{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T04:44:37Z","timestamp":1785818677081,"version":"3.56.0"},"reference-count":50,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"abstract":"<jats:p>\n                    In the treatment of atrial fibrillation (AF), cryoballoon ablation (CBA) is associated with a high incidence of pulmonary vein reconnection, potentially limiting long-term efficacy. Pulsed field ablation (PFA) has emerged as a promising alternative with the potential for improved safety. Hence, this study was conducted to compare the safety and efficacy of PFA with CBA in patients with AF. Several databases were searched for studies that compared PFA with CBA in AF patients and reported safety and efficacy outcomes. A random-effects meta-analysis was performed using RStudios. Binary and continuous outcomes were pooled using odds ratios (ORs) and mean difference, respectively, along with 95% confidence intervals. Statistical significance was set at\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    &lt; 0.05. A total of 26 studies involving 6673 patients were included. PFA showed a reduced incidence of recurrence of any atrial tachyarrhythmia (OR: 0.78; [0.65\u20130.93];\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    value = 0.007), recurrence of AF (OR: 0.64; [0.54\u20130.77];\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    value &lt;0.001), phrenic nerve palsy (OR: 0.16; [0.09\u20130.28];\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    value &lt;0.01), and esophageal injury (OR: 0.41; [0.17\u20130.99];\n                    <jats:italic toggle=\"yes\">P<\/jats:italic>\n                    value = 0.047) as compared with CBA. No significant differences were observed between the groups for the incidence of recurrence of early ATA, atrial flutter, atrial tachycardia, redo procedure, all-cause mortality, access complications, cardiac tamponade, stroke, or transient ischemic attack. These findings support the potential of PFA as a safer and more effective alternative to CBA in the management of AF. Further randomized trials are needed to validate these findings, which should be interpreted cautiously given the limited long-term comparative evidence.\n                  <\/jats:p>","DOI":"10.1097\/crd.0000000000001397","type":"journal-article","created":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T04:00:33Z","timestamp":1785816033000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Pulsed Field Versus Cryoballoon Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis"],"prefix":"10.1097","author":[{"given":"Muhammad","family":"Burhan","sequence":"first","affiliation":[{"name":"Department of Internal Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Momina","family":"Siddiqui","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maliha","family":"Khalid","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Jinnah Sindh Medical University, Karachi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fatima","family":"Hussain","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sahaab","family":"Noor","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Humza","family":"Saeed","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farhan","family":"Naeem","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Massachusetts General Hospital, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shehroze","family":"Tabassum","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, The Wright Center for Graduate Medical Education, Scranton, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jawad","family":"Basit","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Rawalpindi Medical University, Rawalpindi, Pakistan"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohammad","family":"Hamza","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Guthrie Medical Group, Cortland, NY"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ali","family":"Awad","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Wayne State University, Detroit, MI"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mobeen Zaka","family":"Haider","sequence":"additional","affiliation":[{"name":"Department of Cardiology, West Virginia University, Morgantown, WV"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M Chadi","family":"Alraies","sequence":"additional","affiliation":[{"name":"Department of Cardiology, Detroit Medical Center, Detroit, MI."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,8,4]]},"reference":[{"key":"R1-20260804","doi-asserted-by":"crossref","first-page":"1989","DOI":"10.1136\/heartjnl-2018-313350","article-title":"Global rising trends of atrial fibrillation: a major public health concern.","volume":"104","author":"Patel","year":"2018","journal-title":"Heart"},{"key":"R2-20260804","first-page":"467","article-title":"Atrial fibrillation associated with heart failure, stroke and mortality.","volume":"5","author":"Bordignon","year":"2012","journal-title":"J Atr Fibrillation"},{"key":"R3-20260804","doi-asserted-by":"crossref","first-page":"9343","DOI":"10.56238\/arev6n3-297","article-title":"Ablation strategies for atrial fibrillation: unpacking effectiveness and safety across diverse techniques.","volume":"6","author":"Silva","year":"2024","journal-title":"Arac\u00ea"},{"key":"R4-20260804","doi-asserted-by":"crossref","first-page":"545","DOI":"10.1001\/jamacardio.2024.0675","article-title":"Atrial fibrillation ablation in heart failure with reduced vs preserved ejection fraction: a systematic review and meta-analysis.","volume":"9","author":"Oraii","year":"2024","journal-title":"JAMA Cardiol"},{"key":"R5-20260804","doi-asserted-by":"crossref","first-page":"618","DOI":"10.2459\/JCM.0000000000001176","article-title":"First-line therapy: insights from a real-world analysis of cryoablation in patients with atrial fibrillation.","volume":"22","author":"Moltrasio","year":"2021","journal-title":"J Cardiovasc Med (Hagerstown)"},{"key":"R6-20260804","first-page":"927","article-title":"Durable pulmonary vein isolation: the holy grail of atrial fibrillation ablation.","volume":"6","author":"Nguyen","year":"2013","journal-title":"J Atr Fibrillation"},{"key":"R7-20260804","doi-asserted-by":"crossref","first-page":"329","DOI":"10.3390\/bioengineering12040329","article-title":"Pulsed field ablation: a review of preclinical and clinical studies.","volume":"12","author":"Sullivan","year":"2025","journal-title":"Bioengineering (Basel)"},{"key":"R8-20260804","doi-asserted-by":"crossref","first-page":"2232","DOI":"10.3390\/biomedicines12102232","article-title":"Pulsed field ablation of atrial fibrillation: a novel technology for safer and faster ablation.","volume":"12","author":"Carta-Bergaz","year":"2024","journal-title":"Biomedicines"},{"key":"R9-20260804","doi-asserted-by":"crossref","first-page":"i4919","DOI":"10.1136\/bmj.i4919","article-title":"ROBINS-I: a tool for assessing risk of bias in non-randomised studies of interventions.","volume":"355","author":"Sterne","year":"2016","journal-title":"BMJ"},{"key":"R10-20260804","doi-asserted-by":"crossref","first-page":"l4898","DOI":"10.1136\/bmj.l4898","article-title":"RoB 2: a revised tool for assessing risk of bias in randomised trials.","volume":"366","author":"Sterne","year":"2019","journal-title":"BMJ"},{"key":"R11-20260804","doi-asserted-by":"crossref","first-page":"567","DOI":"10.1007\/s10840-022-01359-x","article-title":"Pulsed field ablation for pulmonary vein isolation: real-world experience and characterization of the antral lesion size compared with cryoballoon ablation.","volume":"66","author":"Blockhaus","year":"2023","journal-title":"J Intervent Card Electrophysiol"},{"key":"R12-20260804","doi-asserted-by":"crossref","first-page":"1537","DOI":"10.1016\/j.hrthm.2024.05.032","article-title":"Cost, efficiency, and outcomes of pulsed field ablation vs thermal ablation for atrial fibrillation: a real-world study.","volume":"21","author":"Calvert","year":"2024","journal-title":"Heart Rhythm"},{"key":"R13-20260804","doi-asserted-by":"crossref","first-page":"e033146","DOI":"10.1161\/JAHA.123.033146","article-title":"Pentaspline Pulsed field ablation catheter versus cryoballoon for atrial fibrillation ablation: results from a prospective comparative study.","volume":"13","author":"Chaumont","year":"2024","journal-title":"J Am Heart Assoc"},{"key":"R14-20260804","doi-asserted-by":"crossref","first-page":"1391","DOI":"10.1093\/europace\/euab090","article-title":"Pulsed field ablation selectively spares the oesophagus during pulmonary vein isolation for atrial fibrillation.","volume":"23","author":"Cochet","year":"2021","journal-title":"Europace"},{"key":"R15-20260804","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euae016","article-title":"Pulsed electric field, cryoballoon, and radiofrequency for paroxysmal atrial fibrillation ablation: a propensity score-matched comparison.","volume":"26","author":"Della Rocca","year":"2023","journal-title":"Europace"},{"key":"R16-20260804","doi-asserted-by":"crossref","first-page":"e328","DOI":"10.1016\/j.hrthm.2025.03.1999","article-title":"One-year clinical and safety outcome of obese patients undergoing pulmonary vein isolation for atrial fibrillation with pulsed field ablation or cryoballoon ablation: a propensity-matched analysis.","volume":"22","author":"Feickert","year":"2025","journal-title":"Heart Rhythm"},{"key":"R17-20260804","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1016\/j.jacep.2025.01.009","article-title":"Pulsed-field vs thermal catheter ablation of atrial fibrillation in patients with hypertrophic cardiomyopathy.","volume":"11","author":"Gribissa","year":"2025","journal-title":"JACC Clin Electrophysiol"},{"key":"R18-20260804","first-page":"101684","article-title":"Pulsed-field ablation versus cryoballoon ablation in patients with persistent atrial fibrillation.","volume":"59","author":"Isenegger","year":"2025","journal-title":"Int J Cardiol Heart Vasc"},{"key":"R19-20260804","first-page":"101516","article-title":"Impact of overweight and obesity on radiation dose and outcome in patients undergoing pulmonary vein isolation by cryoballoon and pulsed field ablation.","volume":"55","author":"Jungen","year":"2024","journal-title":"Int J Cardiol Heart Vasc"},{"key":"R20-20260804","doi-asserted-by":"crossref","first-page":"1227","DOI":"10.1016\/j.hrthm.2024.04.045","article-title":"Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation.","volume":"21","author":"Kueffer","year":"2024","journal-title":"Heart Rhythm"},{"key":"R21-20260804","doi-asserted-by":"crossref","first-page":"2018","DOI":"10.1007\/s12350-023-03220-8","article-title":"Visualization of fibroblast activation using 68Ga-FAPI PET\/CT after pulmonary vein isolation with pulsed field compared with cryoballoon ablation.","volume":"30","author":"Kupusovic","year":"2023","journal-title":"J Nucl Cardiol"},{"key":"R22-20260804","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1007\/s10840-023-01651-4","article-title":"Pulsed-field vs. cryoballoon vs. radiofrequency ablation: a propensity score matched comparison of one-year outcomes after pulmonary vein isolation in patients with paroxysmal atrial fibrillation.","volume":"67","author":"Maurhofer","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"R23-20260804","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1111\/jce.16132","article-title":"Pulsed\u2010field ablation does not induce esophageal and periesophageal injury\u2014a new esophageal safety paradigm in catheter ablation of atrial fibrillation.","volume":"35","author":"Grosse Meininghaus","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R24-20260804","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1016\/j.hrthm.2025.01.025","article-title":"Pulsed field ablation in the elderly by a pentaspline multielectrode catheter: safety, efficacy, and comparison with cryoballoon and radiofrequency devices.","volume":"22","author":"Nakasone","year":"2025","journal-title":"Heart Rhythm"},{"key":"R25-20260804","doi-asserted-by":"crossref","first-page":"2828","DOI":"10.1016\/j.hrthm.2024.12.020","article-title":"Pentaspline catheter or cryoballoon for pulmonary vein plus posterior wall isolation in persistent atrial fibrillation: 1-year outcomes.","volume":"22","author":"Pannone","year":"2025","journal-title":"Heart Rhythm"},{"key":"R26-20260804","doi-asserted-by":"crossref","first-page":"1191","DOI":"10.1007\/s10840-024-01748-4","article-title":"Pulsed field ablation and cryoballoon ablation for pulmonary vein isolation: insights on efficacy, safety and cardiac function.","volume":"67","author":"Rattka","year":"2024","journal-title":"J Interv Card Electrophysiol"},{"key":"R27-20260804","doi-asserted-by":"crossref","first-page":"1660","DOI":"10.1056\/NEJMoa2307291","article-title":"Pulsed field or conventional thermal ablation for paroxysmal atrial fibrillation.","volume":"389","author":"Reddy","year":"2023","journal-title":"N Engl J Med"},{"key":"R28-20260804","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1056\/NEJMoa2502280","article-title":"Pulsed field or cryoballoon ablation for paroxysmal atrial fibrillation.","volume":"392","author":"Reichlin","year":"2025","journal-title":"N Engl J Med"},{"key":"R29-20260804","doi-asserted-by":"crossref","first-page":"2019","DOI":"10.1111\/jce.16056","article-title":"Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation.","volume":"34","author":"Schipper","year":"2023","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R30-20260804","first-page":"1864","article-title":"Impact of pulsed-field ablation on intrinsic cardiac autonomic nervous system after pulmonary vein isolation.","volume":"9","author":"Tohoku","year":"2023","journal-title":"J Am Coll Cardiol"},{"key":"R31-20260804","doi-asserted-by":"crossref","first-page":"389","DOI":"10.1161\/CIRCEP.123.011920","article-title":"Pulsed field versus cryoballoon pulmonary vein isolation for atrial fibrillation: efficacy, safety, and long-term follow-up in a 400-patient cohort.","volume":"16","author":"Urbanek","year":"2023","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"R32-20260804","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1007\/s12471-023-01850-8","article-title":"Pulsed field versus cryoballoon ablation for atrial fibrillation: a real-world observational study on procedural outcomes and efficacy.","volume":"32","author":"van de Kar","year":"2024","journal-title":"Neth Heart J"},{"key":"R33-20260804","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1111\/jce.16141","article-title":"Pulsed-field versus cryoballoon ablation for atrial fibrillation-impact of energy source on sedation and analgesia requirement.","volume":"35","author":"Wahedi","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R34-20260804","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1007\/s10840-024-01966-w","article-title":"Efficacy, safety, and somatosensory comparison of pulsed-field ablation and thermal ablation: outcomes from a 2-year follow-up.","volume":"69","author":"Wang","year":"2026","journal-title":"J Interv Card Electrophysiol"},{"key":"R35-20260804","doi-asserted-by":"crossref","first-page":"371","DOI":"10.7150\/ijms.103170","article-title":"Comparison of catheter ablation in patients with paroxysmal non-valvular atrial fibrillation and heart failure with preserved ejection fraction.","volume":"22","author":"Zhang","year":"2025","journal-title":"Int J Med Sci"},{"key":"R36-20260804","article-title":"Comparison of therapeutic effects between pulsed field ablation and cryoballoon ablation in the treatment of atrial fibrillation: a systematic review and meta-analysis [published online ahead of print November 14, 2024].","author":"Wan","journal-title":"Cardiol Rev"},{"key":"R37-20260804","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad329","article-title":"Efficacy and safety of pulmonary vein isolation with pulsed field ablation vs. novel cryoballoon ablation system for atrial fibrillation.","volume":"25","author":"Badertscher","year":"2023","journal-title":"Europace"},{"key":"R38-20260804","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1111\/pace.14971","article-title":"Meta-analysis of pulsed-field ablation versus cryoablation for atrial fibrillation.","volume":"47","author":"Zhang","year":"2024","journal-title":"Pacing Clin Electrophysiol"},{"key":"R39-20260804","doi-asserted-by":"crossref","DOI":"10.1093\/ehjopen\/oeae044","article-title":"Efficacy and safety of pulsed field ablation compared to cryoballoon ablation in the treatment of atrial fibrillation: a meta-analysis.","volume":"4","author":"Rudolph","year":"2024","journal-title":"Eur Heart J Open"},{"key":"R40-20260804","doi-asserted-by":"crossref","DOI":"10.1093\/europace\/euad122.154","article-title":"Safetyand durability of PFA for pulmonary vein isolation: comparison to a reference RF data base.","volume":"25","author":"Becker","year":"2023","journal-title":"Europace"},{"key":"R41-20260804","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.hrthm.2024.06.036","article-title":"Prevalence, timing, and impact of early recurrence of atrial tachyarrhythmias after pulsed field ablation: a secondary analysis of the PULSED AF trial.","volume":"22","author":"Boersma","year":"2025","journal-title":"Heart Rhythm"},{"key":"R42-20260804","doi-asserted-by":"crossref","first-page":"323","DOI":"10.1007\/s10840-021-00987-z","article-title":"Association between early recurrences of atrial tachyarrhythmias and long-term outcomes in patients after repeat atrial fibrillation ablation.","volume":"64","author":"Darden","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"R43-20260804","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s10840-022-01210-3","article-title":"Procedural and outcome impact of obesity in cryoballoon versus radiofrequency pulmonary vein isolation in atrial fibrillation patients.","volume":"65","author":"Scheurlen","year":"2022","journal-title":"J Interv Card Electrophysiol"},{"key":"R44-20260804","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1016\/j.radmp.2021.09.003","article-title":"Effect of fluoroscopy frame rate on radiation exposure and in-hospital outcomes in cardiovascular implantable electronic device implantation procedures.","volume":"2","author":"Ali","year":"2021","journal-title":"Radiat Med Protect"},{"key":"R45-20260804","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1007\/s12325-023-02765-x","article-title":"Comparative safety of pulsed field ablation and cryoballoon ablation technologies for pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a critical literature review and indirect treatment comparison.","volume":"41","author":"Maccioni","year":"2024","journal-title":"Adv Ther"},{"key":"R46-20260804","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s43057-024-00138-w","article-title":"Early- and mid-term outcomes following redo aortic surgeries: a retrospective cohort study.","volume":"32","author":"Akintoye","year":"2024","journal-title":"Cardiothorac Surg"},{"key":"R47-20260804","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1111\/jce.16237","article-title":"Impact of artificial intelligence arrhythmia mapping on time to first ablation, procedure duration, and fluoroscopy use.","volume":"35","author":"Fox","year":"2024","journal-title":"J Cardiovasc Electrophysiol"},{"key":"R48-20260804","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/s12947-018-0137-8","article-title":"Left atrium remodeling predicts late recurrence of paroxysmal atrial fibrillation after second generation cryoballoon ablation.","volume":"16","author":"Motoc","year":"2018","journal-title":"Cardiovasc Ultrasound"},{"key":"R49-20260804","doi-asserted-by":"crossref","first-page":"e695","DOI":"10.1212\/WNL.0000000000007935","article-title":"Effect of coexisting vascular disease on long-term risk of recurrent events after TIA or stroke.","volume":"93","author":"Boulanger","year":"2019","journal-title":"Neurology"},{"key":"R50-20260804","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1002\/jmrs.315","article-title":"Factors contributing to radiation dose for patients and operators during diagnostic cardiac angiography.","volume":"66","author":"Crowhurst","year":"2019","journal-title":"J Med Radiat Sci"}],"container-title":["Cardiology in Review"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/CRD.0000000000001397","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T04:00:41Z","timestamp":1785816041000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/CRD.0000000000001397"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8,4]]},"references-count":50,"URL":"https:\/\/doi.org\/10.1097\/crd.0000000000001397","relation":{},"ISSN":["1061-5377","1538-4683"],"issn-type":[{"value":"1061-5377","type":"print"},{"value":"1538-4683","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,8,4]]}}}