{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T07:50:48Z","timestamp":1790754648314,"version":"4.1.0"},"reference-count":60,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"1","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2017,1]]},"abstract":"<jats:sec>\n            <jats:title>Purpose of review<\/jats:title>\n            <jats:p>Recurrent laryngeal nerve (RLN) injury is one of the most common and serious complications associated with thyroid and parathyroid surgery. Although routine visual identification of the RLN is considered the current standard of care, the role of intraoperative neuromonitoring (IONM) of the RLN is more controversial.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Recent findings<\/jats:title>\n            <jats:p>Despite initial enthusiasm that IONM might substantially reduce the rate of RLN injury, most studies failed to show a significant difference in the rate of RLN injury when the use of IONM was compared with visualization of the RLN alone. However, a small number of investigators have reported statistically significant differences in the rates of nerve injury when IONM is used to augment visualization alone, particularly in certain high-risk situations. Despite a lack of conclusive data showing benefit, the use of IONM as an adjunct to visual identification of the RLN has gained increasing acceptance among surgeons. IONM remains an excellent tool to help verify the identity of the RLN, confirm its functional integrity, and pinpoint the site of nerve injury in the event of dysfunction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Summary<\/jats:title>\n            <jats:p>The utility of IONM in reducing the rate of RLN injury is largely unproven and remains controversial. However, the use of IONM may be helpful in certain high-risk cases. Promising new technology, such as vagal nerve monitoring, may allow more real-time monitoring of the functional integrity of the RLN and allow the surgeon to react in a timely manner to evolving dysfunction in order to abort maneuvers that may risk definitive injury.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/cco.0000000000000334","type":"journal-article","created":{"date-parts":[[2016,10,15]],"date-time":"2016-10-15T08:26:23Z","timestamp":1476519983000},"page":"14-19","source":"Crossref","is-referenced-by-count":16,"title":["An update on the status of nerve monitoring for thyroid\/parathyroid surgery"],"prefix":"10.1097","volume":"29","author":[{"given":"Ho-Sheng","family":"Lin","sequence":"first","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, Wayne State University and Karmanos Cancer Institute"},{"name":"Department of Surgery, John D. Dingell VA Medical Center, Detroit, Michigan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David J.","family":"Terris","sequence":"additional","affiliation":[{"name":"Department of Otolaryngology-Head and Neck Surgery, Augusta University, Augusta, Georgia, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230901","doi-asserted-by":"crossref","first-page":"624","DOI":"10.1111\/j.1742-1241.2008.01875.x","article-title":"Diagnosis of recurrent laryngeal nerve palsy after thyroidectomy: a systematic review","volume":"63","author":"Jeannon","year":"2009","journal-title":"Int J Clin Pract"},{"key":"R2-20230901","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1177\/0194599813487301","article-title":"Clinical practice guideline: improving voice outcomes after thyroid surgery","volume":"148","author":"Chandrasekhar","year":"2013","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R3-20230901","doi-asserted-by":"crossref","first-page":"1487","DOI":"10.1002\/hed.24468","article-title":"Successful intraoperative electrophysiologic monitoring of the recurrent laryngeal nerve, a multidisciplinary approach: The Massachusetts Eye and Ear Infirmary monitoring collaborative protocol with experience in over 3000 cases","volume":"38","author":"Macias","year":"2016","journal-title":"Head Neck"},{"key":"R4-20230901","doi-asserted-by":"crossref","first-page":"743","DOI":"10.1016\/j.surg.2008.02.006","article-title":"The mechanism of recurrent laryngeal nerve injury during thyroid surgery \u2013 the application of intraoperative neuromonitoring","volume":"143","author":"Chiang","year":"2008","journal-title":"Surgery"},{"key":"R5-20230901","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1177\/0194599811430898","article-title":"Thyroidectomy-related malpractice claims","volume":"146","author":"Singer","year":"2012","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R6-20230901","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1097\/00000658-200202000-00015","article-title":"Laryngeal recurrent nerve injury in surgery for benign thyroid diseases: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk","volume":"235","author":"Hermann","year":"2002","journal-title":"Ann Surg"},{"key":"R7-20230901","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.surg.2004.07.018","article-title":"Risk factors of paralysis and functional outcome after recurrent laryngeal nerve monitoring in thyroid surgery","volume":"136","author":"Dralle","year":"2004","journal-title":"Surgery"},{"key":"R8-20230901","doi-asserted-by":"crossref","first-page":"895","DOI":"10.1177\/0194599812439278","article-title":"Laryngeal nerve monitoring: current utilization among head and neck surgeons","volume":"146","author":"Singer","year":"2012","journal-title":"Otolaryngol Head Neck Surg"},{"key":"R9-20230901","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1007\/s00268-008-9724-4","article-title":"Neuromonitoring in thyroid surgery: attitudes, usage patterns, and predictors of use among endocrine surgeons","volume":"33","author":"Sturgeon","year":"2009","journal-title":"World J Surg"},{"issue":"(Suppl 33)","key":"R10-20230901","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1177\/014107689809133S02","article-title":"The history of thyroidectomy","volume":"91","author":"Giddings","year":"1998","journal-title":"J R Soc Med"},{"key":"R11-20230901","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1097\/00000658-193810000-00006","article-title":"Injuries to the recurrent laryngeal nerve in thyroid operations: their management and avoidance","volume":"108","author":"Lahey","year":"1938","journal-title":"Ann Surg"},{"key":"R12-20230901","doi-asserted-by":"crossref","first-page":"638","DOI":"10.1016\/S0140-6736(56)92333-9","article-title":"Injury to recurrent laryngeal nerves during thyroidectomy; a comparison between the results of identification and nonidentification in 1022 nerves exposed to risk","volume":"271","author":"Riddell","year":"1956","journal-title":"Lancet"},{"key":"R13-20230901","doi-asserted-by":"crossref","first-page":"1335","DOI":"10.1007\/s002680010221","article-title":"Multivariate analysis of risk factors for postoperative complications in benign goiter surgery: prospective multicenter study in Germany","volume":"24","author":"Thomusch","year":"2000","journal-title":"World J Surg"},{"key":"R14-20230901","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.1007\/s00268-008-9483-2","article-title":"Intraoperative monitoring of the recurrent laryngeal nerve in thyroid surgery","volume":"32","author":"Dralle","year":"2008","journal-title":"World J Surg"},{"key":"R15-20230901","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1016\/j.surg.2005.08.027","article-title":"Intraoperative neurophysiology testing of the recurrent laryngeal nerve: plaudits and pitfalls","volume":"138","author":"Snyder","year":"2005","journal-title":"Surgery"},{"key":"R16-20230901","doi-asserted-by":"crossref","first-page":"866","DOI":"10.1016\/j.surg.2006.07.017","article-title":"The role of intraoperative neuromonitoring of recurrent laryngeal nerve during thyroidectomy: a comparative study on 1000 nerves at risk","volume":"140","author":"Chan","year":"2006","journal-title":"Surgery"},{"key":"R17-20230901","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1916-0216-43-16","article-title":"Identification alone versus intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: experience of 2034 consecutive patients","volume":"43","author":"Calo","year":"2014","journal-title":"J Otolaryngol Head Neck Surg"},{"key":"R18-20230901","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/BF03017855","article-title":"Laryngeal nerve identification during thyroid surgery \u2013 feasibility of a novel approach","volume":"50","author":"Hillermann","year":"2003","journal-title":"Can J Anaesth"},{"key":"R19-20230901","doi-asserted-by":"crossref","first-page":"1005","DOI":"10.1177\/000348940211101110","article-title":"Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation in predicting postoperative nerve paralysis","volume":"111","author":"Otto","year":"2002","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R20-20230901","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1007\/s00268-004-7348-x","article-title":"Recurrent laryngeal nerve identification and assessment during thyroid surgery: laryngeal palpation","volume":"28","author":"Randolph","year":"2004","journal-title":"World J Surg"},{"key":"R21-20230901","doi-asserted-by":"crossref","first-page":"811","DOI":"10.1177\/000348940211100909","article-title":"Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery","volume":"111","author":"Tschopp","year":"2002","journal-title":"Ann Otol Rhinol Laryngol"},{"key":"R22-20230901","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1097\/01.sla.0000132260.34503.02","article-title":"Neuromonitoring in thyroid surgery: prospective evaluation of intraoperative electrophysiological responses for the prediction of recurrent laryngeal nerve injury","volume":"240","author":"Hermann","year":"2004","journal-title":"Ann Surg"},{"key":"R23-20230901","doi-asserted-by":"crossref","first-page":"240","DOI":"10.1002\/bjs.6417","article-title":"Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomy","volume":"96","author":"Barczynski","year":"2009","journal-title":"Br J Surg"},{"key":"R24-20230901","doi-asserted-by":"crossref","first-page":"1009","DOI":"10.1002\/lary.21578","article-title":"Recurrent laryngeal nerve monitoring versus identification alone on postthyroidectomy true vocal fold palsy: a meta-analysis","volume":"121","author":"Higgins","year":"2011","journal-title":"Laryngoscope"},{"key":"R25-20230901","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1007\/s00268-011-0963-4","article-title":"Influence of intraoperative neuromonitoring on surgeons\u2019 technique during thyroidectomy","volume":"35","author":"Duclos","year":"2011","journal-title":"World J Surg"},{"key":"R26-20230901","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1590\/S1516-31802007000300011","article-title":"Vocal fold immobility after thyroidectomy with intraoperative recurrent laryngeal nerve monitoring","volume":"125","author":"Netto Ide","year":"2007","journal-title":"Sao Paulo Med J"},{"key":"R27-20230901","doi-asserted-by":"crossref","first-page":"1107","DOI":"10.1016\/j.surg.2004.06.040","article-title":"Intraoperative electromyographic monitoring of the recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery","volume":"136","author":"Yarbrough","year":"2004","journal-title":"Surgery"},{"key":"R28-20230901","doi-asserted-by":"crossref","first-page":"152","DOI":"10.1016\/j.jss.2013.12.022","article-title":"Systematic review with meta-analysis of studies comparing intraoperative neuromonitoring of recurrent laryngeal nerves versus visualization alone during thyroidectomy","volume":"188","author":"Pisanu","year":"2014","journal-title":"J Surg Res"},{"key":"R29-20230901","doi-asserted-by":"crossref","first-page":"1254","DOI":"10.1001\/archotol.133.12.1254","article-title":"Laryngeal nerve monitoring and minimally invasive thyroid surgery: complementary technologies","volume":"133","author":"Terris","year":"2007","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R30-20230901","doi-asserted-by":"crossref","first-page":"2051","DOI":"10.1007\/s00268-016-3594-y","article-title":"Intraoperative neuromonitoring in thyroid surgery: a systematic review","volume":"40","author":"Malik","year":"2016","journal-title":"World J Surg"},{"key":"R31-20230901","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1016\/S0002-9610(02)00856-5","article-title":"Intraoperative neuromonitoring of surgery for benign goiter","volume":"183","author":"Thomusch","year":"2002","journal-title":"Am J Surg"},{"key":"R32-20230901","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1089\/thy.2015.0020","article-title":"2015 American Thyroid Association Management Guidelines for Adult Patients with Thyroid Nodules and Differentiated Thyroid Cancer: The American Thyroid Association Guidelines Task Force on Thyroid Nodules and Differentiated Thyroid Cancer","volume":"26","author":"Haugen","year":"2016","journal-title":"Thyroid"},{"key":"R33-20230901","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/00005537-200201000-00022","article-title":"Advantages of recurrent laryngeal nerve identification in thyroidectomy and parathyroidectomy and the importance of preoperative and postoperative laryngoscopic examination in more than 1000 nerves at risk","volume":"112","author":"Steurer","year":"2002","journal-title":"Laryngoscope"},{"issue":"(Suppl 1)","key":"R34-20230901","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1002\/lary.21119","article-title":"Electrophysiologic recurrent laryngeal nerve monitoring during thyroid and parathyroid surgery: international standards guideline statement","volume":"121","author":"Randolph","year":"2011","journal-title":"Laryngoscope"},{"key":"R35-20230901","doi-asserted-by":"crossref","first-page":"474","DOI":"10.1016\/j.ijsu.2010.06.009","article-title":"Evaluation of recurrent laryngeal nerve monitoring in thyroid surgery","volume":"8","author":"Sari","year":"2010","journal-title":"Int J Surg"},{"key":"R36-20230901","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/s00268-009-0316-8","article-title":"Standardization of intraoperative neuromonitoring of recurrent laryngeal nerve in thyroid operation","volume":"34","author":"Chiang","year":"2010","journal-title":"World J Surg"},{"key":"R37-20230901","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1016\/j.jamcollsurg.2007.07.017","article-title":"Elucidating mechanisms of recurrent laryngeal nerve injury during thyroidectomy and parathyroidectomy","volume":"206","author":"Snyder","year":"2008","journal-title":"J Am Coll Surg"},{"key":"R38-20230901","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1097\/MOO.0b013e32834fa8e6","article-title":"Neuromonitoring in thyroid surgery","volume":"20","author":"Cernea","year":"2012","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"R39-20230901","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1007\/s00423-003-0444-9","article-title":"Validity of intra-operative neuromonitoring signals in thyroid surgery","volume":"389","author":"Thomusch","year":"2004","journal-title":"Langenbecks Arch Surg"},{"key":"R40-20230901","doi-asserted-by":"crossref","first-page":"1230","DOI":"10.1007\/s00268-005-0351-z","article-title":"Sensitivity and specificity of intraoperative recurrent laryngeal nerve stimulation test for predicting vocal cord palsy after thyroid surgery","volume":"30","author":"Tomoda","year":"2006","journal-title":"World J Surg"},{"key":"R41-20230901","doi-asserted-by":"crossref","first-page":"928","DOI":"10.1111\/j.1445-2197.2006.03899.x","article-title":"Extralaryngeal bifurcation of the recurrent laryngeal nerve: a common variation","volume":"76","author":"Beneragama","year":"2006","journal-title":"ANZ J Surg"},{"key":"R42-20230901","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1097\/00000658-200104000-00016","article-title":"Injury to the superior laryngeal branch of the vagus during thyroidectomy: lesson or myth?","volume":"233","author":"Crookes","year":"2001","journal-title":"Ann Surg"},{"key":"R43-20230901","doi-asserted-by":"crossref","first-page":"1412","DOI":"10.1136\/bmj.289.6456.1412","article-title":"Voice changes after thyroidectomy: role of the external laryngeal nerve","volume":"289","author":"Kark","year":"1984","journal-title":"Br Med J (Clin Res Ed)"},{"key":"R44-20230901","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1002\/hed.2880170108","article-title":"Superior laryngeal nerve injury from thyroid surgery","volume":"17","author":"Teitelbaum","year":"1995","journal-title":"Head Neck"},{"key":"R45-20230901","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1017\/S0022215100108412","article-title":"Cricothyroid muscle paralysis: its recognition and diagnosis","volume":"103","author":"Bevan","year":"1989","journal-title":"J Laryngol Otol"},{"key":"R46-20230901","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1002\/hed.2880140507","article-title":"Surgical anatomy of the external branch of the superior laryngeal nerve","volume":"14","author":"Cernea","year":"1992","journal-title":"Head Neck"},{"key":"R47-20230901","doi-asserted-by":"crossref","first-page":"1340","DOI":"10.1007\/s00268-012-1547-7","article-title":"Randomized controlled trial of visualization versus neuromonitoring of the external branch of the superior laryngeal nerve during thyroidectomy","volume":"36","author":"Barczynski","year":"2012","journal-title":"World J Surg"},{"issue":"(Suppl 1)","key":"R48-20230901","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.1016\/S1743-9191(13)60014-X","article-title":"Continuous monitoring of the recurrent laryngeal nerve in thyroid surgery: a critical appraisal","volume":"11","author":"Dionigi","year":"2013","journal-title":"Int J Surg"},{"key":"R49-20230901","doi-asserted-by":"crossref","first-page":"1591","DOI":"10.1002\/hed.23187","article-title":"Continuous intraoperative vagus nerve stimulation for identification of imminent recurrent laryngeal nerve injury","volume":"35","author":"Schneider","year":"2013","journal-title":"Head Neck"},{"key":"R50-20230901","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1177\/1553350611409955","article-title":"New backstrap vagus electrode for continuous intraoperative neuromonitoring in thyroid surgery","volume":"18","author":"Lamade","year":"2011","journal-title":"Surg Innov"},{"key":"R51-20230901","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/j.surg.2007.10.007","article-title":"Real-time monitoring of the recurrent laryngeal nerve: an observational clinical trial","volume":"143","author":"Ulmer","year":"2008","journal-title":"Surgery"},{"key":"R52-20230901","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1055\/s-0030-1262697","article-title":"Continuous intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery (CIONM) - Where are we now? An update to the European Symposium of Continuous Neuromonitoring in Thyroid Surgery","volume":"137","author":"Schneider","year":"2012","journal-title":"Zentralbl Chir"},{"key":"R53-20230901","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/j.amjsurg.2009.04.036","article-title":"A new vagal anchor electrode for real-time monitoring of the recurrent laryngeal nerve","volume":"199","author":"Schneider","year":"2010","journal-title":"Am J Surg"},{"key":"R54-20230901","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1007\/s00268-012-1853-0","article-title":"Evolution of nerve injury with unexpected EMG signal recovery in thyroid surgery using continuous intraoperative neuromonitoring","volume":"37","author":"Schneider","year":"2013","journal-title":"World J Surg"},{"key":"R55-20230901","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1001\/archoto.2008.520","article-title":"Recurrent laryngeal nerve monitoring during thyroidectomy and related cervical procedures in the pediatric population","volume":"135","author":"White","year":"2009","journal-title":"Arch Otolaryngol Head Neck Surg"},{"key":"R56-20230901","doi-asserted-by":"crossref","first-page":"2471","DOI":"10.1007\/s00268-015-3139-9","article-title":"Continuous vagal nerve monitoring is dangerous and should not routinely be done during thyroid surgery","volume":"39","author":"Terris","year":"2015","journal-title":"World J Surg"},{"key":"R57-20230901","doi-asserted-by":"crossref","first-page":"E2419","DOI":"10.1002\/hed.24358","article-title":"Cardiac arrest with vagal stimulation during intraoperative nerve monitoring","volume":"38","author":"Almquist","year":"2016","journal-title":"Head Neck"},{"key":"R58-20230901","doi-asserted-by":"crossref","first-page":"401","DOI":"10.5664\/JCSM.1204","article-title":"Obstructive sleep apnea and respiratory complications associated with vagus nerve stimulators","volume":"7","author":"Parhizgar","year":"2011","journal-title":"J Clin Sleep Med"},{"key":"R59-20230901","doi-asserted-by":"crossref","first-page":"1452","DOI":"10.1111\/j.1528-1157.1999.tb02019.x","article-title":"Bradycardia and asystole with the use of vagus nerve stimulation for the treatment of epilepsy: a rare complication of intraoperative device testing","volume":"40","author":"Asconape","year":"1999","journal-title":"Epilepsia"},{"key":"R60-20230901","doi-asserted-by":"crossref","first-page":"1241","DOI":"10.1213\/01.ane.0000244532.71743.c6","article-title":"Vagal nerve stimulation: overview and implications for anesthesiologists","volume":"103","author":"Hatton","year":"2006","journal-title":"Anesth Analg"}],"container-title":["Current Opinion in Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00001622-201701000-00004","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,1]],"date-time":"2023-09-01T06:36:09Z","timestamp":1693550169000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00001622-201701000-00004"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":60,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017]]}},"URL":"https:\/\/doi.org\/10.1097\/cco.0000000000000334","relation":{},"ISSN":["1040-8746","1531-703X"],"issn-type":[{"value":"1040-8746","type":"print"},{"value":"1531-703X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,1]]}}}