{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,20]],"date-time":"2026-11-20T06:43:48Z","timestamp":1795157028526,"version":"4.10.3"},"reference-count":49,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"10","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2024,10]]},"abstract":"<jats:sec>\n            <jats:title>OBJECTIVES:<\/jats:title>\n            <jats:p>To standardize optic nerve sheath diameter (ONSD) point-of-care ultrasonography (POCUS) and improve its research and clinical utility by developing the ONSD POCUS Quality Criteria Checklist (ONSD POCUS QCC).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>DESIGN:<\/jats:title>\n            <jats:p>Three rounds of modified Delphi consensus process and three rounds of asynchronous discussions.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SETTING:<\/jats:title>\n            <jats:p>Online surveys and anonymous asynchronous discussion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>SUBJECTS:<\/jats:title>\n            <jats:p>Expert panelists were identified according to their expertise in ONSD research, publication records, education, and clinical use. A total of 52 panelists participated in the Delphi process.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>INTERVENTIONS:<\/jats:title>\n            <jats:p>None.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n            <jats:p>Three Delphi rounds and three asynchronous discussion rounds generated consensus on quality criteria (QC). This started with 29 QC in addition to other QC proposed by expert panelists. The QC items were categorized into probe selection, safety, body position, imaging, measurement, and research considerations. At the conclusion of the study, 28 QC reached consensus to include in the final ONSD POCUS QCC. These QC were then reorganized, edited, and consolidated into 23 QC that were reviewed and approved by the panelists.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSIONS:<\/jats:title>\n            <jats:p>ONSD POCUS QCC standardizes ONSD ultrasound imaging and measurement based on international consensus. This can establish ONSD ultrasound in clinical research and improve its utility in clinical practice.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ccm.0000000000006345","type":"journal-article","created":{"date-parts":[[2024,6,5]],"date-time":"2024-06-05T14:31:34Z","timestamp":1717597894000},"page":"1543-1556","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":75,"title":["Optic Nerve Sheath Diameter Point-of-Care Ultrasonography Quality Criteria Checklist: An International Consensus Statement on Optic Nerve Sheath Diameter Imaging and Measurement*"],"prefix":"10.1097","volume":"52","author":[{"given":"Mohammad I.","family":"Hirzallah","sequence":"first","affiliation":[{"name":"Department of Neurology, Section of Neurocritical Care and Vascular Neurology, Baylor College of Medicine, Houston, TX."},{"name":"Center for Space Medicine, Baylor College of Medicine, Houston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Piergiorgio","family":"Lochner","sequence":"additional","affiliation":[{"name":"Department of Neurology Saarland University, Homburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Muhammad Ubaid","family":"Hafeez","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Texas Medical Branch at Galveston, Galveston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrew G.","family":"Lee","sequence":"additional","affiliation":[{"name":"Department of Ophthalmology, Houston Methodist hospital, Houston, TX."},{"name":"Department of Ophthalmology, Weill Cornell Medical College, New York, NY."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christos","family":"Krogias","sequence":"additional","affiliation":[{"name":"Department of Neurology, Evangelisches Krankenhaus Herne, Academic Teaching Hospital of the Ruhr University Bochum, Herne, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepa","family":"Dongarwar","sequence":"additional","affiliation":[{"name":"UT Health McGovern School of Medicine, Houston, TX."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nicholas D.","family":"Hartman","sequence":"additional","affiliation":[{"name":"Department of Emergency Medicine, Wake Forest School of Medicine, Winston-Salem, NC."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Ertl","sequence":"additional","affiliation":[{"name":"Department of Neurology and Clinical Neurophysiology, University Hospital Augsburg, Augsburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chiara","family":"Robba","sequence":"additional","affiliation":[{"name":"Department of Anesthesia and Intensive Care, IRCCS Policlinico San Martino, Genova, Italy."},{"name":"Dipartimento di Scienze Chirurgiche Diagnostiche Integrate, University of Genoa, Italy."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Branko","family":"Malojcic","sequence":"additional","affiliation":[{"name":"Department of Neurology, University Hospital Center Zagreb, Zagreb School of Medicine, Zagreb, Croatia."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jurgita","family":"Valaikiene","sequence":"additional","affiliation":[{"name":"Clinic of Neurology and Neurosurgery, Institute of Clinical Medicine, Faculty of Medicine, Vilnius University, Vilnius, Lithuania."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aarti","family":"Sarwal","sequence":"additional","affiliation":[{"name":"Department of Neurology, Atrium Health Wake Forest Baptist, Winston-Salem, NC."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan","family":"Hakimi","sequence":"additional","affiliation":[{"name":"Department of Medicine (Neurology Division), University of South Carolina School of Medicine-Greenville, Greenville, SC."},{"name":"American Society of Neuroimaging, Kimberly, WI."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Schlachetzki","sequence":"additional","affiliation":[{"name":"Department of Neurology, University of Regensburg, Center for Vascular Neurology and Intensive Care, Regensburg, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"name":"for the Optic Nerve Sheath Diameter Point-of-Care Ultrasonography Quality Criteria Checklist (ONSD POCUS QCC) Expert Panelists","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,6,5]]},"reference":[{"key":"R1-20250502","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/S0002-9394(14)73195-2","article-title":"Measurement and relationship of subarachnoid pressure of the optic nerve to intracranial pressures in fresh cadavers.","volume":"116","author":"Liu","year":"1993","journal-title":"Am J Ophthalmol"},{"key":"R2-20250502","doi-asserted-by":"crossref","first-page":"1704","DOI":"10.1007\/s00134-007-0797-6","article-title":"Ultrasonography of the optic nerve sheath may be useful for detecting raised intracranial pressure after severe brain injury.","volume":"33","author":"Geeraerts","year":"2007","journal-title":"Intensive Care Med"},{"key":"R3-20250502","first-page":"3589762","article-title":"New optic nerve sonography quality criteria in the diagnostic evaluation of traumatic brain injury.","volume":"2018","author":"Soliman","year":"2018","journal-title":"Crit Care Res Pract"},{"key":"R4-20250502","doi-asserted-by":"crossref","first-page":"e858","DOI":"10.1097\/PCC.0000000000002453","article-title":"Ultrasonographic optic nerve sheath diameter measurement to detect intracranial hypertension in children with neurological injury: A systematic review.","volume":"21","author":"Bhargava","year":"2020","journal-title":"Pediatr Crit Care Med"},{"key":"R5-20250502","doi-asserted-by":"crossref","first-page":"l4225","DOI":"10.1136\/bmj.l4225","article-title":"Diagnosis of elevated intracranial pressure in critically ill adults: Systematic review and meta-analysis.","volume":"366","author":"Fernando","year":"2019","journal-title":"BMJ"},{"key":"R6-20250502","doi-asserted-by":"crossref","first-page":"585","DOI":"10.1002\/jum.15732","article-title":"Optic nerve sheath diameter ultrasound for raised intracranial pressure: A literature review and meta-analysis of its diagnostic accuracy.","volume":"41","author":"Aletreby","year":"2022","journal-title":"J Ultrasound Med"},{"key":"R7-20250502","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1186\/s13089-021-00235-5","article-title":"Mean value of B-mode optic nerve sheath diameter as an indicator of increased intracranial pressure: A systematic review and meta-analysis.","volume":"13","author":"Montorfano","year":"2021","journal-title":"Ultrasound J"},{"key":"R8-20250502","doi-asserted-by":"crossref","first-page":"808","DOI":"10.1111\/jon.13018","article-title":"Quality assessment of optic nerve sheath diameter ultrasonography: Scoping literature review and Delphi protocol.","volume":"32","author":"Hirzallah","year":"2022","journal-title":"J Neuroimaging"},{"key":"R10-20250502","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s12028-019-00853-x","article-title":"A proposal for a new protocol for sonographic assessment of the optic nerve sheath diameter: The CLOSED protocol.","volume":"32","author":"Aspide","year":"2020","journal-title":"Neurocrit Care"},{"key":"R11-20250502","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1111\/jon.12578","article-title":"Simulation and experimental characterization of lateral imaging resolution of ultrasound systems and assessment of system suitability for acoustic optic nerve sheath diameter measurement.","volume":"29","author":"Lochner","year":"2019","journal-title":"J Neuroimaging"},{"key":"R12-20250502","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/0002-9394(56)91262-4","article-title":"Ultrasonics in ocular diagnosis.","volume":"41","author":"Mundt","year":"1956","journal-title":"Am J Ophthalmol"},{"key":"R13-20250502","first-page":"53","article-title":"Echographic measurement of the optic nerve in patients with intracranial hypertension.","volume":"30","author":"Gangemi","year":"1987","journal-title":"Neurochirurgia (Stuttg)"},{"key":"R14-20250502","doi-asserted-by":"crossref","first-page":"870808","DOI":"10.3389\/fmed.2022.870808","article-title":"Ultrasound detection of intracranial hypertension in brain injuries.","volume":"9","author":"Vitiello","year":"2022","journal-title":"Front Med"},{"key":"R15-20250502","doi-asserted-by":"crossref","first-page":"7396","DOI":"10.21037\/qims-23-628","article-title":"Systematic use of standardized A-scan technique in neurosurgical intensive care unit.","volume":"13","author":"Fioretto","year":"2023","journal-title":"Quant Imaging Med Surg"},{"key":"R16-20250502","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1007\/s12028-020-01000-7","article-title":"The authors reply: Ocular ultrasonography to detect intracranial hypertension in subarachnoid hemorrhage patients.","volume":"33","author":"Zoerle","year":"2020","journal-title":"Neurocrit Care"},{"key":"R17-20250502","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1016\/S0140-6736(05)78351-3","article-title":"Bacterial keratitis in the critically ill and comatose patient.","volume":"351","author":"Dua","year":"1998","journal-title":"Lancet"},{"key":"R18-20250502","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1016\/j.jtos.2011.10.001","article-title":"Common ocular surface disorders in patients in intensive care units.","volume":"10","author":"Grixti","year":"2012","journal-title":"Ocul Surf"},{"key":"R19-20250502","year":"2020"},{"key":"R20-20250502","year":"2019"},{"key":"R21-20250502","doi-asserted-by":"crossref","first-page":"1609","DOI":"10.1002\/jum.15864","article-title":"Ocular ultrasound: Review of bioeffects and safety, including fetal and point-of-care perspective.","volume":"41","author":"Abramowicz","year":"2022","journal-title":"J Ultrasound Med"},{"key":"R22-20250502","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1016\/j.ultrasmedbio.2015.09.016","article-title":"Comparison of thermal safety practice guidelines for diagnostic ultrasound exposures.","volume":"42","author":"Harris","year":"2016","journal-title":"Ultrasound Med Biol"},{"key":"R24-20250502","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.ajem.2022.08.044","article-title":"Covered or uncovered: A randomized control trial of Tegaderm versus no Tegaderm for ocular ultrasound.","volume":"61","author":"Marks","year":"2022","journal-title":"Am J Emerg Med"},{"key":"R25-20250502","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1136\/jnnp-2015-310853","article-title":"Management of spontaneous intracranial hypotension\u2014transorbital ultrasound as discriminator.","volume":"87","author":"Fichtner","year":"2016","journal-title":"J Neurol Neurosurg Psychiatry"},{"key":"R26-20250502","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1186\/s12871-015-0025-9","article-title":"Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position.","volume":"15","author":"Chin","year":"2015","journal-title":"BMC Anesthesiol"},{"key":"R27-20250502","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1186\/s12871-017-0333-3","article-title":"Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45\u00b0 Trendelenburg position.","volume":"17","author":"Blecha","year":"2017","journal-title":"BMC Anesthesiol"},{"key":"R28-20250502","doi-asserted-by":"crossref","first-page":"1139","DOI":"10.1152\/japplphysiol.00256.2017","article-title":"Lower body negative pressure reduces optic nerve sheath diameter during head-down tilt.","volume":"123","author":"Marshall-Goebel","year":"2017","journal-title":"J Appl Physiol (1985)"},{"key":"R29-20250502","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1111\/opo.13200","article-title":"Effects of head-down tilt on optic nerve sheath diameter in healthy subjects.","volume":"43","author":"Ustick","year":"2023","journal-title":"Ophthalmic Physiol Opt"},{"key":"R30-20250502","doi-asserted-by":"crossref","first-page":"103036","DOI":"10.1016\/j.autneu.2022.103036","article-title":"How does head position induced intracranial pressure changes impact sympathetic activity and cerebral blood flow?","volume":"243","author":"Kermorgant","year":"2022","journal-title":"Auton Neurosci"},{"key":"R31-20250502","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1111\/ene.13225","article-title":"Measuring changes in the optic nerve sheath diameter in patients with idiopathic normal-pressure hydrocephalus: A useful diagnostic supplement to spinal tap tests.","volume":"24","author":"Ertl","year":"2017","journal-title":"Eur J Neurol"},{"key":"R32-20250502","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1097\/OPX.0000000000001148","article-title":"Use of A-scan ultrasound and optical coherence tomography to differentiate papilledema from pseudopapilledema.","volume":"94","author":"Saenz","year":"2017","journal-title":"Optom Vis Sci"},{"key":"R33-20250502","doi-asserted-by":"crossref","first-page":"1826","DOI":"10.1167\/iovs.15-18718","article-title":"Optic nerve sheath as a novel mechanical load on the globe in ocular duction.","volume":"57","author":"Demer","year":"2016","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R34-20250502","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1007\/s12028-019-00881-7","article-title":"Comparison of three point-of-care ultrasound views and MRI measurements for optic nerve sheath diameter: A prospective validity study.","volume":"33","author":"Raval","year":"2020","journal-title":"Neurocrit Care"},{"key":"R35-20250502","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1177\/875647939501100603","article-title":"Image artifacts in real-time ultrasound.","volume":"11","author":"Hedrick","year":"1995","journal-title":"J Diagn Med Sonogr"},{"key":"R36-20250502","doi-asserted-by":"crossref","first-page":"1488","DOI":"10.1007\/s00134-009-1494-4","article-title":"Optic nerve ultrasound: Artifacts and real images.","volume":"35","author":"Copetti","year":"2009","journal-title":"Intensive Care Med"},{"key":"R37-20250502","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1111\/jon.12936","article-title":"Optic nerve sheath diameter measurement by ultrasound: Evaluation of a standardized protocol.","volume":"32","author":"Pansell","year":"2022","journal-title":"J Neuroimaging"},{"key":"R38-20250502","doi-asserted-by":"crossref","first-page":"2044","DOI":"10.1167\/iovs.16-21319","article-title":"Predictions of optic nerve traction forces and peripapillary tissue stresses following horizontal eye movements.","volume":"58","author":"Wang","year":"2017","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"R39-20250502","doi-asserted-by":"crossref","first-page":"58","DOI":"10.1111\/jon.13062","article-title":"Optic nerve sheath diameter in intracranial hypertension: Measurement external or internal of the dura mater?","volume":"33","author":"Pansell","year":"2023","journal-title":"J Neuroimaging"},{"key":"R40-20250502","doi-asserted-by":"crossref","first-page":"724","DOI":"10.1111\/jon.12851","article-title":"An automated algorithm for optic nerve sheath diameter assessment from B-mode ultrasound images.","volume":"31","author":"Stevens","year":"2021","journal-title":"J Neuroimaging"},{"key":"R41-20250502","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1186\/1471-2377-13-187","article-title":"Reproducibility and accuracy of optic nerve sheath diameter assessment using ultrasound compared to magnetic resonance imaging.","volume":"13","author":"B\u00e4uerle","year":"2013","journal-title":"BMC Neurol"},{"key":"R42-20250502","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1055\/s-0031-1273491","article-title":"Measurement of the optic nerve sheath diameter in children: Comparison between transbulbar sonography and magnetic resonance imaging.","volume":"33","author":"Steinborn","year":"2012","journal-title":"Ultraschall Med"},{"key":"R43-20250502","doi-asserted-by":"crossref","first-page":"608","DOI":"10.1055\/s-0029-1245822","article-title":"High resolution ultrasound and magnetic resonance imaging of the optic nerve and the optic nerve sheath: Anatomic correlation and clinical importance.","volume":"32","author":"Steinborn","year":"2011","journal-title":"Ultraschall Med"},{"key":"R44-20250502","doi-asserted-by":"crossref","first-page":"2014","DOI":"10.1007\/s00415-011-6059-0","article-title":"Sonographic assessment of the optic nerve sheath in idiopathic intracranial hypertension.","volume":"258","author":"B\u00e4uerle","year":"2011","journal-title":"J Neurol"},{"key":"R45-20250502","doi-asserted-by":"crossref","first-page":"1059","DOI":"10.1007\/s00134-011-2224-2","article-title":"Ultrasonography of optic nerve sheath diameter for detection of raised intracranial pressure: A systematic review and meta-analysis.","volume":"37","author":"Dubourg","year":"2011","journal-title":"Intensive Care Med"},{"key":"R46-20250502","doi-asserted-by":"crossref","first-page":"1285","DOI":"10.7863\/ultra.34.7.1285","article-title":"Sonography of the optic nerve sheath diameter for detection of raised intracranial pressure compared to computed tomography: A systematic review and meta-analysis.","volume":"34","author":"Ohle","year":"2015","journal-title":"J Ultrasound Med"},{"key":"R47-20250502","doi-asserted-by":"crossref","first-page":"100330","DOI":"10.1016\/j.ensci.2021.100330","article-title":"The role of optic nerve sheath diameter ultrasound in brain infection.","volume":"23","author":"Stead","year":"2021","journal-title":"eNeurologicalSci"},{"key":"R48-20250502","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1186\/s13054-020-03105-z","article-title":"Multimodal non-invasive assessment of intracranial hypertension: An observational study.","volume":"24","author":"Robba","year":"2020","journal-title":"Crit Care"},{"key":"R49-20250502","doi-asserted-by":"crossref","first-page":"1579","DOI":"10.7863\/ultra.16.05055","article-title":"Inter-rater reliability of sonographic optic nerve sheath diameter measurements by emergency medicine physicians.","volume":"36","author":"Oberfoell","year":"2017","journal-title":"J Ultrasound Med"},{"key":"R50-20250502","first-page":"11","article-title":"Utility of bedside ultrasound measurement of optic nerve sheath diameter as a screening tool for raised intracranial pressure in neurocritical care prospective observational study.","volume":"71","author":"Gurav","year":"2023","journal-title":"J Assoc Physicians India"},{"key":"R51-20250502","doi-asserted-by":"crossref","first-page":"3279","DOI":"10.1016\/j.ultrasmedbio.2020.08.025","article-title":"Normal age- and sex-related values of the optic nerve sheath diameter and its dependency on position and positive end-expiratory pressure.","volume":"46","author":"Ertl","year":"2020","journal-title":"Ultrasound Med Biol"}],"container-title":["Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCM.0000000000006345","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T16:01:36Z","timestamp":1746201696000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCM.0000000000006345"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6,5]]},"references-count":49,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2024]]}},"URL":"https:\/\/doi.org\/10.1097\/ccm.0000000000006345","relation":{},"ISSN":["0090-3493","1530-0293"],"issn-type":[{"value":"0090-3493","type":"print"},{"value":"1530-0293","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,6,5]]}}}