{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T13:05:58Z","timestamp":1777554358428,"version":"3.51.4"},"reference-count":14,"publisher":"SAGE Publications","issue":"1","license":[{"start":{"date-parts":[[2020,2,1]],"date-time":"2020-02-01T00:00:00Z","timestamp":1580515200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/journals.sagepub.com\/page\/policies\/text-and-data-mining-license"}],"content-domain":{"domain":["journals.sagepub.com"],"crossmark-restriction":true},"short-container-title":["Dermatitis\u00ae"],"published-print":{"date-parts":[[2020,2,1]]},"abstract":"<jats:sec>\n                    <jats:title>Background<\/jats:title>\n                    <jats:p>A major question in patch testing is when to perform the final reading. Our current standard practice is to place patches on day 1, remove them on day 3, and perform readings on days 3 and 5. For certain allergens, another reading is performed sometime from days 7 to 14\u2265.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Objectives<\/jats:title>\n                    <jats:p>The aim of the study was to identify allergens with positive reactions on day 5 that were negative on day 7 or later and allergens with negative reactions on day 5 that were subsequently positive on day 7 or later.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods<\/jats:title>\n                    <jats:p>We reviewed records of patients who underwent patch testing from January 2007 to December 2016 at Mayo Clinic with readings on day 5 and day 7 or later.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions<\/jats:title>\n                    <jats:p>In total, 131 allergens had positive reactions on day 5 that were negative on day 7 or later, and 58 allergens had negative reactions on day 5 that were positive on day 7 or later. Twenty-five allergens had significantly higher reaction rates on day 5 than day 7 or later. Our standard practice is to perform readings on days 3 and 5 and on days 3, 5, and 7 or later for series containing metals. Readings on days 3, 5, and 7 or later should also be considered for acrylates.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/der.0000000000000562","type":"journal-article","created":{"date-parts":[[2020,1,8]],"date-time":"2020-01-08T12:29:35Z","timestamp":1578486575000},"page":"42-52","update-policy":"https:\/\/doi.org\/10.1177\/sage-journals-update-policy","source":"Crossref","is-referenced-by-count":12,"title":["The Final Patch Test Read: Day 5 or Day &gt;7?"],"prefix":"10.1177","volume":"31","author":[{"given":"Hafsa M.","family":"Cantwell","sequence":"first","affiliation":[{"name":"From the, *Department of Dermatology, Mayo Clinic, Rochester, MN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Lisa A.","family":"Drage","sequence":"additional","affiliation":[{"name":"From the, *Department of Dermatology, Mayo Clinic, Rochester, MN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rokea A.","family":"el-Azhary","sequence":"additional","affiliation":[{"name":"From the, *Department of Dermatology, Mayo Clinic, Rochester, MN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthew R.","family":"Hall","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Mayo Clinic, Jacksonville, FL"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jill M.","family":"Killian","sequence":"additional","affiliation":[{"name":"Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, MN"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"James A.","family":"Yiannias","sequence":"additional","affiliation":[{"name":"Department of Dermatology, Mayo Clinic, Scottsdale, AZ."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mark D. P.","family":"Davis","sequence":"additional","affiliation":[{"name":"From the, *Department of Dermatology, Mayo Clinic, Rochester, MN"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"179","published-online":{"date-parts":[[2020,2,1]]},"reference":[{"key":"e_1_3_1_2_2","doi-asserted-by":"publisher","DOI":"10.1111\/cod.12432"},{"key":"e_1_3_1_3_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0b013e318277ca50"},{"key":"e_1_3_1_4_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0000000000000297"},{"key":"e_1_3_1_5_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0000000000000411"},{"issue":"5","key":"e_1_3_1_6_2","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1111\/j.0105-1873.2005.00705.x","article-title":"The development and course of patch-test reactions to 2-hydroxyethyl methacrylate and ethyleneglycol dimethacrylate","volume":"53","author":"Isaksson M","year":"2005","unstructured":"Isaksson M, , Lindberg M, , Sundberg K, et al. The development and course of patch-test reactions to 2-hydroxyethyl methacrylate and ethyleneglycol dimethacrylate. Contact Dermatitis, 2005; 53(5):292\u2013297.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_7_2","doi-asserted-by":"publisher","DOI":"10.1007\/s00784-013-1122-0"},{"key":"e_1_3_1_8_2","doi-asserted-by":"publisher","DOI":"10.2310\/derm.1.2005.2103"},{"key":"e_1_3_1_9_2","doi-asserted-by":"publisher","DOI":"10.1016\/j.jaad.2008.04.022"},{"key":"e_1_3_1_10_2","doi-asserted-by":"publisher","DOI":"10.1097\/DER.0b013e31829cb0d1"},{"key":"e_1_3_1_11_2","doi-asserted-by":"publisher","DOI":"10.1111\/j.1600-0536.2007.00959.x"},{"issue":"2","key":"e_1_3_1_12_2","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1111\/cod.12004","article-title":"Outcome of a second patch test reading of TRUE Tests\u00ae on D6\/7","volume":"68","author":"Madsen JT","year":"2013","unstructured":"Madsen JT, , Andersen KE. Outcome of a second patch test reading of TRUE Tests\u00ae on D6\/7. Contact Dermatitis, 2013; 68(2):94\u201397.","journal-title":"Contact Dermatitis"},{"issue":"4","key":"e_1_3_1_13_2","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1111\/j.1600-0536.2010.01855.x","article-title":"Late reactions to patch test preparations with reduced concentrations of p-phenylenediamine: a multicentre investigation of the German Contact Dermatitis Research Group","volume":"64","author":"Hillen U","year":"2011","unstructured":"Hillen U, , Dickel H, , Loffler H, et al. Late reactions to patch test preparations with reduced concentrations of p-phenylenediamine: a multicentre investigation of the German Contact Dermatitis Research Group. Contact Dermatitis, 2011; 64(4):196\u2013202.","journal-title":"Contact Dermatitis"},{"issue":"2","key":"e_1_3_1_14_2","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1111\/j.1600-0536.2007.01003.x","article-title":"Late reactions in patch tests: a 4-year review from a clinic of occupational dermatology","volume":"56","author":"Aalto-Korte K","year":"2007","unstructured":"Aalto-Korte K, , Alanko K, , Kuuliala O, et al. Late reactions in patch tests: a 4-year review from a clinic of occupational dermatology. Contact Dermatitis, 2007; 56(2):81\u201386.","journal-title":"Contact Dermatitis"},{"key":"e_1_3_1_15_2","doi-asserted-by":"publisher","DOI":"10.2310\/6620.2006.05020"}],"container-title":["Dermatitis\u00ae"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000562","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/full-xml\/10.1097\/DER.0000000000000562","content-type":"application\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/journals.sagepub.com\/doi\/pdf\/10.1097\/DER.0000000000000562","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,4,28]],"date-time":"2026-04-28T18:05:04Z","timestamp":1777399504000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.sagepub.com\/doi\/full\/10.1097\/DER.0000000000000562"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,2,1]]},"references-count":14,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2020,2,1]]}},"alternative-id":["10.1097\/DER.0000000000000562"],"URL":"https:\/\/doi.org\/10.1097\/der.0000000000000562","relation":{},"ISSN":["1710-3568","2162-5220"],"issn-type":[{"value":"1710-3568","type":"print"},{"value":"2162-5220","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,2,1]]}}}