{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T18:25:00Z","timestamp":1790447100879,"version":"4.1.0"},"reference-count":24,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","license":[{"start":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T00:00:00Z","timestamp":1779926400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"name":"University of Massachusetts Amherst Provost Interdisciplinary Research Grant Award and Association for the Advancement of Medical Instrumentation (AAMI) Mary Logan Grant."}],"content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Frequent intravenous smart-pump (IVSP) alarms can disrupt workflow, increase alarm fatigue, and threaten patient safety.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To describe the frequency, distribution, and care-area variation of IVSP alarms from the Baxter Sigma Spectrum IVSP over a 2-year period at a large academic medical center.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>A retrospective study of IVSP alarms was performed for all inpatient areas at a US academic medical center. Alarm events and infusion starts were extracted using the Care Everywhere analytics platform and aggregated by frequency of alarms, number of infusions, alarm type, and care area. Analyses were done using descriptive statistics.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>A total of 5,129,505 alarms were linked to 1,102,303 infusion starts (mean = 4.65 alarms per infusion). Four alarm categories accounted for 86.5% of events: downstream occlusion (42.5%), air-in-line (15.5%), infusion complete (14.4%), and upstream occlusion (14.1%). Although they accounted for only 6% of total infusion starts, the NICU, pediatrics, and pediatric intensive care unit (PICU) had the highest alarm rates, averaging 28.6, 9.0, and 7.7 alarms per infusion, respectively. Downstream occlusion rates peaked in Pediatrics (696\/100 starts) and PICU (536\/100), while upstream occlusions were highest in the NICU (337\/100). Air-in-line alarms were greatest in Oncology (103\/100).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>Downstream occlusion, air-in-line, infusion-complete, and upstream occlusion alarms dominated the 2 years of alarm data, generating the majority of the 5 million IVSP alarms. Although adult medical-surgical (Med\/Surg) and critical care generated the most alarms overall, pediatric and neonatal areas experienced the highest number of alarms per infusion, placing them at the greatest risk for alarm fatigue.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/dcc.0000000000000764","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T17:00:09Z","timestamp":1779987609000},"page":"197-203","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":2,"title":["Intravenous Smart Pump Alarms in Everyday Hospital Use: A Real-world Descriptive Analysis"],"prefix":"10.1097","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0603-137X","authenticated-orcid":false,"given":"Brenda Abena","family":"Nyarko","sequence":"first","affiliation":[{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"},{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Nursing Research and Holistic, Baystate Health, Springfield, MA, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2753-2683","authenticated-orcid":false,"given":"Cidalia J.","family":"Vital","sequence":"additional","affiliation":[{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"},{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Nursing Research and Holistic, Baystate Health, Springfield, MA, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"},{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Nursing Research and Holistic, Baystate Health, Springfield, MA, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3047-5421","authenticated-orcid":false,"given":"Karen K.","family":"Giuliano","sequence":"additional","affiliation":[{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"},{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Nursing Research and Holistic, Baystate Health, Springfield, MA, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"},{"name":"Elaine Marieb Center for Nursing and Engineering Innovation, University of Massachusetts Amherst, Nursing Research and Holistic, Baystate Health, Springfield, MA, Elaine Marieb College of Nursing, University of Massachusetts Amherst, MA, USA"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"issue":"4","key":"R1-20260528","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1002\/nop2.1227","article-title":"A qualitative analysis of intravenous smart pump usability","volume":"9","author":"Blake","year":"2022","journal-title":"Nurs Open"},{"issue":"6","key":"R2-20260528","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1542\/hpeds.2023-007385","article-title":"Optimizing the use of dose error reduction software on intravenous infusion pumps","volume":"14","author":"Hughes","year":"2024","journal-title":"Hosp Pediatr"},{"issue":"1","key":"R3-20260528","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1186\/s12911-019-0945-2","article-title":"Smart pumps improve medication safety but increase alert burden in neonatal care","volume":"19","author":"Melton","year":"2019","journal-title":"BMC Med Inform Decis Mak"},{"key":"R5-20260528","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1097\/NAN.0000000000000532","article-title":"Infusion therapy standards of practice","volume":"47","author":"Nickel","year":"2024","journal-title":"J Infus Nurs"},{"issue":"16","key":"R6-20260528","doi-asserted-by":"crossref","first-page":"1203","DOI":"10.2146\/ajhp180151","article-title":"ASHP national survey of pharmacy practice in hospital settings: dispensing and administration-2017","volume":"75","author":"Schneider","year":"2018","journal-title":"Am J Health-Syst Pharm AJHP"},{"issue":"1","key":"R8-20260528","doi-asserted-by":"crossref","first-page":"e30","DOI":"10.1093\/ajhp\/zxad245","article-title":"Data-based program management of system-wide IV smart pump integration","volume":"81","author":"Giuliano","year":"2024","journal-title":"Am J Health Syst Pharm"},{"issue":"12","key":"R9-20260528","doi-asserted-by":"crossref","first-page":"1074","DOI":"10.1093\/ajhp\/zxab120","article-title":"ASHP national survey of pharmacy practice in hospital settings: dispensing and administration\u20142020","volume":"78","author":"Pedersen","year":"2021","journal-title":"Am J Health Syst Pharm"},{"issue":"17","key":"R10-20260528","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1093\/ajhp\/zxaa115","article-title":"Investigating multiple sources of data for smart infusion pump and electronic health record interoperability","volume":"77","author":"Marwitz","year":"2020","journal-title":"Am J Health Syst Pharm"},{"key":"R11-20260528","doi-asserted-by":"crossref","first-page":"2985","DOI":"10.1111\/jocn.16479","article-title":"The effect of educational interventions in managing nurses\u2019 alarm fatigue: an integrative review","volume":"32","author":"Nyarko","year":"2022","journal-title":"J Clin Nurs"},{"issue":"3","key":"R12-20260528","doi-asserted-by":"crossref","first-page":"e14123","DOI":"10.2196\/14123","article-title":"Types and frequency of infusion pump alarms and infusion-interruption to infusion-recovery times for critical short half-life infusions: retrospective data analysis","volume":"6","author":"Waterson","year":"2019","journal-title":"JMIR Hum Factors"},{"issue":"6","key":"R13-20260528","doi-asserted-by":"crossref","first-page":"433","DOI":"10.2345\/0899-8205-52.6.433","article-title":"Frequency and duration of infusion pump alarms: establishing national benchmarks","volume":"52","author":"Vitoux","year":"2018","journal-title":"Biomed Instrum Technol"},{"key":"R14-20260528","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1097\/PTS.0000000000001427","article-title":"Evaluating quality and safety during the administration of IV infusion during real-world IV smart pump use","volume":"22","author":"Vital","year":"2025","journal-title":"J Patient Saf"},{"issue":"1","key":"R15-20260528","doi-asserted-by":"crossref","first-page":"295","DOI":"10.1186\/s12911-021-01668-7","article-title":"Multi-infusion with integrated multiple pressure sensing allows earlier detection of line occlusions","volume":"21","author":"Doesburg","year":"2021","journal-title":"BMC Med Inform Decis Mak"},{"issue":"8","key":"R16-20260528","doi-asserted-by":"crossref","first-page":"S12","DOI":"10.12968\/bjon.2012.21.Sup5.S12","article-title":"Analysis of infusion pump error logs and their significance for health care","volume":"21","author":"Lee","year":"2012","journal-title":"Br J Nurs"},{"key":"R17-20260528","article-title":"Baxter Healthcare Corporation recalls SIGMA spectrum infusion pumps with master drug library and spectrum IQ infusion systems with dose IQ safety software for repeat upstream occlusion false alarms","year":"2023","journal-title":"FDA"},{"issue":"3","key":"R18-20260528","doi-asserted-by":"crossref","first-page":"252","DOI":"10.4037\/aacnacc2025136","article-title":"Beyond monitors: intravenous smart pump alarm fatigue as a safety concern","volume":"36","author":"Nyarko","year":"2025","journal-title":"AACN Adv Crit Care"},{"issue":"4","key":"R19-20260528","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1093\/ajhp\/zxaf233","article-title":"Evaluating IV smart pump infusions and alarms in health systems across the United States","volume":"83","author":"Armistead","year":"2026","journal-title":"Am J Health-Syst Pharm AJHP Off J Am Soc Health-Syst Pharm"},{"issue":"6","key":"R22-20260528","first-page":"500","article-title":"Incidence and causes of infusion alarms in a neonatal and pediatric intensive care unit: a prospective pilot study","volume":"25","author":"Fonzo-Christe","year":"2020","journal-title":"J Pediatr Pharmacol Ther JPPT"},{"issue":"8","key":"R23-20260528","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1002\/phar.2153","article-title":"Strategies for managing smart pump alarm and alert fatigue: a narrative review","volume":"38","author":"Shah","year":"2018","journal-title":"Pharmacotherapy"},{"key":"R24-20260528","article-title":"Beep, beep, repeat: the trouble with intravenous pump alarms","author":"Meade","year":"2025","journal-title":"Amn Assoc Crit Care Nurses Blog"},{"issue":"2","key":"R26-20260528","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1310\/hpj5002-113","article-title":"Optimizing smart pump technology by increasing critical safety alerts and reducing clinically insignificant alerts","volume":"50","author":"Mansfield","year":"2015","journal-title":"Hosp Pharm"},{"issue":"2","key":"R27-20260528","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.cnc.2018.02.004","article-title":"Intravenous smart pumps: usability issues, intravenous medication administration error, and patient safety","volume":"30","author":"Giuliano","year":"2018","journal-title":"Crit Care Nurs Clin North Am"},{"issue":"2","key":"R29-20260528","first-page":"209","article-title":"Air-in-line alarms: decreasing alarms through antisiphon valve implementation","volume":"23","author":"Meade","year":"2019","journal-title":"Clin J Oncol Nurs"},{"issue":"3","key":"R30-20260528","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1055\/s-0041-1730031","article-title":"Quantifying the impact of infusion alerts and alarms on nursing workflows: a retrospective analysis","volume":"12","author":"Yu","year":"2021","journal-title":"Appl Clin Inform"}],"container-title":["Dimensions of Critical Care Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000764","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T17:00:12Z","timestamp":1779987612000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000764"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":24,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/dcc.0000000000000764","relation":{},"ISSN":["0730-4625","1538-8646"],"issn-type":[{"value":"0730-4625","type":"print"},{"value":"1538-8646","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"assertion":[{"value":"2025-09-05","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-03-09","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}