{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T07:38:59Z","timestamp":1792827539662,"version":"4.5.0"},"reference-count":56,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,4]]},"abstract":"<jats:sec>\n            <jats:title>Objective:<\/jats:title>\n            <jats:p>We performed a systematic review and meta-analysis to examine the accuracy of bedside ultrasound for confirmation of central venous catheter position and exclusion of pneumothorax compared with chest radiography.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Data Sources:<\/jats:title>\n            <jats:p>PubMed, Embase, Cochrane Central Register of Controlled Trials, reference lists, conference proceedings and ClinicalTrials.gov.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Study Selection:<\/jats:title>\n            <jats:p>Articles and abstracts describing the diagnostic accuracy of bedside ultrasound compared with chest radiography for confirmation of central venous catheters in sufficient detail to reconstruct 2\u2009\u00d7\u20092 contingency tables were reviewed. Primary outcomes included the accuracy of confirming catheter positioning and detecting a pneumothorax. Secondary outcomes included feasibility, interrater reliability, and efficiency to complete bedside ultrasound confirmation of central venous catheter position.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Data Extraction:<\/jats:title>\n            <jats:p>Investigators abstracted study details including research design and sonographic imaging technique to detect catheter malposition and procedure-related pneumothorax. Diagnostic accuracy measures included pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Data Synthesis:<\/jats:title>\n            <jats:p>Fifteen studies with 1,553 central venous catheter placements were identified with a pooled sensitivity and specificity of catheter malposition by ultrasound of 0.82 (0.77\u20130.86) and 0.98 (0.97\u20130.99), respectively. The pooled positive and negative likelihood ratios of catheter malposition by ultrasound were 31.12 (14.72\u201365.78) and 0.25 (0.13\u20130.47). The sensitivity and specificity of ultrasound for pneumothorax detection was nearly 100% in the participating studies. Bedside ultrasound reduced mean central venous catheter confirmation time by 58.3 minutes. Risk of bias and clinical heterogeneity in the studies were high.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>Bedside ultrasound is faster than radiography at identifying pneumothorax after central venous catheter insertion. When a central venous catheter malposition exists, bedside ultrasound will identify four out of every five earlier than chest radiography.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ccm.0000000000002188","type":"journal-article","created":{"date-parts":[[2016,12,6]],"date-time":"2016-12-06T14:54:06Z","timestamp":1481036046000},"page":"715-724","source":"Crossref","is-referenced-by-count":97,"title":["Diagnostic Accuracy of Central Venous Catheter Confirmation by Bedside Ultrasound Versus Chest Radiography in Critically Ill Patients: A Systematic Review and Meta-Analysis"],"prefix":"10.1097","volume":"45","author":[{"given":"Enyo A.","family":"Ablordeppey","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne M.","family":"Drewry","sequence":"additional","affiliation":[{"name":"Department of Anesthesiology, Washington University School of Medicine, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander B.","family":"Beyer","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, University of Michigan School of Medicine, Ann Arbor, MI."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Daniel L.","family":"Theodoro","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Washington University School of Medicine, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan A.","family":"Fowler","sequence":"additional","affiliation":[{"name":"Bernard Becker Medical Library, Washington University School of Medicine, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Brian M.","family":"Fuller","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher R.","family":"Carpenter","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Washington University School of Medicine, St. Louis, MO."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230728","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1056\/NEJMra011883","article-title":"Preventing complications of central venous catheterization.","volume":"348","author":"McGee","year":"2003","journal-title":"N Engl J Med"},{"key":"R2-20230728","doi-asserted-by":"crossref","first-page":"2065","DOI":"10.7863\/ultra.15.01027","article-title":"Central venous catheterization: Are we using ultrasound guidance?","volume":"34","author":"Adhikari","year":"2015","journal-title":"J Ultrasound Med"},{"key":"R3-20230728","doi-asserted-by":"crossref","first-page":"554","DOI":"10.1097\/CCM.0b013e3182a66a2a","article-title":"Rates and timing of central venous cannulation among patients with sepsis and respiratory arrest admitted by the emergency department.","volume":"42","author":"Theodoro","year":"2014","journal-title":"Crit Care Med"},{"key":"R4-20230728","doi-asserted-by":"crossref","first-page":"1450","DOI":"10.1097\/CCM.0b013e31827caa89","article-title":"Utilization patterns and outcomes associated with central venous catheter in septic shock: A population-based study.","volume":"41","author":"Walkey","year":"2013","journal-title":"Crit Care Med"},{"key":"R5-20230728","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1001\/jama.286.6.700","article-title":"Complications of femoral and subclavian venous catheterization in critically ill patients: A randomized controlled trial.","volume":"286","author":"Merrer","year":"2001","journal-title":"JAMA"},{"key":"R6-20230728","doi-asserted-by":"crossref","first-page":"S178","DOI":"10.1097\/01.CCM.0000260629.86351.A5","article-title":"Ultrasound imaging in vascular access.","volume":"35","author":"Maecken","year":"2007","journal-title":"Crit Care Med"},{"key":"R7-20230728","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1007\/s00134-007-0560-z","article-title":"Mechanical complications and malpositions of central venous cannulations by experienced operators. A prospective study of 1794 catheterizations in critically ill patients.","volume":"33","author":"Schummer","year":"2007","journal-title":"Intensive Care Med"},{"key":"R8-20230728","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1097\/00003246-200202000-00031","article-title":"Complications of central venous catheters: Internal jugular versus subclavian access\u2013a systematic review.","volume":"30","author":"Ruesch","year":"2002","journal-title":"Crit Care Med"},{"key":"R9-20230728","doi-asserted-by":"crossref","first-page":"1055","DOI":"10.1111\/j.1553-2712.2010.00886.x","article-title":"Risk factors for acute adverse events during ultrasound-guided central venous cannulation in the emergency department.","volume":"17","author":"Theodoro","year":"2010","journal-title":"Acad Emerg Med"},{"key":"R10-20230728","doi-asserted-by":"crossref","first-page":"2053","DOI":"10.1097\/00003246-199612000-00020","article-title":"Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature.","volume":"24","author":"Randolph","year":"1996","journal-title":"Crit Care Med"},{"key":"R11-20230728","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1016\/j.crad.2012.10.013","article-title":"Imaging and management of complications of central venous catheters.","volume":"68","author":"Nayeemuddin","year":"2013","journal-title":"Clin Radiol"},{"key":"R12-20230728","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1097\/00003246-199909000-00019","article-title":"Cannulation of the internal jugular vein: Is postprocedural chest radiography always necessary?","volume":"27","author":"Gladwin","year":"1999","journal-title":"Crit Care Med"},{"key":"R13-20230728","doi-asserted-by":"crossref","first-page":"1513","DOI":"10.1097\/00003246-199211000-00006","article-title":"Value of postprocedural chest radiographs in the adult intensive care unit.","volume":"20","author":"Gray","year":"1992","journal-title":"Crit Care Med"},{"key":"R14-20230728","first-page":"3445","article-title":"[A new route for venous injection or puncture: The subclavicular route, subclavian vein, brachiocephalic trunk].","volume":"28","author":"Aubaniac","year":"1952","journal-title":"Sem Hop"},{"key":"R15-20230728","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1111\/j.0001-5172.2004.00400.x","article-title":"Routine X-ray control of upper central venous lines: Is it necessary?","volume":"48","author":"Molgaard","year":"2004","journal-title":"Acta Anaesthesiol Scand"},{"key":"R16-20230728","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1164\/ajrccm.164.3.2009042","article-title":"Ultrasonic examination: An alternative to chest radiography after central venous catheter insertion?","volume":"164","author":"Maury","year":"2001","journal-title":"Am J Respir Crit Care Med"},{"key":"R17-20230728","doi-asserted-by":"crossref","first-page":"1292","DOI":"10.1213\/01.ane.0000263240.89121.D0","article-title":"The real ultrasound revolution.","volume":"104","author":"Baumgarten","year":"2007","journal-title":"Anesth Analg"},{"key":"R18-20230728","doi-asserted-by":"crossref","first-page":"367","DOI":"10.1016\/S0196-0644(97)70349-4","article-title":"Emergency department ultrasound services by emergency physicians: Model for gaining hospital approval.","volume":"29","author":"Tandy","year":"1997","journal-title":"Ann Emerg Med"},{"key":"R19-20230728","first-page":"142","article-title":"Association between delays in central venous catheter utilization and organ dysfunction in patients with severe sepsis and septic shock.","volume":"39","author":"Kashiouris","year":"2011","journal-title":"Crit Care Med"},{"key":"R20-20230728","doi-asserted-by":"crossref","first-page":"842.e1","DOI":"10.1016\/j.ajem.2010.06.025","article-title":"Evaluation of proper above-the-diaphragm central venous catheter placement: The saline flush test.","volume":"29","author":"Liu","year":"2011","journal-title":"Am J Emerg Med"},{"key":"R21-20230728","doi-asserted-by":"crossref","first-page":"1345","DOI":"10.1378\/chest.108.5.1345","article-title":"A bedside ultrasound sign ruling out pneumothorax in the critically ill. Lung sliding.","volume":"108","author":"Lichtenstein","year":"1995","journal-title":"Chest"},{"key":"R22-20230728","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1197\/j.aem.2005.05.005","article-title":"A prospective comparison of supine chest radiography and bedside ultrasound for the diagnosis of traumatic pneumothorax.","volume":"12","author":"Blaivas","year":"2005","journal-title":"Acad Emerg Med"},{"key":"R23-20230728","doi-asserted-by":"crossref","first-page":"W65","DOI":"10.7326\/0003-4819-151-4-200908180-00136","article-title":"The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: Explanation and elaboration.","volume":"151","author":"Liberati","year":"2009","journal-title":"Ann Intern Med"},{"key":"R24-20230728","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: A revised tool for the quality assessment of diagnostic accuracy studies.","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"key":"R25-20230728","doi-asserted-by":"crossref","first-page":"1054","DOI":"10.1001\/jama.282.11.1054","article-title":"The hazards of scoring the quality of clinical trials for meta-analysis.","volume":"282","author":"J\u00fcni","year":"1999","journal-title":"JAMA"},{"key":"R26-20230728","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1186\/1471-2288-6-31","article-title":"Meta-DiSc: A software for meta-analysis of test accuracy data.","volume":"6","author":"Zamora","year":"2006","journal-title":"BMC Med Res Methodol"},{"key":"R27-20230728","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1136\/bmj.327.7414.557","article-title":"Measuring inconsistency in meta-analyses.","volume":"327","author":"Higgins","year":"2003","journal-title":"BMJ"},{"key":"R29-20230728","doi-asserted-by":"crossref","first-page":"882","DOI":"10.1016\/j.jclinepi.2005.01.016","article-title":"The performance of tests of publication bias and other sample size effects in systematic reviews of diagnostic test accuracy was assessed.","volume":"58","author":"Deeks","year":"2005","journal-title":"J Clin Epidemiol"},{"key":"R30-20230728","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1097\/CCM.0b013e3181c0328f","article-title":"Ultrasound localization of central vein catheter and detection of postprocedural pneumothorax: An alternative to chest radiography.","volume":"38","author":"Vezzani","year":"2010","journal-title":"Crit Care Med"},{"key":"R31-20230728","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s11739-012-0885-7","article-title":"Verification of correct central venous catheter placement in the emergency department: Comparison between ultrasonography and chest radiography.","volume":"8","author":"Zanobetti","year":"2013","journal-title":"Intern Emerg Med"},{"key":"R32-20230728","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.ajem.2013.10.001","article-title":"Contrast enhanced ultrasound vs chest x-ray to determine correct central venous catheter position.","volume":"32","author":"Cortellaro","year":"2014","journal-title":"Am J Emerg Med"},{"key":"R33-20230728","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.jss.2010.04.020","article-title":"Bedside ultrasound can safely eliminate the need for chest radiographs after central venous catheter placement: CVC sono in the surgical ICU (SICU).","volume":"163","author":"Matsushima","year":"2010","journal-title":"J Surg Res"},{"key":"R34-20230728","doi-asserted-by":"crossref","first-page":"1932","DOI":"10.1007\/s00134-013-3097-3","article-title":"Guidewire localization by transthoracic echocardiography during central venous catheter insertion: A periprocedural method to evaluate catheter placement.","volume":"39","author":"Bedel","year":"2013","journal-title":"Intensive Care Med"},{"key":"R35-20230728","doi-asserted-by":"crossref","first-page":"38","DOI":"10.4103\/0972-5229.148642","article-title":"Confirmation of endovenous placement of central catheter using the ultrasonographic \u201cbubble test\u201d.","volume":"19","author":"Baviskar","year":"2015","journal-title":"Indian J Crit Care Med"},{"key":"R36-20230728","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1016\/j.ajem.2014.10.010","article-title":"The bubble study: Ultrasound confirmation of central venous catheter placement.","volume":"33","author":"Duran-Gehring","year":"2015","journal-title":"Am J Emerg Med"},{"key":"R37-20230728","doi-asserted-by":"crossref","first-page":"65","DOI":"10.1111\/acem.12283","article-title":"Central vascular catheter placement evaluation using saline flush and bedside echocardiography.","volume":"21","author":"Weekes","year":"2014","journal-title":"Acad Emerg Med"},{"key":"R38-20230728","doi-asserted-by":"crossref","first-page":"e231","DOI":"10.1097\/CCM.0000000000000130","article-title":"Agitated saline bubble-enhanced transthoracic echocardiography: A novel method to visualize the position of central venous catheter.","volume":"42","author":"Wen","year":"2014","journal-title":"Crit Care Med"},{"key":"R39-20230728","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/01.ccm.0000424477.64751.91","article-title":"Confirmation of central venous catheter placement using ultrasound.","volume":"40","author":"Syed","year":"2012","journal-title":"Crit Care Med"},{"key":"R40-20230728","first-page":"S26","article-title":"Bedside ultrasound imaging for confirmation of central venous catheter position and to detect complications.","volume":"18","author":"Madhulika","year":"2014","journal-title":"Indian J Crit Care Med"},{"key":"R41-20230728","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.7863\/ultra.34.7.1295","article-title":"Saline flush test: Can bedside sonography replace conventional radiography for confirmation of above-the-diaphragm central venous catheter placement?","volume":"34","author":"Gekle","year":"2015","journal-title":"J Ultrasound Med"},{"key":"R42-20230728","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1136\/emermed-2015-205000","article-title":"Prospective comparison of ultrasound and CXR for confirmation of central vascular catheter placement.","volume":"33","author":"Weekes","year":"2016","journal-title":"Emerg Med J"},{"key":"R43-20230728","first-page":"989","article-title":"Confirmation of correct central venous catheter position in the preoperative setting by echocardiographic \u201cbubble-test\u201d.","volume":"81","author":"Meggiolaro","year":"2015","journal-title":"Minerva Anestesiol"},{"key":"R44-20230728","doi-asserted-by":"crossref","first-page":"1077","DOI":"10.1007\/s00134-011-2246-9","article-title":"International expert statement on training standards for critical care ultrasonography.","volume":"37","year":"2011","journal-title":"Intensive Care Med"},{"key":"R46-20230728","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1378\/chest.10-2946","article-title":"Diagnosis of pneumothorax by radiography and ultrasonography: A meta-analysis.","volume":"140","author":"Ding","year":"2011","journal-title":"Chest"},{"key":"R47-20230728","doi-asserted-by":"crossref","first-page":"R208","DOI":"10.1186\/cc13016","article-title":"Pleural ultrasonography versus chest radiography for the diagnosis of pneumothorax: Review of the literature and meta-analysis.","volume":"17","author":"Alrajab","year":"2013","journal-title":"Crit Care"},{"key":"R48-20230728","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1378\/chest.11-0131","article-title":"Test characteristics of ultrasonography for the detection of pneumothorax: A systematic review and meta-analysis.","volume":"141","author":"Alrajhi","year":"2012","journal-title":"Chest"},{"key":"R49-20230728","first-page":"29","article-title":"Diagnostic accuracy of chest ultrasonography versus chest radiography for identification of pneumothorax: A systematic review and meta-analysis.","volume":"13","author":"Ebrahimi","year":"2014","journal-title":"Tanaffos"},{"key":"R50-20230728","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1111\/acem.12255","article-title":"Understanding the direction of bias in studies of diagnostic test accuracy.","volume":"20","author":"Kohn","year":"2013","journal-title":"Acad Emerg Med"},{"key":"R51-20230728","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1017\/S1481803500009891","article-title":"Incorporation bias in studies of diagnostic tests: How to avoid being biased about bias.","volume":"10","author":"Worster","year":"2008","journal-title":"CJEM"},{"key":"R52-20230728","doi-asserted-by":"crossref","first-page":"623","DOI":"10.1111\/acem.12386","article-title":"Emergency physician perspectives on central venous catheterization in the emergency department: A survey-based study.","volume":"21","author":"Ballard","year":"2014","journal-title":"Acad Emerg Med"},{"key":"R53-20230728","first-page":"99","article-title":"Emergency medicine ultrasonography in rural communities.","volume":"17","author":"Flynn","year":"2012","journal-title":"Can J Rural Med"},{"key":"R54-20230728","doi-asserted-by":"crossref","first-page":"2345","DOI":"10.1097\/CCM.0b013e3181a067d4","article-title":"An unseen danger: Frequency of posterior vessel wall penetration by needles during attempts to place internal jugular vein central catheters using ultrasound guidance.","volume":"37","author":"Blaivas","year":"2009","journal-title":"Crit Care Med"},{"key":"R55-20230728","doi-asserted-by":"crossref","first-page":"e804","DOI":"10.1097\/CCM.0000000000001737","article-title":"Routine chest radiography is not necessary after ultrasound-guided right internal jugular vein catheterization.","volume":"44","author":"Hourmozdi","year":"2016","journal-title":"Crit Care Med"},{"key":"R56-20230728","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1097\/01.RVI.0000071097.76348.72","article-title":"Central venous catheter tip position: A continuing controversy.","volume":"14","author":"Vesely","year":"2003","journal-title":"J Vasc Interv Radiol"},{"key":"R57-20230728","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.medin.2010.07.003","article-title":"[Location of the central venous catheter tip in the right atrium: Description in 2348 critical patients].","volume":"34","author":"Torres-Mill\u00e1n","year":"2010","journal-title":"Med Intensiva"},{"key":"R58-20230728","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1053\/j.jvca.2014.05.020","article-title":"Late cardiac tamponade in adults secondary to tip position in the right atrium: An urban legend? A systematic review of the literature.","volume":"29","author":"Pittiruti","year":"2015","journal-title":"J Cardiothorac Vasc Anesth"}],"container-title":["Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003246-201704000-00019","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,7,28]],"date-time":"2023-07-28T09:11:29Z","timestamp":1690535489000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003246-201704000-00019"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,4]]},"references-count":56,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/ccm.0000000000002188","relation":{},"ISSN":["0090-3493"],"issn-type":[{"value":"0090-3493","type":"print"}],"subject":[],"published":{"date-parts":[[2017,4]]}}}