{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,12]],"date-time":"2026-05-12T04:09:38Z","timestamp":1778558978220,"version":"3.51.4"},"reference-count":46,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","license":[{"start":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T00:00:00Z","timestamp":1716508800000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>Measurement of blood pressure taken from different anatomical sites, are often perceived as interchangeable, despite them representing different parts of the systemic circulation. We aimed to perform a systematic review and meta-analysis on blood pressure differences between central and peripheral arterial cannulation in critically ill patients.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DATA SOURCES:<\/jats:title>\n            <jats:p>We searched MEDLINE, Cochrane Central Register of Controlled Trials, and Embase from inception to December 26, 2023, using Medical Subject Headings (MeSH) terms and keywords.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>STUDY SELECTION:<\/jats:title>\n            <jats:p>Observation study of adult patients in ICUs and operating rooms who underwent simultaneous central (femoral, axillary, or subclavian artery) and peripheral (radial, brachial, or dorsalis pedis artery) arterial catheter placement in ICUs and operating rooms.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DATA EXTRACTION:<\/jats:title>\n            <jats:p>We screened and extracted studies independently and in duplicate. We assessed risk of bias using the revised Quality Assessment for Studies of Diagnostic Accuracy tool.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DATA SYNTHESIS:<\/jats:title>\n            <jats:p>Twenty-four studies that enrolled 1598 patients in total were included. Central pressures (mean arterial pressure [MAP] and systolic blood pressure [SBP]) were found to be significantly higher than their peripheral counterparts, with mean gradients of 3.5 and 8.0\u2009mm Hg, respectively. However, there was no statistically significant difference in central or peripheral diastolic blood pressure (DBP). Subgroup analysis further highlighted a higher MAP gradient during the on-cardiopulmonary bypass stage of cardiac surgery, reperfusion stage of liver transplant, and in nonsurgical critically ill patients. SBP or DBP gradient did not demonstrate any subgroup specific changes.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>SBP and MAP obtained by central arterial cannulation were higher than peripheral arterial cannulation; however, clinical implication of a difference of 8.0\u2009mm Hg in SBP and 3.5\u2009mm Hg in MAP remains unclear. Our current clinical practices preferring peripheral arterial lines need not change.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000001096","type":"journal-article","created":{"date-parts":[[2024,5,24]],"date-time":"2024-05-24T14:05:47Z","timestamp":1716559547000},"page":"e1096","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":7,"title":["Comparison of Central and Peripheral Arterial Blood Pressure Gradients in Critically Ill Patients: A Systematic Review and Meta-Analysis"],"prefix":"10.1097","volume":"6","author":[{"given":"Daisuke","family":"Hasegawa","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, Mount Sinai Beth Israel, New York, NY."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryota","family":"Sato","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Department of Medicine, The Queen\u2019s Medical Center, Honolulu, HI."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Abhijit","family":"Duggal","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Respiratory Institute, Cleveland Clinic, Cleveland, OH."},{"name":"Department of Medicine, Cleveland Clinic Lerner College of Medicine, Cleveland, OH."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mary","family":"Schleicher","sequence":"additional","affiliation":[{"name":"The Cleveland Clinic Floyd D. Loop Alumni Library, Cleveland Clinic, Cleveland, OH."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazuki","family":"Nishida","sequence":"additional","affiliation":[{"name":"Department of Biostatistics, Nagoya University Graduate School of Medicine, Nagoya, Japan."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ashish K.","family":"Khanna","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Section on Critical Care Medicine, Wake Forest University School of Medicine, Winston-Salem, NC."},{"name":"Outcomes Research Consortium, Cleveland, OH."},{"name":"Perioperative Outcomes and Informatics Collaborative, Winston-Salem, NC."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Siddharth","family":"Dugar","sequence":"additional","affiliation":[{"name":"Department of Critical Care Medicine, Respiratory Institute, Cleveland Clinic, Cleveland, OH."},{"name":"Department of Medicine, Cleveland Clinic Lerner College of Medicine, Cleveland, OH."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,5,24]]},"reference":[{"key":"R1-20240806","first-page":"127","article-title":"Indications and complications of arterial catheter use in surgical or medical intensive care units: Analysis of 4932 patients.","volume":"64","author":"Frezza","year":"1998","journal-title":"Am Surg"},{"key":"R2-20240806","doi-asserted-by":"crossref","first-page":"e162","DOI":"10.1093\/cid\/cir257","article-title":"Guidelines for the prevention of intravascular catheter-related infections.","volume":"52","author":"O\u2019Grady","year":"2011","journal-title":"Clin Infect Dis"},{"key":"R3-20240806","doi-asserted-by":"crossref","first-page":"431","DOI":"10.1177\/00033197211052127","article-title":"Retrospective observational single-center study of complications of arterial indwelling catheters for invasive blood pressure in intensive care unit patients.","volume":"73","author":"Baptistella","year":"2022","journal-title":"Angiology"},{"key":"R4-20240806","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1164\/rccm.201003-0410ED","article-title":"Indwelling arterial catheters in the intensive care unit: Necessary and beneficial, or a harmful crutch?","volume":"182","author":"Garland","year":"2010","journal-title":"Am J Respir Crit Care Med"},{"key":"R5-20240806","doi-asserted-by":"crossref","first-page":"R83","DOI":"10.1186\/cc4930","article-title":"Arterial catheter-related infection of 2,949 catheters.","volume":"10","author":"Lorente","year":"2006","journal-title":"Crit Care"},{"key":"R6-20240806","doi-asserted-by":"crossref","first-page":"8825","DOI":"10.1038\/s41598-022-12975-y","article-title":"Agreements between mean arterial pressure from radial and femoral artery measurements in refractory shock patients.","volume":"12","author":"Wisanusattra","year":"2022","journal-title":"Sci Rep"},{"key":"R7-20240806","first-page":"e33095","article-title":"Central versus peripheral invasive arterial blood pressure monitoring in liver transplant surgery.","volume":"14","author":"Kim","year":"2022","journal-title":"Cureus"},{"key":"R8-20240806","doi-asserted-by":"crossref","first-page":"1019752","DOI":"10.3389\/fmed.2022.1019752","article-title":"Arterial site selection for measurement of mean arterial pressure in septic shock patients on high-dose norepinephrine.","volume":"9","author":"Bhaskar","year":"2022","journal-title":"Front Med (Lausanne)"},{"key":"R9-20240806","doi-asserted-by":"crossref","first-page":"302","DOI":"10.4103\/ija.IJA_495_20","article-title":"Correlation between radial and femoral arterial blood pressure during reperfusion in living donor liver transplantation.","volume":"65","author":"Thomas","year":"2021","journal-title":"Indian J Anaesth"},{"key":"R10-20240806","doi-asserted-by":"crossref","first-page":"360","DOI":"10.17085\/apm.21001","article-title":"Ability of dynamic preload indices to predict fluid responsiveness in a high femoral-to-radial arterial pressure gradient: A retrospective study.","volume":"16","author":"Kim","year":"2021","journal-title":"Anesth Pain Med (Seoul)"},{"key":"R11-20240806","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1186\/s40560-021-00585-1","article-title":"Non-invasive detection of a femoral-to-radial arterial pressure gradient in intensive care patients with vasoactive agents.","volume":"9","author":"Jacquet-Lagr\u00e8ze","year":"2021","journal-title":"J Intensive Care"},{"key":"R12-20240806","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1177\/0391398818784791","article-title":"Pressure difference between radial and femoral artery pressure in minimally invasive cardiac surgery using retrograde perfusion.","volume":"41","author":"Nakamura","year":"2018","journal-title":"Int J Artif Organs"},{"key":"R13-20240806","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1053\/j.jvca.2017.02.016","article-title":"Authentication of radial versus femoral arterial pressure waveform-derived cardiac output with transesophageal echocardiography-derived cardiac output measurements in patients undergoing on-pump coronary bypass surgery.","volume":"31","author":"Maddali","year":"2017","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R14-20240806","first-page":"310","article-title":"Peripheral arterial blood pressure versus central arterial blood pressure monitoring in critically ill patients after cardio-pulmonary bypass.","volume":"33","author":"Ahmad","year":"2017","journal-title":"Pak J Med Sci"},{"key":"R15-20240806","first-page":"101","article-title":"Agreement between radial and femoral arterial blood pressure measurements during orthotopic liver transplantation.","volume":"17","author":"Lee","year":"2015","journal-title":"Crit Care Resusc"},{"key":"R16-20240806","doi-asserted-by":"crossref","first-page":"e68890","DOI":"10.1371\/journal.pone.0068890","article-title":"Central-radial artery pressure gradient after cardiopulmonary bypass is associated with cardiac function and may affect therapeutic direction.","volume":"8","author":"Sun","year":"2013","journal-title":"PLoS One"},{"key":"R17-20240806","doi-asserted-by":"crossref","first-page":"e97","DOI":"10.1016\/j.annfar.2013.06.011","article-title":"Study of agreement of aortic, radial and femoral blood pressures during aortic endografting.","volume":"32","author":"Ruiz","year":"2013","journal-title":"Ann Fr Anesth Reanim"},{"key":"R18-20240806","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1097\/SHK.0000000000000064","article-title":"Radial to femoral arterial blood pressure differences in septic shock patients receiving high-dose norepinephrine therapy.","volume":"40","author":"Kim","year":"2013","journal-title":"Shock"},{"key":"R19-20240806","first-page":"818","article-title":"A comparison of continous non-invasive arterial pressure with invasive radial and femoral pressure in patients undergoing cardiac surgery.","volume":"79","author":"Broch","year":"2013","journal-title":"Minerva Anestesiol"},{"key":"R20-20240806","doi-asserted-by":"crossref","first-page":"4220","DOI":"10.1016\/j.transproceed.2009.09.050","article-title":"Comparison of stroke volume variations derived from radial and femoral arterial pressure waveforms during liver transplantation.","volume":"41","author":"Kim","year":"2009","journal-title":"Transplant Proc"},{"key":"R21-20240806","first-page":"34","article-title":"Femoral-radial arterial pressure gradients in critically ill patients.","volume":"11","author":"Galluccio","year":"2009","journal-title":"Crit Care Resusc"},{"key":"R22-20240806","doi-asserted-by":"crossref","first-page":"1326","DOI":"10.1016\/j.transproceed.2007.02.075","article-title":"Comparison of femoral arterial blood pressure with radial arterial blood pressure and noninvasive upper arm blood pressure in the reperfusion period during liver transplantation.","volume":"39","author":"Shin","year":"2007","journal-title":"Transplant Proc"},{"key":"R23-20240806","doi-asserted-by":"crossref","first-page":"R43","DOI":"10.1186\/cc4852","article-title":"Peripheral arterial blood pressure monitoring adequately tracks central arterial blood pressure in critically ill patients: An observational study.","volume":"10","author":"Mignini","year":"2006","journal-title":"Crit Care"},{"key":"R24-20240806","doi-asserted-by":"crossref","first-page":"766","DOI":"10.1111\/j.1365-2044.2005.04257.x","article-title":"Radial to femoral arterial blood pressure differences during liver transplantation.","volume":"60","author":"Arnal","year":"2005","journal-title":"Anaesthesia"},{"key":"R25-20240806","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1053\/cr.2000.5855","article-title":"Femoral artery pressures are more reliable than radial artery pressures on initiation of cardiopulmonary bypass.","volume":"14","author":"Chauhan","year":"2000","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R26-20240806","doi-asserted-by":"crossref","first-page":"2647","DOI":"10.1016\/S0041-1345(00)01821-2","article-title":"Is femoral and radial artery pressure different during reperfusion in liver transplantation?","volume":"32","author":"Acosta","year":"2000","journal-title":"Transplant Proc"},{"key":"R27-20240806","first-page":"252","article-title":"Radial artery diameter decreases with increased femoral to radial arterial pressure gradient during cardiopulmonary bypass.","volume":"85","author":"Baba","year":"1997","journal-title":"Anesth Analg"},{"key":"R28-20240806","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1177\/0310057X8901700311","article-title":"A comparison of brachial, femoral, and aortic intra-arterial pressures before and after cardiopulmonary bypass.","volume":"17","author":"Gravlee","year":"1989","journal-title":"Anaesth Intensive Care"},{"key":"R29-20240806","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/S0022-5223(19)36295-6","article-title":"Inaccuracy of radial artery pressure measurement after cardiac operations.","volume":"94","author":"Mohr","year":"1987","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R30-20240806","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.1016\/j.jclinepi.2009.06.006","article-title":"The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration.","volume":"62","author":"Liberati","year":"2009","journal-title":"J Clin Epidemiol"},{"key":"R31-20240806","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/2046-4053-4-1","article-title":"Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement.","volume":"4","author":"Moher","year":"2015","journal-title":"Syst Rev"},{"key":"R32-20240806","doi-asserted-by":"crossref","first-page":"2008","DOI":"10.1001\/jama.283.15.2008","article-title":"Meta-analysis of observational studies in epidemiology: A proposal for reporting. Meta-analysis Of Observational Studies in Epidemiology (MOOSE) group.","volume":"283","author":"Stroup","year":"2000","journal-title":"JAMA"},{"key":"R33-20240806","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/j.jclinepi.2015.03.017","article-title":"Small studies are more heterogeneous than large ones: A meta-meta-analysis.","volume":"68","author":"IntHout","year":"2015","journal-title":"J Clin Epidemiol"},{"key":"R35-20240806","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1016\/j.jclinepi.2005.06.006","article-title":"Imputing missing standard deviations in meta-analyses can provide accurate results.","volume":"59","author":"Furukawa","year":"2006","journal-title":"J Clin Epidemiol"},{"key":"R37-20240806","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies.","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"R38-20240806","doi-asserted-by":"crossref","first-page":"448","DOI":"10.3949\/ccjm.55.5.448","article-title":"Radial artery pressures compared with subclavian artery pressure during coronary artery surgery.","volume":"55","author":"Bazaral","year":"1988","journal-title":"Cleve Clin J Med"},{"key":"R39-20240806","doi-asserted-by":"crossref","first-page":"1646","DOI":"10.1097\/00003246-199810000-00014","article-title":"Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients.","volume":"26","author":"Dorman","year":"1998","journal-title":"Crit Care Med"},{"key":"R40-20240806","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1034\/j.1399-6576.2002.460208.x","article-title":"Accuracy of radial arterial pressure measurement during surgery under controlled hypotension.","volume":"46","author":"Yazigi","year":"2002","journal-title":"Acta Anaesthesiol Scand"},{"key":"R41-20240806","doi-asserted-by":"crossref","first-page":"95","DOI":"10.1055\/s-0038-1624062","article-title":"Continuous cardiac output measurement during off-pump coronary artery bypass grafting: Radial arterial pulse wave versus femoral arterial pulse wave.","volume":"1","author":"Kanchi","year":"2017","journal-title":"J Cardiac Crit Care TSS"},{"key":"R42-20240806","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1161\/01.RES.3.6.623","article-title":"Comparison of simultaneously recorded central and peripheral arterial pressure pulses during rest, exercise and tilted position in man.","volume":"3","author":"Kroeker","year":"1955","journal-title":"Circ Res"},{"key":"R43-20240806","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1161\/hy1001.096106","article-title":"Prospective evaluation of a method for estimating ascending aortic pressure from the radial artery pressure waveform.","volume":"38","author":"Pauca","year":"2001","journal-title":"Hypertension"},{"key":"R44-20240806","doi-asserted-by":"crossref","first-page":"410","DOI":"10.1007\/s00380-007-0998-5","article-title":"Relationship between blood pressure obtained from the upper arm with a cuff-type sphygmomanometer and central blood pressure measured with a catheter-tipped micromanometer.","volume":"22","author":"Ohte","year":"2007","journal-title":"Heart Vessels"},{"key":"R45-20240806","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1016\/j.xjon.2021.07.031","article-title":"Radial-to-femoral pressure gradient quantification in cardiac surgery.","volume":"8","author":"Bouchard-Dech\u00eane","year":"2021","journal-title":"JTCVS Open"},{"key":"R46-20240806","first-page":"641","article-title":"Role of total arterial compliance and peripheral resistance in the determination of systolic and diastolic aortic pressure.","volume":"47","author":"Stergiopulos","year":"1999","journal-title":"Pathol Biol (Paris)"},{"key":"R47-20240806","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/j.bpa.2014.08.002","article-title":"Arterial waveform analysis.","volume":"28","author":"Esper","year":"2014","journal-title":"Best Pract Res Clin Anaesthesiol"},{"key":"R48-20240806","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1378\/chest.14-1212","article-title":"Arterial lines in the ICU: A call for rigorous controlled trials.","volume":"146","author":"Garland","year":"2014","journal-title":"Chest"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001096","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,8,6]],"date-time":"2024-08-06T22:10:50Z","timestamp":1722982250000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001096"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,5,24]]},"references-count":46,"journal-issue":{"issue":"6","published-online":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000001096","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,5,24]]}}}