{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T12:47:37Z","timestamp":1782478057809,"version":"3.54.5"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,2,17]],"date-time":"2026-02-17T00:00:00Z","timestamp":1771286400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Catheter-based urodynamic studies remain the standard for diagnosing lower urinary tract dysfunction, but are limited by discomfort, infection risk, and restricted monitoring duration. Emerging implantable bladder sensors offer the potential for real-time wireless pressure monitoring without the need for catheters, with promising applications in neurology. This study was aimed to systematically review and compare the performance, safety, and translational readiness of intravesical and submucosal implantable bladder sensors used for real-time urodynamic assessments in preclinical and clinical studies.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Materials and methods:<\/jats:title>\n                    <jats:p>A systematic literature search was conducted in PubMed, Scopus, and IEEE Xplore from their inception to July 10, 2025, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Studies that evaluated wireless implantable bladder pressure sensors in animal or human models were included. Data on the pressure fidelity, biocompatibility, implantation site, and signal stability were extracted and compared.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Four studies met the inclusion criteria: 3 preclinical studies (rabbit or pig) and 1 human feasibility trial. Intravesical sensors showed superior pressure fidelity (correlation coefficients up to r = 0.885), minimal error (\u00b11\u2009cm H\n                      <jats:sub>2<\/jats:sub>\n                      O), and favorable safety with no adverse effects. In humans, the UroMonitor device demonstrated an event-detection accuracy of 98% and was well tolerated. Submucosal devices achieved high event-specific correlations (r = 0.75\u20130.94) but were limited by erosion and signal degradation. Heterogeneity in sensor design, implantation duration, and biocompatibility has limited direct comparisons.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>Intravesical implantable sensors demonstrated higher accuracy, safety, and translational readiness than submucosal alternatives. The success of the UroMonitor in human feasibility studies underscores its potential for catheter-free ambulatory bladder pressure monitoring. Future studies should focus on long-term implantation, artificial intelligence integration, and comparative trials using conventional urodynamics.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/cu9.0000000000000331","type":"journal-article","created":{"date-parts":[[2026,2,24]],"date-time":"2026-02-24T05:00:10Z","timestamp":1771909210000},"page":"235-243","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Implantable bladder sensors for real-time urodynamics: A systematic review of preclinical and clinical evidence in neuro-urology"],"prefix":"10.1097","volume":"20","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0085-3284","authenticated-orcid":false,"given":"Kirolos","family":"Eskandar","sequence":"first","affiliation":[{"name":"Faculty of Medicine and Surgery, Helwan University, Cairo, Egypt"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,2,17]]},"reference":[{"issue":"4","key":"R2-20260626","doi-asserted-by":"crossref","first-page":"773","DOI":"10.1097\/JU.0000000000002862","article-title":"Health care economic burden of treatment and rehabilitation for neurogenic lower urinary tract dysfunction: A systematic review.","volume":"208","author":"Abedi","year":"2022","journal-title":"J Urol"},{"issue":"8","key":"R3-20260626","doi-asserted-by":"crossref","first-page":"1078","DOI":"10.1001\/jamainternmed.2018.2417","article-title":"A multicenter study of patient-reported infectious and noninfectious complications associated with indwelling urethral catheters.","volume":"178","author":"Saint","year":"2018","journal-title":"JAMA Intern Med"},{"issue":"1","key":"R4-20260626","first-page":"100","article-title":"Rate of urinary tract infection after urodynamic study in pelvic floor clinic.","volume":"11","author":"Ghanbari","year":"2020","journal-title":"Caspian J Intern Med"},{"issue":"9","key":"R5-20260626","doi-asserted-by":"crossref","first-page":"17686","DOI":"10.3390\/s140917686","article-title":"Development of clinically relevant implantable pressure sensors: Perspectives and challenges.","volume":"14","author":"Clausen","year":"2014","journal-title":"Sensors"},{"issue":"1","key":"R6-20260626","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1097\/JU.0000000000003451","article-title":"First in human subjects testing of the uromonitor: A catheter-free wireless ambulatory bladder pressure monitor.","volume":"210","author":"Frainey","year":"2023","journal-title":"J Urol"},{"issue":"1","key":"R7-20260626","doi-asserted-by":"crossref","first-page":"e0168375","DOI":"10.1371\/journal.pone.0168375","article-title":"Suburothelial bladder contraction detection with implanted pressure sensor.","volume":"12","author":"Majerus","year":"2017","journal-title":"PLoS One"},{"issue":"12","key":"R8-20260626","doi-asserted-by":"crossref","first-page":"e0225821","DOI":"10.1371\/journal.pone.0225821","article-title":"Wireless intravesical device for real-time bladder pressure measurement: Study of consecutive voiding in awake minipigs.","volume":"14","author":"Soebadi","year":"2019","journal-title":"PLoS One"},{"key":"R9-20260626","doi-asserted-by":"crossref","first-page":"2067","DOI":"10.1109\/TNSRE.2021.3117518","article-title":"Feasibility of real-time conditional sacral neuromodulation using wireless bladder pressure sensor.","volume":"29","author":"Majerus","year":"2021","journal-title":"IEEE Trans Neural Syst Rehabil Eng"},{"issue":"6","key":"R10-20260626","doi-asserted-by":"crossref","first-page":"1669","DOI":"10.1002\/nau.24035","article-title":"First-in-human implantation of a mid-field powered neurostimulator at the sacral nerve: Results from an acute study.","volume":"38","author":"van Kerrebroeck","year":"2019","journal-title":"Neurourol Urodyn"},{"issue":"16","key":"R11-20260626","doi-asserted-by":"crossref","first-page":"4610","DOI":"10.3390\/s20164610","article-title":"Designing and implementing an implantable wireless micromanometer system for real-time bladder pressure monitoring: A preliminary study.","volume":"20","author":"Li","year":"2020","journal-title":"Sensors"},{"issue":"6","key":"R12-20260626","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1111\/iju.14238","article-title":"Novel implantable pressure and acceleration sensor for bladder monitoring.","volume":"27","author":"Soebadi","year":"2020","journal-title":"Int J Urol"},{"issue":"1","key":"R13-20260626","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1177\/0954411918754925","article-title":"Is submucosal bladder pressure monitoring feasible?","volume":"233","author":"Basu","year":"2019","journal-title":"Proc Inst Mech Eng H"},{"key":"R14-20260626","doi-asserted-by":"crossref","article-title":"Wireless bladder pressure monitor for closed-loop bladder neuromodulation.","author":"Majerus","DOI":"10.1109\/ICSENS.2016.7808967"},{"issue":"4","key":"R15-20260626","first-page":"721","article-title":"Real-time classification of bladder events for effective diagnosis and treatment of urinary incontinence.","volume":"63","author":"Karam","year":"2016","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"R16-20260626","doi-asserted-by":"crossref","first-page":"385","DOI":"10.1002\/nau.23310","article-title":"Conditional neuromodulation of neurogenic detrusor overactivity using transrectal stimulation in patients with spinal cord injury: A proof of principle study.","volume":"37","author":"Knight","year":"2018","journal-title":"Neurourol Urodyn"},{"issue":"14","key":"R18-20260626","doi-asserted-by":"crossref","first-page":"e2400868121","DOI":"10.1073\/pnas.2400868121","article-title":"A wireless, implantable bioelectronic system for monitoring urinary bladder function following surgical recovery.","volume":"121","author":"Kim","year":"2024","journal-title":"Proc Natl Acad Sci U S A"},{"key":"R19-20260626","first-page":"2500107","article-title":"Development of an implantable wireless and batteryless bladder pressure monitor system for lower urinary tract dysfunction.","volume":"8","author":"Zhong","year":"2019","journal-title":"IEEE J Transl Eng Health Med"},{"issue":"6","key":"R20-20260626","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1177\/09544119231172272","article-title":"Automated closed-loop stimulation to inhibit neurogenic bladder overactivity.","volume":"238","author":"Majerus","year":"2024","journal-title":"Proc Inst Mech Eng H"},{"key":"R21-20260626","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1016\/j.medengphy.2021.11.001","article-title":"In-vitro tribological study and submodeling finite element technique in analyzing wear of zirconia toughened alumina against alumina with bio-lubricants for hip implants.","volume":"98","author":"Shankar","year":"2021","journal-title":"Med Eng Phys"},{"issue":"6","key":"R22-20260626","doi-asserted-by":"crossref","first-page":"1127","DOI":"10.1007\/s12034-013-0570-0","article-title":"Comparison of in vivo biocompatibilities between parylene-C and polydimethylsiloxane for implantable microelectronic devices.","volume":"36","author":"Lee","year":"2013","journal-title":"Bull Mater Sci"},{"issue":"2","key":"R25-20260626","doi-asserted-by":"crossref","first-page":"441","DOI":"10.1007\/s11255-023-03795-8","article-title":"An automatic diagnostic system for the urodynamic study applying in lower urinary tract dysfunction.","volume":"56","author":"Ding","year":"2024","journal-title":"Int Urol Nephrol"}],"container-title":["Current Urology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/CU9.0000000000000331","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,6,26]],"date-time":"2026-06-26T12:00:48Z","timestamp":1782475248000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/CU9.0000000000000331"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,2,17]]},"references-count":21,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/cu9.0000000000000331","relation":{},"ISSN":["1661-7649"],"issn-type":[{"value":"1661-7649","type":"print"}],"subject":[],"published":{"date-parts":[[2026,2,17]]}}}