{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,22]],"date-time":"2026-06-22T11:28:29Z","timestamp":1782127709568,"version":"3.54.5"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"7","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Clin Orthop Relat Res"],"published-print":{"date-parts":[[2022,7]]},"abstract":"<jats:title>Abstract<\/jats:title>\n          <jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>ACL graft-suture fixation can be constructed with needle or needleless techniques. Needleless techniques have the advantage of decreased injury, preparation time, and cost. The Nice knot is common among upper extremity procedures, and has been shown to have higher load to failure and less elongation compared with other double loop knots; however, there are no studies that have looked at its use for ACL graft-suture construct to determine whether it offers less elongation relative to other needleless techniques.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Questions\/purposes<\/jats:title>\n            <jats:p>In a cadaver quadriceps tendon model, we asked: (1) Does the Nice knot have less elongation than the Prusik knot? (2) Does the Nice knot have increased peak load and stiffness compared with the Prusik knot? (3) What were the modes of failure of each knot?<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>Sixteen quadriceps tendon grafts were harvested from 16 cadaver knee specimens. The median (range) age of the donors was 80 years (70 to 96) and included three male and five female donors. Eight grafts were prepared with the Prusik knot and eight with the Nice knot using a braided polyblend suture. The graft-suture constructs were mounted in a materials testing machine and subjected to a tensile loading protocol beginning with pretensioning of three cycles from 0 to 100 N at 1 Hz followed by a constant load of 50 N for 1 minute then cyclic loading of 200 cycles from 50 to 200 N at 1 Hz. The constructs were loaded to failure as the final step of the loading protocol. Elongations of the construct after each loading step, peak load, stiffness, and graft cross-sectional area were compared.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Construct elongations (median [IQR]) for the Nice knot were lower than that of the Prusik knot after pretensioning (4.4 mm [0.8] versus 5.7 mm [1.4]; p = 0.02), preloading (0.6 mm [0.3] versus 1.0 mm [0.3]; p = 0.005), and cyclic loading (7.4 mm [1.4] versus 10.9 mm [2.1]; p = 0.005). Peak load was not different for the Prusik knot construct compared with the Nice knot (334 N [43] versus 312 N [13]; p = 0.08). Stiffness of the Prusik knot construct (103 N\/mm [17]) was no different than the Nice knot construct (110 N\/mm [13]; p = 0.13). Graft cross-sectional area of the Prusik knot constructs (85 mm<jats:sup>2<\/jats:sup> [35]) were similar to the grafts of the Nice knot constructs (97 mm<jats:sup>2<\/jats:sup> [31]; p = 0.28). Failure mode of the constructs did not differ between groups; it was caused by suture rupture near the knots that secured the free suture ends to the machine and was seen in all 16 tests.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>The results of this biomechanical study show that the Nice knot construct has similar or greater biomechanical properties compared with the Prusik knot in the graft suture construct, although the magnitude of the differences are not likely to the level of clinical importance.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Clinical Relevance<\/jats:title>\n            <jats:p>The Nice knot offers an attractive alternative option for needleless ACL graft preparation technique. Future studies should consider comparison to established needle techniques such as Krackow or whipstitch and testing in an intraarticular component in an in vivo model.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/corr.0000000000002153","type":"journal-article","created":{"date-parts":[[2022,3,3]],"date-time":"2022-03-03T17:01:54Z","timestamp":1646326914000},"page":"1403-1410","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["Does the Nice Knot Offer Less Elongation Than the Modified Prusik Knot? An In Vitro Study in Cadaver Quadriceps Tendons"],"prefix":"10.1097","volume":"480","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5272-7410","authenticated-orcid":false,"given":"Shahbaz S.","family":"Malik","sequence":"first","affiliation":[{"name":"Department of Trauma and Orthopaedic Surgery, Worcestershire Acute Hospitals NHS Trust, Worcester, United Kingdom"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Darren","family":"Hart","sequence":"additional","affiliation":[{"name":"Pan Am Clinic Foundation, Winnipeg, Manitoba, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sara","family":"Parashin","sequence":"additional","affiliation":[{"name":"Orthopaedic Innovation Centre, Winnipeg, Manitoba, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jason","family":"Peeler","sequence":"additional","affiliation":[{"name":"Department of Human Anatomy & Cell Science, University of Manitoba, Winnipeg, Manitoba, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sheila","family":"McRae","sequence":"additional","affiliation":[{"name":"Pan Am Clinic Foundation, Winnipeg, Manitoba, Canada"},{"name":"Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"MacDonald","sequence":"additional","affiliation":[{"name":"Pan Am Clinic, Winnipeg, Manitoba, Canada"},{"name":"Department of Surgery, University of Manitoba, Winnipeg, Manitoba, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2022,3,1]]},"reference":[{"key":"R1-20250508","doi-asserted-by":"crossref","first-page":"1163","DOI":"10.1016\/j.arthro.2018.10.140","article-title":"A biomechanical comparison of six suture configurations for soft tissue-based graft traction and fixation","volume":"35","author":"Barber","year":"2019","journal-title":"Arthroscopy"},{"key":"R2-20250508","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0749-8063(99)70038-1","article-title":"Structural properties of sutures used in anchoring multistranded hamstrings in anterior cruciate ligament reconstruction: a biomechanical study","volume":"15","author":"Becker","year":"1999","journal-title":"Arthroscopy"},{"key":"R3-20250508","doi-asserted-by":"crossref","first-page":"e382","DOI":"10.3928\/01477447-20161202-05","article-title":"The doubled-suture Nice knot","volume":"40","author":"Boileau","year":"2017","journal-title":"Orthopedics"},{"key":"R4-20250508","doi-asserted-by":"crossref","first-page":"202","DOI":"10.1016\/S0749-8063(00)90037-9","article-title":"Knot security in simple sliding knots and its relationship to rotator cuff repair: how secure must the knot be?","volume":"16","author":"Burkhart","year":"2000","journal-title":"Arthroscopy"},{"key":"R5-20250508","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1097\/00005373-199904000-00020","article-title":"Arthroscopic anterior cruciate ligament reconstruction with quadriceps tendon-patellar bone autograft","volume":"46","author":"Chen","year":"1999","journal-title":"J Trauma"},{"key":"R6-20250508","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/j.otsr.2016.01.005","article-title":"The Nice knot as an improvement on current knot options: a mechanical analysis","volume":"102","author":"Collin","year":"2016","journal-title":"Orthop Traumatol Surg Res"},{"key":"R7-20250508","doi-asserted-by":"crossref","first-page":"1149","DOI":"10.3758\/BRM.41.4.1149","article-title":"Statistical power analyses using G*Power 3.1: tests for correlation and regression analyses","volume":"41","author":"Faul","year":"2009","journal-title":"Behav Res Methods"},{"key":"R8-20250508","doi-asserted-by":"crossref","first-page":"e93","DOI":"10.1016\/j.asmr.2019.09.001","article-title":"Systematic review of publications regarding quadriceps tendon autograft use in anterior cruciate ligament reconstruction","volume":"1","author":"Heffron","year":"2019","journal-title":"Arthrosc Sports Med Rehabil"},{"key":"R9-20250508","doi-asserted-by":"crossref","first-page":"e321","DOI":"10.1016\/j.eats.2014.01.010","article-title":"Hamstring graft preparation using a modified rolling hitch technique","volume":"3","author":"Hong","year":"2014","journal-title":"Arthrosc Tech"},{"key":"R10-20250508","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1007\/s11999-016-5153-0","article-title":"Do needleless knots have similar strength as the Krackow suture? An in vitro porcine tendon study","volume":"475","author":"Hong","year":"2017","journal-title":"Clin Orthop Relat Res"},{"key":"R11-20250508","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1007\/s00402-017-2830-8","article-title":"Superior biomechanical properties and tying time with the modified Prusik knot and Wittstein suture loop to the Krackow stitch","volume":"138","author":"Hong","year":"2018","journal-title":"Arch Orthop Trauma Surg"},{"key":"R12-20250508","doi-asserted-by":"crossref","first-page":"1151","DOI":"10.1016\/j.arthro.2015.01.011","article-title":"Evaluation of 3 needleless grasping suture techniques for soft-tissue graft fixation: a porcine biomechanical study","volume":"31","author":"Hong","year":"2015","journal-title":"Arthroscopy"},{"key":"R13-20250508","doi-asserted-by":"crossref","first-page":"764","DOI":"10.2106\/00004623-198668050-00020","article-title":"A new stitch for ligament-tendon fixation. Brief note","volume":"68","author":"Krackow","year":"1986","journal-title":"J Bone Joint Surg Am"},{"key":"R14-20250508","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1007\/s00167-006-0176-9","article-title":"Modified Prusik knot versus whipstitch technique for soft tissue fixation in anterior cruciate ligament reconstruction: a biomechanical analysis","volume":"15","author":"Krappinger","year":"2007","journal-title":"Knee Surg Sports Traumatol Arthrosc"},{"key":"R15-20250508","doi-asserted-by":"crossref","first-page":"230949901988830","DOI":"10.1177\/2309499019888307","article-title":"A biomechanical comparison of different tying techniques of a double-stranded looped suture","volume":"27","author":"Luenam","year":"2019","journal-title":"J Orthop Surg"},{"key":"R16-20250508","doi-asserted-by":"crossref","first-page":"3069","DOI":"10.1016\/j.arthro.2019.05.025","article-title":"Soft tissue fixation strategies of human quadriceps tendon grafts: a biomechanical study","volume":"35","author":"Michel","year":"2019","journal-title":"Arthroscopy"},{"key":"R17-20250508","first-page":"84","article-title":"Material properties of common suture materials in orthopaedic surgery","volume":"30","author":"Najibi","year":"2010","journal-title":"Iowa Orthop J"},{"key":"R18-20250508","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1016\/j.csm.2012.08.014","article-title":"Anatomic anterior cruciate ligament reconstruction with quadriceps tendon autograft","volume":"32","author":"Rabuck","year":"2013","journal-title":"Clin Sports Med"},{"key":"R19-20250508","doi-asserted-by":"crossref","first-page":"1641","DOI":"10.1177\/0363546512450406","article-title":"Biomechanical properties of porcine flexor tendon fixation with varying throws and stitch methods","volume":"40","author":"Sakaguchi","year":"2012","journal-title":"Am J Sports Med"},{"key":"R20-20250508","doi-asserted-by":"crossref","first-page":"698","DOI":"10.1136\/bjsports-2017-098769","article-title":"Quadriceps tendon autograft for arthroscopic knee ligament reconstruction: use it now, use it often","volume":"52","author":"Sheean","year":"2018","journal-title":"Br J Sports Med"},{"key":"R21-20250508","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1016\/j.arthro.2014.11.010","article-title":"Quadriceps tendon autograft for anterior cruciate ligament reconstruction: a comprehensive review of current literature and systematic review of clinical results","volume":"31","author":"Slone","year":"2015","journal-title":"Arthroscopy"},{"key":"R22-20250508","doi-asserted-by":"crossref","first-page":"702","DOI":"10.1016\/j.arthro.2011.10.014","article-title":"The modified finger-trap suture technique: a biomechanical comparison of a novel suture technique for graft fixation","volume":"28","author":"Su","year":"2012","journal-title":"Arthroscopy"},{"key":"R23-20250508","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/S0749-8063(98)70022-2","article-title":"The effect of different graft tensioning in anterior cruciate ligament reconstruction: a prospective randomized study","volume":"14","author":"Van Kampen","year":"1998","journal-title":"Arthroscopy"},{"key":"R24-20250508","first-page":"142","article-title":"Hamstring graft preparation using a needleless suture loop","volume":"20","author":"Wittstein","year":"2011","journal-title":"J Surg Orthop Adv"},{"key":"R25-20250508","doi-asserted-by":"crossref","first-page":"1146","DOI":"10.1016\/j.arthro.2006.06.013","article-title":"Mechanical and handling properties of braided polyblend polyethylene sutures in comparison to braided polyester and monofilament polydioxanone sutures","volume":"22","author":"W\u00fcst","year":"2006","journal-title":"Arthroscopy"},{"key":"R26-20250508","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1177\/036354659702500120","article-title":"Effects of initial graft tension on clinical outcome after anterior cruciate ligament reconstruction: autogenous doubled hamstring tendons connected in series with polyester tapes","volume":"25","author":"Yasuda","year":"1997","journal-title":"Am J Sports Med"}],"container-title":["Clinical Orthopaedics &amp; Related Research"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CORR.0000000000002153","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,8]],"date-time":"2025-05-08T15:02:55Z","timestamp":1746716575000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CORR.0000000000002153"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,3,1]]},"references-count":26,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2022]]}},"URL":"https:\/\/doi.org\/10.1097\/corr.0000000000002153","relation":{},"ISSN":["0009-921X","1528-1132"],"issn-type":[{"value":"0009-921X","type":"print"},{"value":"1528-1132","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,3,1]]},"assertion":[{"value":"2021-05-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2022-02-04","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}