{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,27]],"date-time":"2026-10-27T00:04:29Z","timestamp":1793059469775,"version":"4.5.0"},"reference-count":9,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"11","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n                    <jats:title>OBJECTIVES:<\/jats:title>\n                    <jats:p>\n                      To assess the reliability of conventional automated oscillometric upper arm cuff (cuff\n                      <jats:sub>ARM<\/jats:sub>\n                      ): 1) when finger cuff monitoring (cuff\n                      <jats:sub>FINGER<\/jats:sub>\n                      ) of arterial pressure (AP) is suspected to be unreliable due to poor fingertip perfusion and\/or hand edema or 2) fails to provide a reading.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>DESIGN:<\/jats:title>\n                    <jats:p>Prospective observational study based on cohorts evaluating the CNAP (Dr\u00e4ger Medical) and ClearSight (Edwards Lifesciences) systems.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>SETTING:<\/jats:title>\n                    <jats:p>Three ICUs.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>PATIENTS:<\/jats:title>\n                    <jats:p>Adults with an arterial catheter and stable AP.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>INTERVENTIONS:<\/jats:title>\n                    <jats:p>\n                      Three sets of triplicate AP measurements\u2014simultaneous readings from the cuff\n                      <jats:sub>FINGER<\/jats:sub>\n                      , cuff\n                      <jats:sub>ARM<\/jats:sub>\n                      and, as a reference, arterial catheter\u2014were collected for each patient.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MEASUREMENTS AND MAIN RESULTS:<\/jats:title>\n                    <jats:p>\n                      We analyzed 352 patients: 214 with the CNAP and 138 with the ClearSight cuff\n                      <jats:sub>FINGER<\/jats:sub>\n                      . In the 102 patients (29%) with poor fingertip perfusion\u2014defined as a capillary refill time greater than 4 seconds\u2014and\/or hand edema, cuff\n                      <jats:sub>ARM<\/jats:sub>\n                      mean AP measurements (\n                      <jats:italic toggle=\"yes\">n<\/jats:italic>\n                      = 304) never failed, met the International Organization for Standardization (ISO) 81060-2:2018 standard (bias \u00b1\n                      <jats:sc>sd<\/jats:sc>\n                      : 2.2 \u00b1 7.2 mm Hg), posed no or low risk of harm in 99.7% of cases, and demonstrated good ability to detect hypotension and hypertension (area under the receiver operating characteristic curve, 0.91 [95% CI, 0.87\u20130.94] and 0.92 [95% CI, 0.75\u20131], respectively). In these 102 patients, cuff\n                      <jats:sub>FINGER<\/jats:sub>\n                      failed to display a reading in 17 patients (17%), and if not, did not meet the ISO 81060-2:2018 standard. In 38 of 352 patients (11%) in whom the cuff\n                      <jats:sub>FINGER<\/jats:sub>\n                      failed to display an AP measurement, cuff\n                      <jats:sub>ARM<\/jats:sub>\n                      met the ISO 81060-2:2018 standard for mean AP (bias \u00b1\n                      <jats:sc>sd<\/jats:sc>\n                      : 1.7 \u00b1 7.1 mm Hg). In the absence of failure and risk factors for erroneous measurements, ClearSight met the ISO 81060-2:2018 standard for mean AP, unlike the CNAP system.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSIONS:<\/jats:title>\n                    <jats:p>\n                      In a multimodal, noninvasive strategy for AP monitoring, ClearSight cuff\n                      <jats:sub>FINGER<\/jats:sub>\n                      may be suitable as a first-line tool due to its continuous nature. When unreliable or unavailable, cuff\n                      <jats:sub>ARM<\/jats:sub>\n                      provides reliable measurements, effectively detects hypotension and hypertension, and poses no significant risk to the patient.\n                    <\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/ccm.0000000000006841","type":"journal-article","created":{"date-parts":[[2025,8,14]],"date-time":"2025-08-14T14:00:18Z","timestamp":1755180018000},"page":"e2331-e2337","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Multimodal Noninvasive Monitoring of Arterial Pressure: Do Limitations of Finger Cuff Monitoring Compromise Upper Arm Measurements? A Post Hoc Analysis of Two Prospective Cohorts"],"prefix":"10.1097","volume":"53","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5311-3987","authenticated-orcid":false,"given":"Karim","family":"Lakhal","sequence":"first","affiliation":[{"name":"Department of Anesthesia and Critical Care, Nantes Universit\u00e9, Laennec Hospital, CHU Nantes, University Hospital of Nantes, Nantes, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J\u00e9r\u00f4me E.","family":"Dauvergne","sequence":"additional","affiliation":[{"name":"Department of Anesthesia and Critical Care, Nantes Universit\u00e9, Laennec Hospital, CHU Nantes, University Hospital of Nantes, Nantes, France."},{"name":"Institut du Thorax, Institut National de la Sant\u00e9 et de la Recherche M\u00e9dicale (INSERM), Centre National de la Recherche Scientifique (CNRS), Universit\u00e9 de Nantes, Nantes, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gr\u00e9goire","family":"Muller","sequence":"additional","affiliation":[{"name":"Service de M\u00e9decine Intensive-R\u00e9animation, Centre Hospitalier Universitaire d\u2019Orl\u00e9ans, Orl\u00e9ans, France."},{"name":"CRICS-TriggerSep F-CRIN Research Network, Tours France."},{"name":"Universit\u00e9 de Tours, EA4245, Transplantation, Immunologie, Inflammation, Tours, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stephan","family":"Ehrmann","sequence":"additional","affiliation":[{"name":"CRICS-TriggerSep F-CRIN Research Network, Tours France."},{"name":"CHRU Tours, M\u00e9decine Intensive R\u00e9animation, CIC INSERM 1415, Tours, France."},{"name":"INSERM, Centre d\u2019\u00e9tude des Pathologies Respiratoires, Tours, France."},{"name":"Universit\u00e9 de Tours, Tours, France."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thierry","family":"Boulain","sequence":"additional","affiliation":[{"name":"Service de M\u00e9decine Intensive-R\u00e9animation, Centre Hospitalier Universitaire d\u2019Orl\u00e9ans, Orl\u00e9ans, France."},{"name":"CRICS-TriggerSep F-CRIN Research Network, Tours France."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2025,8,14]]},"reference":[{"key":"R1-20251120","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1016\/j.chest.2017.10.030","article-title":"Noninvasive BP monitoring in the critically ill: Time to abandon the arterial catheter?","volume":"153","author":"Lakhal","year":"2018","journal-title":"Chest"},{"key":"R2-20251120","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.bja.2020.03.013","article-title":"Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: A systematic review and meta-analysis.","volume":"125","author":"Saugel","year":"2020","journal-title":"Br J Anaesth"},{"key":"R3-20251120","first-page":"101333","article-title":"Risk factors for poor performance in finger cuff non-invasive monitoring of arterial pressure: A prospective multicenter study.","volume":"43","author":"Lakhal","year":"2024","journal-title":"Anaesth Crit Care Pain Med"},{"key":"R5-20251120","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1213\/ANE.0000000000002585","article-title":"Error grid analysis for arterial pressure method comparison studies.","volume":"126","author":"Saugel","year":"2018","journal-title":"Anesth Analg"},{"key":"R6-20251120","doi-asserted-by":"crossref","first-page":"1126","DOI":"10.1213\/ANE.0000000000001324","article-title":"The CNAPTM finger cuff for noninvasive beat-to-beat monitoring of arterial blood pressure: An evaluation in intensive care unit patients and a comparison with 2 intermittent devices.","volume":"123","author":"Lakhal","year":"2016","journal-title":"Anesth Analg"},{"key":"R7-20251120","doi-asserted-by":"crossref","first-page":"1350","DOI":"10.1097\/CCM.0000000000005945","article-title":"Noninvasive monitoring of arterial pressure: Finger or lower leg as alternatives to the upper arm: A prospective study in three ICUs.","volume":"51","author":"Lakhal","year":"2023","journal-title":"Crit Care Med"},{"key":"R8-20251120","doi-asserted-by":"crossref","first-page":"540","DOI":"10.1093\/bja\/aev304","article-title":"Blood pressure monitoring during arrhythmia: Agreement between automated brachial cuff and intra-arterial measurements.","volume":"115","author":"Lakhal","year":"2015","journal-title":"Br J Anaesth"},{"key":"R9-20251120","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1007\/s10877-017-0067-2","article-title":"Non-invasive blood pressure monitoring with an oscillometric brachial cuff: Impact of arrhythmia.","volume":"32","author":"Lakhal","year":"2018","journal-title":"J Clin Monit Comput"},{"key":"R10-20251120","doi-asserted-by":"crossref","first-page":"e0168321","DOI":"10.1371\/journal.pone.0168321","article-title":"Application of mixed effects limits of agreement in the presence of multiple sources of variability: Exemplar from the comparison of several devices to measure respiratory rate in COPD patients.","volume":"11","author":"Parker","year":"2016","journal-title":"PLoS One"}],"container-title":["Critical Care Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CCM.0000000000006841","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,11,20]],"date-time":"2025-11-20T16:02:46Z","timestamp":1763654566000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CCM.0000000000006841"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,8,14]]},"references-count":9,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/ccm.0000000000006841","relation":{},"ISSN":["0090-3493","1530-0293"],"issn-type":[{"value":"0090-3493","type":"print"},{"value":"1530-0293","type":"electronic"}],"subject":[],"published":{"date-parts":[[2025,8,14]]}}}