{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T07:29:31Z","timestamp":1790666971740,"version":"4.1.0"},"reference-count":29,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","license":[{"start":{"date-parts":[[2024,5,1]],"date-time":"2024-05-01T00:00:00Z","timestamp":1714521600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"Helene Fuld Institute"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>IMPORTANCE:<\/jats:title>\n            <jats:p>Patients admitted with cerebral hemorrhage or cerebral edema often undergo external ventricular drain (EVD) placement to monitor and manage intracranial pressure (ICP). A strain gauge transducer accompanies the EVD to convert a pressure signal to an electrical waveform and assign a numeric value to the ICP.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>This study explored ICP accuracy in the presence of blood and other viscous fluid contaminates in the transducer.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Preclinical comparative design study.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Laboratory setting using two Natus EVDs, two strain gauge transducers, and a sealed pressure chamber.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PARTICIPANTS:<\/jats:title>\n            <jats:p>No human subjects or animal models were used.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>A control transducer primed with saline was compared with an investigational transducer primed with blood or with saline\/glycerol mixtures in mass:mass ratios of 25%, 50%, 75%, and 100% glycerol. Volume in a sealed chamber was manipulated to reflect changes in ICP to explore the impact of contaminates on pressure measurement.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>From 90 paired observations, ICP readings were statistically significantly different between the control (saline) and experimental (glycerol or blood) transducers. The time to a stable pressure reading was significantly different for saline vs. 25% glycerol (&lt; 0.0005), 50% glycerol (&lt; 0.005), 75% glycerol (&lt; 0.0001), 100% glycerol (&lt; 0.0005), and blood (&lt; 0.0005). A difference in resting stable pressure was observed for saline vs. blood primed transducers (0.041).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS AND RELEVANCE:<\/jats:title>\n            <jats:p>There are statistically significant and clinically relevant differences in time to a stable pressure reading when contaminates are introduced into a closed drainage system. Changing a transducer based on the presence of blood contaminate should be considered to improve accuracy but must be weighed against the risk of introducing infection.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000001089","type":"journal-article","created":{"date-parts":[[2024,5,10]],"date-time":"2024-05-10T16:00:44Z","timestamp":1715356844000},"page":"e1089","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":4,"title":["The Presence of Blood in a Strain Gauge Pressure Transducer Has a Clinical Effect on the Accuracy of Intracranial Pressure Readings"],"prefix":"10.1097","volume":"6","author":[{"given":"Emerson B.","family":"Nairon","sequence":"first","affiliation":[{"name":"Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeslin","family":"Joseph","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Abdulkadir","family":"Kamal","sequence":"additional","affiliation":[{"name":"Department of Nursing, University of Texas Southwestern Medical Center, Dallas, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David R.","family":"Busch","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX."},{"name":"Department of Anesthesiology and Pain Management, University of Texas Southwestern Medical Center, Dallas, TX."},{"name":"Department of Biomedical Engineering, University of Texas Southwestern Medical Center, Dallas, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"DaiWai M.","family":"Olson","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Texas Southwestern Medical Center, Dallas, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,5,9]]},"reference":[{"key":"R1-20240806","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1097\/JNN.0000000000000691","article-title":"Zeroing a transducer on an external ventricular drain.","volume":"55","author":"Malloy","year":"2023","journal-title":"J Neurosci Nurs"},{"key":"R2-20240806","doi-asserted-by":"crossref","first-page":"e3","DOI":"10.1056\/NEJMvcm1805314","article-title":"Placement of an external ventricular drain.","volume":"384","author":"Dossani","year":"2021","journal-title":"N Engl J Med"},{"key":"R3-20240806","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jradnu.2019.01.004","article-title":"Management of external ventricular drains during intrahospital transport for radiographic imaging.","volume":"38","author":"Stout","year":"2019","journal-title":"J Radiol Nurs"},{"key":"R4-20240806","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1007\/s11910-019-1009-9","article-title":"Evidence-based management of external ventricular drains.","volume":"19","author":"Chung","year":"2019","journal-title":"Curr Neurol Neurosci Rep"},{"key":"R5-20240806","doi-asserted-by":"crossref","first-page":"S85","DOI":"10.1007\/s12028-014-0040-6","article-title":"Intracranial pressure and cerebral perfusion pressure monitoring in non-TBI patients: Special considerations.","volume":"21","author":"Helbok","year":"2014","journal-title":"Neurocrit Care"},{"key":"R6-20240806","doi-asserted-by":"crossref","first-page":"974","DOI":"10.3171\/2013.6.JNS122403","article-title":"Continuous cerebral spinal fluid drainage associated with complications in patients admitted with subarachnoid hemorrhage.","volume":"119","author":"Olson","year":"2013","journal-title":"J Neurosurg"},{"key":"R7-20240806","doi-asserted-by":"crossref","first-page":"1583","DOI":"10.3171\/2019.1.JNS182702","article-title":"Intermittent CSF drainage and rapid EVD weaning approach after subarachnoid hemorrhage: Association with fewer VP shunts and shorter length of stay.","volume":"132","author":"Rao","year":"2019","journal-title":"J Neurosurg"},{"key":"R8-20240806","doi-asserted-by":"crossref","first-page":"536","DOI":"10.1007\/s12028-021-01343-9","article-title":"Association of external ventricular drain wean strategy with shunt placement and length of stay in subarachnoid hemorrhage: A prospective multicenter study.","volume":"36","author":"Chung","year":"2022","journal-title":"Neurocrit Care"},{"key":"R9-20240806","doi-asserted-by":"crossref","first-page":"3214","DOI":"10.1161\/STROKEAHA.123.044106","article-title":"Comment regarding the 2023 guideline for the management of patients with aneurysmal subarachnoid hemorrhage.","volume":"54","author":"Olson","year":"2023","journal-title":"Stroke"},{"key":"R10-20240806","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1007\/s10143-021-01627-w","article-title":"External ventricular drain management in subarachnoid haemorrhage: A systematic review and meta-analysis.","volume":"45","author":"Palasz","year":"2022","journal-title":"Neurosurg Rev"},{"issue":"Suppl 1","key":"R11-20240806","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1007\/s12028-019-00736-1","article-title":"Common data element for unruptured intracranial aneurysm and subarachnoid hemorrhage: Recommendations from assessments and clinical examination workgroup\/subcommittee.","volume":"30","author":"Damani","year":"2019","journal-title":"Neurocrit Care"},{"key":"R12-20240806","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1007\/s12028-023-01803-4","article-title":"Common data elements for disorders of consciousness: Recommendations from the working group on hospital course, confounders, and medications.","volume":"39","author":"Barra","year":"2023","journal-title":"Neurocrit Care"},{"key":"R13-20240806","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1007\/s12028-022-01581-5","article-title":"Predictive values for time from transducer stopcock closure to accurate intracranial pressure reading.","volume":"38","author":"Earthman","year":"2023","journal-title":"Neurocrit Care"},{"key":"R14-20240806","doi-asserted-by":"crossref","first-page":"322","DOI":"10.1097\/JNN.0000000000000398","article-title":"The impact of head-of-bed positioning and transducer location on cerebral perfusion pressure measurement.","volume":"50","author":"McNett","year":"2018","journal-title":"J Neurosci Nurs"},{"key":"R15-20240806","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1891\/1061-3749.23.3.532","article-title":"Electronic medical record validation: Exploring the reliability of intracranial pressure data abstracted from the electronic medical record-pilot.","volume":"23","author":"Olson","year":"2015","journal-title":"J Nurs Meas"},{"key":"R16-20240806","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/S1474-4422(21)00138-1","article-title":"Intracranial pressure monitoring in patients with acute brain injury in the intensive care unit (SYNAPSE-ICU): An international, prospective observational cohort study.","volume":"20","author":"Robba","year":"2021","journal-title":"Lancet Neurol"},{"key":"R17-20240806","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1007\/s12028-018-0613-x","article-title":"Differentiate the source and site of intracranial pressure measurements using more precise nomenclature.","volume":"30","author":"Olson","year":"2019","journal-title":"Neurocrit Care"},{"key":"R18-20240806","doi-asserted-by":"crossref","first-page":"415","DOI":"10.1891\/1061-3749.26.3.415","article-title":"Inconsistency in reporting variables related to intracranial pressure measurement in scientific literature.","volume":"26","author":"Samudra","year":"2018","journal-title":"J Nurs Meas"},{"key":"R19-20240806","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1097\/JNN.0000000000000622","article-title":"Zero-calibrating external ventricular drains: Exploring practice.","volume":"54","author":"Pratt","year":"2022","journal-title":"J Neurosci Nurs"},{"key":"R20-20240806","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.ccc.2022.08.002","article-title":"Neurotrauma and intracranial pressure management.","volume":"39","author":"Bernard","year":"2023","journal-title":"Crit Care Clin"},{"key":"R21-20240806","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/01.NURSE.0000751336.84200.7a","article-title":"Exploring the accuracy and precision of BP measurements.","volume":"51","author":"Herrera","year":"2021","journal-title":"Nursing"},{"key":"R22-20240806","doi-asserted-by":"crossref","first-page":"e64","DOI":"10.1097\/QAI.0000000000001183","article-title":"Brief report: Flow rate of cerebrospinal fluid through a spinal needle can accurately predict intracranial pressure in cryptococcal meningitis.","volume":"74","author":"Boyles","year":"2017","journal-title":"J Acquir Immune Defic Syndr"},{"key":"R23-20240806","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.jcrc.2013.08.012","article-title":"Predictors of extraventricular drain-associated bacterial ventriculitis.","volume":"29","author":"Williamson","year":"2014","journal-title":"J Crit Care"},{"key":"R24-20240806","doi-asserted-by":"crossref","first-page":"1121","DOI":"10.1007\/s00701-021-04712-7","article-title":"Accuracy of bolt external ventricular drain insertion by neurosurgeons of different experience.","volume":"163","author":"Cabrilo","year":"2021","journal-title":"Acta Neurochir (Wien)"},{"key":"R25-20240806","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.3389\/fphys.2019.01329","article-title":"Blood rheology: Key parameters, impact on blood flow, role in sickle cell disease and effects of exercise.","volume":"10","author":"Nader","year":"2019","journal-title":"Front Physiol"},{"key":"R26-20240806","doi-asserted-by":"crossref","first-page":"e18","DOI":"10.1016\/j.wneu.2019.07.213","article-title":"Discrepancy between internal and external intracranial pressure transducers: Quantification of an old source of error in EVDs?","volume":"133","author":"Darrow","year":"2020","journal-title":"World Neurosurg"},{"key":"R27-20240806","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1016\/j.wneu.2023.06.069","article-title":"Drainage, Irrigation, and Fibrinolytic Therapy (DRIFT) for adult intraventricular hemorrhage associated with primary hypertensive hemorrhages using IRRAflow self-irrigating catheter: A report of three cases and prior historical controls.","volume":"177","author":"Field","year":"2023","journal-title":"World Neurosurg"},{"key":"R28-20240806","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/ANA.0000000000000694","article-title":"A narrative review of the published literature, hospital practices, and policies related to external ventricular drains in the United States: The External Ventricular Drain Publications, Practices, and Policies (EVDPoP) study.","volume":"34","author":"Thamjamrassri","year":"2022","journal-title":"J Neurosurg Anesthesiol"},{"key":"R29-20240806","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1590\/0004-282x20190112","article-title":"Aneurysmal subarachnoid hemorrhage: Current concepts and updates.","volume":"77","author":"Rouanet","year":"2019","journal-title":"Arq Neuropsiquiatr"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001089","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,6]],"date-time":"2024-08-06T22:07:57Z","timestamp":1722982077000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001089"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5]]},"references-count":29,"journal-issue":{"issue":"5","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000001089","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5]]}}}