{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:09:20Z","timestamp":1788898160773,"version":"build-2803163510"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"9","funder":[{"name":"none"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    Smart infusion pumps are widely used to reduce medication errors. When integrated with electronic medical records (EMR), they support a closed-loop medication management system. This study evaluates the impact of EMR-smart pump interoperability on patient safety and user acceptability in a multicenter Australian health service. A comparative study was conducted using baseline data from a tertiary hospital without smart pump integration (December 2021 to July 2022) and post-implementation data from the newly established digital cardiac hospital (March 2023 to December 2023). Both sites utilized a coronary care-specific medication library to ensure consistency. The evaluation focused on key indicators such as medication library compliance, the frequency of pump reprogramming and high-risk medication alerts, the number of keystrokes required for programming, and the rate of alert overrides. An anonymous survey captured nursing staff perceptions related to satisfaction, workflow efficiency, and confidence in using the pump systems. Following the implementation EMR-smart pump interoperability, medication library compliance improved significantly, rising from 93% to 97%,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;.0001. Alerts related to pump reprogramming and high-risk medications also increased, suggesting enhanced safety monitoring. At the same time, programming became more efficient, with the average number of keystrokes required dropping from 13\u00b13.4 to 3\u00b11.2,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;.0001. However, despite these gains, survey responses revealed a decline in clinician\u2019s perceived ease of use (from 90% to 45%,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;.0001) and confidence in programming (93% to 65%,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;.0001). While the rate of cancelled infusions alerts (20% vs. 14%,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;.0001) and all other nonspecific pump alerts (23% vs. 16%,\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt;.0001) reduced. The integration of EMR-smart pump interoperability enhances medication safety by increasing the frequency of clinical alerts and reducing manual data entry. However, this advancement may introduce usability challenges that impact staff confidence and workflow. These findings highlight the importance of balancing technological integration with user experience to optimize patient safety outcomes.\n                  <\/jats:p>","DOI":"10.1097\/cin.0000000000001514","type":"journal-article","created":{"date-parts":[[2026,3,17]],"date-time":"2026-03-17T21:00:08Z","timestamp":1773781208000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Improving Patient Safety Through EMR-smart Pump Interoperability"],"prefix":"10.1097","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1826-4381","authenticated-orcid":false,"given":"Viviane","family":"Khalil","sequence":"first","affiliation":[{"name":"Monash Health, Clayton, Victoria, Australia"},{"name":"School of Psychology and Public Health, Latrobe University, Melbourne, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Madonna","family":"Dixon","sequence":"additional","affiliation":[{"name":"Monash Health, Clayton, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amelia","family":"Rattle","sequence":"additional","affiliation":[{"name":"Monash Health, Clayton, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Julie","family":"Ngo","sequence":"additional","affiliation":[{"name":"Monash Health, Clayton, Victoria, Australia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,9]]},"reference":[{"issue":"2","key":"R1-20260908","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1056\/NEJMsa2206117","article-title":"The safety of inpatient health care","volume":"388","author":"Bates","year":"2023","journal-title":"The New England Journal of Medicine"},{"key":"R2-20260908","first-page":"247","article-title":"Evaluating the impact of smart infusion pump interoperability on reducing medication administration errors: a systematic literature review","volume":"18","author":"Borrelli","year":"2025","journal-title":"Medical Devices: Evidence and Research"},{"key":"R3-20260908","first-page":"1","article-title":"Sentinel Event Alert Issue 63: optimizing smart infusion pump safety with DERS","volume":"63","author":"Joint Commission","year":"2021","journal-title":"The Joint Commission Journal on Quality and Patient Safety"},{"key":"R4-20260908","first-page":"1","article-title":"Guidelines for optimizing safe implementation and use of smart infusion pumps","year":"2020","journal-title":"Institute for Safe Medical Practices"},{"issue":"3","key":"R5-20260908","first-page":"210","article-title":"Impact of smart pump interoperability on medication administration errors: a retrospective observational study","volume":"18","author":"Oh","year":"2022","journal-title":"Journal of Patient Safety"},{"issue":"1","key":"R6-20260908","doi-asserted-by":"crossref","first-page":"e1","DOI":"10.51256\/ANJ012533","article-title":"Smart pump technology and dose error reduction","volume":"20","author":"Carrington-Hahn","year":"2025","journal-title":"American Nurse Journal"},{"issue":"3","key":"R7-20260908","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1002\/nop2.1227","article-title":"A qualitative analysis of intravenous smart pump usability","volume":"9","author":"Blake","year":"2022","journal-title":"Nursing Open"},{"issue":"8","key":"R8-20260908","first-page":"e1101","article-title":"Smart pump\u2013electronic health record interoperability: a national survey of infusion safety practices","volume":"17","author":"Woods","year":"2021","journal-title":"Journal of Patient Safety"},{"issue":"2","key":"R9-20260908","first-page":"81","article-title":"The impact of smart pump\u2013EMR interoperability on nurse efficiency and medication administration errors","volume":"39","author":"Giuliano","year":"2021","journal-title":"Computers, informatics, nursing : CIN"},{"issue":"2","key":"R10-20260908","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1136\/bmjqs-2015-004465","article-title":"The frequency of intravenous medication administration errors related to smart infusion pumps: a multihospital observational study","volume":"26","author":"Schnock","year":"2023","journal-title":"BMJ Quality & Safety"},{"issue":"1","key":"R11-20260908","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1093\/ajhp\/zxad245","article-title":"Data-based program management of system-wide IV smart pump integration","volume":"81","author":"Giuliano","year":"2024","journal-title":"American Journal of Health-System Pharmacy"},{"issue":"4","key":"R12-20260908","first-page":"1","article-title":"Closed-loop medication management systems","volume":"2","author":"Gates","year":"2021","journal-title":"Evidence Briefings on Interventions to Improve Medication Safety"},{"key":"R15-20260908","doi-asserted-by":"crossref","first-page":"507","DOI":"10.2147\/CEOR.S534748","article-title":"Enhancing patient safety and charge capture through smart infusion pump interoperability: a health economic analysis for US health systems","volume":"17","author":"Borrelli","year":"2025","journal-title":"ClinicoEconomics and Outcomes Research : CEOR."},{"issue":"8","key":"R16-20260908","doi-asserted-by":"crossref","first-page":"881","DOI":"10.1007\/s40264-022-01203-1","article-title":"Developing strategic recommendations for implementing smart pumps in advanced healthcare systems to improve intravenous medication safety","volume":"45","author":"Sutherland","year":"2022","journal-title":"Drug Safety"},{"issue":"5","key":"R18-20260908","first-page":"1","article-title":"Electronic prescribing systems and their impact on patient safety in hospitals","volume":"2","author":"Gates","year":"2021","journal-title":"Evidence Briefings on Interventions to Improve Medication Safety"},{"issue":"2","key":"R22-20260908","first-page":"e150","article-title":"Smart infusion pump\u2013electronic health record interoperability: a scoping review","volume":"19","author":"Ohashi","year":"2023","journal-title":"Journal of Patient Safety"},{"key":"R23-20260908","doi-asserted-by":"crossref","first-page":"zxab287","DOI":"10.1093\/ajhp\/zxab287","article-title":"Impact of smart pump-electronic health record interoperability on patient safety and finances at a community hospital","author":"Wei","year":"2021","journal-title":"American Journal of Health-System Pharmacy"},{"issue":"8","key":"R24-20260908","first-page":"e879","article-title":"Integration of smart infusion pump information with EHR data to analyze error-prone phases of the medication lifecycle","volume":"17","author":"Hertig","year":"2021","journal-title":"Journal of Patient Safety"}],"container-title":["CIN: Computers, Informatics, Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/CIN.0000000000001514","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T20:00:29Z","timestamp":1788897629000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/CIN.0000000000001514"}},"subtitle":["A Mixed-methods Study in an Australian Health Service"],"short-title":[],"issued":{"date-parts":[[2026,3,17]]},"references-count":18,"journal-issue":{"issue":"9","published-online":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/cin.0000000000001514","relation":{},"ISSN":["1538-9774","1538-2931"],"issn-type":[{"value":"1538-9774","type":"electronic"},{"value":"1538-2931","type":"print"}],"subject":[],"published":{"date-parts":[[2026,3,17]]},"assertion":[{"value":"2025-09-02","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-02-13","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}