{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,17]],"date-time":"2026-11-17T23:35:19Z","timestamp":1794958519822,"version":"4.9.1"},"reference-count":15,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","license":[{"start":{"date-parts":[[2024,1,1]],"date-time":"2024-01-01T00:00:00Z","timestamp":1704067200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>To assess the feasibility of setting the tidal volume (TV) as 25% of the actual aerated lung volume (rather than on ideal body weight) in patients with Acute Respiratory Distress Syndrome (ARDS).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Physiologic prospective single-center pilot study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Medical ICU specialized in the care of patients with ARDS.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Patients with moderate-severe ARDS deeply sedated or paralyzed, undergoing controlled mechanical ventilation with a ventilator able to measure the end-expiratory lung volume (EELV) with a washin, washout technique.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>Three-phase study (baseline, strain-selected TV setting, ventilation with strain-selected TV for 24\u2009hr). The TV was calculated as 25% of the measured EELV minus the static strain due to the applied positive end-expiratory pressure.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Gas exchanges and respiratory mechanics were measured and compared in each phase. In addition, during the TV setting phase, driving pressure (DP) and lung strain (TV\/EELV) were measured at different TVs to assess the correlation between the two measurements. The maintenance of the set strain-selected TV for 24 hours was safe and feasible in 76% of the patients enrolled. Three patients dropped out from the study because of the need to set a respiratory rate higher than 35 breaths per minute to avoid respiratory acidosis. The DP of the respiratory system was a satisfactory surrogate for strain in this population.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>In our population of 17 patients with moderate to severe ARDS, setting TV based on the actual lung size was feasible. DP was a reliable surrogate of strain in these patients, and DP less than or equal to 8\u2009cm H<jats:sub>2<\/jats:sub>O corresponded to a strain less than 0.25.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000001031","type":"journal-article","created":{"date-parts":[[2024,1,16]],"date-time":"2024-01-16T19:28:23Z","timestamp":1705433303000},"page":"e1031","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":3,"title":["Feasibility of Setting the Tidal Volume Based on End-Expiratory Lung Volume: A Pilot Clinical Study"],"prefix":"10.1097","volume":"6","author":[{"given":"Alice","family":"Grassi","sequence":"first","affiliation":[{"name":"Department of Anesthesiology and Pain Medicine, University of Toronto, Toronto General Hospital, University Health Network, Toronto, ON, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maddalena","family":"Teggia-Droghi","sequence":"additional","affiliation":[{"name":"Department of Emergency and Intensive Care, San Gerardo Hospital, Monza, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Asia","family":"Borgo","sequence":"additional","affiliation":[{"name":"School of Medicine and Surgery, University of Milan-Bicocca, Monza, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Konstanty","family":"Szudrinsky","sequence":"additional","affiliation":[{"name":"Department of Anaesthesiology and Intensive Care, National Institute of Medicine of the Ministry of Interior and Administration in Warsaw, Warszawa, Poland."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Giacomo","family":"Bellani","sequence":"additional","affiliation":[{"name":"Department of Anesthesia and Intensive Care, Santa Chiara Hospital, APSS Trento, Trento, Italy."},{"name":"Centre for Medical Sciences CISMed, University of Trento, Trento, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,1,16]]},"reference":[{"key":"R1-20240806","doi-asserted-by":"crossref","first-page":"776","DOI":"10.1007\/s00134-005-2627-z","article-title":"The concept of \u201cbaby lung\u201d.","volume":"31","author":"Gattinoni","year":"2005","journal-title":"Intensive Care Med"},{"key":"R2-20240806","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1164\/rccm.200710-1589OC","article-title":"Lung stress and strain during mechanical ventilation for acute respiratory distress syndrome.","volume":"178","author":"Chiumello","year":"2008","journal-title":"Am J Respir Crit Care Med"},{"key":"R3-20240806","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.1164\/rccm.201008-1318OC","article-title":"Lung regional metabolic activity and gas volume changes induced by tidal ventilation in patients with acute lung injury.","volume":"183","author":"Bellani","year":"2011","journal-title":"Am J Respir Crit Care Med"},{"key":"R4-20240806","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1007\/s00134-011-2403-1","article-title":"Lung strain and biological response in mechanically ventilated patients.","volume":"38","author":"Gonz\u00e1lez-L\u00f3pez","year":"2012","journal-title":"Intensive Care Med"},{"key":"R5-20240806","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1007\/s00134-023-07050-7","article-title":"European Society of Intensive Care Medicine Taskforce on ARDS. ESICM guidelines on acute respiratory distress syndrome: definition, phenotyping and respiratory support strategies.","volume":"49","author":"Grasselli","year":"2023","journal-title":"Intensive Care Med"},{"key":"R6-20240806","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1056\/NEJMsa1410639","article-title":"Driving pressure and survival in the acute respiratory distress syndrome.","volume":"372","author":"Amato","year":"2015","journal-title":"N Engl J Med"},{"key":"R7-20240806","first-page":"2526","article-title":"Acute respiratory distress syndrome: The Berlin definition.","volume":"307","author":"Ranieri","year":"2012","journal-title":"JAMA"},{"key":"R8-20240806","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/s13054-019-2695-z","article-title":"How I set up positive end-expiratory pressure: Evidence-and physiology-based!","volume":"23","author":"Rezoagli","year":"2019","journal-title":"Crit Care"},{"key":"R9-20240806","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1097\/00003246-198208000-00010","article-title":"Oxygen wash-in method for monitoring functional residual capacity.","volume":"10","author":"Mitchell","year":"1982","journal-title":"Crit Care Med"},{"key":"R10-20240806","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1213\/01.ANE.0000165823.90368.55","article-title":"Estimation of functional residual capacity at the bedside using standard monitoring equipment: A modified nitrogen washout\/washin technique requiring a small change of the inspired oxygen fraction.","volume":"101","author":"Oleg\u00e5rd","year":"2005","journal-title":"Anesth Analg"},{"key":"R11-20240806","doi-asserted-by":"crossref","first-page":"912","DOI":"10.1007\/s00134-007-0578-2","article-title":"Determination of functional residual capacity by oxygen washin-washout: A validation study.","volume":"33","author":"Maisch","year":"2007","journal-title":"Intensive Care Med"},{"key":"R12-20240806","doi-asserted-by":"crossref","first-page":"R150","DOI":"10.1186\/cc7139","article-title":"Nitrogen washout\/washin, helium dilution and computed tomography in the assessment of end expiratory lung volume.","volume":"12","author":"Chiumello","year":"2008","journal-title":"Crit Care"},{"key":"R13-20240806","first-page":"1301","article-title":"Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome.","volume":"342","year":"2001","journal-title":"NEJM"},{"key":"R14-20240806","doi-asserted-by":"crossref","first-page":"1378","DOI":"10.1164\/rccm.202009-3536OC","article-title":"Effect of lowering vt on mortality in acute respiratory distress syndrome varies with respiratory system elastance.","volume":"203","author":"Goligher","year":"2021","journal-title":"Am J Respir Crit Care Med"},{"key":"R15-20240806","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/s13054-017-1600-x","article-title":"The effects of low tidal ventilation on lung strain correlate with respiratory system compliance.","volume":"21","author":"Xie","year":"2017","journal-title":"Crit Care"}],"updated-by":[{"DOI":"10.1097\/cce.0000000000001074","type":"correction","label":"Correction","source":"publisher","updated":{"date-parts":[[2024,4,9]],"date-time":"2024-04-09T00:00:00Z","timestamp":1712620800000}}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001031","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,7]],"date-time":"2024-08-07T00:07:00Z","timestamp":1722989220000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001031"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,1]]},"references-count":15,"journal-issue":{"issue":"1","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000001031","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,1]]}}}