{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T13:06:00Z","timestamp":1777554360659,"version":"3.51.4"},"reference-count":18,"publisher":"SAGE Publications","issue":"2","license":[{"start":{"date-parts":[[2020,4,1]],"date-time":"2020-04-01T00:00:00Z","timestamp":1585699200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Dermatitis\u00ae"],"published-print":{"date-parts":[[2020,4,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>Allergic contact dermatitis to rubber accelerators in gloves has been well described in the literature. In response to this, glove manufacturers have recently marketed \u201caccelerator-free\u201d gloves. Little research has been done, to confirm whether these gloves are truly free from the accelerators known to cause contact dermatitis.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objective<\/jats:title>\n                    <jats:p>The aim of the study was to verify use of accelerators in reportedly accelerator-free\/low-dermatitis-potential gloves.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>A total of 16 commercially available medical gloves touted as \u201caccelerator-free,\u201d \u201csensitive,\u201d or \u201clow dermatitis potential\u201d were obtained and analyzed via mass spectrometry (liquid chromatography heated electrospray ionization tandem mass spectrometry and liquid chromatography heated electrospray high-resolution tandem mass spectrometry) to determine whether any of the 9 known rubber accelerators were present (thiurams, carbamates, mercaptobenzothiazole, and diphenylguanidine).<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results<\/jats:title>\n                    <jats:p>Despite marketing claims to the contrary, all tested gloves had at least 1 accelerant detected. Dipentamethylenethiuram disulfide, a thiuram, was found in all 16 gloves. Half of the gloves (8\/16) contained more than 1 accelerator, with 1 glove having 5 rubber accelerators present.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusion<\/jats:title>\n                    <jats:p>Patients with allergic contact dermatitis to accelerators should be aware potentially sensitizing accelerators may be present in gloves that are reported to not contain them.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/der.0000000000000508","type":"journal-article","created":{"date-parts":[[2020,3,12]],"date-time":"2020-03-12T23:12:53Z","timestamp":1584054773000},"page":"128-133","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":3,"title":["Are Rubber Gloves Marketed as Accelerator-Free Truly Free of Accelerators? [RETRACTED]"],"prefix":"10.1177","volume":"31","author":[{"given":"Makenzie E.","family":"Pillsbury","sequence":"first","affiliation":[{"name":"From the, *Masonic Cancer Center Mass Spectrometry Facility"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sanna","family":"Ronkainen","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Minnesota, Minneapolis"},{"name":"Washington Hospital Center, Georgetown University, DC"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Molly","family":"Goodier","sequence":"additional","affiliation":[{"name":"University of Minnesota Medical School"},{"name":"Department of Internal Medicine, University of Minnesota"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sara A.","family":"Hylwa","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Minnesota, Minneapolis"},{"name":"Park Nicollet Contact Dermatitis Clinic, Health Partners Institute"},{"name":"Department of Dermatology, Hennepin Healthcare, Minneapolis, MN."}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2020,4,1]]},"reference":[{"issue":"4","key":"e_1_3_2_2_2","first-page":"434","article-title":"Update on medical and surgical gloves","volume":"20","author":"Cleenewerck MB","year":"2010","unstructured":"Cleenewerck MB. Update on medical and surgical gloves. Eur J Dermatol, 2010; 20(4):434\u2013442.","journal-title":"Eur J Dermatol"},{"key":"e_1_3_2_3_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12356"},{"issue":"3","key":"e_1_3_2_4_2","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1111\/cod.12330","article-title":"Occupational contact allergy in nurses: results from the Information Network of Departments of Dermatology 2003\u20132012","volume":"72","author":"Molin S","year":"2015","unstructured":"Molin S, , Bauer A, , Schnuch A, et al. Occupational contact allergy in nurses: results from the Information Network of Departments of Dermatology 2003\u20132012. Contact Dermatitis, 2015; 72(3):164\u2013171.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_2_5_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12168"},{"key":"e_1_3_2_6_2","unstructured":"Jacobson E. Regulation of Natural Rubber Latex. March 25 1999. Available at: http:\/\/www.fda.gov\/NewsEvents\/Testimony\/ucm115083.htm. Accessed April12 2016."},{"key":"e_1_3_2_7_2","unstructured":"FDA Product Classification. Last update April 11 2016. Available at: http:\/\/www.accessdata.fda.gov\/scripts\/cdrh\/cfdocs\/cfpcd\/classification.cfm?start_search=1&Submission_Type_ID=&DeviceName=&ProductCode=&DeviceClass=1&ThirdParty=&Panel=&RegulationNumber=880.6250&PAGENUM=50. Accessed April12 2016."},{"key":"e_1_3_2_8_2","unstructured":"Gardner N. Accelerator-free fact or fiction: how accelerator-free are your gloves. Health and Safety International. October 2008. Available at: http:\/\/www.shieldscientific.com\/include\/USER_FileUpload\/files\/Press%20Release\/HSInt-Accelerator-free-%20gloves-Oct-08.pdf. Accessed April12 2016."},{"issue":"2","key":"e_1_3_2_9_2","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1111\/j.0105-1873.2005.00657.x","article-title":"Survey of sulfur-containing rubber accelerator levels in latex and nitrile exam gloves","volume":"53","author":"Depree GJ","year":"2005","unstructured":"Depree GJ, , Bledsoe TA, , Siegel PD. Survey of sulfur-containing rubber accelerator levels in latex and nitrile exam gloves. Contact Dermatitis, 2005; 53(2):107\u2013113.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_2_10_2","doi-asserted-by":"publisher","DOI":"10.1034\/j.1600-0536.2003.480107.x"},{"key":"e_1_3_2_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2012.02139.x"},{"key":"e_1_3_2_12_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0000000000000342"},{"key":"e_1_3_2_13_2","doi-asserted-by":"publisher","DOI":"10.2310\/6620.2010.09088"},{"issue":"1","key":"e_1_3_2_14_2","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1034\/j.1600-0536.2000.043001009.x","article-title":"Allergologically relevant rubber accelerators in single-use medical gloves","volume":"42","author":"Knudsen BB","year":"2000","unstructured":"Knudsen BB, , Hametner C, , Seycek O, et al. Allergologically relevant rubber accelerators in single-use medical gloves. Contact Dermatitis, 2000; 42(1):9\u201315.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_2_15_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0b013e318281d87b"},{"key":"e_1_3_2_16_2","unstructured":"Baseline allergens test. Available at: https:\/\/www.escd.org\/contact-dermatitis\/baseline-allergens-test\/. Accessed July31 2018."},{"key":"e_1_3_2_17_2","unstructured":"International Standard Series. Available at: https:\/\/www.chemotechnique.se\/products\/series\/international-standard-series\/. Accessed July31 2018."},{"key":"e_1_3_2_18_2","unstructured":"T.R.U.E. Test at Smart Practice Dermatology Allergy. Available at: https:\/\/www.smartpractice.com\/shop\/wa\/category?cn=Products-T.R.U.E.-TEST&id=581719&m=SPA. Accessed July31 2018."},{"key":"e_1_3_2_19_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12860"}],"updated-by":[{"DOI":"10.1097\/der.0000000000000608","type":"retraction","label":"Retraction","source":"retraction-watch","updated":{"date-parts":[[2020,5,1]],"date-time":"2020-05-01T00:00:00Z","timestamp":1588291200000},"record-id":"23123"}],"container-title":["Dermatitis\u00ae"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000508","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1097\/DER.0000000000000508","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000508","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:05:05Z","timestamp":1777399505000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.1097\/DER.0000000000000508"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,1]]},"references-count":18,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2020,4,1]]}},"alternative-id":["10.1097\/DER.0000000000000508"],"URL":"https:\/\/doi.org\/10.1097\/der.0000000000000508","relation":{},"ISSN":["1710-3568","2162-5220"],"issn-type":[{"value":"1710-3568","type":"print"},{"value":"2162-5220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,1]]}}}