{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,25]],"date-time":"2026-09-25T01:52:13Z","timestamp":1790301133463,"version":"4.1.0"},"reference-count":43,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2023,1,1]],"date-time":"2023-01-01T00:00:00Z","timestamp":1672531200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>Guidewire retention after intravascular catheter insertion is considered a \u201cnever event.\u201d Prior reports attribute this complication to various characteristics including uncooperative patients, operator inexperience, off-hour or emergent insertion, and underutilization of ultrasound guidance. In this descriptive analysis of consecutive events, we assessed the frequency of patient, operator, and procedural factors in guidewire retention.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Pre-specified observational analysis as part of a quality improvement study of consecutive guidewire retention events across a multihospital health system from August 2007 to October 2015.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Ten hospitals within the Cleveland Clinic Health System in Ohio, United States.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Consecutive all-comers who experienced guidewire retention after vascular catheter insertion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>None.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Data were manually obtained from the electronic medical records and reviewed for potential contributing factors for guidewire retention, stratified into patient, operator, and procedural characteristics. A total of 24 events were identified. Overall, the median age was 74 years, 58% were males, and the median body mass index was 26.5\u2009kg\/m<jats:sup>2<\/jats:sup>. A total of 12 (50%) individuals were sedated during the procedure. Most incidents (10 [42%]) occurred in internal jugular venous access sites. The majority of cases (13 [54%]) were performed or supervised by an attending. Among all cases, three (12%) were performed by first-year trainees, seven (29%) by residents, three (12%) by fellows, and four (17%) by certified nurse practitioners. Overall, 16 (67%) events occurred during regular working hours (8 <jats:sc>am<\/jats:sc>to 5 <jats:sc>pm<\/jats:sc>). In total, 22 (92%) guidewires were inserted nonemergently, with two (8%) during a cardiac arrest. Ultrasound guidance was used in all but one case.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>Guidewire retention can occur even in the presence of optimal patient, operator, and procedural circumstances, highlighting the need for constant awareness of this risk. Efforts to eliminate this important complication will require attention to issues surrounding the technical performance of the procedure.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000000834","type":"journal-article","created":{"date-parts":[[2023,1,26]],"date-time":"2023-01-26T14:24:20Z","timestamp":1674743060000},"page":"e0834","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Patient, Operator, and Procedural Characteristics of Guidewire Retention as a Complication of Vascular Catheter Insertion"],"prefix":"10.1097","volume":"5","author":[{"given":"Nicholas","family":"Kassis","sequence":"first","affiliation":[{"name":"Division of Cardiology, Lifespan Cardiovascular Institute, Warren Alpert Medical School of Brown University, Providence, RI."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Laith","family":"Alkukhun","sequence":"additional","affiliation":[{"name":"Knight Cardiovascular Institute, Oregon Health & Science University, Portland, OR."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kathleen","family":"Kravitz","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolyn","family":"Miclea","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amanjit","family":"Gill","sequence":"additional","affiliation":[{"name":"Department of Diagnostic Radiology, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiedozie I.","family":"Udeh","sequence":"additional","affiliation":[{"name":"Department of Intensive Care and Resuscitation, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piyush","family":"Mathur","sequence":"additional","affiliation":[{"name":"Department of Intensive Care and Resuscitation, Anesthesiology Institute, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron C.","family":"Hamilton","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sean P.","family":"Lyden","sequence":"additional","affiliation":[{"name":"Department of Vascular Surgery, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samir R.","family":"Kapadia","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Umesh N.","family":"Khot","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Heart, Vascular and Thoracic Institute, Cleveland Clinic, Cleveland, OH."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2023,1,9]]},"reference":[{"key":"R1-20240807","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1056\/NEJMra011883","article-title":"Preventing complications of central venous catheterization.","volume":"348","author":"McGee","year":"2003","journal-title":"N Engl J Med"},{"key":"R2-20240807","doi-asserted-by":"crossref","first-page":"368","DOI":"10.3109\/00016925309136722","article-title":"Catheter replacement of the needle in percutaneous arteriography; a new technique.","volume":"39","author":"Seldinger","year":"1953","journal-title":"Acta Radiol"},{"key":"R3-20240807","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.jclinane.2011.07.003","article-title":"A potentially hazardous complication during central venous catheterization: Lost guidewire retained in the patient.","volume":"24","author":"Song","year":"2012","journal-title":"J Clin Ane"},{"key":"R4-20240807","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1053\/j.jvca.2012.11.017","article-title":"Difficulty in the diagnosis of a retained guidewire within the central venous catheter.","volume":"27","author":"Umesh","year":"2013","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R5-20240807","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.java.2013.12.001","article-title":"Guidewires unintentionally retained during central venous catheterization.","volume":"19","author":"Williams","year":"2014","journal-title":"JAVA"},{"key":"R6-20240807","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1197\/j.aem.2005.02.014","article-title":"Profiles in patient safety: Misplaced femoral line guidewire and multiple failures to detect the foreign body on chest radiography.","volume":"12","author":"Lum","year":"2005","journal-title":"Acad Emerg Med"},{"key":"R7-20240807","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1213\/ANE.0b013e3182599179","article-title":"Retained guidewires after intraoperative placement of central venous catheters.","volume":"117","author":"Vannucci","year":"2013","journal-title":"Anesth Analg"},{"key":"R8-20240807","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1016\/j.clinimag.2005.12.024","article-title":"Unsuspected retained 60-cm intravenous guidewire.","volume":"30","author":"Cassie","year":"2006","journal-title":"Clin Imaging"},{"key":"R9-20240807","first-page":"287261","article-title":"Guidewire-related complications during central venous catheter placement: A case report and review of the literature.","volume":"2011","author":"Khasawneh","year":"2011","journal-title":"Case Rep Crit Care"},{"key":"R10-20240807","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1097\/00000542-199601000-00039","article-title":"Unrecognized migration of an entire guidewire on insertion of a central venous catheter into the cardiovascular system.","volume":"84","author":"Akazawa","year":"1996","journal-title":"Anesthesiology"},{"key":"R11-20240807","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1016\/j.ajem.2013.07.009","article-title":"The incidence of retained guidewires after central venous catheterization in a tertiary care center.","volume":"31","author":"Omar","year":"2013","journal-title":"Am J Emerg Med"},{"key":"R12-20240807","doi-asserted-by":"crossref","first-page":"144","DOI":"10.1093\/bja\/88.1.144","article-title":"Loss of the guide wire: Mishap or blunder?","volume":"88","author":"Schummer","year":"2002","journal-title":"Br J Anaesth"},{"key":"R13-20240807","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1016\/j.jamcollsurg.2007.01.039","article-title":"Complications of central venous catheterization.","volume":"204","author":"Kusminsky","year":"2007","journal-title":"J Am Coll Surg"},{"key":"R14-20240807","first-page":"38","article-title":"Retrieval of a wire lost during central venous catheter replacement.","author":"Bream","year":"2008","journal-title":"Endovasc Today"},{"key":"R15-20240807","doi-asserted-by":"crossref","first-page":"527","DOI":"10.2214\/ajr.180.2.1800527","article-title":"Experience at a single institution with endovascular treatment of mechanical complications caused by implanted central venous access devices in pediatric and adult patients.","volume":"180","author":"Bessoud","year":"2003","journal-title":"AJR Am J Roentgenol"},{"key":"R16-20240807","first-page":"440","article-title":"Percutaneous retrieval of chronic intravascular foreign bodies.","volume":"26","author":"Savage","year":"2003","journal-title":"Carviovasc Intervent Radiol"},{"key":"R17-20240807","doi-asserted-by":"crossref","first-page":"772","DOI":"10.1097\/00000542-199010000-00024","article-title":"Guide wire as a cause of complete heart block in patients with preexisting left bundle branch block.","volume":"73","author":"Eissa","year":"1990","journal-title":"Anesthesiology"},{"key":"R18-20240807","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1177\/0148607190014002152","article-title":"Incidence of arrhythmia with central venous catheter insertion and exchange.","volume":"14","author":"Stuart","year":"1990","journal-title":"JPEN J Parenter Enteral Nutr"},{"key":"R19-20240807","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1007\/s00540-008-0696-1","article-title":"Life-threatening hemothorax resulting from right brachiocephalic vein perforation during right internal jugular vein catheterization.","volume":"23","author":"Innami","year":"2009","journal-title":"J Anesth"},{"key":"R20-20240807","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/S0952-8180(01)00229-X","article-title":"An unusual complication during central venous catheter placement.","volume":"13","author":"Duong","year":"2001","journal-title":"J Clin Anesth"},{"key":"R21-20240807","first-page":"87","article-title":"J-tip spring guidewire entrapment by an inferior vena cava filter.","volume":"104","author":"Vinces","year":"2004","journal-title":"J Am Osteopath Assoc"},{"key":"R22-20240807","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1177\/039139888901200208","article-title":"Cardiac perforation by a guide wire during subclavian catheter insertion.","volume":"12","author":"Blake","year":"1989","journal-title":"Int J Artif Organs"},{"key":"R23-20240807","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1159\/000045064","article-title":"Fatal pericardial tamponade by a guide wire during jugular catheter insertion.","volume":"79","author":"Cavatorta","year":"1998","journal-title":"Nephron"},{"key":"R24-20240807","first-page":"e629","article-title":"Images in cardiovascular medicine. Percutaneous retrieval of a lost guidewire that caused cardiac tamponade.","volume":"115","author":"Perez-Diez","year":"2007","journal-title":"Circulation"},{"key":"R25-20240807","doi-asserted-by":"crossref","first-page":"751.e15","DOI":"10.1016\/j.cjca.2012.12.010","article-title":"A forgotten guidewire causing intracardiac multiple thrombi with paradoxical and pulmonary embolism.","volume":"29","author":"Gulel","year":"2013","journal-title":"Can J Cardiol"},{"key":"R26-20240807","doi-asserted-by":"crossref","first-page":"2388","DOI":"10.1056\/NEJMp0809125","article-title":"Ending extra payment for \u201cnever events\u201d--stronger incentives for patients\u2019 safety.","volume":"360","author":"Milstein","year":"2009","journal-title":"N Engl J Med"},{"key":"R27-20240807","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1056\/NEJMp078184","article-title":"Nonpayment for performance? Medicare\u2019s new reimbursement rule.","volume":"357","author":"Rosenthal","year":"2007","journal-title":"N Engl J Med"},{"key":"R29-20240807","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1016\/j.cursur.2003.07.010","article-title":"Is routine ultrasound guidance for central line placement beneficial? A prospective analysis.","volume":"61","author":"Martin","year":"2004","journal-title":"Curr Surg"},{"key":"R30-20240807","doi-asserted-by":"crossref","first-page":"602","DOI":"10.1136\/hrt.2005.074344","article-title":"Images in cardiology. Guidewire loss: Mishap or blunder?","volume":"92","author":"Guo","year":"2006","journal-title":"Heart"},{"key":"R31-20240807","doi-asserted-by":"crossref","first-page":"801","DOI":"10.1007\/BF03021773","article-title":"Broken guide wire--a fault of design?","volume":"52","author":"Monaca","year":"2005","journal-title":"Can J Anaesth"},{"key":"R32-20240807","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.jss.2012.02.053","article-title":"Intravascular retained surgical items: A multicenter study of risk factors.","volume":"178","author":"Moffatt-Bruce","year":"2012","journal-title":"J Surg Res"},{"key":"R33-20240807","doi-asserted-by":"crossref","first-page":"23","DOI":"10.3233\/JRS-140610","article-title":"Guidewire retention following central venous catheterisation: A human factors and safe design investigation.","volume":"26","author":"Horberry","year":"2014","journal-title":"Int J Risk Saf Med"},{"key":"R34-20240807","doi-asserted-by":"crossref","first-page":"1220","DOI":"10.1056\/NEJMoa1500964","article-title":"Intravascular complications of central venous catheterization by insertion site.","volume":"373","author":"Parienti","year":"2005","journal-title":"N Engl J Med"},{"key":"R35-20240807","doi-asserted-by":"crossref","first-page":"397","DOI":"10.1186\/cc2179","article-title":"What is the best site for central venous catheter insertion in critically ill patients?","volume":"7","author":"Timsit","year":"2003","journal-title":"Crit Care"},{"key":"R36-20240807","doi-asserted-by":"crossref","first-page":"658","DOI":"10.1097\/ALN.0000000000001797","article-title":"Preventing retained central venous catheter guidewire: A randomized controlled simulation study using a human factors approach.","volume":"127","author":"Mariyaselvam","year":"2017","journal-title":"Anesthesiology"},{"key":"R37-20240807","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1097\/CCM.0000000000001012","article-title":"Missed central venous guide wires: A systematic analysis of published case reports.","volume":"43","author":"Pokharel","year":"2015","journal-title":"Crit Care Med"},{"key":"R38-20240807","doi-asserted-by":"crossref","first-page":"1942","DOI":"10.3389\/fpsyg.2017.01942","article-title":"Intuitive choices lead to intensified positive emotions: An overlooked reason for \u201cintuitive bias?\u201d.","volume":"8","author":"Kirkeb\u00f8en","year":"2017","journal-title":"Front Psychol"},{"key":"R39-20240807","doi-asserted-by":"crossref","first-page":"389","DOI":"10.4300\/JGME-D-10-00007.1","article-title":"Creating and evaluating a data-driven curriculum for central venous catheter placement.","volume":"2","author":"Duncan","year":"2010","journal-title":"J Grad Med Educ"},{"key":"R40-20240807","doi-asserted-by":"crossref","first-page":"78","DOI":"10.4103\/2006-8808.128732","article-title":"Loss of guide wire: A lesson learnt review of literature.","volume":"5","author":"Srivastav","year":"2013","journal-title":"J Surg Tech Case Rep"},{"key":"R41-20240807","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1097\/00003246-198104000-00014","article-title":"Guide wires \u2013 a caution.","volume":"9","author":"Schwartz","year":"1981","journal-title":"Crit Care Med"},{"key":"R42-20240807","doi-asserted-by":"crossref","first-page":"e21","DOI":"10.1056\/NEJMvcm055053","article-title":"Central venous catheterization.","volume":"356","author":"Graham","year":"2007","journal-title":"N Eng J Med"},{"key":"R43-20240807","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1097\/ALN.0b013e31823c9569","article-title":"Practice guidelines for central venous access: A report by the American Society of Anesthesiologists Task Force on Central Venous Access.","volume":"116","author":"Rupp","year":"2012","journal-title":"Anesthesiology"},{"key":"R44-20240807","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/ALN.0000000000002864","article-title":"Practice guidelines for central venous access 2020: An updated report by the American Society of Anesthesiologists Task Force on Central Venous Access.","volume":"132","year":"2020","journal-title":"Anesthesiology"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000834","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T14:14:23Z","timestamp":1723040063000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000000834"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,1]]},"references-count":43,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2023]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000000834","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2023,1]]}}}