{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T11:11:44Z","timestamp":1774869104055,"version":"3.50.1"},"reference-count":56,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2020,11]]},"abstract":"<jats:p>The total artificial heart (TAH) is a device that replaces the failing ventricles. There have been numerous TAHs designed over the last few decades, but the one with the largest patient experience is the SynCardia temporary TAH. The 50-mL and 70-mL sizes have been approved in the United States, Europe, and Canada as a bridge to transplantation. It is indicated in patients with severe biventricular failure or structural heart issues that preclude the use of a left ventricular assist device. The majority of the patients implanted are Interagency Registry for Mechanically Assisted Circulatory Support profile 1 or 2. The 1-year survival in experienced centers that have implanted over 10 TAHs is 73%. The risk factors for death include older age, need for preimplantation dialysis, and malnutrition. The most common causes of death are multiple organ failure, usually the result of physiologic deterioration before implantation, and neurologic dysfunction. The device allows the patient to be discharged home and managed as an outpatient. Proper patient selection, the timing of intervention, patient care, and device management are essential for a suitable outcome. In addition, the CARMAT TAH is another device that will soon be studied in a clinical trial in the United States. The BiVACOR TAH is a revolutionary design utilizing electromagnetic levitation that is expected to enter a clinical trial in the next few years.<\/jats:p>","DOI":"10.1097\/crd.0000000000000322","type":"journal-article","created":{"date-parts":[[2020,6,6]],"date-time":"2020-06-06T02:44:31Z","timestamp":1591411471000},"page":"275-282","source":"Crossref","is-referenced-by-count":17,"title":["The Total Artificial Heart"],"prefix":"10.1097","volume":"28","author":[{"given":"Francisco A.","family":"Arab\u00eda","sequence":"first","affiliation":[{"name":"Surgery"},{"name":"Medicine, Banner-University of Arizona, Phoenix, AZ."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2020,6,1]]},"reference":[{"key":"R1-20230903","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1056\/NEJMoa040186","article-title":"Cardiac replacement with a total artificial heart as a bridge to transplantation.","volume":"351","author":"Copeland","year":"2004","journal-title":"N Engl J Med"},{"key":"R2-20230903","doi-asserted-by":"crossref","first-page":"1304","DOI":"10.1016\/j.healun.2018.04.004","article-title":"Interagency registry for mechanically assisted circulatory support report on the total artificial heart.","volume":"37","author":"Arab\u00eda","year":"2018","journal-title":"J Heart Lung Transplant"},{"key":"R3-20230903","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1038\/clpt.2011.274","article-title":"State-of-the-art implantable cardiac assist device therapy for heart failure: bridge to transplant and destination therapy.","volume":"91","author":"Park","year":"2012","journal-title":"Clin Pharmacol Ther"},{"key":"R4-20230903","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s10741-012-9303-5","article-title":"Mechanical circulatory support: devices, outcomes, and complications.","volume":"18","author":"Milano","year":"2013","journal-title":"Heart Fail Rev"},{"key":"R5-20230903","doi-asserted-by":"crossref","first-page":"566","DOI":"10.1016\/j.jtcvs.2012.10.034","article-title":"Orthotopic heart transplant versus left ventricular assist device: a national comparison of cost and survival.","volume":"145","author":"Mulloy","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R6-20230903","doi-asserted-by":"crossref","first-page":"332","DOI":"10.1111\/j.1525-1594.2011.01366.x","article-title":"Mechanical circulatory support for right heart failure: current technology and future outlook.","volume":"36","author":"Hsu","year":"2012","journal-title":"Artif Organs"},{"key":"R7-20230903","doi-asserted-by":"crossref","first-page":"1316","DOI":"10.1016\/j.jtcvs.2009.11.020","article-title":"Right ventricular failure with the HeartMate II continuous-flow left ventricular assist device: incidence, risk factors, and effect on outcomes.","volume":"139","author":"Kormos","year":"2010","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R8-20230903","doi-asserted-by":"crossref","first-page":"2155","DOI":"10.1016\/j.athoracsur.2013.07.008","article-title":"Survival after left ventricular assist device with and without temporary right ventricular support.","volume":"96","author":"Lazar","year":"2013","journal-title":"Ann Thorac Surg"},{"key":"R9-20230903","doi-asserted-by":"crossref","first-page":"523","DOI":"10.1111\/aor.12038","article-title":"Temporary right ventricular mechanical support in high-risk left ventricular assist device recipients versus permanent biventricular or total artificial heart support.","volume":"37","author":"Loforte","year":"2013","journal-title":"Artif Organs"},{"key":"R10-20230903","doi-asserted-by":"crossref","first-page":"723","DOI":"10.1016\/0002-9149(69)90460-3","article-title":"Orthotopic cardiac prosthesis for two-staged cardiac replacement.","volume":"24","author":"Cooley","year":"1969","journal-title":"Am J Cardiol"},{"key":"R11-20230903","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1038\/nm0103-108","article-title":"The total artificial heart.","volume":"9","author":"Cooley","year":"2003","journal-title":"Nat Med"},{"key":"R12-20230903","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1056\/NEJM198402023100501","article-title":"Clinical use of the total artificial heart.","volume":"310","author":"DeVries","year":"1984","journal-title":"N Engl J Med"},{"key":"R13-20230903","first-page":"251","article-title":"Chronic nonpulsatile blood flow in an alive, awake animal 34-day survival.","volume":"26","author":"Golding","year":"1980","journal-title":"Trans Am Soc Artif Intern Organs"},{"key":"R14-20230903","first-page":"81","article-title":"Chronic nonpulsatile blood flow.","volume":"28","author":"Golding","year":"1982","journal-title":"Trans Am Soc Artif Intern Organs"},{"key":"R15-20230903","first-page":"520","article-title":"Physiopathological studies of nonpulsatile blood flow in chronic models.","volume":"29","author":"Yada","year":"1983","journal-title":"Trans Am Soc Artif Intern Organs"},{"issue":"1 pt 1","key":"R16-20230903","first-page":"103","article-title":"Summary of the clinical use of the Symbion total artificial heart: a registry report.","volume":"11","author":"Johnson","year":"1992","journal-title":"J Heart Lung Transplant"},{"key":"R17-20230903","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/j.jtcvs.2011.12.002","article-title":"Experience with more than 100 total artificial heart implants.","volume":"143","author":"Copeland","year":"2012","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R18-20230903","first-page":"493","article-title":"Bridge to transplantation using paracorporeal biventricular assist devices or the syncardia temporary total artificial heart: is there a difference?.","volume":"56","author":"Nguyen","year":"2015","journal-title":"J Cardiovasc Surg (Torino)"},{"key":"R19-20230903","doi-asserted-by":"crossref","first-page":"S134","DOI":"10.1016\/j.healun.2012.01.386","article-title":"Survival to transplant in patients undergoing mechanical circulatory support as bridge:retrospective analysis of LVAD, BiVAD and TAH strategy.","volume":"31","author":"Pajaro","year":"2012","journal-title":"J. Heart Lung Transplant"},{"key":"R20-20230903","doi-asserted-by":"crossref","first-page":"39","DOI":"10.15420\/usc.2011.8.1.39","article-title":"The SynCardia temporary total artificial heart \u2013 evolving clinical role and future status.","volume":"8","author":"Slepian","year":"2011","journal-title":"US Cardiol"},{"key":"R21-20230903","first-page":"703","article-title":"Nine year experience with the clinical use of total artificial hearts as cardiac support devices.","volume":"34","author":"Joyce","year":"1988","journal-title":"ASAIO Trans"},{"issue":"suppl","key":"R22-20230903","doi-asserted-by":"crossref","first-page":"S5","DOI":"10.1016\/S1010-7940(97)01183-4","article-title":"International experience with the CardioWest total artificial heart as a bridge to heart transplantation.","volume":"11","author":"Arabia","year":"1997","journal-title":"Eur J Cardiothorac Surg"},{"key":"R23-20230903","doi-asserted-by":"crossref","first-page":"204","DOI":"10.1046\/j.1525-1594.1999.06270.x","article-title":"CardioWest total artificial heart: a retrospective controlled study.","volume":"23","author":"Arabia","year":"1999","journal-title":"Artif Organs"},{"key":"R24-20230903","doi-asserted-by":"crossref","first-page":"1662","DOI":"10.1016\/S0003-4975(98)00896-0","article-title":"The CardioWest total artificial heart bridge to transplantation: 1993 to 1996 national trial.","volume":"66","author":"Copeland","year":"1998","journal-title":"Ann Thorac Surg"},{"key":"R25-20230903","doi-asserted-by":"crossref","first-page":"823","DOI":"10.1016\/j.healun.2003.07.024","article-title":"Total artificial heart bridge to transplantation: a 9-year experience with 62 patients.","volume":"23","author":"Copeland","year":"2004","journal-title":"J Heart Lung Transplant"},{"key":"R26-20230903","doi-asserted-by":"crossref","first-page":"1296","DOI":"10.1016\/S1053-2498(03)00036-6","article-title":"Bridge to transplantation with the Jarvik-7 (CardioWest) total artificial heart: a single-center 15-year experience.","volume":"22","author":"Leprince","year":"2003","journal-title":"J Heart Lung Transplant"},{"key":"R27-20230903","doi-asserted-by":"crossref","first-page":"548","DOI":"10.1016\/j.athoracsur.2005.02.084","article-title":"CardioWest total artificial heart: bad oeynhausen experience.","volume":"80","author":"El-Banayosy","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"R28-20230903","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.athoracsur.2016.01.019","article-title":"Outcomes in patients bridged with univentricular and biventricular devices in the modern era of heart transplantation.","volume":"102","author":"Grimm","year":"2016","journal-title":"Ann Thorac Surg"},{"key":"R29-20230903","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1016\/j.healun.2012.12.004","article-title":"Fifth INTERMACS annual report: risk factor analysis from more than 6,000 mechanical circulatory support patients.","volume":"32","author":"Kirklin","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R30-20230903","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1097\/MAT.0b013e3182816cb7","article-title":"Changes in the functional status measures of heart failure patients with mechanical assist devices.","volume":"59","author":"Leibner","year":"2013","journal-title":"ASAIO J"},{"key":"R31-20230903","doi-asserted-by":"crossref","first-page":"578","DOI":"10.1016\/j.healun.2016.01.1227","article-title":"Outcomes of children implanted with ventricular assist devices in the United States: first analysis of the Pediatric Interagency Registry for Mechanical Circulatory Support (PediMACS).","volume":"35","author":"Blume","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"R32-20230903","doi-asserted-by":"crossref","first-page":"1490","DOI":"10.1016\/j.athoracsur.2004.04.094","article-title":"CardioWest total artificial heart in a moribund adolescent with left ventricular thrombi.","volume":"80","author":"Smith","year":"2005","journal-title":"Ann Thorac Surg"},{"key":"R33-20230903","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1177\/0267659113496580","article-title":"Total artificial heart in the pediatric patient with biventricular heart failure.","volume":"29","author":"Park","year":"2014","journal-title":"Perfusion"},{"key":"R34-20230903","doi-asserted-by":"crossref","first-page":"1249","DOI":"10.1016\/j.healun.2013.09.005","article-title":"Pre-operative health status and outcomes after continuous-flow left ventricular assist device implantation.","volume":"32","author":"Flint","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R35-20230903","doi-asserted-by":"crossref","first-page":"535","DOI":"10.1016\/j.healun.2009.02.015","article-title":"INTERMACS profiles of advanced heart failure: the current picture.","volume":"28","author":"Stevenson","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R36-20230903","doi-asserted-by":"crossref","first-page":"E348","DOI":"10.1111\/ctr.12146","article-title":"Role of the total artificial heart in the management of heart transplant rejection and retransplantation: case report and review.","volume":"27","author":"Kalya","year":"2013","journal-title":"Clin Transplant"},{"key":"R37-20230903","doi-asserted-by":"crossref","first-page":"1167","DOI":"10.1253\/circj.CJ-08-0483","article-title":"The CardioWest total artificial heart for chronic heart transplant rejection.","volume":"73","author":"Yoda","year":"2009","journal-title":"Circ J"},{"key":"R38-20230903","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1053\/j.semtcvs.2012.04.006","article-title":"Implantation of total artificial heart in congenital heart disease.","volume":"24","author":"Morales","year":"2012","journal-title":"Semin Thorac Cardiovasc Surg"},{"key":"R39-20230903","doi-asserted-by":"crossref","first-page":"e25","DOI":"10.1016\/j.jtcvs.2012.11.018","article-title":"The role of the total artificial heart in the treatment of post-myocardial infarction ventricular septal defect.","volume":"145","author":"Ashfaq","year":"2013","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R40-20230903","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1097\/imi.0000000000000161","article-title":"SynCardia portable freedom driver: a single-center experience with 11 patients.","volume":"10","author":"Shah","year":"2015","journal-title":"Innovations (Phila)"},{"key":"R41-20230903","doi-asserted-by":"crossref","first-page":"103","DOI":"10.12659\/MSM.889875","article-title":"Primary cardiac angiosarcoma - a review.","volume":"20","author":"Patel","year":"2014","journal-title":"Med Sci Monit"},{"key":"R42-20230903","doi-asserted-by":"crossref","first-page":"2707","DOI":"10.1245\/s10434-012-2334-2","article-title":"Cardiac angiosarcoma management and outcomes: 20-year single-institution experience.","volume":"19","author":"Look Hong","year":"2012","journal-title":"Ann Surg Oncol"},{"key":"R43-20230903","doi-asserted-by":"crossref","first-page":"539","DOI":"10.1177\/0218492312462041","article-title":"Post-infarction ventricular septal defect: surgical outcomes in the last decade.","volume":"21","author":"Yam","year":"2013","journal-title":"Asian Cardiovasc Thorac Ann"},{"key":"R44-20230903","first-page":"46","article-title":"Percutaneous ventricular assist device support in a patient with a postinfarction ventricular septal defect.","volume":"35","author":"Gregoric","year":"2008","journal-title":"Tex Heart Inst J"},{"key":"R45-20230903","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1016\/j.healun.2013.01.987","article-title":"Left ventricular device implantation for advanced cardiac amyloidosis.","volume":"32","author":"Swiecicki","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R46-20230903","doi-asserted-by":"crossref","first-page":"e13663","DOI":"10.1111\/ctr.13663","article-title":"Mechanical circulatory support for cardiac amyloidosis.","volume":"33","author":"Kittleson","year":"2019","journal-title":"Clin Transplant"},{"key":"R47-20230903","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/j.athoracsur.2012.09.010","article-title":"Combined heart and liver transplantation: the Cleveland clinic experience.","volume":"95","author":"Nagpal","year":"2013","journal-title":"Ann Thorac Surg"},{"issue":"4 suppl","key":"R48-20230903","doi-asserted-by":"crossref","first-page":"S118","DOI":"10.1016\/j.healun.2013.01.250","article-title":"Long-term results with total artificial heart: is it prime time for destination therapy?.","volume":"32","author":"Torregrossa","year":"2013","journal-title":"J Heart Lung Transplant"},{"key":"R49-20230903","doi-asserted-by":"crossref","first-page":"1556","DOI":"10.1016\/S0140-6736(15)60511-6","article-title":"First clinical use of a bioprosthetic total artificial heart: report of two cases.","volume":"386","author":"Carpentier","year":"2015","journal-title":"Lancet"},{"issue":"suppl","key":"R50-20230903","doi-asserted-by":"crossref","first-page":"S14","DOI":"10.1016\/j.healun.2017.01.023","article-title":"Pulsatile outflow in cows supported long-term with the BiVACOR RotaryTAH.","volume":"36","author":"Cohn","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"R51-20230903","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1093\/ejcts\/ezu321","article-title":"System overview of the fully implantable destination therapy\u2013ReinHeart-total artificial heart.","volume":"47","author":"Pelletier","year":"2015","journal-title":"Eur J Cardiothorac Surg"},{"key":"R52-20230903","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1111\/j.1525-1594.2012.01489.x","article-title":"Progress on the design and development of the continuous-flow total artificial heart.","volume":"36","author":"Kobayashi","year":"2012","journal-title":"Artif Organs"},{"key":"R53-20230903","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1111\/aor.12959","article-title":"The oregonheart total artificial heart: design and performance on a mock circulatory loop.","volume":"41","author":"Glynn","year":"2017","journal-title":"Artif Organs"},{"key":"R54-20230903","doi-asserted-by":"crossref","first-page":"670","DOI":"10.1111\/aor.12543","article-title":"Animal experiments of the helical flow total artificial heart.","volume":"39","author":"Abe","year":"2015","journal-title":"Artif Organs"},{"key":"R55-20230903","doi-asserted-by":"crossref","first-page":"500","DOI":"10.1111\/aor.13080","article-title":"Hybrid continuous-flow total artificial heart.","volume":"42","author":"Fox","year":"2018","journal-title":"Artif Organs"},{"key":"R56-20230903","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1016\/j.jtcvs.2016.10.103","article-title":"Building a bioartificial heart: obstacles and opportunities.","volume":"153","author":"Lundberg","year":"2017","journal-title":"J Thorac Cardiovasc Surg"}],"container-title":["Cardiology in Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CRD.0000000000000322","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,3]],"date-time":"2023-09-03T09:12:19Z","timestamp":1693732339000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CRD.0000000000000322"}},"subtitle":["Where Are We?"],"short-title":[],"issued":{"date-parts":[[2020,6,1]]},"references-count":56,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/crd.0000000000000322","relation":{},"ISSN":["1061-5377"],"issn-type":[{"value":"1061-5377","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6,1]]}}}