{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,21]],"date-time":"2026-10-21T22:27:21Z","timestamp":1792621641836,"version":"4.5.0"},"reference-count":42,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dimens Crit Care Nurs"],"published-print":{"date-parts":[[2020,9]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Hemodynamic monitoring, implemented by the placement of peripheral arterial catheters (PACs), is a characterizing aspect of the intensive care units. Peripheral arterial catheters can continually detect blood pressure and quickly conduct blood sampling. The use of PACs is generally considered safe, without serious complications. Currently, only 25% of the implanted catheters are actually subject to complications, including accidental removal, dislocation, occlusion, and infection. All of these complications arise from inadequate catheter stabilization at the level of the skin. This study aimed to summarize and describe the effectiveness and characteristics of dressings and securement devices for catheter stabilization.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Methods<\/jats:title>\n            <jats:p>A systematic review of literature from the following databases was conducted: MEDLINE, CINAHL, Cochrane, EMBASE, and OvidSP. We used the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement to guide article selection and reporting.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>Herein 626 articles were referred, with 5 directly related to the topic under discussion. We found 3 studies that describe PAC failure and 4 about dislodgement. We described 6 types of dressings or securement devices and classified them into 3 categories for classifying PAC dressings or securement devices. These were detected and grouped as adhesive tissues, sutureless devices, and transparent polyurethane dressings.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions<\/jats:title>\n            <jats:p>Current research indicates that transparent polyurethane dressings offer the most effective catheter stabilization, but adhesive tissues may constitute a valid alternative. However, there are limited high-quality studies about effective dressings and securement devices for PACs.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/dcc.0000000000000433","type":"journal-article","created":{"date-parts":[[2020,7,31]],"date-time":"2020-07-31T14:00:10Z","timestamp":1596204010000},"page":"242-250","source":"Crossref","is-referenced-by-count":13,"title":["Dressings and Securement Devices of Peripheral Arterial Catheters in Intensive Care Units and Operating Theaters"],"prefix":"10.1097","volume":"39","author":[{"given":"Francesco","family":"Gravante","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andrea","family":"Lombardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anna Maria","family":"Gagliardi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Antonello","family":"Pucci","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roberto","family":"Latina","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"issue":"4","key":"bib1-20230908","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1097\/NAN.0b013e31825af099","article-title":"Short peripheral intravenous catheters and infections","volume":"35","year":"2012","journal-title":"J Infus Nurs"},{"issue":"4","key":"bib2-20230908","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1097\/01.CCM.0000206105.05626.15","article-title":"Critical care delivery in the United States: distribution of services and compliance with Leapfrog recommendations","volume":"34","year":"2006","journal-title":"Crit Care Med"},{"issue":"3","key":"bib3-20230908","doi-asserted-by":"crossref","first-page":"650","DOI":"10.1097\/ALN.0000000000000008","article-title":"Variation of arterial and central venous catheter use in United States intensive care units","volume":"120","year":"2014","journal-title":"Anesthesiology"},{"issue":"6","key":"bib4-20230908","doi-asserted-by":"crossref","first-page":"1276","DOI":"10.1097\/01.CCM.0000166350.90812.D4","article-title":"Prospective study of arterial and central venous catheter colonization and of arterial- and central venous catheter-related bacteremia in intensive care units","volume":"33","year":"2005","journal-title":"Crit Care Med"},{"issue":"1","key":"bib5-20230908","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.jhin.2010.01.005","article-title":"Assessment of peripheral arterial catheters as a source of sepsis in the critically ill: a narrative review","volume":"75","year":"2010","journal-title":"J Hosp Infect"},{"issue":"3","key":"bib6-20230908","doi-asserted-by":"crossref","first-page":"199","DOI":"10.1186\/cc1489","article-title":"Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine","volume":"6","year":"2002","journal-title":"Crit Care"},{"issue":"31","key":"bib7-20230908","doi-asserted-by":"crossref","first-page":"55","DOI":"10.7748\/ns.19.31.55.s51","article-title":"Haemodynamic monitoring: arterial catheters","volume":"19","year":"2005","journal-title":"Nurs Stand"},{"issue":"15","key":"bib8-20230908","doi-asserted-by":"crossref","first-page":"e13","DOI":"10.1056\/NEJMvcm044149","article-title":"Videos in clinical medicine. Placement of an arterial line","volume":"354","year":"2006","journal-title":"N Engl J Med"},{"issue":"12","key":"bib9-20230908","doi-asserted-by":"crossref","first-page":"1795","DOI":"10.1007\/s00134-014-3525-z","article-title":"Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine","volume":"40","year":"2014","journal-title":"Intensive Care Med"},{"issue":"6","key":"bib10-20230908","doi-asserted-by":"crossref","first-page":"553","DOI":"10.1111\/j.1365-2044.1995.tb06052.x","article-title":"Comparison of direct blood pressure measurement at the radial and dorsalis pedis arteries during surgery in the horizontal and reverse Trendelenburg positions","volume":"50","year":"1995","journal-title":"Anaesthesia"},{"issue":"6","key":"bib11-20230908","doi-asserted-by":"crossref","first-page":"103","DOI":"10.4037\/ccn1996.16.6.103","article-title":"Where should the transducer be leveled for radial or femoral arterial pressure monitoring?","volume":"16","year":"1996","journal-title":"Crit Care Nurse"},{"issue":"1","key":"bib12-20230908","first-page":"66","article-title":"Arterial blood pressure measurement technique","volume":"4","year":"1993","journal-title":"AACN Clin Issues Crit Care Nurs"},{"issue":"39","key":"bib13-20230908","doi-asserted-by":"crossref","first-page":"e1557","DOI":"10.1097\/MD.0000000000001557","article-title":"Modalities of invasive arterial pressure monitoring in critically ill patients: a prospective observational study","volume":"94","year":"2015","journal-title":"Medicine"},{"key":"bib14-20230908","doi-asserted-by":"crossref","first-page":"e162","DOI":"10.1093\/cid\/cir257","article-title":"Guidelines for the prevention of intravascular catheter-related infections","volume":"52","year":"2011","journal-title":"Clin Infect Dis"},{"issue":"6","key":"bib15-20230908","doi-asserted-by":"crossref","first-page":"1763","DOI":"10.1213\/ANE.0b013e3181bbd416","article-title":"Radial artery cannulation: a comprehensive review of recent anatomic and physiologic investigations","volume":"109","year":"2009","journal-title":"Anesth Analg"},{"issue":"3","key":"bib16-20230908","doi-asserted-by":"crossref","first-page":"460","DOI":"10.1177\/0310057X1204000311","article-title":"Cyanoacrylate tissue adhesives\u2014effective securement technique for intravascular catheters: in vitro testing of safety and feasibility","volume":"40","year":"2012","journal-title":"Anaesth Intensive Care"},{"issue":"1","key":"bib17-20230908","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/00129804-200601000-00007","article-title":"Why are we stuck on tape and suture? A review of catheter securement devices","volume":"29","year":"2006","journal-title":"J Infus Nurs"},{"issue":"1","key":"bib18-20230908","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1177\/0310057X0203000111","article-title":"Incidents relating to arterial cannulation as identified in 7,525 reports submitted to the Australian Incident Monitoring Study (AIMS\u2014ICU)","volume":"30","year":"2002","journal-title":"Anaesth Intensive Care"},{"issue":"2","key":"bib19-20230908","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1097\/01376517-199904000-00004","article-title":"Factors that contribute to complications during intrahospital transport of the critically ill","volume":"31","year":"1999","journal-title":"J Neurosci Nurs"},{"issue":"8","key":"bib20-20230908","doi-asserted-by":"crossref","first-page":"448","DOI":"10.4103\/0972-5229.188190","article-title":"Complications and benefits of intrahospital transport of adult intensive care unit patients","volume":"20","year":"2016","journal-title":"Indian J Crit Care Med"},{"issue":"2","key":"bib21-20230908","first-page":"47","article-title":"Frequency of adverse events during the hygiene of the critical care patient","volume":"13","year":"2002","journal-title":"Enferm Intensiva"},{"key":"bib25-20230908","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.ijnurstu.2016.11.007","article-title":"Devices and dressings to secure peripheral venous catheters: a Cochrane systematic review and meta-analysis","volume":"67","year":"2017","journal-title":"Int J Nurs Stud"},{"issue":"4","key":"bib26-20230908","doi-asserted-by":"crossref","first-page":"388","DOI":"10.1001\/jama.2017.19163","article-title":"Preferred Reporting Items for a Systematic Review and Meta-analysis of diagnostic test accuracy studies: the PRISMA-DTA statement","volume":"319","year":"2018","journal-title":"JAMA"},{"issue":"2","key":"bib27-20230908","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1136\/ebmed-2014-110158","article-title":"Mixed kinds of evidence: synthesis designs and critical appraisal for systematic mixed studies reviews including qualitative, quantitative and mixed methods studies","volume":"20","year":"2015","journal-title":"Evid Based Med"},{"key":"bib28-20230908","doi-asserted-by":"crossref","first-page":"d5928","DOI":"10.1136\/bmj.d5928","article-title":"The Cochrane Collaboration's tool for assessing risk of bias in randomised trials","volume":"343","year":"2011","journal-title":"BMJ"},{"issue":"3","key":"bib29-20230908","doi-asserted-by":"crossref","first-page":"123","DOI":"10.15171\/ijhpm.2014.71","article-title":"The development of a critical appraisal tool for use in systematic reviews addressing questions of prevalence","volume":"3","year":"2014","journal-title":"Int J Health Policy Manag"},{"issue":"3","key":"bib30-20230908","first-page":"175","article-title":"A pilot trial of bordered polyurethane dressings, tissue adhesive and sutureless devices compared with standard polyurethane dressings for securing short-term arterial catheters","volume":"16","year":"2014","journal-title":"Crit Care Resusc"},{"issue":"3","key":"bib31-20230908","doi-asserted-by":"crossref","first-page":"140","DOI":"10.1016\/j.aucc.2014.12.001","article-title":"Novel technologies can provide effective dressing and securement for peripheral arterial catheters: a pilot randomised controlled trial in the operating theatre and the intensive care unit","volume":"28","year":"2015","journal-title":"Aust Crit Care"},{"issue":"1","key":"bib32-20230908","first-page":"61","article-title":"A randomised controlled trial to determine the effectiveness of a radial arterial catheter dressing","volume":"20","year":"2018","journal-title":"Crit Care Resusc"},{"issue":"11","key":"bib33-20230908","doi-asserted-by":"crossref","first-page":"1753","DOI":"10.1007\/s00134-016-4582-2","article-title":"Complications of intravascular catheters in ICU: definitions, incidence and severity. A randomized controlled trial comparing usual transparent dressings versus new-generation dressings (the ADVANCED study)","volume":"42","year":"2016","journal-title":"Intensive Care Med"},{"issue":"3","key":"bib34-20230908","doi-asserted-by":"crossref","first-page":"130","DOI":"10.2309\/java.10-3-8","article-title":"The advantages of a precision-engineered securement device for fixation of arterial pressure-monitoring catheters","volume":"10","year":"2005","journal-title":"JAVA"},{"issue":"5","key":"bib35-20230908","doi-asserted-by":"crossref","first-page":"e1331","DOI":"10.1542\/peds.2015-1507","article-title":"Complications of central venous access devices: a systematic review","volume":"136","year":"2015","journal-title":"Pediatrics"},{"issue":"2","key":"bib36-20230908","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1097\/00003465-199403000-00005","article-title":"Veni-Gard versus standard dressings on hemodynamic catheter sites","volume":"13","year":"1994","journal-title":"Dimens Crit Care Nurs"},{"issue":"19","key":"bib37-20230908","doi-asserted-by":"crossref","first-page":"S4","DOI":"10.12968\/bjon.2017.26.19.S4","article-title":"Tissue adhesive for vascular access devices: who, what, where and when?","volume":"26","year":"2017","journal-title":"Br J Nurs"},{"issue":"6","key":"bib38-20230908","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1097\/NAN.0b013e3181f85be2","article-title":"A randomized controlled trial to compare the complications of 2 peripheral intravenous catheter-stabilization systems","volume":"33","year":"2010","journal-title":"J Infus Nurs"},{"issue":"4","key":"bib39-20230908","doi-asserted-by":"crossref","first-page":"371","DOI":"10.1097\/NCQ.0b013e318210741b","article-title":"Comparative safety and costs of transparent versus gauze wound dressings in intravenous catheterization","volume":"26","year":"2011","journal-title":"J Nurs Care Qual"},{"issue":"1","key":"bib40-20230908","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1097\/NHH.0000000000000481","article-title":"The 2016 infusion therapy standards of practice","volume":"35","year":"2017","journal-title":"Home Healthc Now"},{"issue":"5","key":"bib41-20230908","first-page":"345","article-title":"Practical tips for surgical research: blinding: who, what, when, why, how?","volume":"53","year":"2010","journal-title":"Can J Surg"},{"issue":"2","key":"bib42-20230908","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.java.2015.03.001","article-title":"Examining the role of securement and dressing products to prevent central venous access device failure: a narrative review","volume":"20","year":"2015","journal-title":"JAVA"},{"issue":"3","key":"bib43-20230908","doi-asserted-by":"crossref","first-page":"411","DOI":"10.1007\/s00134-010-2092-1","article-title":"Interpretation of blood pressure signal: physiological bases, clinical relevance, and objectives during shock states","volume":"37","year":"2011","journal-title":"Intensive Care Med"},{"issue":"4","key":"bib44-20230908","doi-asserted-by":"crossref","first-page":"225","DOI":"10.1097\/00129804-200607000-00009","article-title":"Summary of product trials for 10, 164 patients: comparing an intravenous stabilizing device to tape","volume":"29","year":"2006","journal-title":"J Infus Nurs"},{"issue":"4","key":"bib45-20230908","doi-asserted-by":"crossref","first-page":"45","DOI":"10.2309\/1552-8855-8.4.45","article-title":"Improving short peripheral IV outcomes: a clinical trial of two securement methods","volume":"8","year":"2003","journal-title":"JAVA"}],"container-title":["Dimensions of Critical Care Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000433","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,9,8]],"date-time":"2023-09-08T07:43:03Z","timestamp":1694158983000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000433"}},"subtitle":["A Systematic Review"],"short-title":[],"issued":{"date-parts":[[2020,9]]},"references-count":42,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020]]}},"URL":"https:\/\/doi.org\/10.1097\/dcc.0000000000000433","relation":{},"ISSN":["1538-8646","0730-4625"],"issn-type":[{"value":"1538-8646","type":"electronic"},{"value":"0730-4625","type":"print"}],"subject":[],"published":{"date-parts":[[2020,9]]}}}