{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,21]],"date-time":"2026-07-21T00:01:30Z","timestamp":1784592090038,"version":"3.55.0"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2019,6]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Hooded acetabular liners and head sizes \u2265 32 mm have both shown to have a beneficial effect on the revision rate for dislocation in THA. Experience with noncrosslinked polyethylene (nonXLPE) raised concerns regarding the risk of impingement damage, loosening, and osteolysis with hooded liners; however, the evidence for this in crosslinked polyethylene (XLPE) is inconclusive. The interaction between different femoral head sizes and hooded liners is not well understood, and it is unclear whether hooded XLPE liners have a beneficial effect on overall long-term survivorship.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Questions\/purposes<\/jats:title>\n            <jats:p>We analyzed a large national joint registry to ask: (1) Is the use of hooded XLPE liners associated with a reduced revision rate for dislocation compared with nonhooded liners? (2) Is there a difference in the revision rate for aseptic loosening\/osteolysis? (3) Is head size associated with any difference in the revision rate between hooded and nonhooded liners?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>The Australian Orthopaedic Association National Joint Replacement Registry longitudinally maintains data on all primary and revision joint arthroplasties with nearly 100% capture. We analyzed all conventional primary THAs performed from registry inception in September 1999 until December 31, 2016 in patients with a diagnosis of osteoarthritis who had nonhooded or hooded XLPE bearings in a cementless acetabular shell. The study group included 192,659 THA procedures with XLPE liners, of which 67,904 were nonhooded and 124,755 were hooded. The mean age of patients receiving nonhooded liners was 70 years (range, 11-100 years); 44% were males. This was similar to the patients with hooded liners, who had a mean age of 70 years (range, 16-100 years); 45% were males. The main outcome measure was the cumulative percent revision at 15 years of the THA using Kaplan-Meier estimates of survivorship. We examined reasons for revision and and performed multivariable analysis to control for the confounding factors of three head size groups (&lt; 32mm, 32mm, and &gt; 32mm) and for the method of femoral fixation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>There was a higher revision rate for dislocation for patients with nonhooded liners at all times to 15 years (HR, 1.31; 95% CI, 1.17\u20131.47; p &lt; 0.001). There was a higher revision rate for the diagnosis of aseptic loosening\/osteolysis with patients with nonhooded liners compared with hooded liners (HR, 1.19; 95% CI, 1.05\u20131.34; p = 0.006). Head sizes of 32 mm or larger were independently associated with a lower comparative revision rate between hooded and nonhooded liners, but this was not apparent for head sizes smaller than 32 mm. It appeared that the main driver of the finding in larger heads was a reduced dislocation risk with hooded liners for 32 mm heads (HR, 1.50; 95% CI, 1.23\u20131.80; p &lt; 0.001) and for heads larger than 32 mm (HR, 1.50; 95% CI, 1.20\u20131.89; p &lt; 0.001).<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Prior research has suggested that hooded acetabular liners may be associated with impingement, loosening, and osteolysis; however, in this large, registry-based report we found that XLPE hooded liners are not associated with an increased revision rate for aseptic loosening\/osteolysis. Although there are many potential confounding variables in this registry analysis, if anything, surgeons using larger femoral heads and hooded liners likely did so in patients with a higher perceived dislocation risk. Patients with larger heads and XLPE hooded liners were, however, less likely to experience revision for dislocation. These liners therefore appear reasonable to use in primary THA at the surgeon\u2019s discretion.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Level of Evidence<\/jats:title>\n            <jats:p>Level III, therapeutic study.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/corr.0000000000000710","type":"journal-article","created":{"date-parts":[[2019,5,16]],"date-time":"2019-05-16T11:14:54Z","timestamp":1558005294000},"page":"1315-1321","source":"Crossref","is-referenced-by-count":10,"title":["Are Hooded, Crosslinked Polyethylene Liners Associated with a Reduced Risk of Revision After THA?"],"prefix":"10.1097","volume":"477","author":[{"given":"Adrian","family":"Bauze","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Somen","family":"Agrawal","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alana","family":"Cuthbert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Richard","family":"de Steiger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2019,5,15]]},"reference":[{"key":"R1-20230814","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1097\/00003086-197509000-00016","article-title":"Range of motion studies for total hip replacements. A comparative study with a new experimental apparatus","volume":"111","author":"Amstutz","year":"1975","journal-title":"Clin Orthop Relat Res"},{"key":"R3-20230814","doi-asserted-by":"crossref","first-page":"229","DOI":"10.1097\/BLO.0b013e3180986753","article-title":"Competing events influence estimated survival probability: when is Kaplan-Meier analysis appropriate?","volume":"462","author":"Biau","year":"2007","journal-title":"Clin Orthop Relat Res"},{"issue":"11 Suppl A","key":"R4-20230814","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1302\/0301-620X.95B11.32645","article-title":"Dislocation following total hip replacement: causes and cures","volume":"95-B","author":"Brooks","year":"2013","journal-title":"Bone Joint J"},{"key":"R6-20230814","doi-asserted-by":"crossref","first-page":"80","DOI":"10.2106\/00004623-199601000-00011","article-title":"The elevated-rim acetabular liner in total hip arthroplasty: relationship to postoperative dislocation","volume":"78","author":"Cobb","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20230814","first-page":"1585","article-title":"Excessive polyethylene wear and acetabular bone defect from standard use of a hooded acetabular insert in total hip arthroplasty","volume":"38","author":"Davey","year":"2014","journal-title":"Int Orthop"},{"key":"R8-20230814","doi-asserted-by":"crossref","first-page":"158.e15","DOI":"10.1016\/j.arth.2007.12.020","article-title":"Fracture of a cross-linked polyethylene liner due to impingement","volume":"24","author":"Duffy","year":"2009","journal-title":"J Arthroplasty"},{"key":"R9-20230814","doi-asserted-by":"crossref","first-page":"548","DOI":"10.3109\/17453674.2010.524594","article-title":"Competing risks survival analysis applied to data from the Australian Orthopaedic Association National Joint Replacement Registry","volume":"81","author":"Gillam","year":"2010","journal-title":"Acta Orthop"},{"key":"R10-20230814","doi-asserted-by":"crossref","first-page":"3077","DOI":"10.1007\/s11999-012-2330-7","article-title":"Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties","volume":"470","author":"Harris","year":"2012","journal-title":"Clin Orthop Relat Res"},{"key":"R11-20230814","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.arth.2005.04.026","article-title":"Impingement of acetabular cups in a hip simulator: comparison of highly cross-linked and conventional polyethylene","volume":"20","author":"Holley","year":"2005","journal-title":"J Arthroplasty"},{"key":"R12-20230814","doi-asserted-by":"crossref","first-page":"1095","DOI":"10.2106\/JBJS.K.00570","article-title":"Large femoral heads decrease the incidence of dislocation after total hip arthroplasty: a randomized controlled trial","volume":"94","author":"Howie","year":"2012","journal-title":"J Bone Joint Surg Am"},{"key":"R13-20230814","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1016\/j.arth.2007.05.044","article-title":"Total hip arthroplasty with the Secur-Fit and Secur-Fit plus femoral stem design a brief follow-up report at 5 to 10 years","volume":"23","author":"Incavo","year":"2008","journal-title":"J Arthroplasty"},{"key":"R14-20230814","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1302\/0301-620X.96B7.33658","article-title":"The use of a lipped acetabular liner decreases the rate of revision for instability after total hip replacement: a study using data from the New Zealand Joint Registry","volume":"96-B","author":"Insull","year":"2014","journal-title":"Bone Joint J"},{"key":"R15-20230814","first-page":"466","article-title":"Effect of acetabular cup abduction on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing","volume":"43","author":"Korduba","year":"2014","journal-title":"Am J Orthop (Belle Mead NJ)"},{"key":"R16-20230814","doi-asserted-by":"crossref","first-page":"342","DOI":"10.3109\/17453674.2013.810518","article-title":"Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty: a population-based analysis of 42,379 primary procedures from the Finnish Arthroplasty Register","volume":"84","author":"Kostensalo","year":"2013","journal-title":"Acta Orthop"},{"issue":"Suppl","key":"R17-20230814","doi-asserted-by":"crossref","first-page":"S53","DOI":"10.1016\/S0883-5403(08)80056-3","article-title":"Elevated-rim acetabular components \u2013 Effect on range of motion and stability in total hip arthroplasty","volume":"6","author":"Krushell","year":"1991","journal-title":"J Arthroplasty"},{"key":"R18-20230814","doi-asserted-by":"crossref","first-page":"107","DOI":"10.3109\/17453674.2014.893498","article-title":"Countrywise results of total hip replacement","volume":"85","author":"Makela","year":"2014","journal-title":"Acta Orthopaedica"},{"key":"R19-20230814","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.otsr.2010.12.004","article-title":"Component impingement in total hip arthroplasty: frequency and rsik factors. A continuous retrieval analysis series of 416 cups","volume":"972","author":"Marchetti","year":"2011","journal-title":"Orthop Traumatol Surg Res"},{"issue":"Suppl 10","key":"R20-20230814","doi-asserted-by":"crossref","first-page":"S7","DOI":"10.5301\/hipint.5000164","article-title":"An update on surgical approaches in hip arthroplasty: lateral versus posterior approach","volume":"24","author":"Mukka","year":"2014","journal-title":"Hip Int"},{"key":"R22-20230814","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1007\/s11999-014-3858-5","article-title":"Highly crosslinked polyethylene improves wear but not surface damage in retrieved acetabular liners","volume":"473","author":"Pang","year":"2015","journal-title":"Clin Orthop Rel Res"},{"key":"R23-20230814","doi-asserted-by":"crossref","first-page":"910","DOI":"10.1302\/0301-620X.98B7.37062","article-title":"Functional orientation of the acetabular component in ceramic-on-ceramic total hip arthroplasty and its relevance to squeaking","volume":"98-B","author":"Pierrepont","year":"2016","journal-title":"Bone Joint J"},{"key":"R24-20230814","first-page":"88","article-title":"Effect of elevated-rim acetabular liner and 32-mm femoral head on stability in total hip arthroplasty","volume":"25","author":"Qassem","year":"2004","journal-title":"Saudi Med J"},{"key":"R25-20230814","doi-asserted-by":"crossref","first-page":"2852","DOI":"10.1016\/j.arth.2017.04.037","article-title":"Late dislocations after total hip arthroplasty: Is the bearing a factor?","volume":"32","author":"Shah","year":"2017","journal-title":"J Arthroplasty"},{"key":"R26-20230814","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/j.arth.2004.09.058","article-title":"Impingement in total hip arthroplasty a study of retrieved acetabular components","volume":"20","author":"Shon","year":"2005","journal-title":"J Arthroplasty"},{"key":"R27-20230814","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1054\/arth.2002.30415","article-title":"Independent contribution of elevated-rim acetabular liner and femoral head size to the stability of total hip implants","volume":"17","author":"Sultan","year":"2002","journal-title":"J Arthroplasty"},{"key":"R28-20230814","doi-asserted-by":"crossref","first-page":"2926","DOI":"10.1016\/j.arth.2016.05.049","article-title":"Improved resistance to neck-liner impingement in second generation highly crosslinked polyethylene \u2013 the role of vitame E and crosslinks","volume":"31","author":"Takahashi","year":"2016","journal-title":"J Arthroplasty"},{"key":"R29-20230814","doi-asserted-by":"crossref","first-page":"305","DOI":"10.1016\/S0883-5403(00)90601-6","article-title":"The spatial location of impingement in total hip arthroplasty","volume":"15","author":"Yamaguchi","year":"2000","journal-title":"J Arthroplasty"}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00003086-201906000-00013","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T05:36:13Z","timestamp":1691991373000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003086-201906000-00013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,15]]},"references-count":26,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2019]]}},"URL":"https:\/\/doi.org\/10.1097\/corr.0000000000000710","relation":{},"ISSN":["0009-921X"],"issn-type":[{"value":"0009-921X","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,15]]}}}