{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,29]],"date-time":"2026-07-29T20:45:49Z","timestamp":1785357949577,"version":"3.55.0"},"reference-count":7,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>High velocity therapy (HVT), a form of high-flow oxygen therapy, utilizing a small-bore nasal cannula has been widely used in acute care settings. A new dual-prong (newDP) cannula made using more comfortable material and a single-prong (SP) cannula were evaluated to compare comfort and functionality as measured by relief of dyspnea of patients with chronic obstructive pulmonary disease (COPD) receiving HVT therapy.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Randomized crossover evaluation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Outpatient and in patient critical care setting.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>PATIENTS:<\/jats:title>\n            <jats:p>Patients with hypercapnic COPD presenting with dyspnea above baseline.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>HVT therapy was provided using an existing HVT dual-prong nasal cannula (traditional) to determine the most efficacious flow rate. Patients were then randomized to receive either the newDP cannula, or the SP cannula, and retitrated for optimal flow rate. During each session of therapy, Rated Perceived Dyspnea (RPD) scores, vital signs, transcutaneous carbon dioxide partial pressure (P<jats:sub>TC<\/jats:sub>\n                                 <jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub>) levels, and clinician\/ patient perceptions were documented.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Of 31 enrolled, 26 patients completed the trial. The median flow rate that relieved dyspnea for the traditional, newDP, and SP cannulas were 25\u2009L\/min (20\u201330\u2009L\/min), 25\u2009L\/min (19.1\u201330\u2009L\/min), and 15\u2009L\/min (13\u201317\u2009L\/min), respectively. The change in RPD from baseline for traditional, newDP, and SP were \u20131 (\u20131 to 0), \u20131 (\u20132 to \u20131), and \u20131 (\u20132 to \u20131). Change in RPD from baseline for newDP and SP compared with the traditional cannula was significantly different (<jats:italic toggle=\"yes\">p<\/jats:italic> = 0.044 and <jats:italic toggle=\"yes\">p<\/jats:italic> = 0.01, respectively). Changes in vital signs and P<jats:sub>TC<\/jats:sub>\n                                 <jats:sc>co<\/jats:sc>\n                                 <jats:sub>2<\/jats:sub> were similar between the three cannula types compared with baseline. The SP cannula provided comparable therapeutic efficacy at significantly lower flow rates (traditional vs. SP; <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.0001 and newDP vs. SP; <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.0001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>The new cannula designs provided comparable relief of dyspnea. The single-prong cannula provided comparable efficacy at significantly lower flow rates (traditional vs. SP; <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.0001 and newDP vs. SP; <jats:italic toggle=\"yes\">p<\/jats:italic> &lt; 0.0001). The use of a single-prong cannula with HVT warrants further study.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cce.0000000000001209","type":"journal-article","created":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T17:00:34Z","timestamp":1739379634000},"page":"e1209","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Effect of Single-Prong Cannula Design With High Velocity Therapy: Comparable Efficacy at Lower Gas Flow Rates"],"prefix":"10.1097","volume":"7","author":[{"given":"Charles","family":"Atwood","sequence":"first","affiliation":[{"name":"Pulmonary and Sleep Medicine, VA Pittsburgh Healthcare System, Pittsburgh, PA."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jigme","family":"Sethi","sequence":"additional","affiliation":[{"name":"University of Tennessee Health Science Center, Chattanooga, TN."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amy","family":"Bergeski","sequence":"additional","affiliation":[{"name":"Vapotherm, Exeter, NH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"George C.","family":"Dungan","sequence":"additional","affiliation":[{"name":"Vapotherm, Exeter, NH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonithas I.","family":"Volakis","sequence":"additional","affiliation":[{"name":"Vapotherm, Exeter, NH."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3177-8934","authenticated-orcid":false,"given":"Jessica S.","family":"Whittle","sequence":"additional","affiliation":[{"name":"Vapotherm, Exeter, NH."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,2,12]]},"reference":[{"key":"R1-20250212","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.annemergmed.2017.12.006","article-title":"High-velocity nasal insufflation in the treatment of respiratory failure: A randomized clinical trial.","volume":"72","author":"Doshi","year":"2018","journal-title":"Ann Emerg Med"},{"key":"R2-20250212","doi-asserted-by":"crossref","first-page":"1017965","DOI":"10.3389\/fmed.2022.1017965","article-title":"Recent advances in the use of high flow nasal oxygen therapies.","volume":"9","author":"Wyatt","year":"2022","journal-title":"Front Med"},{"key":"R3-20250212","doi-asserted-by":"crossref","first-page":"1400","DOI":"10.1016\/j.rmed.2009.04.007","article-title":"Research in high flow therapy: Mechanisms of action.","volume":"103","author":"Dysart","year":"2009","journal-title":"Respir Med"},{"key":"R4-20250212","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1186\/s13054-023-04441-6","article-title":"Effects of an asymmetrical high flow nasal cannula interface in hypoxemic patients.","volume":"27","author":"Slobod","year":"2023","journal-title":"Crit Care"},{"key":"R5-20250212","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1152\/japplphysiol.00692.2022","article-title":"Asymmetrical nasal high flow ventilation improves clearance of CO2 from the anatomical dead space and increases positive airway pressure.","volume":"134","author":"Tatkov","year":"2023","journal-title":"J. Appl Physiol"},{"key":"R6-20250212","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1186\/s12890-023-02820-x","article-title":"Asymmetrical high-flow nasal cannula performs similarly to standard interface in patients with acute hypoxemic post-extubation respiratory failure: A pilot study.","volume":"24","author":"Boscolo","year":"2024","journal-title":"BMC Pulm Med"},{"key":"R7-20250212","doi-asserted-by":"crossref","first-page":"F321","DOI":"10.1136\/archdischild-2018-315621","article-title":"3D airway model to assess airway dead space.","volume":"104","author":"Nieves","year":"2019","journal-title":"Arch Dis Child Fetal Neonatal Ed"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001209","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,12]],"date-time":"2025-02-12T17:00:36Z","timestamp":1739379636000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001209"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":7,"journal-issue":{"issue":"2","published-online":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000001209","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,2]]}}}