{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,6]],"date-time":"2026-06-06T02:19:47Z","timestamp":1780712387249,"version":"3.54.1"},"reference-count":30,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec><jats:title>Background<\/jats:title><jats:p>Femoral stems with bimodular (head-neck as well as neck-body) junctions were designed to help surgeons address patients\u2019 hip anatomy individually. However, arthroplasty registers have reported higher revision rates in stems with bimodular junctions than in stems with modularity limited to the head-neck trunnion. However, to our knowledge, no epidemiologic study has identified patient-specific risk factors for modular femoral neck fractures, and some stems using these designs still are produced and marketed.<\/jats:p><\/jats:sec><jats:sec><jats:title>Questions\/purposes<\/jats:title><jats:p>The purposes of this study were (1) to establish the survival rate free from aseptic loosening of one widely used bimodular THA design; (2) to define the proportion of patients who experienced a fracture of the stem\u2019s modular femoral neck; and (3) to determine factors associated with neck fracture.<\/jats:p><\/jats:sec><jats:sec><jats:title>Methods<\/jats:title><jats:p>In this retrospective, nationwide, multicenter study, we reviewed 2767 bimodular Profemur\u00ae Z stems from four hospitals in Slovenia with a mean followup of 8 years (range, 3 days to 15 years). Between 2002 and 2015, the four participating hospitals performed 26,132 primary THAs; this implant was used in 2767 of them (11%). The general indications for using this implant were primary osteoarthritis (OA) in 2198 (79%) hips and other indications in 569 (21%) hips. We followed patients from the date of the index operation to the date of death, date of revision, or the end of followup on March 1, 2018. We believe that all revisions would be captured in our sample, except for patients who may have emigrated outside the country, but the proportion of people immigrating to Slovenia is higher than the proportion of those emigrating from it; however, no formal accounting for loss to followup is possible in a study of this design. There were 1438 (52%) stems implanted in female and 1329 (48%) in male patients, respectively. A titanium alloy neck was used in 2489 hips (90%) and a cobalt-chromium neck in 278 (10%) hips. The mean body mass index (BMI) at the time of operation was 29 kg\/m<jats:sup>2<\/jats:sup>(SD \u00b1 5 kg\/m<jats:sup>2<\/jats:sup>). We used Kaplan-Meier analysis to establish survival rates, and we performed a chart review to determine the proportion of patients who experienced femoral neck fractures. A binary logistic regression model that controlled for the potential confounding variables of age, sex, BMI, time since implantation, type of bearing, diagnosis, hospital, neck length, and neck material was used to analyze neck fractures.<\/jats:p><\/jats:sec><jats:sec><jats:title>Results<\/jats:title><jats:p>There were 55 (2%) aseptic stem revisions. Survival rate free from aseptic loosening at 12 years was 97% (95% confidence interval [CI] \u00b1 1%). Fracture of the modular neck occurred in 23 patients (0.83%) with a mean BMI of 29 kg\/m<jats:sup>2<\/jats:sup>(SD \u00b1 4 kg\/m<jats:sup>2<\/jats:sup>.) Twenty patients with neck fractures were males and 19 of 23 fractured necks were long. Time since implantation (odds ratio [OR], 0.55; 95% CI 0.46-0.66; p &lt; 0.001), a long neck (OR, 6.77; 95% CI, 2.1-22.2; p = 0.002), a cobalt-chromium alloy neck (OR, 5.7; 95% CI, 1.6-21.1; p = 0.008), younger age (OR, 0.91; 95% CI, 0.86-0.96; p &lt; 0.001), and male sex (OR, 3.98; 95% CI, 1.04-14.55; p = 0.043) were factors associated with neck fracture.<\/jats:p><\/jats:sec><jats:sec><jats:title>Conclusions<\/jats:title><jats:p>The loosening and neck fracture rates of the Profemur\u00ae Z stem were lower than in some of previously published series. However, the use of modular femoral necks in primary THA increases the risk for neck fracture, particularly in young male patients with cobalt-chromium long femoral necks. The bimodular stem we analyzed fractured unacceptably often, especially in younger male patients. For most patients, the risks of using this device outweigh the benefits, and several dozen patients had revisions and complications they would not have had if a different stem had been used.<\/jats:p><\/jats:sec><jats:sec><jats:title>Level of Evidence<\/jats:title><jats:p>Level III, therapeutic study.<\/jats:p><\/jats:sec>","DOI":"10.1097\/corr.0000000000000646","type":"journal-article","created":{"date-parts":[[2019,3,2]],"date-time":"2019-03-02T02:29:22Z","timestamp":1551493762000},"page":"1324-1332","source":"Crossref","is-referenced-by-count":20,"title":["What Factors Are Associated With Neck Fracture in One Commonly Used Bimodular THA Design? A Multicenter, Nationwide Study in Slovenia"],"prefix":"10.1097","volume":"477","author":[{"given":"Simon","family":"Kova\u010d","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bla\u017e","family":"Mav\u010di\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marko","family":"Kotnik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vesna","family":"Leva\u0161i\u010d","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mateja","family":"Sir\u0161e","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Samo Karel","family":"Fokter","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,2,6]]},"reference":[{"key":"R1-20230814","doi-asserted-by":"crossref","first-page":"2023","DOI":"10.1002\/jor.23481","article-title":"Effects of hip implant modular neck material and assembly method on fatigue life and distraction force: amterial and assembly effects on modular necks","volume":"35","author":"Aljenaei","year":"2017","journal-title":"J Orthop Res"},{"key":"R2-20230814","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1007\/s11999-010-1678-9","article-title":"A Comparison of two implant systems in restoration of hip geometry in arthroplasty","volume":"469","author":"Archibeck","year":"2011","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20230814","doi-asserted-by":"crossref","first-page":"1522","DOI":"10.2106\/JBJS.I.00980","article-title":"Corrosion-induced fracture of a double-modular hip prosthesis: a case report","volume":"92","author":"Atwood","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R5-20230814","doi-asserted-by":"crossref","first-page":"2046","DOI":"10.1007\/s11999-017-5260-6","article-title":"Exchangeable femoral neck (dual-modular) THA prostheses have poorer survivorship than other designs: a nationwide cohort of 324,108 patients","volume":"475","author":"Colas","year":"2017","journal-title":"Clin Orthop Relat Res"},{"key":"R6-20230814","doi-asserted-by":"crossref","first-page":"395","DOI":"10.21037\/atm.2017.07.36","article-title":"Midterm outcomes of titanium modular femoral necks in total hip arthroplasty","volume":"5","author":"Collet","year":"2017","journal-title":"Ann Transl Med"},{"key":"R7-20230814","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1111\/j.2517-6161.1972.tb00899.x","article-title":"Regression models in life-tables","volume":"34","author":"Cox","year":"1972","journal-title":"J Roy Statist Soc Series"},{"key":"R8-20230814","doi-asserted-by":"crossref","DOI":"10.1007\/s11249-018-1069-z","article-title":"Influence of calf serum on fretting behaviors of Ti\u20136Al\u20134V and diamond-like carbon coating for neck adapter\u2013femoral stem contact","volume":"66","author":"Ding","year":"2018","journal-title":"Tribol Lett"},{"key":"R10-20230814","doi-asserted-by":"crossref","first-page":"1827","DOI":"10.1007\/s00264-015-2894-4","article-title":"Long-term survivorship and complication rate comparison of a cementless modular stem and cementless fixed neck stems for primary total hip replacement","volume":"39","author":"Fitch","year":"2015","journal-title":"Int Orthop"},{"key":"R11-20230814","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1016\/j.ijfatigue.2009.09.009","article-title":"Corrosion, fatigue and corrosion fatigue behaviour of metal implant materials, especially titanium alloys","volume":"32","author":"Fleck","year":"2010","journal-title":"Int J Fatigue"},{"key":"R12-20230814","first-page":"115","article-title":"The innovation trap: modular neck in total hip arthroplasty","volume":"86","author":"Fokter","year":"2017","journal-title":"Zdrav Vestn"},{"key":"R13-20230814","first-page":"197","article-title":"Titanium alloy femoral neck fracture\u2014clinical and metallurgical analysis in 6 cases","volume":"87","author":"Fokter","year":"2016","journal-title":"Acta Orthop"},{"key":"R14-20230814","doi-asserted-by":"crossref","first-page":"2450","DOI":"10.1016\/j.arth.2017.03.025","article-title":"A single-center experience with a titanium modular neck total hip arthroplasty","volume":"32","author":"Gofton","year":"2017","journal-title":"J Arthroplasty"},{"key":"R15-20230814","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/1471-2474-11-3","article-title":"Modular titanium alloy neck adapter failures in hip replacement-failure mode analysis and influence of implant material","volume":"11","author":"Grupp","year":"2010","journal-title":"BMC Musculoskelet Disord"},{"key":"R16-20230814","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1080\/01621459.1958.10501452","article-title":"Nonparametric estimation from incomplete observations","volume":"53","author":"Kaplan","year":"1958","journal-title":"J Am Stat Assoc"},{"key":"R17-20230814","doi-asserted-by":"crossref","first-page":"400","DOI":"10.1016\/j.electacta.2012.12.029","article-title":"Role of plastic deformation and microstructure in the micro-electrochemical behaviour of Ti\u20136Al\u20134V in sodium chloride solution","volume":"104","author":"Krawiec","year":"2013","journal-title":"Electrochim Acta"},{"key":"R18-20230814","first-page":"71","article-title":"Arthroplasty register of the Valdoltra Orthopaedic Hospital and implant retrieval program","volume":"78","author":"Leva\u0161i\u010d","year":"2009","journal-title":"Zdrav Vestn"},{"key":"R19-20230814","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/S0883-5403(00)91337-8","article-title":"The anatomic basis for the concept of lateralized femoral stems: a frontal plane radiographic study of the proximal femur","volume":"15","author":"Massin","year":"2000","journal-title":"J Arthroplasty"},{"key":"R20-20230814","doi-asserted-by":"crossref","first-page":"3342","DOI":"10.1007\/s11999-010-1385-6","article-title":"Modular necks improve the range of hip motion in cases with excessively anteverted or retroverted femurs in THA","volume":"468","author":"Matsushita","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"R21-20230814","first-page":"49","article-title":"Modular necks and corrosion - review of five cases","volume":"6","author":"McTighe","year":"2016","journal-title":"Reconstr Rev"},{"key":"R22-20230814","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/j.otsr.2014.03.027","article-title":"Fracture of the cobalt-chromium modular femoral neck component in total hip arthroplasty","volume":"100","author":"Menci\u00e8re","year":"2014","journal-title":"Orthop Traumatol Surg Res"},{"key":"R23-20230814","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1007\/s00590-017-2071-0","article-title":"Cementless modular neck stems: are they a safe option in primary total hip arthroplasty?","volume":"28","author":"Pelayo-de-Tom\u00e1s","year":"2018","journal-title":"Eur J Orthop Surg Traumatol"},{"key":"R24-20230814","doi-asserted-by":"crossref","first-page":"185","DOI":"10.2307\/2344317","article-title":"Asymptotically efficient rank invariant test procedures","volume":"135","author":"Peto","year":"1972","journal-title":"J R Statist Soc A"},{"key":"R25-20230814","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1007\/s11999-015-4542-0","article-title":"High risk of failure with bimodular femoral components in THA","volume":"474","author":"Pour","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"R26-20230814","doi-asserted-by":"crossref","first-page":"1768","DOI":"10.1016\/j.arth.2014.04.039","article-title":"Midterm results of a femoral stem with a modular neck design: clinical outcomes and metal ion analysis","volume":"29","author":"Silverton","year":"2014","journal-title":"J Arthroplasty"},{"key":"R28-20230814","doi-asserted-by":"crossref","first-page":"8","DOI":"10.5301\/hipint.5000429","article-title":"3rd generation alumina-on-alumina in modular hip prosthesis: 13 to 18 years follow-up results","volume":"27","author":"Toni","year":"2017","journal-title":"Hip Int"},{"key":"R29-20230814","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1007\/s00776-010-0018-y","article-title":"Modular neck prostheses in DDH patients: 11-year results","volume":"16","author":"Traina","year":"2011","journal-title":"J Orthop Sci"},{"key":"R30-20230814","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1007\/s11517-014-1171-9","article-title":"Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty","volume":"52","author":"Turley","year":"2014","journal-title":"Med Biol Eng Comput"},{"key":"R31-20230814","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.artd.2016.09.004","article-title":"Early fracture of the modular neck of a MODULUS femoral stem","volume":"3","author":"Uchiyama","year":"2017","journal-title":"Arthroplast Today"},{"key":"R32-20230814","doi-asserted-by":"crossref","first-page":"1514","DOI":"10.2106\/JBJS.I.01107","article-title":"Early failure of a modular femoral neck total hip arthroplasty component: a case report","volume":"92","author":"Wilson","year":"2010","journal-title":"J Bone Joint Surg Am"},{"key":"R33-20230814","doi-asserted-by":"crossref","first-page":"1518","DOI":"10.2106\/JBJS.I.01033","article-title":"Fracture of a modular femoral neck after total hip arthroplasty: a case report","volume":"92","author":"Wright","year":"2010","journal-title":"J Bone Joint Surg Am"}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003086-201906000-00015","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,7,15]],"date-time":"2024-07-15T09:11:47Z","timestamp":1721034707000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003086-201906000-00015"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2,6]]},"references-count":30,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/corr.0000000000000646","relation":{},"ISSN":["0009-921X"],"issn-type":[{"value":"0009-921X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,2,6]]}}}