{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T09:13:17Z","timestamp":1785402797151,"version":"3.56.0"},"reference-count":41,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Dermatol Surg","DS"],"published-print":{"date-parts":[[2025,3]]},"abstract":"<jats:sec>\n            <jats:title>BACKGROUND<\/jats:title>\n            <jats:p>Thread lifting, a minimally invasive alternative to facial rhytidectomy, has shifted from using nonabsorbable to absorbable sutures. Although many thread lift options exist, the impact of these different properties on complication rates remains unclear.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>OBJECTIVE<\/jats:title>\n            <jats:p>To systematically compare thread lift complication rates across different suture materials, textures, fixation methods, and lift locations.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>MATERIALS\/METHODS<\/jats:title>\n            <jats:p>A systematic review was conducted through February 2024, following PRISMA guidelines, using multiple databases. The study focused on absorbable sutures, excluding nonabsorbable materials. Statistical analysis used Chi-Square tests with Bonferroni correction.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>RESULTS<\/jats:title>\n            <jats:p>Nineteen studies, encompassing 1,406 patients, met inclusion criteria. A total of 876 complications were reported. Ecchymosis (19.49%), swelling (16.79%), and tenderness (9.96%) were the most frequent complications, while hematoma (0.64%), paresthesia (1.14%), and infection (2.49%) were least frequent. Complications varied significantly among the studied factors. Swelling and ecchymosis were more associated with polycaprolactone sutures, barbed threads, and midface lifts. Barbed threads were associated with more complications than smooth or coned threads, as were floating threads compared with fixed threads.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>CONCLUSION<\/jats:title>\n            <jats:p>Variations in thread lift suture materials and fixation technique were associated with different complication rates. Thread lifts using absorbable sutures exhibited complication rates under 5%, suggesting a generally favorable safety profile.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/dss.0000000000004466","type":"journal-article","created":{"date-parts":[[2024,10,23]],"date-time":"2024-10-23T21:00:35Z","timestamp":1729717235000},"page":"272-276","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":6,"title":["An Assessment and Comparison of Adverse Effect Rates in Differing Absorbable Thread Lift Suture Materials"],"prefix":"10.1097","volume":"51","author":[{"given":"Avaneesh Sean","family":"Ojha","sequence":"first","affiliation":[{"name":"University of Central Florida College of Medicine, Orlando, Florida;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Navid","family":"Farahbakhsh","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Florida, Gainesville, Florida;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sami K.","family":"Saikaly","sequence":"additional","affiliation":[{"name":"Department of Dermatology, University of Florida, Gainesville, Florida;"},{"name":"Rising Sun Dermatology, PLLC, St. Augustine, Florida"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2024,10,23]]},"reference":[{"key":"R2-20250228","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1007\/s00266-020-02095-1","article-title":"Percutaneous thread lift facial rejuvenation: literature review and evidence-based analysis","volume":"45","author":"Atiyeh","year":"2021","journal-title":"Aesthet Plast Surg"},{"key":"R3-20250228","first-page":"103","article-title":"Outcomes in thread lift for facial rejuvenation: a study performed with happy LiftTM revitalizing","volume":"4","author":"Savoia","year":"2014","journal-title":"Dermatol Ther (Heidelb)"},{"key":"R4-20250228","doi-asserted-by":"crossref","first-page":"160","DOI":"10.14730\/aaps.2014.20.3.160","article-title":"Combined, minimally invasive, thread-based facelift","volume":"20","author":"Han","year":"2014","journal-title":"Arch Aesthet Plast Surg"},{"key":"R5-20250228","doi-asserted-by":"crossref","first-page":"521","DOI":"10.5999\/aps.2015.42.5.521","article-title":"Development of facial rejuvenation procedures: thirty years of clinical experience with face lifts","volume":"42","author":"Kim","year":"2015","journal-title":"Arch Plast Surg"},{"key":"R7-20250228","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1111\/j.1524-4725.2009.01442.x","article-title":"Incidence of complications and early recurrence in 29 patients after facial rejuvenation with barbed suture lifting","volume":"36","author":"Rachel","year":"2010","journal-title":"Dermatol Surg"},{"key":"R8-20250228","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1097\/00042728-200503000-00020","article-title":"A case of Aptos thread migration and partial expulsion","volume":"31","author":"Silva-Siwady","year":"2005","journal-title":"Dermatol Surg"},{"issue":"suppl","key":"R9-20250228","first-page":"S93","article-title":"Use of barbed threads in facial rejuvenation","volume":"41","author":"Kalra","year":"2008","journal-title":"Indian J Plast Surg"},{"key":"R10-20250228","doi-asserted-by":"crossref","first-page":"178","DOI":"10.1001\/archfaci.2009.10","article-title":"Thread-lift for facial rejuvenation: assessment of long-term results","volume":"11","author":"Abraham","year":"2009","journal-title":"Arch Facial Plast Surg"},{"key":"R11-20250228","doi-asserted-by":"crossref","first-page":"1307","DOI":"10.1007\/s00266-012-9975-1","article-title":"Successful treatment of thread-lifting complication from APTOS sutures using a simple MACS lift and fat grafting","volume":"36","author":"Sapountzis","year":"2012","journal-title":"Aesthet Plast Surg"},{"key":"R12-20250228","doi-asserted-by":"crossref","first-page":"2148","DOI":"10.1007\/s00266-021-02256-w","article-title":"A meta-analysis and systematic review of the incidences of complications following facial thread-lifting","volume":"45","author":"Niu","year":"2021","journal-title":"Aesthet Plast Surg"},{"key":"R13-20250228","doi-asserted-by":"crossref","first-page":"159e","DOI":"10.1097\/PRS.0000000000008012","article-title":"Treatment of complications following facial thread-lifting","volume":"148","author":"Chen","year":"2021","journal-title":"Plast Reconstr Surg"},{"key":"R14-20250228","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/j.joms.2019.11.011","article-title":"Thread-lift sutures: anatomy, technique, and review of current literature","volume":"78","author":"Halepas","year":"2020","journal-title":"J Oral Maxillofac Surg"},{"key":"R15-20250228","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1055\/s-0040-1714266","article-title":"Use of polydioxanone threads as an alternative in nonsurgical procedures in facial rejuvenation","volume":"36","author":"Cobo","year":"2020","journal-title":"Facial Plast Surg"},{"key":"R16-20250228","first-page":"74","article-title":"Poly (\u220a-caprolactone) fiber: an overview","volume":"9","author":"Azimi","year":"2014","journal-title":"J engineered fibers fabrics"},{"key":"R17-20250228","doi-asserted-by":"crossref","first-page":"2743","DOI":"10.1111\/jocd.13883","article-title":"Efficacy study of the new polycaprolactone thread compared with other commercialized threads in a murine model","volume":"20","author":"Cho","year":"2021","journal-title":"J Cosmet Dermatol"},{"key":"R18-20250228","doi-asserted-by":"crossref","DOI":"10.15406\/jdc.2017.01.00021","article-title":"Hanging by a thread: choosing the right thread for the right patient","volume":"1","author":"Wong","year":"2017","journal-title":"J Dermatol Cosmetol"},{"key":"R19-20250228","doi-asserted-by":"crossref","first-page":"296","DOI":"10.1055\/s-0042-1748641","article-title":"A new complex minimally invasive thread lift method for one-time three-step fixation of the face and neck soft tissues","volume":"49","author":"Zhukova","year":"2022","journal-title":"Arch Plast Surg"},{"key":"R20-20250228","doi-asserted-by":"crossref","first-page":"511","DOI":"10.1001\/jamafacial.2018.0747","article-title":"Technique for nonsurgical lifting procedures using polydioxanone threads","volume":"20","author":"Karimi","year":"2018","journal-title":"JAMA Facial Plast Surg"},{"key":"R21-20250228","doi-asserted-by":"crossref","first-page":"e467","DOI":"10.1097\/SCS.0000000000005644","article-title":"Complication after PDO threads lift","volume":"30","author":"Ahn","year":"2019","journal-title":"J Craniofac Surg"},{"key":"R22-20250228","doi-asserted-by":"crossref","first-page":"e2775","DOI":"10.1097\/GOX.0000000000002775","article-title":"Short-term treatment outcomes of facial rejuvenation using the mint lift fine","volume":"8","author":"Moon","year":"2020","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R23-20250228","doi-asserted-by":"crossref","first-page":"e2045","DOI":"10.1097\/GOX.0000000000002045","article-title":"An innovative thread-looping method for facial rejuvenation: minimal access multiple plane suspension","volume":"7","author":"Wang","year":"2019","journal-title":"Plast Reconstr Surg - Glob Open"},{"key":"R24-20250228","doi-asserted-by":"crossref","first-page":"1395","DOI":"10.1007\/s13555-021-00569-x","article-title":"Absorbable barbed threads for lower facial soft-tissue repositioning in Asians","volume":"11","author":"Wanitphakdeedecha","year":"2021","journal-title":"Dermatol Ther (Heidelb)"},{"key":"R25-20250228","doi-asserted-by":"crossref","first-page":"52","DOI":"10.14730\/aaps.2018.01550","article-title":"Minimally invasive facial rejuvenation combining thread lifting with liposuction: a clinical comparison with thread lifting alone","volume":"25","author":"Bae","year":"2019","journal-title":"Arch Aesthet Plast Surg"},{"key":"R26-20250228","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1093\/asj\/sjy042","article-title":"Effectiveness, longevity, and complications of facelift by barbed suture insertion","volume":"39","author":"Bertossi","year":"2019","journal-title":"Aesthet Surg J"},{"key":"R27-20250228","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1080\/14764172.2018.1427875","article-title":"Improving mandibular contour: a pilot study for indication of PPLA traction thread use","volume":"20","author":"Guida","year":"2018","journal-title":"J Cosmet Laser Ther"},{"key":"R28-20250228","doi-asserted-by":"crossref","first-page":"1263","DOI":"10.1097\/DSS.0000000000001169","article-title":"Vertical lifting: a new optimal thread lifting technique for asians","volume":"43","author":"Kang","year":"2017","journal-title":"Dermatol Surg"},{"key":"R29-20250228","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1080\/14764172.2017.1400167","article-title":"Outcome of facial rejuvenation with polydioxanone thread for Asians","volume":"20","author":"Lee","year":"2018","journal-title":"J Cosmet Laser Ther"},{"key":"R30-20250228","first-page":"18","article-title":"Facial lift and patient satisfaction following treatment with absorbable suspension sutures: 12-month data from a prospective, masked, controlled clinical study","volume":"12","author":"Nestor","year":"2019","journal-title":"J Clin Aesthet Dermatol"},{"key":"R31-20250228","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1007\/s00266-020-01919-4","article-title":"Maximizing thread usage for facial rejuvenation: a preliminary patient study","volume":"45","author":"Park","year":"2021","journal-title":"Aesthet Plast Surg"},{"key":"R32-20250228","doi-asserted-by":"crossref","first-page":"1189","DOI":"10.1111\/jocd.12519","article-title":"Safety and complications of absorbable threads made of poly-L-lactic acid and poly lactide\/glycolide: experience with 148 consecutive patients","volume":"17","author":"Sarigul Guduk","year":"2018","journal-title":"J Cosmet Dermatol"},{"key":"R33-20250228","doi-asserted-by":"crossref","first-page":"720","DOI":"10.1097\/DSS.0000000000000368","article-title":"Outcomes of polydioxanone knotless thread lifting for facial rejuvenation","volume":"41","author":"Suh","year":"2015","journal-title":"Dermatol Surg"},{"key":"R34-20250228","doi-asserted-by":"crossref","first-page":"227","DOI":"10.1080\/09546634.2019.1640347","article-title":"Experiences of barbed polydioxanone (PDO) cog thread for facial rejuvenation and our technique to prevent thread migration","volume":"32","author":"Unal","year":"2021","journal-title":"J Dermatolog Treat"},{"key":"R35-20250228","doi-asserted-by":"crossref","first-page":"1928","DOI":"10.1111\/jocd.13269","article-title":"Novel technique for infraorbital groove correction using multiple twisted polydioxanone thread","volume":"19","author":"Lee","year":"2020","journal-title":"J Cosmet Dermatol"},{"key":"R36-20250228","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1093\/asj\/sjx202","article-title":"Rejuvenating the face: an analysis of 100 absorbable suture suspension patients","volume":"38","author":"Ogilvie","year":"2018","journal-title":"Aesthet Surg J"},{"key":"R37-20250228","doi-asserted-by":"crossref","first-page":"1270","DOI":"10.3390\/polym13081270","article-title":"Synthesis of poly(l-lactide-co-\u03b5-caprolactone) copolymer: structure, toughness, and elasticity","volume":"13","author":"Zhang","year":"2021","journal-title":"Polymers (Basel)"},{"key":"R38-20250228","doi-asserted-by":"crossref","first-page":"997","DOI":"10.2147\/CCID.S359813","article-title":"Collagen stimulators in body applications: a review focused on poly-l-lactic acid (PLLA)","volume":"15","author":"Christen","year":"2022","journal-title":"Clin Cosmet Investig Dermatol"},{"key":"R39-20250228","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1111\/jocd.13371","article-title":"Stimulation of collagenesis by poly-L-lactic acid (PLLA) and -glycolide polymer (PLGA)-containing absorbable suspension suture and parallel sustained clinical benefit","volume":"19","author":"Goldberg","year":"2020","journal-title":"J Cosmet Dermatol"},{"key":"R40-20250228","doi-asserted-by":"crossref","first-page":"e4157","DOI":"10.1097\/GOX.0000000000004157","article-title":"Barbed PDO thread face lift: a case study of bacterial complication","volume":"10","author":"Surowiak","year":"2022","journal-title":"Plast Reconstr Surg Glob Open"},{"key":"R41-20250228","doi-asserted-by":"crossref","first-page":"498","DOI":"10.11622\/smedj.2020133","article-title":"Facial abscess from unlicensed thread lift","volume":"61","author":"Joethy","year":"2020","journal-title":"Singapore Med J"},{"key":"R42-20250228","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1093\/asj\/sjv079","article-title":"A comprehensive examination of topographic thickness of skin in the human face","volume":"35","author":"Chopra","year":"2015","journal-title":"Aesthet Surg J"},{"key":"R44-20250228","first-page":"253","article-title":"Dysesthesia and fasciculation: unusual complications following face-lift with cog threads","volume":"33","author":"Lee","year":"2007","journal-title":"Dermatol Surg"}],"container-title":["Dermatologic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/DSS.0000000000004466","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,2,28]],"date-time":"2025-02-28T13:09:15Z","timestamp":1740748155000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/DSS.0000000000004466"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,10,23]]},"references-count":41,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2025]]}},"URL":"https:\/\/doi.org\/10.1097\/dss.0000000000004466","relation":{},"ISSN":["1076-0512","1524-4725"],"issn-type":[{"value":"1076-0512","type":"print"},{"value":"1524-4725","type":"electronic"}],"subject":[],"published":{"date-parts":[[2024,10,23]]}}}