title":"The R commander: A basic-statistics graphical user interface to R.","volume":"14","author":"Fox","year":"2005","journal-title":"J Stat Soft"},{"key":"R11-20240807","doi-asserted-by":"crossref","first-page":"452","DOI":"10.1038\/bmt.2012.244","article-title":"Investigation of the freely available easy-to-use software \u201cEZR\u201d for medical statistics.","volume":"48","author":"Kanda","year":"2013","journal-title":"Bone Marrow Transplant"},{"key":"R12-20240807","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1111\/pan.13311","article-title":"Cuffed endotracheal tubes in infants less than 3 kg: A retrospective cohort study.","volume":"28","author":"Thomas","year":"2018","journal-title":"Paediatr Anaesth"},{"key":"R13-20240807","doi-asserted-by":"crossref","first-page":"1656","DOI":"10.1007\/s00134-011-2349-3","article-title":"Ventilator-associated pneumonia in children after cardiac surgery in The Netherlands.","volume":"37","author":"Roeleveld","year":"2011","journal-title":"Intensive Care Med"},{"key":"R14-20240807","doi-asserted-by":"crossref","first-page":"867","DOI":"10.1093\/bja\/aep290","article-title":"Prospective randomized controlled multi-centre trial of cuffed or uncuffed endotracheal tubes in small children.","volume":"103","author":"Weiss","year":"2009","journal-title":"Br J Anaesth"},{"key":"R15-20240807","doi-asserted-by":"crossref","first-page":"13","DOI":"10.4103\/0970-9185.105786","article-title":"Pediatric cuffed endotracheal tubes.","volume":"29","author":"Bhardwaj","year":"2013","journal-title":"J Anaesthesiol Clin Pharmacol"},{"key":"R16-20240807","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13613-015-0087-3","article-title":"Continuous control of tracheal cuff pressure for VAP prevention: A collaborative meta-analysis of individual participant data.","volume":"5","author":"Nseir","year":"2015","journal-title":"Ann Intensive Care"},{"key":"R17-20240807","doi-asserted-by":"crossref","first-page":"1430","DOI":"10.1097\/CCM.0000000000005630","article-title":"Effectiveness of continuous cuff pressure control in preventing ventilator-associated pneumonia: A systematic review and meta-analysis of randomized controlled trials.","volume":"50","author":"Maertens","year":"2022","journal-title":"Crit Care Med"},{"key":"R18-20240807","doi-asserted-by":"crossref","first-page":"181","DOI":"10.5005\/jp-journals-10071-23737","article-title":"Utility of endotracheal tube cuff pressure monitoring in mechanically ventilated (MV) children in preventing post-extubation stridor (PES).","volume":"25","author":"Shaikh","year":"2021","journal-title":"Indian J Crit Care Med"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000817","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T14:16:10Z","timestamp":1723040170000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000817"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12]]},"references-count":18,"journal-issue":{"issue":"12","published-online":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000000817","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,12]]}}}