{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2024,12,21]],"date-time":"2024-12-21T06:40:14Z","timestamp":1734763214431,"version":"3.32.0"},"reference-count":103,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>A fraction of patients (approximately 10%) undergoing heart transplantation require permanent pacemaker (PPM) implantation due to sinus node dysfunction or atrioventricular block, occurring either shortly after surgery or later. The incidence of PPM implantation has declined to less than 5% with the introduction of bicaval anastomosis transplantation surgery. Pacing dependency during follow-up varies among recipients. A smaller subset (1.5\u20133.4%) receives implantable cardioverter-defibrillators (ICDs), but data on their use in transplant recipients are limited, primarily from cohort studies and case series. Sudden cardiac death affects around 10% of transplant recipients, attributed to various nonarrhythmic factors such as acute rejection, late graft failure, and cardiac allograft vasculopathy-induced ischemia. This review offers a comprehensive analysis of the existing data concerning the role of PPMs and ICDs in this population, encompassing leadless PPMs, subcutaneous ICDs, unique considerations, and future directions.<\/jats:p>","DOI":"10.1097\/crd.0000000000000817","type":"journal-article","created":{"date-parts":[[2024,11,13]],"date-time":"2024-11-13T14:04:07Z","timestamp":1731506647000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Cardiac Implantable Electronic Devices in Cardiac Transplant Patients: A Comprehensive Review"],"prefix":"10.1097","author":[{"given":"Shayan","family":"Khan","sequence":"first","affiliation":[{"name":"Department of Cardiology, Pakistan Institute of Medical Sciences, Islamabad, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dana Badry Faried Khaled","family":"Abdo","sequence":"additional","affiliation":[{"name":"Department of Medicine, Royal Blackburn Hospital, Blackburn, UK"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Varda","family":"Mushtaq","sequence":"additional","affiliation":[{"name":"Department of Medicine, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Najeeb","family":"Ahmed","sequence":"additional","affiliation":[{"name":"Department of Medicine, Liaquat University of Medical and Health Sciences, Jamshoro, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kajal","family":"Bai","sequence":"additional","affiliation":[{"name":"Department of Medicine, Chandka Medical College, Larkana, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"FNU","family":"Neelam","sequence":"additional","affiliation":[{"name":"Department of Medicine, Jinnah Sindh Medical University, Karachi, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Maria","family":"Malik","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jahanzeb","family":"Malik","sequence":"additional","affiliation":[{"name":"Department of Cardiovascular Medicine, Cardiovascular Analytics Group, Islamabad, Pakistan"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","published-online":{"date-parts":[[2024,11,13]]},"reference":[{"key":"R1-20241221","doi-asserted-by":"crossref","first-page":"1108","DOI":"10.1111\/j.1540-8159.2008.01149.x","article-title":"Pacemaker therapy for early and late sinus node dysfunction in orthotopic heart transplant recipients: a single center experience.","volume":"31","author":"Luebbert","year":"2008","journal-title":"Pacing Clin Electrophysiol"},{"key":"R2-20241221","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1056\/NEJMoa0906431","article-title":"Cardiac resynchronization therapy for the prevention of heart-failure events.","volume":"361","author":"Moss","year":"2009","journal-title":"N Engl J Med"},{"key":"R3-20241221","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1056\/NEJMoa043399","article-title":"Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.","volume":"352","author":"Bardy","year":"2005","journal-title":"N Engl J Med"},{"key":"R4-20241221","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1016\/j.hrthm.2009.01.005","article-title":"Mode and mechanisms of death after orthotopic heart transplantation.","volume":"6","author":"Vaseghi","year":"2009","journal-title":"Heart Rhythm"},{"key":"R5-20241221","doi-asserted-by":"crossref","first-page":"e004070","DOI":"10.1161\/JAHA.116.004070","article-title":"Early denervation and later reinnervation of the heart following cardiac transplantation: a review.","volume":"5","author":"Awad","year":"2016","journal-title":"J Am Heart Assoc"},{"key":"R6-20241221","doi-asserted-by":"crossref","first-page":"149","DOI":"10.15420\/aer.2014.3.3.149","article-title":"Arrhythmias in the heart transplant patient.","volume":"3","author":"Hamon","year":"2014","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"R7-20241221","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1258\/RSMSMJ.51.3.6","article-title":"Exercise responses following heart transplantation: 5 year follow-up.","volume":"51","author":"Carter","year":"2006","journal-title":"Scott Med J"},{"key":"R8-20241221","doi-asserted-by":"crossref","first-page":"308","DOI":"10.1097\/00006199-199911000-00006","article-title":"Evidence of time-dependent autonomic reinnervation after heart transplantation.","volume":"48","author":"Doering","year":"1999","journal-title":"Nurs Res"},{"key":"R9-20241221","doi-asserted-by":"crossref","first-page":"1110","DOI":"10.1161\/01.CIR.88.3.1110","article-title":"Functional and neurochemical evidence for partial cardiac sympathetic reinnervation after cardiac transplantation in humans.","volume":"88","author":"Kaye","year":"1993","journal-title":"Circulation"},{"key":"R10-20241221","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/S1010-7940(99)00367-X","article-title":"Incomplete sympathetic reinnervation of the orthotopically transplanted human heart: observation up to 13 years after heart transplantation.","volume":"17","author":"\u00dcberfuhr","year":"2000","journal-title":"Eur J Cardiothorac Surg"},{"key":"R11-20241221","doi-asserted-by":"crossref","first-page":"H350","DOI":"10.1152\/ajpheart.01100.2008","article-title":"Cardiovascular responses to incremental and sustained submaximal exercise in heart transplant recipients.","volume":"296","author":"Scott","year":"2009","journal-title":"Am J Physiol Heart Circ Physiol"},{"key":"R12-20241221","doi-asserted-by":"crossref","first-page":"1349","DOI":"10.1016\/j.healun.2003.10.005","article-title":"Sympathetic nerve sprouting after orthotopic heart transplantation.","volume":"23","author":"Kim","year":"2004","journal-title":"J Heart Lung Transplant"},{"key":"R13-20241221","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1161\/01.CIR.91.1.72","article-title":"Evidence for functional sympathetic reinnervation of left ventricle and coronary arteries after orthotopic cardiac transplantation in humans.","volume":"91","author":"Burke","year":"1995","journal-title":"Circulation"},{"key":"R14-20241221","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1056\/NEJMoa010519","article-title":"Effect of sympathetic reinnervation on cardiac performance after heart transplantation.","volume":"345","author":"Bengel","year":"2001","journal-title":"N Engl J Med"},{"key":"R15-20241221","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1016\/j.hrthm.2013.11.028","article-title":"Cardiac sympathetic denervation in patients with refractory ventricular arrhythmias or electrical storm: intermediate and long-term follow-up.","volume":"11","author":"Vaseghi","year":"2014","journal-title":"Heart Rhythm"},{"key":"R16-20241221","doi-asserted-by":"crossref","first-page":"3070","DOI":"10.1016\/j.jacc.2017.04.035","article-title":"Cardiac sympathetic denervation for refractory ventricular arrhythmias.","volume":"69","author":"Vaseghi","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"R17-20241221","doi-asserted-by":"crossref","first-page":"1960","DOI":"10.1161\/01.CIR.101.16.1960","article-title":"Relationship between regional cardiac hyperinnervation and ventricular arrhythmia.","volume":"101","author":"Cao","year":"2000","journal-title":"Circulation"},{"key":"R18-20241221","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1590\/S0066-782X2000000100002","article-title":"Permanent and temporary pacemaker implantation after orthotopic heart transplantation.","volume":"74","author":"Bacal","year":"2000","journal-title":"Arq Bras Cardiol"},{"key":"R19-20241221","doi-asserted-by":"crossref","first-page":"812","DOI":"10.1016\/S0022-5223(19)34754-3","article-title":"Permanent pacing following cardiac transplantation.","volume":"104","author":"Cooper","year":"1992","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R20-20241221","doi-asserted-by":"crossref","first-page":"e13202","DOI":"10.1111\/ctr.13202","article-title":"Sinus node dysfunction after heart transplantation\u2014an analysis of risk factors and atrial pacing burden.","volume":"32","author":"Herrmann","year":"2018","journal-title":"Clin Transplant"},{"key":"R21-20241221","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/00001573-200003000-00009","article-title":"Cardiac pacemakers in the transplanted heart: short term with the biatrial anastomosis and unnecessary with the bicaval anastomosis.","volume":"15","author":"Herre","year":"2000","journal-title":"Curr Opin Cardiol"},{"key":"R22-20241221","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1016\/0003-4975(95)00612-O","article-title":"Permanent pacemaker for rejection episodes after heart transplantation: a poor prognostic sign.","volume":"60","author":"Blanche","year":"1995","journal-title":"Ann Thorac Surg"},{"key":"R23-20241221","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1111\/pace.13021","article-title":"A single center study of 1,179 heart transplant patients-factors affecting pacemaker implantation.","volume":"40","author":"Wellmann","year":"2017","journal-title":"Pacing Clin Electrophysiol"},{"key":"R24-20241221","doi-asserted-by":"crossref","first-page":"1567","DOI":"10.1016\/j.hrthm.2010.06.026","article-title":"Long-term outcomes and clinical predictors for pacemaker requiring bradyarrhythmias after cardiac transplantation: analysis of the UNOS\/OPTN cardiac transplant database.","volume":"7","author":"Cantillon","year":"2010","journal-title":"Heart Rhythm"},{"key":"R25-20241221","doi-asserted-by":"crossref","first-page":"e001461","DOI":"10.1161\/JAHA.112.001461","article-title":"Arrhythmias after heart transplantation: mechanisms and management.","volume":"1","author":"Thajudeen","year":"2012","journal-title":"J Am Heart Assoc"},{"key":"R26-20241221","doi-asserted-by":"crossref","first-page":"1226","DOI":"10.1016\/j.healun.2017.05.025","article-title":"Dose-dependent association between amiodarone and severe primary graft dysfunction in orthotopic heart transplantation.","volume":"36","author":"Wright","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"R27-20241221","first-page":"II278","article-title":"Eliminating bradyarrhythmias after orthotopic heart transplantation.","volume":"94","author":"Rothman","year":"1996","journal-title":"Circulation"},{"key":"R28-20241221","doi-asserted-by":"crossref","first-page":"1496","DOI":"10.1016\/S0022-5223(96)70008-9","article-title":"Clinical experience with one hundred consecutive patients undergoing orthotopic heart transplantation with bicaval and pulmonary venous anastomoses.","volume":"112","author":"Trento","year":"1996","journal-title":"J Thorac Cardiovasc Surg"},{"key":"R29-20241221","doi-asserted-by":"crossref","first-page":"2350","DOI":"10.1111\/j.1540-8159.1998.tb01180.x","article-title":"Declining need for pacemaker implantation after cardiac transplantation.","volume":"21","author":"Parry","year":"1998","journal-title":"Pacing Clin Electrophysiol"},{"key":"R30-20241221","first-page":"20","article-title":"Pacemaker use following heart transplantation.","volume":"17","author":"Mallidi","year":"2017","journal-title":"Ochsner J"},{"key":"R31-20241221","doi-asserted-by":"crossref","first-page":"1216","DOI":"10.1097\/TP.0b013e31816b677c","article-title":"Incidence, predictors, and outcomes of cardiac pacing after cardiac transplantation: an 11-year retrospective analysis.","volume":"85","author":"Woo","year":"2008","journal-title":"Transplantation"},{"key":"R32-20241221","first-page":"133","article-title":"Use of theophylline for treatment of prolonged sinus node dysfunction in human orthotopic heart transplantation.","volume":"12","author":"Redmond","year":"1993","journal-title":"J Heart Lung Transplant"},{"key":"R33-20241221","first-page":"1081","article-title":"Longterm follow-up of heart transplant recipients requiring permanent pacemakers.","volume":"14","author":"Raghavan","year":"1995","journal-title":"J Heart Lung Transplant"},{"key":"R34-20241221","doi-asserted-by":"crossref","first-page":"1132","DOI":"10.1016\/j.hrthm.2020.02.021","article-title":"Clinical and procedural characteristics predicting need for chronotropic support and permanent pacing postheart transplantation.","volume":"17","author":"Ustunkaya","year":"2020","journal-title":"Heart Rhythm"},{"key":"R35-20241221","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1016\/j.healun.2009.04.034","article-title":"Long-term outcomes and clinical predictors for pacing after cardiac transplantation.","volume":"28","author":"Cantillon","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R36-20241221","doi-asserted-by":"crossref","first-page":"e51","DOI":"10.1016\/j.jacc.2018.10.044","article-title":"2018 ACC\/AHA\/HRS guideline on the evaluation and management of patients with bradycardia and cardiac conduction delay: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society.","volume":"74","author":"Kusumoto","year":"2019","journal-title":"J Am Coll Cardiol"},{"key":"R37-20241221","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1345\/aph.1D440","article-title":"Terbutaline for chronotropic support in heart transplantation.","volume":"38","author":"Coons","year":"2004","journal-title":"Ann Pharmacother"},{"key":"R38-20241221","first-page":"342","article-title":"Treatment of junctional rhythm after heart transplantation with terbutaline.","volume":"8","author":"Cook","year":"1989","journal-title":"J Heart Transplant"},{"key":"R39-20241221","doi-asserted-by":"crossref","first-page":"S115","DOI":"10.1016\/j.healun.2014.01.026","article-title":"Terbutaline for treatment of sinus node dysfunction following heart transplantation.","volume":"33","author":"Doligalski","year":"2014","journal-title":"J Heart Lung Transplant"},{"key":"R40-20241221","doi-asserted-by":"crossref","first-page":"396","DOI":"10.1016\/0735-1097(96)00162-3","article-title":"Bradycardia after heart transplantation: reversal with theophylline.","volume":"28","author":"Bertolet","year":"1996","journal-title":"J Am Coll Cardiol"},{"key":"R41-20241221","doi-asserted-by":"crossref","first-page":"1222","DOI":"10.1536\/ihj.19-116","article-title":"Cilostazol is useful for the treatment of sinus bradycardia and associated hemodynamic deterioration following heart transplantation.","volume":"60","author":"Uchikawa","year":"2019","journal-title":"Int Heart J"},{"key":"R42-20241221","doi-asserted-by":"crossref","first-page":"3074","DOI":"10.1016\/j.transproceed.2011.08.039","article-title":"Early and late indications for implantation of cardiac pacemakers in patients after heart transplantation: a single center experience.","volume":"43","author":"Noworolski","year":"2011","journal-title":"Transplant Proc"},{"key":"R43-20241221","doi-asserted-by":"crossref","first-page":"5440","DOI":"10.21037\/jtd.2019.11.45","article-title":"Risk factors and survival of patients with permanent pacemaker implantation after heart transplantation.","volume":"11","author":"Rivinius","year":"2019","journal-title":"J Thorac Dis"},{"key":"R44-20241221","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1111\/j.1540-8159.2010.02906.x","article-title":"Permanent pacing for late-onset atrioventricular block in patients with heart transplantation: a single center experience.","volume":"34","author":"Tay","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"R45-20241221","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/01.TP.0000071933.14397.43","article-title":"Cause of atrioventricular block in patients after heart transplantation.","volume":"76","author":"Cui","year":"2003","journal-title":"Transplantation"},{"key":"R46-20241221","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1097\/MAT.0000000000000873","article-title":"Conduction abnormalities associated with tricuspid annuloplasty in cardiac transplantation.","volume":"65","author":"Rubin","year":"2019","journal-title":"ASAIO J"},{"key":"R47-20241221","doi-asserted-by":"crossref","first-page":"1257","DOI":"10.1016\/j.healun.2011.05.010","article-title":"Permanent pacemaker implantation early and late after heart transplantation: clinical indication, risk factors and prognostic implications.","volume":"30","author":"Jones","year":"2011","journal-title":"J Heart Lung Transplant"},{"key":"R48-20241221","first-page":"1837","article-title":"Accelerated graft dysfunction in heart transplant patients with persistent atrioventricular conduction block.","volume":"18","author":"Lee","year":"2016","journal-title":"Europace"},{"key":"R49-20241221","doi-asserted-by":"crossref","first-page":"1510","DOI":"10.1111\/j.1540-8159.1999.tb00356.x","article-title":"Optimal cardiac pacing after heart transplantation.","volume":"22","author":"Melton","year":"1999","journal-title":"Pacing Clin Electrophysiol"},{"key":"R50-20241221","doi-asserted-by":"crossref","first-page":"2932","DOI":"10.1161\/01.CIR.0000072769.17295.B1","article-title":"Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction.","volume":"107","author":"Sweeney","year":"2003","journal-title":"Circulation"},{"key":"R51-20241221","doi-asserted-by":"crossref","first-page":"1288","DOI":"10.1016\/j.amjcard.2006.06.018","article-title":"Prevalence, patterns of development, and prognosis of right bundle branch block in heart transplant recipients.","volume":"98","author":"Marcus","year":"2006","journal-title":"Am J Cardiol"},{"key":"R52-20241221","doi-asserted-by":"crossref","first-page":"680","DOI":"10.1002\/clc.4960210914","article-title":"Incidence and prognostic value of electrocardiographic abnormalities after heart transplantation.","volume":"21","author":"Golshayan","year":"1998","journal-title":"Clin Cardiol"},{"key":"R53-20241221","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1016\/j.jelectrocard.2013.09.006","article-title":"Electrocardiographic abnormalities in the first year after heart transplantation.","volume":"47","author":"Pickham","year":"2014","journal-title":"J Electrocardiol"},{"key":"R54-20241221","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1093\/europace\/eun149","article-title":"Successful cardiac resynchronization therapy after heart transplantation.","volume":"10","author":"Apor","year":"2008","journal-title":"Europace"},{"key":"R55-20241221","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1016\/j.healun.2010.01.009","article-title":"Cardiac resynchronization therapy after atrioventricular node ablation for rapid atrial fibrillation in a heart transplant recipient with late allograft dysfunction.","volume":"29","author":"Mariani","year":"2010","journal-title":"J Heart Lung Transplant"},{"key":"R56-20241221","doi-asserted-by":"crossref","first-page":"72","DOI":"10.5543\/tkda.2013.32855","article-title":"Cardiac resynchronization treatment in a patient with hypertrophic cardiomyopathy after heart transplantation.","volume":"41","author":"Vural","year":"2013","journal-title":"Turk Kardiyol Dern Ars"},{"key":"R57-20241221","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1007\/s11936-019-0763-y","article-title":"Leadless pacemakers: recent and future developments.","volume":"21","author":"Kroman","year":"2019","journal-title":"Curr Treat Options Cardiovasc Med"},{"key":"R58-20241221","doi-asserted-by":"crossref","first-page":"1458","DOI":"10.1161\/CIRCULATIONAHA.116.025037","article-title":"Permanent leadless cardiac pacemaker therapy: a comprehensive review.","volume":"135","author":"Tjong","year":"2017","journal-title":"Circulation"},{"key":"R59-20241221","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1016\/j.amjcard.2019.05.001","article-title":"Leadless pacemaker implant after heart transplant.","volume":"124","author":"Araj","year":"2019","journal-title":"Am J Cardiol"},{"key":"R60-20241221","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1016\/j.recesp.2018.02.016","article-title":"Leadless pacemaker implantation in a transplanted heart.","volume":"72","author":"Mart\u00ednez-Sande","year":"2019","journal-title":"Rev Esp Cardiol"},{"key":"R61-20241221","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1111\/jce.13851","article-title":"Leadless pacemaker implant in patients with preexisting infections: results from the Micra Postapproval Registry.","volume":"30","author":"El-Chami","year":"2019","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R62-20241221","doi-asserted-by":"crossref","first-page":"1105","DOI":"10.1111\/pace.13752","article-title":"Incidence and outcomes of systemic infections in patients with leadless pacemakers: data from the Micra IDE study.","volume":"42","author":"El-Chami","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"R63-20241221","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/j.jacep.2019.10.017","article-title":"Atrioventricular synchronous pacing using a leadless ventricular pacemaker: results from the MARVEL 2 study.","volume":"6","author":"Steinwender","year":"2020","journal-title":"JACC Clin Electrophysiol"},{"key":"R64-20241221","doi-asserted-by":"crossref","first-page":"e007124","DOI":"10.1161\/CIRCEP.118.007124","article-title":"Impact of leadless pacemaker therapy on cardiac and atrioventricular valve function through 12 months of follow-up.","volume":"12","author":"Beurskens","year":"2019","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R65-20241221","doi-asserted-by":"crossref","first-page":"542","DOI":"10.1111\/pace.13648","article-title":"Leadless pacemaker implantation: a feasible and reasonable option in transcatheter heart valve replacement patients.","volume":"42","author":"Moore","year":"2019","journal-title":"Pacing Clin Electrophysiol"},{"key":"R66-20241221","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1016\/j.healun.2009.01.011","article-title":"Sudden cardiac death of two heart transplant patients with correctly functioning implantable cardioverter defibrillators.","volume":"28","author":"Marzoa-Rivas","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R67-20241221","doi-asserted-by":"crossref","first-page":"e13490","DOI":"10.1111\/ctr.13490","article-title":"The evolving risk of sudden cardiac death after heart transplant. An analysis of the ISHLT Thoracic Transplant Registry.","volume":"33","author":"Alba","year":"2019","journal-title":"Clin Transplant"},{"key":"R68-20241221","doi-asserted-by":"crossref","first-page":"e13206","DOI":"10.1111\/ctr.13206","article-title":"Incidence and predictors of sudden cardiac death after heart transplantation: a systematic review and metaanalysis.","volume":"32","author":"Alba","year":"2018","journal-title":"Clin Transplant"},{"key":"R69-20241221","doi-asserted-by":"crossref","first-page":"1684","DOI":"10.1016\/j.hrthm.2014.07.016","article-title":"Incidence, predictors, and temporal trends of sudden cardiac death after heart transplantation.","volume":"11","author":"Vakil","year":"2014","journal-title":"Heart Rhythm"},{"key":"R70-20241221","doi-asserted-by":"crossref","first-page":"682","DOI":"10.1016\/j.healun.2015.12.011","article-title":"Implantable cardioverter-defibrillators in a heart transplant population: a single-center experience.","volume":"35","author":"Neylon","year":"2016","journal-title":"J Heart Lung Transplant"},{"key":"R71-20241221","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1161\/CIRCHEARTFAILURE.108.814525","article-title":"The efficacy of implantable cardioverter-defibrillators in heart transplant recipients: results from a multicenter registry.","volume":"2","author":"Tsai","year":"2009","journal-title":"Circ Heart Fail"},{"key":"R72-20241221","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.jacep.2019.11.013","article-title":"Implantable cardioverter-defibrillators in heart transplant recipients with allograft failure.","volume":"6","author":"DeFilippis","year":"2020","journal-title":"Clin Electrophysiol"},{"key":"R73-20241221","doi-asserted-by":"crossref","first-page":"S178","DOI":"10.1016\/S1053-2498(02)01018-5","article-title":"Implantable cardioverter defibrillators in heart transplant patients at risk for sudden death: shocking news?","volume":"22","author":"Cogert","year":"2003","journal-title":"J Heart Lung Transplant"},{"key":"R74-20241221","doi-asserted-by":"crossref","first-page":"931","DOI":"10.1016\/j.hrthm.2005.06.018","article-title":"Use of the implantable cardioverter-defibrillator in long-term survivors of orthotopic heart transplantation.","volume":"2","author":"Ptaszek","year":"2005","journal-title":"Heart Rhythm"},{"key":"R75-20241221","first-page":"S201","article-title":"Implantable cardioverter defibrillator use after heart transplantation: a single center experience.","volume":"17","author":"Rubin","year":"2020","journal-title":"Heart Rhythm"},{"key":"R76-20241221","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1161\/CIRCEP.110.958397","article-title":"Comparison of a novel, single-lead atrial sensing system with a dual-chamber implantable cardioverter-defibrillator system in patients without antibradycardia pacing indications: results of a randomized study.","volume":"4","author":"Sticherling","year":"2011","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R77-20241221","doi-asserted-by":"crossref","first-page":"e91","DOI":"10.1016\/j.jacc.2017.10.054","article-title":"2017 AHA\/ACC\/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: a report of the American College of Cardiology\/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society.","volume":"72","author":"Al-Khatib","year":"2018","journal-title":"J Am Coll Cardiol"},{"key":"R78-20241221","doi-asserted-by":"crossref","first-page":"847","DOI":"10.1016\/j.healun.2009.04.016","article-title":"Implantable defibrillators and cardiac resynchronization therapy in heart transplant recipients: results of a national survey.","volume":"28","author":"McDowell","year":"2009","journal-title":"J Heart Lung Transplant"},{"key":"R79-20241221","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1053\/j.jvca.2017.03.035","article-title":"Reporting the first subcutaneous ICD placed in the immediate postorthotopic heart transplant period for acute cellular rejection-associated cardiac arrest and investigating the role of secondary prevention ICDs in this population.","volume":"31","author":"Kaushal","year":"2017","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"R80-20241221","doi-asserted-by":"crossref","first-page":"2047","DOI":"10.1016\/j.jacc.2016.08.044","article-title":"Long-term clinical outcomes of subcutaneous versus transvenous implantable defibrillator therapy.","volume":"68","author":"Brouwer","year":"2016","journal-title":"J Am Coll Cardiol"},{"key":"R81-20241221","doi-asserted-by":"crossref","first-page":"ehw353","DOI":"10.1093\/eurheartj\/ehw353","article-title":"Indications and use of the wearable cardiac defibrillator.","author":"Sharma","year":"2016","journal-title":"Eur Heart J"},{"key":"R82-20241221","doi-asserted-by":"crossref","first-page":"1715","DOI":"10.1161\/CIR.0000000000000394","article-title":"Wearable cardioverter-defibrillator therapy for the prevention of sudden cardiac death: a science advisory from the American Heart Association.","volume":"133","author":"Piccini","year":"2016","journal-title":"Circulation"},{"key":"R83-20241221","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1002\/ejhf.1102","article-title":"Paroxysmal bradyarrhythmias are frequent among heart transplant recipients with unexplained syncope: a study based on implantable loop recorders.","volume":"20","author":"Mart\u00ednez-Paz","year":"2018","journal-title":"Eur J Heart Fail"},{"key":"R84-20241221","doi-asserted-by":"crossref","first-page":"1365","DOI":"10.1111\/pace.13458","article-title":"Meta-analysis of the incidence of lead dislodgement with conventional and leadless pacemaker systems.","volume":"41","author":"Wang","year":"2018","journal-title":"Pacing Clin Electrophysiol"},{"key":"R85-20241221","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1007\/s10840-016-0181-y","article-title":"Right atrial lead fixation type and lead position are associated with significant variation in complications.","volume":"47","author":"Witt","year":"2016","journal-title":"J Interv Card Electrophysiol"},{"key":"R86-20241221","doi-asserted-by":"crossref","first-page":"417","DOI":"10.1111\/j.1540-8159.1979.tb05217.x","article-title":"Comparison of active and passive adhering leads for endocardial pacing.","volume":"2","author":"Furman","year":"1979","journal-title":"Pacing Clin Electrophysiol"},{"key":"R87-20241221","doi-asserted-by":"crossref","first-page":"1152","DOI":"10.1161\/01.CIR.87.4.1152","article-title":"Implantable transvenous cardioverter-defibrillators.","volume":"87","author":"Bardy","year":"1993","journal-title":"Circulation"},{"key":"R88-20241221","doi-asserted-by":"crossref","first-page":"1114","DOI":"10.1016\/j.hrthm.2010.12.023","article-title":"The Heart Rhythm Society (HRS)\/American Society of Anesthesiologists (ASA) expert consensus statement on the perioperative management of patients with implantable defibrillators, pacemakers and arrhythmia monitors: facilities and patient management this document was developed as a joint project with the American Society of Anesthesiologists (ASA), and in collaboration with the American Heart Association (AHA), and the Society of Thoracic Surgeons (STS).","volume":"8","author":"Crossley","year":"2011","journal-title":"Heart Rhythm"},{"key":"R89-20241221","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.cardfail.2017.12.012","article-title":"Consequences of retained defibrillator and pacemaker leads after heart transplantation\u2014an underrecognized problem.","volume":"24","author":"Holzhauser","year":"2018","journal-title":"J Card Fail"},{"key":"R90-20241221","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1111\/pace.12274","article-title":"Frequency and sequelae of retained implanted cardiac device material post heart transplantation.","volume":"37","author":"Martin","year":"2014","journal-title":"Pacing Clin Electrophysiol"},{"key":"R91-20241221","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.ahj.2017.04.011","article-title":"Retained cardiac implantable electronic device fragments are not associated with magnetic resonance imaging safety issues, morbidity, or mortality after orthotopic heart transplant.","volume":"190","author":"Austin","year":"2017","journal-title":"Am Heart J"},{"key":"R92-20241221","doi-asserted-by":"crossref","first-page":"3021","DOI":"10.1111\/ajt.14755","article-title":"Burden and consequences of retained cardiovascular implantable electronic device lead fragments after heart transplantation.","volume":"18","author":"Alvarez","year":"2018","journal-title":"Am J Transplant"},{"key":"R93-20241221","doi-asserted-by":"crossref","first-page":"286","DOI":"10.1016\/j.amjcard.2013.03.029","article-title":"Frequency of superior vena cava obstruction in pediatric heart transplant recipients and its relation to previous superior cavopulmonary anastomosis.","volume":"112","author":"Aldoss","year":"2013","journal-title":"Am J Cardiol"},{"key":"R94-20241221","doi-asserted-by":"crossref","first-page":"159","DOI":"10.5603\/KP.2013.0009","article-title":"Post heart transplant extraction of the abandoned fragments of pacing and defibrillation leads: proposed management algorithm.","volume":"71","author":"Kusmierski","year":"2013","journal-title":"Kardiol Pol"},{"key":"R95-20241221","doi-asserted-by":"crossref","first-page":"2319","DOI":"10.1002\/ccr3.1823","article-title":"Highly complicated lead extraction procedure in patient with previous early orthotopic heart transplantation: a first case report.","volume":"6","author":"Schillaci","year":"2018","journal-title":"Clin Case Rep"},{"key":"R96-20241221","first-page":"6270950","article-title":"Transvenous extraction and removal of pacing leads placed after cardiac transplantation.","volume":"2019","author":"Norton","year":"2019","journal-title":"Case Rep Cardiol"},{"key":"R97-20241221","doi-asserted-by":"crossref","first-page":"e503","DOI":"10.1016\/j.hrthm.2017.09.001","article-title":"2017 HRS expert consensus statement on cardiovascular implantable electronic device lead management and extraction.","volume":"14","author":"Kusumoto","year":"2017","journal-title":"Heart Rhythm"},{"key":"R98-20241221","article-title":"Complications of permanent pacemaker implants after heart transplantation: a single center experience.","author":"Rubin","year":"2020","journal-title":"Heart Rhythm"},{"key":"R99-20241221","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/j.1540-8159.2010.02931.x","article-title":"Implantation success and infection in cardiovascular implantable electronic device procedures utilizing an antibacterial envelope.","volume":"34","author":"Bloom","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"R100-20241221","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1111\/pace.12063","article-title":"Use of an antibacterial envelope is associated with reduced cardiac implantable electronic device infections in high-risk patients.","volume":"36","author":"Kolek","year":"2013","journal-title":"Pacing Clin Electrophysiol"},{"key":"R101-20241221","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1186\/1471-2261-12-14","article-title":"Remote noninvasive allograft rejection monitoring for heart transplant recipients: study protocol for the novel evaluation with home electrocardiogram and remote transmission (NEW HEART) study.","volume":"12","author":"Doering","year":"2012","journal-title":"BMC Cardiovasc Disord"},{"key":"R102-20241221","doi-asserted-by":"crossref","first-page":"S288","DOI":"10.1016\/j.healun.2017.01.1438","article-title":"ECG correlates of acute allograft rejection among heart transplant recipients in the NEW HEART study.","volume":"36","author":"Hickey","year":"2017","journal-title":"J Heart Lung Transplant"},{"key":"R103-20241221","doi-asserted-by":"crossref","first-page":"145","DOI":"10.4037\/ajcc2018862","article-title":"Electrocardiographic correlates of acute allograft rejection among heart transplant recipients.","volume":"27","author":"Hickey","year":"2018","journal-title":"Am J Crit Care"}],"container-title":["Cardiology in Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CRD.0000000000000817","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,12,21]],"date-time":"2024-12-21T06:00:41Z","timestamp":1734760841000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CRD.0000000000000817"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,11,13]]},"references-count":103,"URL":"https:\/\/doi.org\/10.1097\/crd.0000000000000817","relation":{},"ISSN":["1538-4683"],"issn-type":[{"type":"electronic","value":"1538-4683"}],"subject":[],"published":{"date-parts":[[2024,11,13]]}}}