{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,1]],"date-time":"2025-10-01T15:57:01Z","timestamp":1759334221784,"version":"build-2065373602"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"6","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Dimens Crit Care Nurs"],"published-print":{"date-parts":[[2025,11]]},"abstract":"<jats:sec>\n            <jats:title>Background<\/jats:title>\n            <jats:p>Conjugated hyperbilirubinemia, characterized by elevated levels of direct bilirubin (DB) may indicate underlying hepatobiliary disorders, such as biliary atresia, and warrants further investigation.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Objectives<\/jats:title>\n            <jats:p>The aim of this study was to accurately measure jaundice, related to DB levels, in newborn infants using an artificial intelligence (AI)\u2013based computer vision tool.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method<\/jats:title>\n            <jats:p>The computer vision tool used data processing, color transformations, and contrast enhancement techniques. Additionally, a convolutional neural network was created to predict DB levels. The study included 80 infants for training and validation and 17 infants for retesting. Five photographs were taken from the face, neck-chest, abdomen, extremities, and back after blood was drawn to measure DB levels. The photographs were captured using a professional camera under white light in the neonatal intensive care unit. Data analysis involved calculating the margin of error, percentage margin of error, and correlation statistics.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results<\/jats:title>\n            <jats:p>The retest findings were analyzed to determine the margins of error. The study revealed a 5.24% discrepancy between the AI-based computer vision tool and the DB values obtained from laboratory blood tests. Furthermore, a positive correlation was observed between patient blood values and the mean calculated by the AI system.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Discussion<\/jats:title>\n            <jats:p>This study concluded that DB measurements, conducted under appropriate conditions, were accurately determined using AI with a good level of precision. Subsequent research on total bilirubin is recommended.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/dcc.0000000000000729","type":"journal-article","created":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T12:12:24Z","timestamp":1759234344000},"page":"E1-E7","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Computer Vision\u2013Based Artificial Intelligence Tool for Direct Bilirubin Jaundice Measurement in Newborns"],"prefix":"10.1097","volume":"44","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5493-6507","authenticated-orcid":false,"given":"Suat","family":"Tuncay","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2775-3163","authenticated-orcid":false,"given":"G\u00fcrkan","family":"\u00d6zden","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5081-4593","authenticated-orcid":false,"given":"Abdullah","family":"Sarman","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2419-4845","authenticated-orcid":false,"given":"Fatma","family":"G\u00fcd\u00fcc\u00fc T\u00fcfekci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"bib1-20250930","first-page":"104810","article-title":"Evaluation of newborn hyperbilirubinemia and jaundice in primary care settings","year":"2023","journal-title":"J Nurse Pract"},{"issue":"7","key":"bib2-20250930","doi-asserted-by":"crossref","first-page":"1192","DOI":"10.3390\/children10071192","article-title":"Indirect neonatal hyperbilirubinemia and the role of fenofibrate as an adjuvant to phototherapy","volume":"10","year":"2023","journal-title":"Child"},{"issue":"5","key":"bib3-20250930","doi-asserted-by":"crossref","first-page":"e298","DOI":"10.1542\/neo.21-5-e298","article-title":"Pathogenesis and management of indirect hyperbilirubinemia in preterm neonates less than 35 weeks: moving toward a standardized approach","volume":"21","year":"2020","journal-title":"Neoreviews"},{"issue":"6","key":"bib6-20250930","doi-asserted-by":"crossref","first-page":"4460","DOI":"10.1039\/D2CP03733E","article-title":"Noninvasive, continuous fluorescence monitoring of bilirubin photodegradation","volume":"25","year":"2023","journal-title":"Phys Chem Chem Phys"},{"issue":"1","key":"bib7-20250930","doi-asserted-by":"crossref","first-page":"e000202","DOI":"10.1136\/bmjpo-2017-000202","article-title":"Direct bilirubin levels observed in prolonged neonatal jaundice: a retrospective cohort study","volume":"2","year":"2018","journal-title":"BMJ Paediatr Open"},{"issue":"3","key":"bib8-20250930","doi-asserted-by":"crossref","first-page":"e20170312","DOI":"10.1542\/peds.2017-0312","article-title":"Use of a smartphone app to assess neonatal jaundice","volume":"140","year":"2017","journal-title":"Pediatrics"},{"key":"bib10-20250930","doi-asserted-by":"crossref","first-page":"1321","DOI":"10.1016\/j.procs.2023.01.111","article-title":"Non-invasive early diagnosis of jaundice with computer vision","volume":"218","year":"2023","journal-title":"Proc Comput Sci"},{"issue":"21","key":"bib11-20250930","doi-asserted-by":"crossref","first-page":"7038","DOI":"10.3390\/s21217038","article-title":"Neonatal jaundice diagnosis using a smartphone camera based on eye, skin, and fused features with transfer learning","volume":"21","year":"2021","journal-title":"Sensors (Basel)"},{"issue":"21","key":"bib12-20250930","doi-asserted-by":"crossref","first-page":"3313","DOI":"10.3390\/diagnostics13213313","article-title":"Detection and classification of melanoma skin cancer using \u0131mage processing technique","volume":"13","year":"2023","journal-title":"Diagnostics (Basel)"},{"key":"bib13-20250930","doi-asserted-by":"crossref","first-page":"109341","DOI":"10.1016\/j.compbiomed.2024.109341","article-title":"Transfer learning in spirometry: CNN models for automated flow-volume curve quality control in paediatric populations","volume":"184","year":"2025","journal-title":"Comput Biol Med"},{"key":"bib14-20250930","doi-asserted-by":"crossref","first-page":"108018","DOI":"10.1016\/j.compbiomed.2024.108018","article-title":"Automatic data augmentation to improve generalization of deep learning in H&E stained histopathology","volume":"170","year":"2024","journal-title":"Comput Biol Med"},{"issue":"1","key":"bib15-20250930","doi-asserted-by":"crossref","first-page":"100235","DOI":"10.1016\/j.ynirp.2025.100235","article-title":"Enhancing precision in multiple sclerosis lesion segmentation: a U-net based machine learning approach with data augmentation","volume":"5","year":"2025","journal-title":"NeuroImage Rep"},{"issue":"1","key":"bib16-20250930","doi-asserted-by":"crossref","first-page":"6481","DOI":"10.1038\/s41598-025-89528-6","article-title":"Feasibility study of texture-based machine learning approach for early detection of neonatal jaundice","volume":"15","year":"2025","journal-title":"Sci Rep"},{"issue":"7","key":"bib17-20250930","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1007\/s10916-016-0523-4","article-title":"Neonatal jaundice detection system","volume":"40","year":"2016","journal-title":"J Med Syst"},{"key":"bib18-20250930","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.neucom.2012.10.034","article-title":"New newborn jaundice monitoring scheme based on combination of pre-processing and color detection method","volume":"120","year":"2013","journal-title":"Neurocomputing"},{"issue":"4","key":"bib19-20250930","doi-asserted-by":"crossref","first-page":"63","DOI":"10.3390\/designs5040063","article-title":"Neonatal jaundice detection using a computer vision system","volume":"5","year":"2021","journal-title":"Designs"},{"issue":"3","key":"bib20-20250930","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1111\/1467-8721.ep10768783","article-title":"Statistical power analysis","volume":"1","year":"1992","journal-title":"Curr Dir Psychol Sci"},{"key":"bib23-20250930","doi-asserted-by":"crossref","first-page":"1130229","DOI":"10.3389\/fonc.2023.1130229","article-title":"Common statistical concepts in the supervised machine learning arena","volume":"13","year":"2023","journal-title":"Front Oncol"},{"issue":"2","key":"bib24-20250930","doi-asserted-by":"crossref","first-page":"285","DOI":"10.18203\/2349-3291.ijcp20175928","article-title":"The smart phone study: assessing the reliability and accuracy of neonatal jaundice measurement using smart phone application","volume":"5","year":"2018","journal-title":"Int J Contemp Pediatr"},{"issue":"Suppl 1","key":"bib25-20250930","first-page":"S172","article-title":"Turkish neonatal society guideline to the approach, follow-up, and treatment of neonatal jaundice","volume":"53","year":"2018","journal-title":"Turk Pediatr Ars"},{"issue":"8","key":"bib26-20250930","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1542\/pir.32.8.341","article-title":"Hyperbilirubinemia in the newborn","volume":"32","year":"2011","journal-title":"Pediatr Rev"}],"container-title":["Dimensions of Critical Care Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000729","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T12:12:38Z","timestamp":1759234358000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000729"}},"subtitle":["A Pilot Study"],"short-title":[],"issued":{"date-parts":[[2025,11]]},"references-count":21,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/dcc.0000000000000729","relation":{},"ISSN":["1538-8646","0730-4625"],"issn-type":[{"type":"electronic","value":"1538-8646"},{"type":"print","value":"0730-4625"}],"subject":[],"published":{"date-parts":[[2025,11]]},"assertion":[{"value":"2024-07-10","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2025-07-23","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}