{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,2]],"date-time":"2026-07-02T12:25:15Z","timestamp":1782995115608,"version":"3.54.5"},"reference-count":26,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"2","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Dermatol Surg","DS"],"published-print":{"date-parts":[[2018,2]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND<\/jats:title>\n            <jats:p>The injection of local anesthetic into the skin is often the only memorable event described by the patient after dermatologic procedures.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>OBJECTIVE<\/jats:title>\n            <jats:p>The authors compared the pain felt during injection of local anesthetic using a minimal needle insertion technique with a 30- or 33-gauge needle.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MATERIALS AND METHODS<\/jats:title>\n            <jats:p>Three hundred eighteen patients with tumors on the head and neck were injected with lidocaine using a previously described technique with either a 30- or 33-gauge needle. After injection, patients were surveyed using the visual assessment scale for pain.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS<\/jats:title>\n            <jats:p>Seventy-seven percent of patients felt no pain with injection on the face using a 33-gauge needle compared with 64% with a 30 gauge, whereas 94% of patients felt no pain on the scalp with a 33-gauge needle compared with 54% with a 30 gauge. Visual analog scale scores were also significantly decreased on the face and scalp using the smaller needle. There was no difference in pain between the 2 needles with injection on the neck.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION<\/jats:title>\n            <jats:p>This study further validates the use of this technique for the injection of lidocaine and the preference of a 33 gauge over a 30-gauge needle for the initial injection on the face and scalp.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/dss.0000000000001279","type":"journal-article","created":{"date-parts":[[2017,10,10]],"date-time":"2017-10-10T20:31:20Z","timestamp":1507667480000},"page":"204-208","source":"Crossref","is-referenced-by-count":14,"title":["Finer Needles Reduce Pain Associated With Injection of Local Anesthetic Using a Minimal Insertion Injection Technique"],"prefix":"10.1097","volume":"44","author":[{"given":"Blake R.","family":"Zelickson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Leonard H.","family":"Goldberg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Marc K.","family":"Rubenzik","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wesley J.","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20230814","doi-asserted-by":"crossref","first-page":"188","DOI":"10.1136\/emj.2003.012070","article-title":"A users guide for reducing the pain of local anaesthetic administration","volume":"22","author":"Quaba","year":"2005","journal-title":"Emerg Med J"},{"key":"R2-20230814","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1097\/PRS.0b013e31829ad1e2","article-title":"Minimizing the pain of local anesthesia injection","volume":"132","author":"Strazar","year":"2013","journal-title":"Plast Reconstr Surg"},{"key":"R3-20230814","doi-asserted-by":"crossref","first-page":"676","DOI":"10.1097\/00006534-198311000-00017","article-title":"Minimizing the pain of local anesthesia","volume":"72","author":"Arndt","year":"1983","journal-title":"Plast Reconstr Surg"},{"key":"R4-20230814","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1111\/j.1473-2165.2010.00503.x","article-title":"The evidence for reducing the pain of administration of local anesthesia and cosmetic injectables","volume":"9","author":"Babamiri","year":"2010","journal-title":"J Cosmet Dermatol"},{"key":"R5-20230814","first-page":"CD006581","article-title":"Adjusting the pH of lidocaine for reducing pain on injection","author":"Cepeda","year":"2010","journal-title":"Cochrane Database Syst Rev"},{"key":"R6-20230814","doi-asserted-by":"crossref","first-page":"122","DOI":"10.1097\/AAP.0b013e31819a12a6","article-title":"Efficacy of bicarbonate in decreasing pain on intradermal injection of local anesthetics: a meta-analysis","volume":"34","author":"Hanna","year":"2009","journal-title":"Reg Anesth Pain Med"},{"key":"R7-20230814","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/S0735-6757(98)90126-7","article-title":"Pain reduction in lidocaine administration through buffering and warming","volume":"16","author":"Colaric","year":"1998","journal-title":"Am J Emerg Med"},{"key":"R8-20230814","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1016\/j.annemergmed.2010.12.001","article-title":"Systematic review and meta-analysis of the effect of warming local anesthetics on injection pain","volume":"58","author":"Hogan","year":"2011","journal-title":"Ann Emerg Med"},{"key":"R9-20230814","doi-asserted-by":"crossref","first-page":"926","DOI":"10.1111\/j.1399-6576.1998.tb05351.x","article-title":"Slow injection of local anaesthetic will decrease pain during dorsal penile nerve block","volume":"42","author":"Serour","year":"1998","journal-title":"Acta Anaesthesiol Scand"},{"key":"R10-20230814","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1016\/S0196-0644(98)70278-1","article-title":"Pain of local anesthetics: rate of administration and buffering","volume":"31","author":"Scarfone","year":"1998","journal-title":"Ann Emerg Med"},{"key":"R11-20230814","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1007\/s11552-012-9478-1","article-title":"Decreasing the pain of finger block injection: level II evidence","volume":"8","author":"Hamelin","year":"2013","journal-title":"Hand (N Y)"},{"key":"R12-20230814","doi-asserted-by":"crossref","first-page":"7","DOI":"10.3109\/2000656X.2015.1058269","article-title":"The influence of injection speed on pain during injection of local anaesthetic","volume":"50","author":"Tangen","year":"2016","journal-title":"J Plast Surg Hand Surg"},{"key":"R13-20230814","doi-asserted-by":"crossref","first-page":"1032","DOI":"10.1111\/j.1553-2712.1997.tb03675.x","article-title":"The effect of injection speed on the pain of lidocaine infiltration","volume":"4","author":"Krause","year":"1997","journal-title":"Acad Emerg Med"},{"key":"R14-20230814","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1080\/08990220600700925","article-title":"Pain following controlled cutaneous insertion of needles with different diameters","volume":"23","author":"Arendt-Nielsen","year":"2006","journal-title":"Somatosens Mot Res"},{"key":"R15-20230814","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1016\/J.JHSB.2005.06.021","article-title":"The use of a fine-gauge needle to reduce pain in open carpal tunnel decompression: a randomized controlled trial","volume":"30","author":"Watts","year":"2005","journal-title":"J Hand Surg Br"},{"key":"R16-20230814","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1213\/00000539-199802000-00030","article-title":"The effect of needle gauge and lidocaine pH on pain during intradermal injection","volume":"86","author":"Palmon","year":"1998","journal-title":"Anesth Analg"},{"key":"R17-20230814","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1177\/193229680700100517","article-title":"Does needle size matter?","volume":"1","author":"Gill","year":"2007","journal-title":"J Diabetes Sci Technol"},{"key":"R18-20230814","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/S1090-3801(99)90187-8","article-title":"Pain and mechanical injury of human skin following needle insertions","volume":"3","author":"Egekvist","year":"1999","journal-title":"Eur J Pain"},{"key":"R19-20230814","doi-asserted-by":"crossref","first-page":"115","DOI":"10.3109\/2000656X.2015.1111223","article-title":"The importance of needle gauge for pain during injection of lidocaine","volume":"50","author":"Wago","year":"2016","journal-title":"J Plast Surg Hand Surg"},{"key":"R20-20230814","doi-asserted-by":"crossref","first-page":"1231","DOI":"10.1016\/j.jaad.2011.04.011","article-title":"A randomized controlled crossover trial: lidocaine injected at a 90-degree angle causes less pain than lidocaine injected at a 45-degree angle","volume":"65","author":"Martires","year":"2011","journal-title":"J Am Acad Dermatol"},{"key":"R21-20230814","first-page":"517","article-title":"Tumescent technique for local anesthesia","volume":"164","author":"Klein","year":"1996","journal-title":"West J Med"},{"key":"R22-20230814","doi-asserted-by":"crossref","first-page":"757","DOI":"10.1177\/1090820X14532941","article-title":"The effect of microneedle thickness on pain during minimally invasive facial procedures: a clinical study","volume":"34","author":"Sezgin","year":"2014","journal-title":"Aesthet Surg J"},{"key":"R23-20230814","doi-asserted-by":"crossref","first-page":"1194","DOI":"10.1001\/jamadermatol.2015.2232","article-title":"Effect of needle size on pain perception in patients treated with botulinum toxin type A injections: a randomized clinical trial","volume":"151","author":"Alam","year":"2015","journal-title":"JAMA Dermatol"},{"key":"R24-20230814","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1111\/j.1524-4725.2009.01391.x","article-title":"Needle preference in patients receiving cosmetic botulinum toxin type A","volume":"36","author":"Price","year":"2010","journal-title":"Dermatol Surg"},{"key":"R25-20230814","doi-asserted-by":"crossref","first-page":"376","DOI":"10.1097\/IOP.0b013e3181b1e526","article-title":"Comparison of pain scores with 30-gauge and 32-gauge needles for periocular botulinum toxin type A injections","volume":"25","author":"Yomtoob","year":"2009","journal-title":"Ophthal Plast Reconstr Surg"},{"key":"R26-20230814","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1016\/j.jaad.2017.03.007","article-title":"Parallel, minimal needle-insertion technique for achieving a painless injection of local anesthetic","volume":"77","author":"Zelickson","year":"2017","journal-title":"J Am Acad Dermatol"}],"container-title":["Dermatologic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/00042728-201802000-00009","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,8,14]],"date-time":"2023-08-14T19:34:11Z","timestamp":1692041651000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00042728-201802000-00009"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/dss.0000000000001279","relation":{},"ISSN":["1076-0512","1524-4725"],"issn-type":[{"value":"1076-0512","type":"print"},{"value":"1524-4725","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,2]]}}}