{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T19:20:23Z","timestamp":1783106423563,"version":"3.54.6"},"reference-count":34,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"4","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2026,7]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>The recommendations to leave the lights on or turn the lights off before testing the pupillary light reflex (PLR) are primarily based on historical precedent. There is a lack of evidence to determine the best practice regarding adjusting ambient light when obtaining pupil measurements using a quantitative pupillometer (QP).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives:<\/jats:title>\n                    <jats:p>To examine the difference in QP measurements taken from the same subject in bright light versus in a darkened room.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Method:<\/jats:title>\n                    <jats:p>Before the human subject study, light readings were obtained with a lux meter to identify the range and central tendency for light in an intensive care unit. A set of 4, paired-sample within-subjects QP measurements was obtained in alternating bright and dark rooms.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Among 32 healthy volunteers, we found neither statistical nor clinically relevant differences in the neurological pupil index score in paired observations (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .12) taken in bright light [mean = 561.5 (37.3) lux] or dark conditions [mean = 0.9 (0.3) lux]. This remained true in a mixed model controlling for repeated observations (\n                      <jats:italic toggle=\"yes\">P<\/jats:italic>\n                      = .25).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Discussion:<\/jats:title>\n                    <jats:p>Pupil size was larger in dark conditions. But the finding that the pupillary light reflex functions normally despite fluctuating light levels is not unexpected.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion:<\/jats:title>\n                    <jats:p>The evidence does not support a need for nurses to adjust light levels before measuring the PLR with a pupillometer.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/dcc.0000000000000775","type":"journal-article","created":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T17:00:07Z","timestamp":1779987607000},"page":"204-208","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":1,"title":["Quantitative Pupillometry Values Are Similar in Bright Light and Dim Light Conditions"],"prefix":"10.1097","volume":"45","author":[{"given":"Kylie","family":"MacLean Hall","sequence":"first","affiliation":[{"name":"Texas Woman\u2019s University, Denton"},{"name":"Department of Neurology, The University of Texas Southwestern Medical Center, Dallas, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4027-8130","authenticated-orcid":false,"given":"Jennifer","family":"Wilson","sequence":"additional","affiliation":[{"name":"Texas Woman\u2019s University, Denton"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0005-2914-5742","authenticated-orcid":false,"given":"Ty A.","family":"Johnson","sequence":"additional","affiliation":[{"name":"Department of Neurology, The University of Texas Southwestern Medical Center, Dallas, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2454-1751","authenticated-orcid":false,"given":"Abdulkadir","family":"Kamal","sequence":"additional","affiliation":[{"name":"Department of Neurology, The University of Texas Southwestern Medical Center, Dallas, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9280-078X","authenticated-orcid":false,"given":"DaiWai M.","family":"Olson","sequence":"additional","affiliation":[{"name":"Department of Neurology, The University of Texas Southwestern Medical Center, Dallas, TX"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,5,28]]},"reference":[{"issue":"9","key":"R1-20260528","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1016\/j.amjmed.2024.04.043","article-title":"Quantitative pupillometry: clinical applications for the internist","volume":"137","author":"Figueroa","year":"2024","journal-title":"Am J Med"},{"issue":"5","key":"R2-20260528","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1097\/DCC.0000000000000656","article-title":"Nursing interventions and intracranial pressure change in pediatric patients with severe traumatic brain injury","volume":"43","author":"Mielcarek","year":"2024","journal-title":"Dimens Crit Care Nurs"},{"issue":"9","key":"R3-20260528","first-page":"e28901","article-title":"Evaluating the reliability of neurological pupillary index as a prognostic measurement of neurological function in critical care patients","volume":"14","author":"Ghauri","year":"2022","journal-title":"Cureus"},{"issue":"2","key":"R4-20260528","doi-asserted-by":"crossref","first-page":"251","DOI":"10.1007\/s12028-015-0182-1","article-title":"Interrater reliability of pupillary assessments","volume":"24","author":"Olson","year":"2016","journal-title":"Neurocrit Care"},{"issue":"24","key":"R5-20260528","doi-asserted-by":"crossref","first-page":"1112","DOI":"10.1212\/WNL.0000000000207740","article-title":"Pediatric and adult brain death\/death by neurologic criteria consensus guideline","volume":"101","author":"Greer","year":"2023","journal-title":"Neurology"},{"key":"R7-20260528","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1186\/s13054-016-1239-z","article-title":"Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study","volume":"20","author":"Couret","year":"2016","journal-title":"Crit Care"},{"issue":"3","key":"R8-20260528","doi-asserted-by":"crossref","first-page":"137","DOI":"10.1097\/DCC.0000000000000690","article-title":"Individual innovative features of the intensive care nurses","volume":"44","author":"Dayan","year":"2025","journal-title":"Dimens Crit Care Nurs"},{"key":"R9-20260528","doi-asserted-by":"crossref","first-page":"1363190","DOI":"10.3389\/fneur.2024.1363190","article-title":"Machine learning approach for ambient-light-corrected parameters and the Pupil Reactivity (PuRe) score in smartphone-based pupillometry","volume":"15","author":"Bogucki","year":"2024","journal-title":"Front Neurol"},{"issue":"2","key":"R10-20260528","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1097\/JNN.0000000000000818","article-title":"Neuroradiological correlates of abnormal pupillary light reflex findings among patients in the neuroscience intensive care unit","volume":"57","author":"Rana","year":"2025","journal-title":"J Neurosci Nurs"},{"issue":"2","key":"R11-20260528","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1167\/tvst.5.2.18","article-title":"Effects of age and sex on values obtained by RAPDx(\u00ae) pupillometer, and determined the standard values for detecting relative afferent pupillary defect","volume":"5","author":"Satou","year":"2016","journal-title":"Transl Vis Sci Technol"},{"issue":"1","key":"R12-20260528","doi-asserted-by":"crossref","first-page":"19","DOI":"10.3390\/diagnostics8010019","article-title":"Eyeing up the future of the pupillary light reflex in neurodiagnostics","volume":"8","author":"Hall","year":"2018","journal-title":"Diagnostics (Basel)"},{"issue":"12","key":"R13-20260528","doi-asserted-by":"crossref","first-page":"2415","DOI":"10.1038\/s41433-024-03151-9","article-title":"Basics, benefits, and pitfalls of pupillometers assessing visual function","volume":"38","author":"Philibert","year":"2024","journal-title":"Eye (Lond)"},{"issue":"3","key":"R14-20260528","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1097\/JNN.0000000000000501","article-title":"Characteristics of a brisk or sluggish pupillary light reflex: a nursing perspective","volume":"52","author":"Dance","year":"2020","journal-title":"J Neurosci Nurs"},{"issue":"1","key":"R15-20260528","doi-asserted-by":"crossref","first-page":"6992","DOI":"10.1038\/s41598-018-25477-7","article-title":"Understanding the relationship between the neurologic pupil index and constriction velocity values","volume":"8","author":"Shoyombo","year":"2018","journal-title":"Sci Rep"},{"issue":"1","key":"R16-20260528","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1186\/s12883-022-02801-3","article-title":"A differential of the left eye and right eye neurological pupil index is associated with discharge modified Rankin scores in neurologically injured patients","volume":"22","author":"Privitera","year":"2022","journal-title":"BMC Neurol"},{"issue":"1","key":"R17-20260528","doi-asserted-by":"crossref","first-page":"E125","DOI":"10.1055\/s-0041-1731074","article-title":"Automated infrared pupillometer use in assessing the neurological status in pediatric neurocritical care patients: case reports and literature review","volume":"11","author":"McGetrick","year":"2021","journal-title":"Rev J Child Sci"},{"issue":"1","key":"R18-20260528","doi-asserted-by":"crossref","first-page":"56","DOI":"10.1111\/aas.14327","article-title":"Pupillary dilation velocity is reduced in intensive care unit patients with septic shock","volume":"68","author":"Uhrenholt","year":"2024","journal-title":"Acta Anaesthesiol Scand"},{"issue":"6","key":"R19-20260528","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1097\/JNN.0000000000000478","article-title":"Distributions and reference ranges for automated pupillometer values in neurocritical care patients","volume":"51","author":"Lussier","year":"2019","journal-title":"J Neurosci Nurs"},{"key":"R20-20260528","doi-asserted-by":"crossref","first-page":"103757","DOI":"10.1016\/j.jbi.2021.103757","article-title":"Pupillary light reflex as a diagnostic aid from computational viewpoint: a systematic literature review","volume":"117","author":"Pinheiro","year":"2021","journal-title":"J Biomed Inform"},{"issue":"3","key":"R21-20260528","doi-asserted-by":"crossref","first-page":"352","DOI":"10.1001\/archopht.1958.00940040058007","article-title":"Electronic pupillography; a new instrument and some clinical applications","volume":"59","author":"Lowenstein","year":"1958","journal-title":"AMA Arch Ophthalmol"},{"issue":"7","key":"R22-20260528","doi-asserted-by":"crossref","first-page":"e0272303","DOI":"10.1371\/journal.pone.0272303","article-title":"Superior reproducibility and repeatability in automated quantitative pupillometry compared to standard manual assessment, and quantitative pupillary response parameters present high reliability in critically ill cardiac patients","volume":"17","author":"Nyholm","year":"2022","journal-title":"PLoS One"},{"issue":"1","key":"R23-20260528","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.cnc.2015.09.003","article-title":"The use of automated pupillometry in critical care","volume":"28","author":"Olson","year":"2016","journal-title":"Crit Care Nurs Clin North Am"},{"issue":"10","key":"R24-20260528","doi-asserted-by":"crossref","first-page":"71","DOI":"10.1007\/s11910-019-0994-z","article-title":"Automated pupillometry in neurocritical care: research and practice","volume":"19","author":"Lussier","year":"2019","journal-title":"Curr Neurol Neurosci Rep"},{"key":"R25-20260528","doi-asserted-by":"crossref","first-page":"82","DOI":"10.4103\/2152-7806.82248","article-title":"Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the Neurological Pupil index","volume":"2","author":"Chen","year":"2011","journal-title":"Surg Neurol Int"},{"issue":"1","key":"R26-20260528","first-page":"205","article-title":"Quantitative pupillometry, a new technology: normative data and preliminary observations in patients with acute head injury","volume":"98","author":"Taylor","year":"2003","journal-title":"Technical note J Neurosurg"},{"issue":"1","key":"R27-20260528","doi-asserted-by":"crossref","first-page":"21090","DOI":"10.1038\/s41598-021-00434-z","article-title":"A haploscope based binocular pupillometer system to quantify the dynamics of direct and consensual Pupillary Light Reflex","volume":"11","author":"Meethal","year":"2021","journal-title":"Sci Rep"},{"issue":"3","key":"R28-20260528","doi-asserted-by":"crossref","first-page":"1020","DOI":"10.1007\/s12028-024-02030-1","article-title":"Anisocoria after direct light stimulus is associated with poor outcomes following acute brain injury","volume":"41","author":"Doyle","year":"2024","journal-title":"Neurocrit Care"},{"key":"R29-20260528","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.jocn.2021.06.044","article-title":"Quantitative pupillometry in patients with traumatic brain injury and loss of consciousness: a prospective pilot study","volume":"91","author":"Traylor","year":"2021","journal-title":"J Clin Neurosci"},{"key":"R30-20260528","doi-asserted-by":"crossref","first-page":"e163","DOI":"10.1016\/j.wneu.2020.09.152","article-title":"Automated pupillometry as a triage and assessment tool in patients with traumatic brain injury","volume":"145","author":"El Ahmadieh","year":"2021","journal-title":"World Neurosurg"},{"issue":"5","key":"R31-20260528","doi-asserted-by":"crossref","first-page":"436","DOI":"10.1016\/j.aucc.2019.10.001","article-title":"Investigating the association between eye colour and the Neurological Pupil index","volume":"33","author":"Al-Obaidi","year":"2020","journal-title":"Aust Crit Care"},{"key":"R32-20260528","doi-asserted-by":"crossref","first-page":"111003","DOI":"10.1016\/j.jocn.2024.111003","article-title":"Quantitative pupillometry as a potential biomarker in early concussion assessment","volume":"132","author":"Bashir","year":"2025","journal-title":"J Clin Neurosci"},{"issue":"2","key":"R33-20260528","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1007\/s10877-017-0009-z","article-title":"Infrared pupillometry helps to detect and predict delirium in the post-anesthesia care unit","volume":"32","author":"Yang","year":"2018","journal-title":"J Clin Monit Comput"},{"issue":"2","key":"R34-20260528","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1007\/s12028-018-0607-8","article-title":"The effect of ambient light conditions on quantitative pupillometry","volume":"30","author":"Ong","year":"2019","journal-title":"Neurocrit Care"},{"key":"R35-20260528","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1007\/s10877-025-01293-z","article-title":"Is quantitative pupillometry affected by ambient light? A prospective crossover study","volume":"39","author":"Holmsk\u00e4r","year":"2025","journal-title":"J Clin Monit Comput"}],"container-title":["Dimensions of Critical Care Nursing"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000775","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,5,28]],"date-time":"2026-05-28T17:00:12Z","timestamp":1779987612000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/DCC.0000000000000775"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,5,28]]},"references-count":34,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2026]]}},"URL":"https:\/\/doi.org\/10.1097\/dcc.0000000000000775","relation":{},"ISSN":["0730-4625","1538-8646"],"issn-type":[{"value":"0730-4625","type":"print"},{"value":"1538-8646","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,5,28]]},"assertion":[{"value":"2025-11-26","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2026-04-30","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}