{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T15:02:09Z","timestamp":1790694129116,"version":"4.1.0"},"reference-count":45,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2022,2]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Gamma irradiation, which minimizes the risk of infectious disease transmission when human bone allograft is used, has been found to negatively affect its biomechanical properties. However, in those studies, the deep-freezing temperature during irradiation was not necessarily maintained during transportation and sterilization, which may have affected the findings. Prior reports have also suggested that controlled deep freezing may mitigate the detrimental effects of irradiation on the mechanical properties of bone allograft.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Question\/purpose<\/jats:title>\n            <jats:p>Does a controlled deep-freezing temperature during irradiation help preserve the compressive mechanical properties of human femoral cortical bone allografts?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Cortical bone cube samples, each measuring 64 mm<jats:sup>3<\/jats:sup>, were cut from the mid-diaphyseal midshaft of five fresh-frozen cadaver femurs (four male donors, mean [range] age at procurement 42 years [42 to 43]) and were allocated via block randomization into one of three experimental groups (with equal numbers of samples from each donor allocated into each group). Each experimental group consisted of 20 bone cube samples. Samples irradiated in dry ice were subjected to irradiation doses ranging from 26.7 kGy to 27.1 kGy (mean 26.9 kGy) at a deep-freezing temperature below -40\u00b0C (the recommended long-term storage temperature for allografts). Samples irradiated in gel ice underwent irradiation doses ranging from 26.2 kGy and 26.4 kGy (mean 26.3 kGy) in a freezing temperature range between -40\u00b0C and 0\u00b0C. Acting as controls, samples in a third group were not subjected to gamma irradiation. The mechanical properties (0.2% offset yield stress, ultimate compression stress, toughness, and the Young modulus) of samples from each group were subsequently evaluated via axial compression loading to failure along the long axis of the bone. The investigators were blinded to sample group during compression testing.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The mean ultimate compression stress (84 \u00b1 27 MPa versus 119 \u00b1 31 MPa, mean difference 35 [95% CI 9 to 60]; p = 0.005) and toughness (3622 \u00b1 1720 kJ\/m<jats:sup>3<\/jats:sup> versus 5854 \u00b1 2900 kJ\/m<jats:sup>3<\/jats:sup>, mean difference 2232 [95% CI 70 to 4394]; p = 0.009) of samples irradiated at a higher temperature range (-40\u00b0C to 0\u00b0C) were lower than in those irradiated at deep-freezing temperatures (below -40\u00b0C). The mean 0.2% offset yield stress (73 \u00b1 28 MPa versus 109 \u00b1 38 MPa, mean difference 36 [95% CI 11 to 60]; p = 0.002) and ultimate compression stress (84 \u00b1 27 MPa versus 128 \u00b1 40 MPa, mean difference 44 [95% CI 17 to 69]; p &lt; 0.001) of samples irradiated at a higher temperature range (-40\u00b0C to 0\u00b0C) were lower than the nonirradiated control group samples. The mean 0.2% offset yield stress (73 \u00b1 28 MPa versus 101 \u00b1 28 MPa, mean difference 28 [95% CI 3 to 52]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40\u00b0C to 0\u00b0C) were no different with the numbers available to those irradiated at deep-freezing temperature. The mean toughness (3622 \u00b1 1720 kJ\/m<jats:sup>3<\/jats:sup> versus 6231 \u00b1 3410 kJ\/m<jats:sup>3<\/jats:sup>, mean difference 2609 [95% CI 447 to 4771]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40\u00b0C to 0\u00b0C) were no different with the numbers available to the non-irradiated control group samples. The mean 0.2% offset yield stress, ultimate compression stress, and toughness of samples irradiated in deep-freezing temperatures (below -40\u00b0C) were not different with the numbers available to the non-irradiated control group samples. The Young modulus was not different with the numbers available among the three groups.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusion<\/jats:title>\n            <jats:p>In this study, maintenance of a deep-freezing temperature below -40\u00b0C, using dry ice as a cooling agent, consistently mitigated the adverse effects of irradiation on the monotonic-compression mechanical properties of human cortical bone tissue. Preserving the mechanical properties of a cortical allograft, when irradiated in a deep-freezing temperature, may have resulted from attenuation of the deleterious, indirect effects of gamma radiation on its collagen architecture in a frozen state. Immobilization of water molecules in this state prevents radiolysis and the subsequent generation of free radicals. This hypothesis was supported by an apparent loss of the protective effect when a range of higher freezing temperatures was used during irradiation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Clinical Relevance<\/jats:title>\n            <jats:p>Deep-freezing temperatures below -40\u00b0C during gamma irradiation may be a promising approach to better retain the native mechanical properties of cortical bone allografts. A further study of the effect of deep-freezing during gamma radiation sterilization on sterility and other important biomechanical properties of cortical bone (such as, tensile strength, fracture toughness, and fatigue) is needed to confirm these findings.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/corr.0000000000001968","type":"journal-article","created":{"date-parts":[[2021,9,7]],"date-time":"2021-09-07T16:00:10Z","timestamp":1631030410000},"page":"407-418","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":9,"title":["Deep-Freezing Temperatures During Irradiation Preserves the Compressive Strength of Human Cortical Bone Allografts: A Cadaver Study"],"prefix":"10.1097","volume":"480","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6748-268X","authenticated-orcid":false,"given":"Tan Chern","family":"Yang Harmony","sequence":"first","affiliation":[{"name":"Ministry of Health Malaysia, Federal Government Administrative Centre, Putrajaya, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Norimah","family":"Yusof","sequence":"additional","affiliation":[{"name":"Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia"},{"name":"Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia"},{"name":"Jalan Universiti, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Saravana","family":"Ramalingam","sequence":"additional","affiliation":[{"name":"Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia"},{"name":"Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia"},{"name":"Jalan Universiti, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ruzalina","family":"Baharin","sequence":"additional","affiliation":[{"name":"Malaysian Nuclear Agency, Bangi Selangor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ardiyansyah","family":"Syahrom","sequence":"additional","affiliation":[{"name":"Medical Device Technology Center, Institute of Human Centered Engineering, Skudai Johor, Malaysia"},{"name":"Faculty of Engineering, Universiti Teknologi Malaysia, Skudai Johor, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Azura","family":"Mansor","sequence":"additional","affiliation":[{"name":"Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia"},{"name":"Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia"},{"name":"Jalan Universiti, Kuala Lumpur, Malaysia"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2021,9,6]]},"reference":[{"key":"R1-20250505","doi-asserted-by":"crossref","first-page":"927","DOI":"10.1016\/S0736-0266(01)00004-3","article-title":"Fracture resistance of gamma radiation sterilized cortical bone allografts","volume":"19","author":"Akkus","year":"2001","journal-title":"J Orthop Res"},{"key":"R2-20250505","doi-asserted-by":"crossref","first-page":"747","DOI":"10.2106\/00004623-199274050-00014","article-title":"Compressive mechanical properties of human cancellous bone after gamma irradiation","volume":"74","author":"Anderson","year":"1992","journal-title":"J Bone Joint Surg Am"},{"key":"R3-20250505","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s10561-008-9069-0","article-title":"Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts","volume":"9","author":"Balsly","year":"2008","journal-title":"Cell Tissue Bank"},{"key":"R4-20250505","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0021-9290(03)00257-4","article-title":"Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue","volume":"37","author":"Bayraktar","year":"2004","journal-title":"J Biomech"},{"key":"R5-20250505","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1016\/S0030-5898(05)70110-3","article-title":"Allograft bone","volume":"30","author":"Boyce","year":"1999","journal-title":"Orthop Clin North Am"},{"key":"R6-20250505","doi-asserted-by":"crossref","first-page":"532","DOI":"10.1302\/0301-620X.48B3.532","article-title":"Studies in the transplantation of bone","volume":"48","author":"Burwell","year":"1966","journal-title":"J Bone Joint Surg Am"},{"key":"R7-20250505","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1002\/jbm.820240505","article-title":"The effect of \u03b3\u2010irradiation on collagen molecules, isolated \u03b1\u2010chains, and crosslinked native fibers","volume":"24","author":"Cheung","year":"1990","journal-title":"J Biomed Mater Res"},{"key":"R8-20250505","doi-asserted-by":"crossref","first-page":"426","DOI":"10.1002\/jor.1100180314","article-title":"Effect of freeze\u2010drying and gamma irradiation on the mechanical properties of human cancellous bone","volume":"18","author":"Cornu","year":"2000","journal-title":"J Orthop Res"},{"key":"R9-20250505","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1002\/jor.1100150116","article-title":"Effects of ionizing radiation on the mechanical properties of human bone","volume":"15","author":"Currey","year":"1997","journal-title":"J Orthop Res"},{"key":"R10-20250505","first-page":"174","article-title":"Sterilization by gamma irradiation","author":"da Silva Aquino","year":"2012","journal-title":"Intech Open"},{"key":"R12-20250505","first-page":"46","article-title":"Infection of massive bone allografts","volume":"306","author":"Dick","year":"1994","journal-title":"Clin Orthop Relat Res"},{"key":"R13-20250505","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1007\/s10561-005-0338-x","article-title":"Irradiation as a safety procedure in tissue banking","volume":"6","author":"Dziedzic-Goclawska","year":"2005","journal-title":"Cell Tissue Bank"},{"key":"R14-20250505","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.2106\/00004623-199407000-00011","article-title":"Effects of gamma irradiation on the human immunodeficiency virus. A study in frozen human bone-patellar ligament-bone grafts obtained from infected cadavera","volume":"76","author":"Fideler","year":"1994","journal-title":"J Bone Joint Surg Am"},{"key":"R15-20250505","first-page":"307","article-title":"Towards microbiological quality assurance in radiation sterilization processing: simulation of the radiation inactivation process","volume":"58","author":"Fitch","year":"1985","journal-title":"J Appl Microbiol"},{"key":"R16-20250505","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1159\/000335647","article-title":"Effect of storage temperature on allograft bone","volume":"39","author":"F\u00f6lsch","year":"2011","journal-title":"Transfus Med Hemother"},{"key":"R17-20250505","doi-asserted-by":"crossref","first-page":"2033","DOI":"10.1016\/j.biomaterials.2004.06.028","article-title":"Effective use of optimized, high-dose (50kGy) gamma irradiation for pathogen inactivation of human bone allografts","volume":"26","author":"Grieb","year":"2005","journal-title":"Biomaterials"},{"key":"R18-20250505","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1302\/0301-620X.81B2.0810342","article-title":"Changes in allograft bone irradiated at different temperatures","volume":"81","author":"Hamer","year":"1999","journal-title":"J Bone Joint Surg Am"},{"key":"R19-20250505","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1302\/0301-620X.78B3.0780363","article-title":"Biomechanical properties of cortical allograft bone using a new method of bone strength measurement","volume":"78","author":"Hamer","year":"1996","journal-title":"J Bone Joint Surg Am"},{"key":"R20-20250505","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1007\/s11999-015-4589-y","article-title":"Gamma radiation sterilization reduces the high-cycle fatigue life of allograft bone","volume":"474","author":"Islam","year":"2016","journal-title":"Clin Orthop Relat Res"},{"key":"R21-20250505","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1007\/s10561-012-9308-2","article-title":"Effect of gamma irradiation on mechanical properties of human cortical bone: influence of different processing methods","volume":"13","author":"Kaminski","year":"2012","journal-title":"Cell Tissue Bank"},{"key":"R23-20250505","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1002\/jor.1100150115","article-title":"Systematic and random errors in compression testing of trabecular bone","volume":"15","author":"Keaveny","year":"1997","journal-title":"J Orthop Res"},{"key":"R24-20250505","doi-asserted-by":"crossref","first-page":"13297","DOI":"10.1016\/S0021-9258(18)33445-8","article-title":"The influence of low temperature on the radiation sensitivity of enzymes","volume":"257","author":"Kempner","year":"1982","journal-title":"J Biol Chem"},{"key":"R25-20250505","doi-asserted-by":"crossref","first-page":"568","DOI":"10.1002\/jps.2600600411","article-title":"Toxicity of ethylene chlorohydrin I: acute toxicity studies","volume":"60","author":"Lawrence","year":"1971","journal-title":"J Pharm Sci"},{"key":"R26-20250505","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1007\/s11999-013-3397-5","article-title":"Fairness to all: gender and sex in scientific reporting","volume":"472","author":"Leopold","year":"2014","journal-title":"Clin Orthop Relat Res"},{"key":"R27-20250505","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1097\/00003086-200006000-00026","article-title":"Complications of irradiated allografts in orthopaedic tumor surgery","volume":"375","author":"Lietman","year":"2000","journal-title":"Clin Orthop Relat Res"},{"key":"R28-20250505","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/BF00178752","article-title":"Bone allografts sterilised by irradiation","volume":"14","author":"Loty","year":"1990","journal-title":"Int Orthop"},{"key":"R29-20250505","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1097\/01.blo.0000150371.77314.52","article-title":"Infection in massive bone allografts","volume":"432","author":"Mankin","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"R30-20250505","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/j.msec.2005.01.017","article-title":"Viscoelastic properties of bone: mechanical spectroscopy studies on a chicken model","volume":"25","author":"Mano","year":"2005","journal-title":"Mater Sc Eng C"},{"key":"R31-20250505","doi-asserted-by":"crossref","first-page":"2648","DOI":"10.2106\/00004623-200412000-00010","article-title":"The effect of gamma radiation sterilization on the fatigue crack propagation resistance of human cortical bone","volume":"86","author":"Mitchell","year":"2004","journal-title":"J Bone Joint Surg Am"},{"key":"R32-20250505","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/S0021-9290(01)00011-2","article-title":"Dependence of yield strain of human trabecular bone on anatomic site","volume":"34","author":"Morgan","year":"2001","journal-title":"J Biomech"},{"key":"R34-20250505","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1007\/s10561-006-9020-1","article-title":"Sterilization of allograft bone: effects of gamma irradiation on allograft biology and biomechanics","volume":"8","author":"Nguyen","year":"2007","journal-title":"Cell Tissue Bank"},{"key":"R35-20250505","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/j.bone.2011.06.035","article-title":"Compressive behaviour of child and adult cortical bone","volume":"49","author":"\u00d6hman","year":"2011","journal-title":"Bone"},{"key":"R36-20250505","doi-asserted-by":"crossref","first-page":"333","DOI":"10.3109\/17453679609002326","article-title":"High complication rates with pelvic allografts: experience of 22 sarcoma resections","volume":"67","author":"Ozaki","year":"1996","journal-title":"Acta Orthop Scand"},{"key":"R38-20250505","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1227\/00006123-198005000-00006","article-title":"Ethylene oxide sterilization of bone, dura mater, and fascia lata for human transplantation","volume":"6","author":"Prolo","year":"1980","journal-title":"Neurosurgery"},{"key":"R39-20250505","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1006\/biol.2002.0326","article-title":"Effect of gamma irradiation on human cortical bone transplants contaminated with enveloped and non-enveloped viruses","volume":"30","author":"Pruss","year":"2002","journal-title":"Biologicals"},{"key":"R40-20250505","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/2309499018770906","article-title":"Performance of cooling materials and their composites in maintaining freezing temperature during irradiation and transportation of bone allografts","volume":"26","author":"Ramalingam","year":"2018","journal-title":"J Orthop Surg"},{"key":"R41-20250505","doi-asserted-by":"crossref","first-page":"1215","DOI":"10.1002\/jor.21121","article-title":"Impact of freezing on immunology and incorporation of bone allograft","volume":"28","author":"Reiker\u00e5s","year":"2010","journal-title":"J Orthop Res"},{"key":"R42-20250505","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1002\/jor.1100130614","article-title":"Dose\u2010dependent response of gamma irradiation on mechanical properties and related biochemical composition of goat bone\u2010patellar tendon\u2010bone allografts","volume":"13","author":"Salehpour","year":"1995","journal-title":"J Orthop Res"},{"key":"R43-20250505","doi-asserted-by":"crossref","first-page":"355","DOI":"10.4329\/wjr.v8.i4.355","article-title":"Radiation sterilization of tissue allografts: a review","volume":"8","author":"Singh","year":"2016","journal-title":"World J Radiol"},{"key":"R44-20250505","doi-asserted-by":"crossref","first-page":"244","DOI":"10.2106\/00004623-198163020-00010","article-title":"A study of the clinical incidence of infection in the use of banked allograft bone","volume":"63","author":"Tomford","year":"1981","journal-title":"J Bone Joint Surg Am"},{"key":"R45-20250505","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1115\/1.3168375","article-title":"Yield behavior of bovine cancellous bone","volume":"111","author":"Turner","year":"1989","journal-title":"J Biomech Eng"},{"key":"R46-20250505","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/8756-3282(93)90081-K","article-title":"Basic biomechanical measurements of bone: a tutorial","volume":"14","author":"Turner","year":"1993","journal-title":"Bone"},{"key":"R47-20250505","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1002\/1097-4636(2001)58:1<47::AID-JBM70>3.0.CO;2-U","article-title":"The use of dynamic mechanical analysis to assess the viscoelastic properties of human cortical bone","volume":"58","author":"Yamashita","year":"2001","journal-title":"J Biomed Mater Res"},{"key":"R48-20250505","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1007\/s10561-017-9651-4","article-title":"Advances of radiation sterilisation in tissue banking","volume":"19","author":"Yusof","year":"2018","journal-title":"Cell Tissue Bank"},{"key":"R50-20250505","doi-asserted-by":"crossref","first-page":"524","DOI":"10.1302\/2046-3758.78.BJR-2018-0025.R1","article-title":"Standardizing compression testing for measuring the stiffness of human bone","volume":"7","author":"Zhao","year":"2018","journal-title":"Bone Joint Res"}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CORR.0000000000001968","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,5]],"date-time":"2025-05-05T17:15:49Z","timestamp":1746465349000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CORR.0000000000001968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,9,6]]},"references-count":45,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/corr.0000000000001968","relation":{},"ISSN":["0009-921X","1528-1132"],"issn-type":[{"value":"0009-921X","type":"print"},{"value":"1528-1132","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,9,6]]},"assertion":[{"value":"2020-09-15","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-08-16","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}