{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,23]],"date-time":"2026-08-23T14:55:00Z","timestamp":1787496900488,"version":"build-2736575974"},"reference-count":48,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Dermatitis\u00ae"],"published-print":{"date-parts":[[2020,2,1]]},"abstract":"<jats:p>Multidisciplinary collaboration between several European dermatology departments has identified isobornyl acrylate (IBOA; CAS 5888-33-5), once deemed a low-risk sensitizer, as a major culprit contact allergen in glucose sensors and insulin pumps, medical devices used by diabetes patients worldwide. Although the patch test modalities of IBOA have been fairly well characterized, intriguing questions remain. For example, its cross-reactive profile to other acrylates remains to be determined, and the striking occurrence of concomitant positive patch test reactions to sesquiterpene lactones needs to be further elucidated. Importantly, the path to its discovery as a contact sensitizer in diabetes devices and the difficulties that were associated with this quest illustrate that apparent difficulties in obtaining sufficient cooperation from the medical device industry may seriously hamper the correct workup of cases of allergic contact dermatitis. The IBOA saga will convince companies to lend more cooperation to dermatologists and policymakers to side with patients and physicians when it comes to updating medical device regulations, including the compulsory labeling of medical devices in general and of diabetes devices in particular.<\/jats:p>","DOI":"10.1097\/der.0000000000000549","type":"journal-article","created":{"date-parts":[[2020,1,8]],"date-time":"2020-01-08T12:29:35Z","timestamp":1578486575000},"page":"4-12","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":55,"title":["Isobornyl Acrylate"],"prefix":"10.1177","volume":"31","author":[{"given":"Olivier","family":"Aerts","sequence":"first","affiliation":[{"name":"From the, *Department of Dermatology, University Hospital Antwerp (UZA) and University of Antwerp, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Herman","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Cliniques Universitaires Saint-Luc, Brussels, Belgium"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martin","family":"Mowitz","sequence":"additional","affiliation":[{"name":"Department of Occupational and Environmental Dermatology, Lund University, Sk\u00e5ne University Hospital, Malm\u00f6, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Magnus","family":"Bruze","sequence":"additional","affiliation":[{"name":"Department of Occupational and Environmental Dermatology, Lund University, Sk\u00e5ne University Hospital, Malm\u00f6, Sweden"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"An","family":"Goossens","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University Hospitals, KU Leuven, Belgium."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"179","published-online":{"date-parts":[[2020,2,1]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12866"},{"key":"e_1_3_1_3_2","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1111\/cod.13330","article-title":"Unexpected positive patch test reactions to sesquiterpene lactones in patients sensitized to the glucose sensor FreeStyle Libre","volume":"81","author":"Herman A","year":"2019","unstructured":"Herman A, , Mowitz M, , Aerts O, et al. Unexpected positive patch test reactions to sesquiterpene lactones in patients sensitized to the glucose sensor FreeStyle Libre. Contact Dermatitis, 2019; 81:354\u2013367.","journal-title":"Contact Dermatitis"},{"issue":"2","key":"e_1_3_1_4_2","first-page":"115","article-title":"Isobornyl acrylate: an impurity in alkyl glucosides","volume":"35","author":"Foti C","year":"2016","unstructured":"Foti C, , Romita P, , Rigano L, et al. Isobornyl acrylate: an impurity in alkyl glucosides. Cutan Ocul Toxicol, 2016; 35(2):115\u2013119.","journal-title":"Cutan Ocul Toxicol"},{"issue":"3","key":"e_1_3_1_5_2","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1111\/cod.13026","article-title":"Alkyl glucosides: newly identified allergens in foam wound dressings","volume":"79","author":"Kerre S","year":"2018","unstructured":"Kerre S, , Strobbe T, , Naessens T, et al. Alkyl glucosides: newly identified allergens in foam wound dressings. Contact Dermatitis, 2018; 79(3):191\u2013193.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_6_2","unstructured":"Material Safety Data Sheet (MSDS) of isobornyl acrylate. Available at: https:\/\/www.sigmaaldrich.com. Accessed July4 2019."},{"key":"e_1_3_1_7_2","doi-asserted-by":"crossref","first-page":"121","DOI":"10.1111\/j.0105-1873.2005.00527.x","article-title":"An epidemic of occupational contact dermatitis from an acrylic glue","volume":"52","author":"Kiec-Swierczynska M","year":"2005","unstructured":"Kiec-Swierczynska M, , Krecisz B, , Swierczynska-Machura D, et al. An epidemic of occupational contact dermatitis from an acrylic glue. Contact Dermatitis, 2005; 52:121\u2013125.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1995.tb00506.x"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12023"},{"key":"e_1_3_1_10_2","doi-asserted-by":"crossref","first-page":"340","DOI":"10.1111\/j.1600-0536.2008.01333.x","article-title":"Occupational methacrylate and acrylate allergy from glues","volume":"58","author":"Aalto-Korte K","year":"2008","unstructured":"Aalto-Korte K, , Alanko K, , Kuuliala O, et al. Occupational methacrylate and acrylate allergy from glues. Contact Dermatitis, 2008; 58:340\u2013346.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.1995.tb00554.x"},{"issue":"1","key":"e_1_3_1_12_2","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1034\/j.1600-0536.2001.045001047.x","article-title":"Sensitization to methyl methacrylate in the plastic catheter of an insulin pump infusion set","volume":"45","author":"Saccabusi S","year":"2001","unstructured":"Saccabusi S, , Boatto G, , Asproni B, et al. Sensitization to methyl methacrylate in the plastic catheter of an insulin pump infusion set. Contact Dermatitis, 2001; 45(1):47\u201348.","journal-title":"Contact Dermatitis"},{"issue":"1","key":"e_1_3_1_13_2","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1034\/j.1600-0536.2001.045001036.x","article-title":"Allergic contact dermatitis from phenoxyethoxy ethylacrylates in optical fiber coating, and glue in an insulin pump set","volume":"45","author":"Jolanki R","year":"2001","unstructured":"Jolanki R, , Kanerva L, , Estlander T, et al. Allergic contact dermatitis from phenoxyethoxy ethylacrylates in optical fiber coating, and glue in an insulin pump set. Contact Dermatitis, 2001; 45(1):36\u201337.","journal-title":"Contact Dermatitis"},{"issue":"2","key":"e_1_3_1_14_2","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1111\/j.1600-0536.1996.tb02305.x","article-title":"Allergic contact dermatitis from acrylates in insulin pump infusion sets","volume":"35","author":"van den Hove J","year":"1996","unstructured":"van den Hove J, , Jacobs MC, , Tennstedt D, et al. Allergic contact dermatitis from acrylates in insulin pump infusion sets. Contact Dermatitis, 1996; 35(2):108.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13120"},{"key":"e_1_3_1_16_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13248"},{"key":"e_1_3_1_17_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(17)30896-6"},{"key":"e_1_3_1_18_2","doi-asserted-by":"publisher","DOI":"10.1016\/S0140-6736(17)30893-0"},{"key":"e_1_3_1_19_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296818762946"},{"key":"e_1_3_1_20_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296816662949"},{"key":"e_1_3_1_21_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12503"},{"key":"e_1_3_1_22_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12873"},{"key":"e_1_3_1_23_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0000000000000281"},{"key":"e_1_3_1_24_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13075"},{"key":"e_1_3_1_25_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13337"},{"key":"e_1_3_1_26_2","doi-asserted-by":"publisher","DOI":"10.1111\/jdi.13023"},{"issue":"3","key":"e_1_3_1_27_2","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1111\/cod.13349","article-title":"Allergic contact dermatitis by isobornyl acrylate in glucose monitoring devices: report of two cases","volume":"81","author":"Jauregui I","year":"2019","unstructured":"Jauregui I, , Sanchez J, , Segurola A, et al. Allergic contact dermatitis by isobornyl acrylate in glucose monitoring devices: report of two cases. Contact Dermatitis, 2019; 81(3):219\u2013220.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_28_2","unstructured":"Available at: https:\/\/ansm.sante.fr\/S-informer\/Points-d-information-Points-d-information\/Mise-a-disposition-de-dispositifs-FreeStyle-Libre-avec-des-capteurs-modifies-Point-d-Information. Accessed June25 2019."},{"key":"e_1_3_1_29_2","article-title":"Prevalence and prevention of contact dermatitis caused by FreeStyle Libre: a monocentric experience","author":"Pyl J","unstructured":"Pyl J, , Dendooven E, , Van Eekelen I, et al. Prevalence and prevention of contact dermatitis caused by FreeStyle Libre: a monocentric experience. Submitted.","journal-title":"Submitted"},{"key":"e_1_3_1_30_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0088"},{"key":"e_1_3_1_31_2","doi-asserted-by":"publisher","DOI":"10.1111\/pedi.12652"},{"key":"e_1_3_1_32_2","unstructured":"Available at: https:\/\/abbott.mediaroom.com\/2019-02-21-New-Real-World-Evidence-Analysis-of-Nearly-Half-a-Million-FreeStyle-R-Libre-System-Users-Shows-Higher-Rates-of-Scanning-Improves-Glucose-Control. Accessed July20 2019."},{"key":"e_1_3_1_33_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12995"},{"key":"e_1_3_1_34_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13017"},{"key":"e_1_3_1_35_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13155"},{"issue":"6","key":"e_1_3_1_36_2","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1111\/cod.13360","article-title":"Induction of leukoderma following allergic contact dermatitis to FreeStyle Libre","volume":"81","author":"Herman A","year":"2019","unstructured":"Herman A, , de Montjoye L, , Marot L, et al. Induction of leukoderma following allergic contact dermatitis to FreeStyle Libre. Contact Dermatitis, 2019; 81(6):456\u2013458.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_37_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13243"},{"key":"e_1_3_1_38_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13239"},{"key":"e_1_3_1_39_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13012"},{"key":"e_1_3_1_40_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2018.0080"},{"key":"e_1_3_1_41_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13329"},{"key":"e_1_3_1_42_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12678"},{"key":"e_1_3_1_43_2","unstructured":"Medical Device Alert No. MDA\/2019\/003 of the Medicines & Healthcare products Regulatory Agency 2019. Available at: https:\/\/assets.publishing.service.gov.uk\/media\/5c4f35e1ed915d7d51fd5a35\/MDA-2019-003_Final13.pdf. Accessed June25 2019."},{"issue":"13","key":"e_1_3_1_44_2","doi-asserted-by":"crossref","first-page":"1286","DOI":"10.2340\/00015555-3256","article-title":"Patch testing with isobornyl acrylate in 16 Swedish patients with contact dermatitis from glucose sensors and\/or insulin pumps","volume":"99","author":"Mowitz M","year":"2019","unstructured":"Mowitz M, , Fornander L, , Hosseiny S, et al. Patch testing with isobornyl acrylate in 16 Swedish patients with contact dermatitis from glucose sensors and\/or insulin pumps. Acta Derm Venereol, 2019; 99(13):1286\u20131287.","journal-title":"Acta Derm Venereol"},{"key":"e_1_3_1_45_2","doi-asserted-by":"publisher","DOI":"10.1089\/dia.2019.0163"},{"key":"e_1_3_1_46_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13374"},{"key":"e_1_3_1_47_2","doi-asserted-by":"publisher","DOI":"10.1177\/1932296817738076"},{"key":"e_1_3_1_48_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.13354"},{"issue":"10103","key":"e_1_3_1_49_2","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1016\/S0140-6736(17)32142-6","article-title":"FreeStyle Libre: contact irritation versus contact allergy","volume":"390","author":"Aerts O","year":"2017","unstructured":"Aerts O, , Herman A, , Bruze M, et al. FreeStyle Libre: contact irritation versus contact allergy. Lancet, 2017; 390(10103):1644.","journal-title":"Lancet"}],"container-title":["Dermatitis\u00ae"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000549","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1097\/DER.0000000000000549","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000549","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:05:04Z","timestamp":1777399504000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.1097\/DER.0000000000000549"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,1]]},"references-count":48,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2,1]]}},"alternative-id":["10.1097\/DER.0000000000000549"],"URL":"https:\/\/doi.org\/10.1097\/der.0000000000000549","relation":{},"ISSN":["1710-3568","2162-5220"],"issn-type":[{"value":"1710-3568","type":"print"},{"value":"2162-5220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,1]]}}}