{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,7]],"date-time":"2026-09-07T17:18:19Z","timestamp":1788801499555,"version":"build-2803163510"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","license":[{"start":{"date-parts":[[2026,3,1]],"date-time":"2026-03-01T00:00:00Z","timestamp":1772323200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:sec>\n                    <jats:title>IMPORTANCE:<\/jats:title>\n                    <jats:p>Venous congestion contributes to multiple organ dysfunction and mortality in critically ill patients. The venous excess ultrasound (VExUS) and lung ultrasound scores have been shown to reflect cardiac filling pressures, but their ability to track hemodynamic changes during decongestion in critically ill patients remains unclear.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>To determine the correlation of lung ultrasound and VExUS scores with intracardiac filling pressures before and after decongestion in critically ill patients with acute decompensated heart failure.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>DESIGN, SETTING, AND PARTICIPANTS:<\/jats:title>\n                    <jats:p>We conducted a prospective single-center observational pilot study of adults admitted to the cardiac intensive care and who underwent pulmonary artery catheter placement for hemodynamic-guided decongestion. We performed paired measurements of VExUS grade, simplified lung ultrasound (sLUS) scores, and calculated the renal venous stasis index (RVSI) before and after decongestion and assessed for changes and correlation with right atrial pressure (RAP) and pulmonary artery occlusion pressure (PAOP).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n                    <jats:p>\n                      Twenty patients underwent 40-paired assessments. After decongestion, a significant reduction in RAP (\u20139.2\u2009mm Hg; 95% CI, \u201312.4 to \u20135.9\u2009mm Hg;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2264 0.0001) and PAOP (\u201312.8\u2009mm Hg; 95% CI, \u201316.6 to \u20139.1\u2009mm Hg;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2264 0.0001) mirrored reductions in VExUS grades (\u20131.3; 95% CI, \u20131.8 to \u20130.7;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.0002), portal vein pulsatility fraction (\u201319.9%; 95% CI, \u201334.1 to \u20135.6;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.0075), RVSI (\u20130.19; 95% CI, \u20130.38 to 0;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.04), and sLUS (\u201311 points; 95% CI, \u201314.2 to \u20138.5;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2264 0.0001). VExUS grades and portal vein pulsatility fraction correlated with RAP both before (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.02 and\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      \u2264 0.003) and after (\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.01 and\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.001) decongestion, but neither correlated with PAOP. sLUS correlated with PAOP at baseline (\u03c1 = 0.82;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      &lt; 0.001) and following decongestion (\u03c1 = 0.59;\n                      <jats:italic toggle=\"yes\">p<\/jats:italic>\n                      = 0.05), while showing no significant correlation with RAP pre-decongestion.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS AND RELEVANCE:<\/jats:title>\n                    <jats:p>In critically ill patients with acute decompensated heart failure, we observed changes in VExUS and sLUS scores with decongestion which mirrored changes in intracardiac pressures. The portal vein pulsatility fraction had the higher reproducibility of the VExUS subcomponents. These findings support the role of VExUS and sLUS in hemodynamic monitoring of decongestion in critically ill patients with acute decompensated heart failure.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/cce.0000000000001385","type":"journal-article","created":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T18:00:39Z","timestamp":1773165639000},"page":"e1385","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Lung and Venous Excess Ultrasound Correlation With Intracardiac Pressures Before and After Decongestion in Critically Ill Patients With Acute Decompensated Heart Failure"],"prefix":"10.1097","volume":"8","author":[{"given":"Jose Victor","family":"Jimenez","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, Yale New Haven Hospital, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sukrit","family":"Narula","sequence":"additional","affiliation":[{"name":"Section of Cardiovascular Medicine, Yale School of Medicine, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Santiago","family":"Callegari","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Yale New Haven Hospital, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eduardo R.","family":"Argaiz","sequence":"additional","affiliation":[{"name":"Departamento de Nefrolog\u00eda y Metabolismo Mineral, Instituto Nacional de Ciencias M\u00e9dicas y Nutrici\u00f3n Salvador Zubir\u00e1n, Mexico City, Mexico."},{"name":"Tecnol\u00f3gico de Monterrey, Escuela de Medicina y Ciencias de La Salud, Mexico City, Mexico."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Edward W.","family":"Chen","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Yale New Haven Hospital, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Lapetina Arroyo","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Yale New Haven Hospital, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jennifer","family":"Miao","sequence":"additional","affiliation":[{"name":"Section of Cardiovascular Medicine, Yale School of Medicine, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zachary","family":"Feldman","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Yale New Haven Hospital, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tariq","family":"Ali","sequence":"additional","affiliation":[{"name":"Section of Cardiovascular Medicine, Yale School of Medicine, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joseph H.","family":"Donroe","sequence":"additional","affiliation":[{"name":"Department of Medicine, Yale School of Medicine, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P. Elliott","family":"Miller","sequence":"additional","affiliation":[{"name":"Section of Cardiovascular Medicine, Yale School of Medicine, New Haven, CT."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,3,10]]},"reference":[{"key":"R1-20260310","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1186\/s13054-020-2770-5","article-title":"Elevated central venous pressure is associated with increased mortality and acute kidney injury in critically ill patients: A meta-analysis.","volume":"24","author":"Chen","year":"2020","journal-title":"Crit Care"},{"key":"R2-20260310","doi-asserted-by":"crossref","first-page":"1862","DOI":"10.1097\/CCM.0000000000004617","article-title":"Fluid overload and mortality in adult critical care patients\u2014a systematic review and meta-analysis of observational studies.","volume":"48","author":"Messmer","year":"2020","journal-title":"Crit Care Med"},{"key":"R3-20260310","doi-asserted-by":"crossref","first-page":"17757","DOI":"10.1038\/s41598-018-36189-3","article-title":"Selective abdominal venous congestion induces adverse renal and hepatic morphological and functional alterations despite a preserved cardiac function.","volume":"8","author":"Cops","year":"2018","journal-title":"Sci Rep"},{"key":"R4-20260310","doi-asserted-by":"crossref","first-page":"67","DOI":"10.15441\/ceem.14.040","article-title":"Assessing volume status and fluid responsiveness in the emergency department.","volume":"1","author":"Mackenzie","year":"2014","journal-title":"Clin Exp Emerg Med"},{"key":"R5-20260310","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.jchf.2016.03.004","article-title":"Treating hemodynamic congestion is the key to prevent heart failure hospitalizations.","volume":"4","author":"Klein","year":"2016","journal-title":"JACC Heart Fail"},{"key":"R6-20260310","doi-asserted-by":"crossref","first-page":"1667","DOI":"10.1016\/j.chest.2024.12.026","article-title":"Demystifying volume status: An ultrasound-guided physiologic framework.","volume":"167","author":"Kan","year":"2025","journal-title":"Chest"},{"key":"R7-20260310","doi-asserted-by":"crossref","first-page":"903","DOI":"10.1016\/j.jchf.2023.04.007","article-title":"Pulmonary artery catheter use and mortality in the cardiac intensive care unit.","volume":"11","author":"Kadosh","year":"2023","journal-title":"JACC Heart Fail"},{"key":"R8-20260310","doi-asserted-by":"crossref","first-page":"102609","DOI":"10.1016\/j.jchf.2025.102609","article-title":"Pulmonary artery catheter timing and outcomes for patients with cardiogenic shock.","volume":"13","author":"Safiriyu","year":"2025","journal-title":"JACC Heart Fail"},{"key":"R9-20260310","doi-asserted-by":"crossref","first-page":"908","DOI":"10.1001\/jamacardio.2017.1670","article-title":"National trends in use and outcomes of pulmonary artery catheters among Medicare beneficiaries, 1999-2013.","volume":"2","author":"Ikuta","year":"2017","journal-title":"JAMA Cardiol"},{"key":"R10-20260310","doi-asserted-by":"crossref","first-page":"107415","DOI":"10.1016\/j.rmed.2023.107415","article-title":"Lung ultrasonography derived B-line scores as predictors of left ventricular end-diastolic pressure and pulmonary artery wedge pressure.","volume":"219","author":"Garcia","year":"2023","journal-title":"Respir Med"},{"key":"R11-20260310","doi-asserted-by":"crossref","first-page":"1605","DOI":"10.1002\/ejhf.1604","article-title":"Lung ultrasound-guided treatment in ambulatory patients with heart failure: A randomized controlled clinical trial (LUS-HF study).","volume":"21","author":"Rivas-Lasarte","year":"2019","journal-title":"Eur J Heart Fail"},{"key":"R12-20260310","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.ahj.2020.06.003","article-title":"A randomized controlled trial of lung ultrasound-guided therapy in heart failure (CLUSTER-HF study).","volume":"227","author":"Araiza-Garaygordobil","year":"2020","journal-title":"Am Heart J"},{"key":"R13-20260310","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1016\/j.kint.2021.07.024","article-title":"A randomized multicenter trial on a lung ultrasound-guided treatment strategy in patients on chronic hemodialysis with high cardiovascular risk.","volume":"100","author":"Zoccali","year":"2021","journal-title":"Kidney Int"},{"key":"R14-20260310","doi-asserted-by":"crossref","first-page":"252","DOI":"10.1053\/j.ackd.2021.03.004","article-title":"VExUS Nexus: Bedside assessment of venous congestion.","volume":"28","author":"Argaiz","year":"2021","journal-title":"Adv Chronic Kidney Dis"},{"key":"R15-20260310","doi-asserted-by":"crossref","first-page":"590","DOI":"10.1016\/j.chest.2023.09.029","article-title":"Prospective evaluation of venous excess ultrasound for estimation of venous congestion.","volume":"165","author":"Longino","year":"2024","journal-title":"Chest"},{"key":"R16-20260310","doi-asserted-by":"crossref","first-page":"e009961","DOI":"10.1161\/JAHA.118.009961","article-title":"Alterations in portal vein flow and intrarenal venous flow are associated with acute kidney injury after cardiac surgery: A prospective observational cohort study.","volume":"7","author":"Beaubien-Souligny","year":"2018","journal-title":"J Am Heart Assoc"},{"key":"R17-20260310","first-page":"570","article-title":"Portal vein Doppler tracks volume status in patients with severe tricuspid regurgitation: A proof-of-concept study.","volume":"13","author":"Alday-Ram\u00edrez","year":"2024","journal-title":"Eur Heart J Acute Cardiovasc Care"},{"key":"R18-20260310","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1186\/s13054-015-0756-5","article-title":"Simplified lung ultrasound protocol shows excellent prediction of extravascular lung water in ventilated intensive care patients.","volume":"19","author":"Enghard","year":"2015","journal-title":"Crit Care"},{"key":"R19-20260310","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/j.jchf.2019.09.012","article-title":"Diuretic strategies for loop diuretic resistance in acute heart failure: The 3T trial.","volume":"8","author":"Cox","year":"2020","journal-title":"JACC Heart Fail"},{"key":"R20-20260310","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.echo.2018.06.004","article-title":"Guidelines for performing a comprehensive transthoracic echocardiographic examination in adults: Recommendations from the American Society of Echocardiography.","volume":"32","author":"Mitchell","year":"2019","journal-title":"J Am Soc Echocardiogr"},{"key":"R21-20260310","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/s13089-020-00163-w","article-title":"Quantifying systemic congestion with point-of-care ultrasound: Development of the venous excess ultrasound grading system.","volume":"12","author":"Beaubien-Souligny","year":"2020","journal-title":"Ultrasound J"},{"key":"R22-20260310","doi-asserted-by":"crossref","first-page":"e013584","DOI":"10.1161\/JAHA.119.013584","article-title":"Doppler-derived renal venous stasis index in the prognosis of right heart failure.","volume":"8","author":"Husain-Syed","year":"2019","journal-title":"J Am Heart Assoc"},{"key":"R23-20260310","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1007\/s00134-025-07932-y","article-title":"ESICM-ESPNIC international expert consensus on quantitative lung ultrasound in intensive care.","volume":"51","author":"Mongodi","year":"2025","journal-title":"Intensive Care Med"},{"key":"R24-20260310","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1097\/00000542-200310000-00036","article-title":"Practice guidelines for pulmonary artery catheterization: An updated report by the American Society of Anesthesiologists Task Force on Pulmonary Artery Catheterization.","volume":"99","year":"2003","journal-title":"Anesthesiology"},{"key":"R25-20260310","doi-asserted-by":"crossref","first-page":"1185","DOI":"10.1056\/NEJMoa2203094","article-title":"Acetazolamide in acute decompensated heart failure with volume overload.","volume":"387","author":"Mullens","year":"2022","journal-title":"N Engl J Med"},{"key":"R26-20260310","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1186\/s13054-020-03330-6","article-title":"The use of venous Doppler to predict adverse kidney events in a general ICU cohort.","volume":"24","author":"Spiegel","year":"2020","journal-title":"Crit Care"},{"key":"R27-20260310","first-page":"413","article-title":"Venous excess ultrasound score and acute kidney injury in patients with acute coronary syndrome.","volume":"12","author":"Viana-Rojas","year":"2023","journal-title":"Eur Heart J Acute Cardiovasc Care"},{"key":"R28-20260310","doi-asserted-by":"crossref","first-page":"1780","DOI":"10.1053\/j.jvca.2017.11.030","article-title":"The association between pulsatile portal flow and acute kidney injury after cardiac surgery: A retrospective cohort study.","volume":"32","author":"Beaubien-Souligny","year":"2018","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R29-20260310","doi-asserted-by":"crossref","first-page":"155097","DOI":"10.1016\/j.jcrc.2025.155097","article-title":"The association between venous excess ultrasound grading system (VExUS) and major adverse kidney events after 30 days in critically ill patients: A prospective cohort study.","volume":"88","author":"Klompmaker","year":"2025","journal-title":"J Crit Care"},{"key":"R30-20260310","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1016\/j.ekir.2023.12.018","article-title":"Prospective study of ultrasound markers of organ congestion in critically ill patients with acute kidney injury.","volume":"9","author":"Beaubien-Souligny","year":"2024","journal-title":"Kidney Int Rep"},{"key":"R31-20260310","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1186\/s13089-024-00397-y","article-title":"Correlation between right atrial pressure measured via right heart catheterization and venous excess ultrasound, inferior vena cava diameter, and ultrasound-measured jugular venous pressure: A prospective observational study.","volume":"16","author":"Klangthamneam","year":"2024","journal-title":"Ultrasound J"},{"key":"R32-20260310","first-page":"rs.3.rs-4185584","article-title":"Venous excess ultrasonography (VExUS) captures dynamic changes in volume status surrounding hemodialysis: A multicenter prospective observational study.","author":"Leyba","year":"2024","journal-title":"Res Sq"},{"key":"R33-20260310","first-page":"375","article-title":"Portal vein Doppler is a sensitive marker for evaluating venous congestion in end-stage kidney disease.","volume":"14","author":"Tonelli","year":"2024","journal-title":"Cardiorenal Med"},{"key":"R34-20260310","doi-asserted-by":"crossref","first-page":"23","DOI":"10.1186\/s13089-024-00370-9","article-title":"Utility of the venous excess ultrasound (VEXUS) score to track dynamic change in volume status in patients undergoing fluid removal during haemodialysis\u2014the ACUVEX study.","volume":"16","author":"Wong","year":"2024","journal-title":"Ultrasound J"},{"key":"R35-20260310","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1186\/s13054-024-04834-1","article-title":"Coexistence of a fluid responsive state and venous congestion signals in critically ill patients: A multicenter observational proof-of-concept study.","volume":"28","author":"Mu\u00f1oz","year":"2024","journal-title":"Crit Care"},{"key":"R36-20260310","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.1016\/j.echo.2025.08.011","article-title":"Modified VExUS: A dynamic tool to predict mortality in acute decompensated heart failure.","volume":"38","author":"Saadi","year":"2025","journal-title":"J Am Soc Echocardiogr"},{"key":"R37-20260310","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1186\/s13054-022-04180-0","article-title":"Doppler study of portal vein and renal venous velocity predict the appropriate fluid response to diuretic in ICU: A prospective observational echocardiographic evaluation.","volume":"26","author":"Guinot","year":"2022","journal-title":"Crit Care"},{"key":"R38-20260310","first-page":"24","article-title":"High VExUS grades are linked to cardiac function in general intensive care unit patients.","volume":"14","author":"Andrei","year":"2025","journal-title":"Eur Heart J Acute Cardiovasc Care"},{"key":"R39-20260310","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1093\/ckj\/sfab213","article-title":"Evaluation of rapid changes in haemodynamic status by point-of-care ultrasound: A useful tool in cardionephrology.","volume":"15","author":"Argaiz","year":"2022","journal-title":"Clin Kidney J"},{"key":"R40-20260310","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1186\/s13054-023-04524-4","article-title":"Prevalence of systemic venous congestion assessed by venous excess ultrasound grading system (VExUS) and association with acute kidney injury in a general ICU cohort: A prospective multicentric study.","volume":"27","author":"Andrei","year":"2023","journal-title":"Crit Care"},{"key":"R41-20260310","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1186\/s13054-024-04961-9","article-title":"Reliability and reproducibility of the venous excess ultrasound (VExUS) score, a multi-site prospective study: Validating a novel ultrasound technique for comprehensive assessment of venous congestion.","volume":"28","author":"Longino","year":"2024","journal-title":"Crit Care"}],"container-title":["Critical Care Explorations"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001385","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,3,10]],"date-time":"2026-03-10T18:00:44Z","timestamp":1773165644000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCE.0000000000001385"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,3]]},"references-count":41,"journal-issue":{"issue":"3","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/cce.0000000000001385","relation":{},"ISSN":["2639-8028"],"issn-type":[{"value":"2639-8028","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,3]]}}}