{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,23]],"date-time":"2026-10-23T13:24:49Z","timestamp":1792761889178,"version":"4.5.0"},"reference-count":62,"publisher":"SAGE Publications","issue":"5","license":[{"start":{"date-parts":[[2016,10,1]],"date-time":"2016-10-01T00:00:00Z","timestamp":1475280000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Dermatitis\u00ae"],"published-print":{"date-parts":[[2016,10,1]]},"abstract":"<jats:p>The American Contact Dermatitis Society recognizes the interest in the evaluation and management of metal hypersensitivity reactions. Given the paucity of robust evidence with which to guide our practices, we provide reasonable evidence and expert opinion\u2013based guidelines for clinicians with regard to metal hypersensitivity reaction testing and patient management. Routine preoperative evaluation in individuals with no history of adverse cutaneous reactions to metals or history of previous implant-related adverse events is not necessary. Patients with a clear self-reported history of metal reactions should be evaluated by patch testing before device implant. Patch testing is only 1 element in the assessment of causation in those with postimplantation morbidity. Metal exposure from the implanted device can cause sensitization, but a positive metal test does not prove symptom causality. The decision to replace an implanted device must include an assessment of all clinical factors and a thorough risk-benefit analysis by the treating physician(s) and patient.<\/jats:p>","DOI":"10.1097\/der.0000000000000210","type":"journal-article","created":{"date-parts":[[2016,9,20]],"date-time":"2016-09-20T07:12:50Z","timestamp":1474355570000},"page":"241-247","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":68,"title":["Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective from the American Contact Dermatitis Society"],"prefix":"10.1177","volume":"27","author":[{"given":"Peter C.","family":"Schalock","sequence":"first","affiliation":[{"name":"From the, *Department of Dermatology, Massachusetts General Hospital, Harvard School of Medicine, Boston"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Glen","family":"Crawford","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Pennsylvania, Philadelphia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Susan","family":"Nedorost","sequence":"additional","affiliation":[{"name":"University Hospitals Case Medical Center, Cleveland, OH"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pamela L.","family":"Scheinman","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Brigham and Women\u2019s Hospital, Harvard School of Medicine, Boston, MA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Amber Reck","family":"Atwater","sequence":"additional","affiliation":[{"name":"Duke Dermatology, Duke University Medical Center, Durham, NC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christen","family":"Mowad","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Geisinger Health System, Danville, PA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bruce","family":"Brod","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Pennsylvania, Philadelphia"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alison","family":"Ehrlich","sequence":"additional","affiliation":[{"name":"Department of Dermatology, George Washington University, Washington, DC"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kalman L.","family":"Watsky","sequence":"additional","affiliation":[{"name":"Yale University School of Medicine, New Haven, CT"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Denis","family":"Sasseville","sequence":"additional","affiliation":[{"name":"Division of Dermatology, McGill University Health Centre, Montr\u00e9al, Quebec, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dianne","family":"Silvestri","sequence":"additional","affiliation":[{"name":"Division of Dermatology, UMass Memorial Medical Center, Worcester"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sophie M.","family":"Worobec","sequence":"additional","affiliation":[{"name":"University of Illinois at Chicago"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John F.","family":"Elliott","sequence":"additional","affiliation":[{"name":"Division of Dermatology, Departments of Medicine and Medical Microbiology and Immunology, University of Alberta, Edmonton, Canada"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Golara","family":"Honari","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Stanford University, Palo Alto, CA"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Douglas L.","family":"Powell","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Utah, Salt Lake City"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Taylor","sequence":"additional","affiliation":[{"name":"Dermatology-Plastic Surgery Institute, Cleveland Clinic, OH"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Joel","family":"DeKoven","sequence":"additional","affiliation":[{"name":"Department of Medicine (Dermatology), University of Toronto, Ontario, Canada."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2016,10,1]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1002\/jat.3100"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.2106\/JBJS.L.00206"},{"issue":"111","key":"e_1_3_1_4_2","first-page":"407","article-title":"Hip and knee replacement in Germany and the USA: analysis of individual inpatient data from German and US hospitals for the years 2005 to 2011","volume":"9","author":"Wengler A","year":"2014","unstructured":"Wengler A, , Nimptsch U, , Mansky T. Hip and knee replacement in Germany and the USA: analysis of individual inpatient data from German and US hospitals for the years 2005 to 2011. Dtsch Arztebl Int, 2014; 9(111):407\u2013416.","journal-title":"Dtsch Arztebl Int"},{"issue":"2","key":"e_1_3_1_5_2","doi-asserted-by":"crossref","first-page":"e000435","DOI":"10.1136\/bmjopen-2011-000435","article-title":"What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patients","volume":"22","author":"Beswick AD","year":"2012","unstructured":"Beswick AD, , Wylde V, , Gooberman-Hill R, et al. What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patients. BMJ Open, 2012; 22(2):e000435.","journal-title":"BMJ Open"},{"key":"e_1_3_1_6_2","doi-asserted-by":"publisher","DOI":"10.1161\/CIRCULATIONAHA.106.173220"},{"key":"e_1_3_1_7_2","unstructured":"Dental implant facts and figures. Available at: http:\/\/www.aaid.com\/about\/Press_Room\/Dental_Implants_FAQ.html. Accessed April23 2016."},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.2310\/6620.2011.10055"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0000000000000097"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1398-9995.2009.01966.x"},{"key":"e_1_3_1_11_2","first-page":"257","article-title":"Sensitivity to implant materials in patients undergoing total hip replacement","volume":"77","author":"Granchi D","year":"2006","unstructured":"Granchi D, , Cenni E, , Trisolino G, et al. Sensitivity to implant materials in patients undergoing total hip replacement. Biomaterials, 2006; 77B:257\u2013264.","journal-title":"Biomaterials"},{"key":"e_1_3_1_12_2","doi-asserted-by":"publisher","DOI":"10.2106\/00004623-200103000-00017"},{"key":"e_1_3_1_13_2","doi-asserted-by":"crossref","first-page":"186","DOI":"10.5792\/ksrr.2013.25.4.186","article-title":"Metal allergy screening prior to joint arthroplasty and its influence on implant choice: a Delphi consensus study amongst orthopaedic arthroplasty surgeons","volume":"25","author":"Razak A","year":"2013","unstructured":"Razak A, , Ebinesan AD, , Charalambous CP. Metal allergy screening prior to joint arthroplasty and its influence on implant choice: a Delphi consensus study amongst orthopaedic arthroplasty surgeons. Knee Surg Relat Res, 2013; 25:186\u2013193.","journal-title":"Knee Surg Relat Res"},{"key":"e_1_3_1_14_2","doi-asserted-by":"publisher","DOI":"10.1159\/000371511"},{"key":"e_1_3_1_15_2","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/DER.0b013e3182a67d90","article-title":"Metal hypersensitivity reactions to implants: opinions and practices of patch testing dermatologists","volume":"24","author":"Schalock PC","year":"2013","unstructured":"Schalock PC, , Thyssen JP. Metal hypersensitivity reactions to implants: opinions and practices of patch testing dermatologists. Dermatitis, 2013; 24:313\u2013320.","journal-title":"Dermatitis"},{"key":"e_1_3_1_16_2","unstructured":"Waichman P. Nickel allergy may cause knee implant complications. Available at: http:\/\/www.yourlawyer.com\/articles\/title\/nickel-allergy-may-cause-knee-implant-complications. Accessed October15 2015."},{"key":"e_1_3_1_17_2","unstructured":"Hip & knee replacements. Available at: www.lawyersandsettlements.com\/lawsuit\/hip_and_knee_replacement_implant_failure.html#. Vh_9mfntlBc. Accessed October15 2015."},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1067\/mhj.2003.7"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12273"},{"key":"e_1_3_1_20_2","first-page":"373","article-title":"Revisiting Essure\u2014toward safe and effective sterilization","volume":"8","author":"Dhruva SS","year":"2015","unstructured":"Dhruva SS, , Ross JS, , Gariepy AM. Revisiting Essure\u2014toward safe and effective sterilization. N Engl J Med, 2015; 8:373\u2013e17.","journal-title":"N Engl J Med"},{"key":"e_1_3_1_21_2","unstructured":"FDA activities. September 2015 Advisory Committee to discuss Essure Safety and Effectiveness. FDA U.S. Food and Drug Administration. Available at: http:\/\/www.fda.gov\/MedicalDevices\/ProductsandMedicalProcedures\/ImplantsandProsthetics\/EssurePermanentBirthControl\/ucm452254.htm. Accessed March07 2016."},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1365-2133.2007.08119.x"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2008.01502.x"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2010.01857.x"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1097\/MCA.0b013e3283647ad1"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2008.01351.x"},{"key":"e_1_3_1_27_2","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1186\/1749-799X-3-6","article-title":"Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty","volume":"3","author":"Hallab NJ","year":"2008","unstructured":"Hallab NJ, , Caicedo M, , Finnegan A, et al. Th1 type lymphocyte reactivity to metals in patients with total hip arthroplasty. J Orthop Surg Res, 2008; 3:6.","journal-title":"J Orthop Surg Res"},{"key":"e_1_3_1_28_2","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1034\/j.1398-9995.2000.00619.x","article-title":"Intolerance of osteosynthesis material: evidence of dichromate contact allergy with concomitant oligoclonal T-cell infiltrate and TH1-type cytokine expression in the peri-implantar tissue","volume":"55","author":"Thomas P","year":"2000","unstructured":"Thomas P, , Summer B, , Sander CA, et al. Intolerance of osteosynthesis material: evidence of dichromate contact allergy with concomitant oligoclonal T-cell infiltrate and TH1-type cytokine expression in the peri-implantar tissue. Allergy, 2000; 55:969\u2013972.","journal-title":"Allergy"},{"key":"e_1_3_1_29_2","doi-asserted-by":"crossref","first-page":"910156","DOI":"10.1155\/2015\/910156","article-title":"Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology and peri-implant cytokine expression pattern","volume":"2015","author":"Thomas P","year":"2015","unstructured":"Thomas P, , von der Helm C, , Schopf C, et al. Patients with intolerance reactions to total knee replacement: combined assessment of allergy diagnostics, periprosthetic histology and peri-implant cytokine expression pattern. Biomed Res Int, 2015; 2015:910156.","journal-title":"Biomed Res Int"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1177\/1753425912451779"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.actbio.2014.02.003"},{"key":"e_1_3_1_32_2","first-page":"1","article-title":"The association between metal allergy, total knee arthroplasty, and revision: study based on the Danish Knee Arthroplasty Register","volume":"13","author":"M\u00fcnch HJ","year":"2015","unstructured":"M\u00fcnch HJ, , Jacobsen SS, , Olesen JT, et al. The association between metal allergy, total knee arthroplasty, and revision: study based on the Danish Knee Arthroplasty Register. Acta Orthop, 2015; 13:1\u20136.","journal-title":"Acta Orthop"},{"key":"e_1_3_1_33_2","doi-asserted-by":"crossref","first-page":"4","DOI":"10.1111\/j.1600-0536.2011.01971.x","article-title":"Hypersensitivity reactions to metallic implants \u2013 diagnostic algorithm and suggested patch test series for clinical use","volume":"66","author":"Schalock PC","year":"2012","unstructured":"Schalock PC, , Menn\u00e9 T, , Johansen J, et al. Hypersensitivity reactions to metallic implants \u2013 diagnostic algorithm and suggested patch test series for clinical use. Contact Dermatitis, 2012; 66:4\u201319.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_34_2","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1001\/archdermatol.2012.86","article-title":"Practice gap: the role of patch testing in the selection and management of metal device implants","volume":"148","author":"Mowad CM","year":"2012","unstructured":"Mowad CM. Practice gap: the role of patch testing in the selection and management of metal device implants. Arch Dermatol, 2012; 148:693\u2013694.","journal-title":"Arch Dermatol"},{"key":"e_1_3_1_35_2","doi-asserted-by":"publisher","DOI":"10.1001\/archdermatol.2011.2561"},{"key":"e_1_3_1_36_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2013.07.014"},{"key":"e_1_3_1_37_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0b013e31829cb113"},{"key":"e_1_3_1_38_2","doi-asserted-by":"crossref","first-page":"137287","DOI":"10.1155\/2015\/137287","article-title":"Biomaterial hypersensitivity: is it real? Supportive evidence and approach considerations for metal allergic patients following total knee arthroplasty","volume":"2015","author":"Mitchelson AJ","year":"2015","unstructured":"Mitchelson AJ, , Wilson CJ, , Mihalko WM, et al. Biomaterial hypersensitivity: is it real? Supportive evidence and approach considerations for metal allergic patients following total knee arthroplasty. Biomed Res Int, 2015; 2015:137287.","journal-title":"Biomed Res Int"},{"key":"e_1_3_1_39_2","doi-asserted-by":"crossref","first-page":"343","DOI":"10.1111\/cod.12465","article-title":"High frequency of contact allergy to implant and bone cement components, in particular gentamicin, in cemented arthroplasty with complications: usefulness of late patch test reading","volume":"73","author":"Thomas B","year":"2015","unstructured":"Thomas B, , Kulichova D, , Wolf R, et al. High frequency of contact allergy to implant and bone cement components, in particular gentamicin, in cemented arthroplasty with complications: usefulness of late patch test reading. Contact Dermatitis, 2015; 73:343\u2013349.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_40_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2011.01966.x"},{"key":"e_1_3_1_41_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0000000000000149"},{"key":"e_1_3_1_42_2","first-page":"905","article-title":"Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction? [in German]","volume":"44","author":"Thomas P","year":"2015","unstructured":"Thomas P, , Geier J, , Dickel H, et al. Should metal alloy discs be used for patch testing in suspected metal implant intolerance reaction? [in German]. Orthopade, 2015; 44:905\u2013908.","journal-title":"Orthopade"},{"key":"e_1_3_1_43_2","first-page":"311","article-title":"Hypersensitivity to titanium: clinical and laboratory evidence","volume":"27","author":"Muller KE","year":"2006","unstructured":"Muller KE, , Valentine-Thon E. Hypersensitivity to titanium: clinical and laboratory evidence. Neuro Endocrinol Lett, 2006; 27:311\u2013313.","journal-title":"Neuro Endocrinol Lett"},{"key":"e_1_3_1_44_2","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1002\/jbm.a.32368","article-title":"In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation","volume":"92","author":"Hallab NJ","year":"2010","unstructured":"Hallab NJ, , Epstein R, , McAllister K, et al. In vitro reactivity to implant metals demonstrates a person-dependent association with both T-cell and B-cell activation. J Biomed Mater Res A, 2010; 92:667\u2013682.","journal-title":"J Biomed Mater Res A"},{"key":"e_1_3_1_45_2","first-page":"200Y204","article-title":"Cobalt-induced occupational asthma associated with systemic illness","volume":"10","author":"Baik JJ","year":"1995","unstructured":"Baik JJ, , Yoon YB, , Park HS. Cobalt-induced occupational asthma associated with systemic illness. J Korean Med Sci, 1995; 10:200Y204.","journal-title":"J Korean Med Sci"},{"key":"e_1_3_1_46_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaci.2006.11.640"},{"key":"e_1_3_1_47_2","first-page":"129Y132","article-title":"Intradermal testing and sublingual desensitization for nickel","volume":"61","author":"Morris DL","year":"1998","unstructured":"Morris DL. Intradermal testing and sublingual desensitization for nickel. Cutis, 1998; 61:129Y132.","journal-title":"Cutis"},{"key":"e_1_3_1_48_2","first-page":"52","article-title":"Pacemaker dermatitis from titanium","volume":"42","author":"Yamauchi R","year":"2000","unstructured":"Yamauchi R, , Morita A, , Tsuji T. Pacemaker dermatitis from titanium. Contact Dermatitis, 2000; 42:52\u201353.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_49_2","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1111\/j.1600-0536.1993.tb04527.x","article-title":"Intradermal testing in the diagnosis of allergic contact dermatitis","volume":"29","author":"Herbst RA","year":"1993","unstructured":"Herbst RA, , Lauerma AI, , Maibach HI. Intradermal testing in the diagnosis of allergic contact dermatitis. A reappraisal. Contact Dermatitis, 1993; 29:1\u20135.","journal-title":"A reappraisal. Contact Dermatitis"},{"key":"e_1_3_1_50_2","first-page":"62","article-title":"Implantation of orthopaedic devices in patients with metal allergy","volume":"69","author":"Carlsson A","year":"1989","unstructured":"Carlsson A, , M\u00f6ller H. Implantation of orthopaedic devices in patients with metal allergy. Acta Derm Venereol, 1989; 69:62\u201366.","journal-title":"Acta Derm Venereol"},{"key":"e_1_3_1_51_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00167-012-2000-z"},{"key":"e_1_3_1_52_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00256-015-2264-8"},{"key":"e_1_3_1_53_2","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1111\/j.1600-0536.1979.tb04913.x","article-title":"Nickel sensitivity: relationship between history and patch test reaction","volume":"5","author":"Kieffer M","year":"1979","unstructured":"Kieffer M. Nickel sensitivity: relationship between history and patch test reaction. Contact Dermatitis, 1979; 5:398\u2013401.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_54_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2010.01702.x"},{"key":"e_1_3_1_55_2","doi-asserted-by":"crossref","first-page":"1042","DOI":"10.1001\/archderm.144.8.1042","article-title":"Thoughts on implants and contact allergy","volume":"144","author":"Bruze M","year":"2008","unstructured":"Bruze M. Thoughts on implants and contact allergy. Arch Dermatol, 2008; 144:1042\u20131044.","journal-title":"Arch Dermatol"},{"key":"e_1_3_1_56_2","first-page":"1553","article-title":"Dermatological views on orthopedic metal implants [in Swedish]","volume":"100","author":"M\u00f6ller H","year":"2003","unstructured":"M\u00f6ller H, , Lindberg M. Dermatological views on orthopedic metal implants [in Swedish]. Lakartidningen, 2003; 100:1553.","journal-title":"Lakartidningen"},{"key":"e_1_3_1_57_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00132-007-1183-3"},{"key":"e_1_3_1_58_2","first-page":"473","article-title":"Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery","volume":"164","author":"Thyssen JP","year":"2011","unstructured":"Thyssen JP, , Menn\u00e9 T, , Schalock PC, et al. Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery. Br J Dermatol, 2011; 164:473\u2013478.","journal-title":"Br J Dermatol"},{"key":"e_1_3_1_59_2","first-page":"327","article-title":"Allergic potential of titanium implants","volume":"34","author":"Schuh A","year":"2005","unstructured":"Schuh A, , Thomas P, , Kachler W, et al. Allergic potential of titanium implants. Orthopade, 2005; 34:327\u2013333.","journal-title":"Orthopade"},{"key":"e_1_3_1_60_2","unstructured":"Oxinum. Smith&Nephew. Available at: http:\/\/www.smith-nephew.com\/key-products\/orthopaedic-reconstruction\/oxinium-oxidized-zirconium\/. Accessed November16 2015."},{"key":"e_1_3_1_61_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jpedsurg.2006.09.056"},{"key":"e_1_3_1_62_2","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1016\/j.jaip.2015.07.011","article-title":"Allergy to surgical implants","volume":"3","author":"Pacheco KA","year":"2015","unstructured":"Pacheco KA. Allergy to surgical implants. J Allergy Clin Immunol Pract, 2015; 3:683\u2013695.","journal-title":"J Allergy Clin Immunol Pract"},{"key":"e_1_3_1_63_2","doi-asserted-by":"publisher","DOI":"10.3928\/01477447-20160119-06"}],"container-title":["Dermatitis\u00ae"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000210","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1097\/DER.0000000000000210","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000210","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:03:51Z","timestamp":1777399431000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.1097\/DER.0000000000000210"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10,1]]},"references-count":62,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2016,10,1]]}},"alternative-id":["10.1097\/DER.0000000000000210"],"URL":"https:\/\/doi.org\/10.1097\/der.0000000000000210","relation":{},"ISSN":["1710-3568","2162-5220"],"issn-type":[{"value":"1710-3568","type":"print"},{"value":"2162-5220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,10,1]]}}}