{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T19:59:32Z","timestamp":1790107172059,"version":"4.0.1"},"reference-count":18,"publisher":"Ovid Technologies (Wolters Kluwer Health)","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":["Dermatol Surg","DS"],"abstract":"<jats:sec>\n                    <jats:title>BACKGROUND<\/jats:title>\n                    <jats:p>Optimizing aesthetic results for soft tissue augmentation and skin resurfacing often requires multiple treatment modalities. How energy-based device (EBD) treatments alter properties of previously injected hyaluronic acid (HA) fillers is unknown.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>OBJECTIVE<\/jats:title>\n                    <jats:p>To evaluate whether elevated temperatures during EBD treatments alters key properties of HA fillers.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>MATERIALS AND METHODS<\/jats:title>\n                    <jats:p>Four HA fillers (Belotero Balance, Juv\u00e9derm Volbella, Juv\u00e9derm Ultra XC, and Restylane Eyelight) were heated to 65 or 100\u00b0C to simulate temperatures of nonablative lasers or ablative lasers, respectively, or kept at room temperature. The authors assessed storage modulus (G\u2032), loss modulus (G\u2033), cohesivity, and water absorption.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>RESULTS<\/jats:title>\n                    <jats:p>No significant changes were observed in G\u2032 and G\u2033, except for increases in G\u2032 for Juv\u00e9derm Ultra XC at 100\u00b0C (16.67 Pa, \u0394 = +11%) and Juv\u00e9derm Volbella at 100\u00b0C (92.67 Pa, \u0394 = +49%). Cohesivity was stable with only minor increases (&lt;0.8 points on a 1\u20135 scale) for Juv\u00e9derm Ultra XC and Belotero Balance at 65\u00b0C. Water absorption remained consistent across all HA fillers and temperature conditions.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>CONCLUSION<\/jats:title>\n                    <jats:p>Overall, in vitro heat exposure of tested HA fillers does not alter rheologic and physicochemical properties. These findings suggest that EBDs over preinjected HA fillers are unlikely to compromise filler integrity. Further in vivo validation is necessary.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/dss.0000000000005285","type":"journal-article","created":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T15:00:10Z","timestamp":1785423610000},"update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":0,"title":["Characterizing Major In Vitro Rheologic and Physicochemical Properties of Thermally Altered Hyaluronic Acid Fillers"],"prefix":"10.1097","author":[{"given":"Michael S.","family":"Chang","sequence":"first","affiliation":[{"name":"Harvard Medical School, Boston, Massachusetts;"},{"name":"Dermatology Section, Veterans Affairs Boston Healthcare System, Jamaica Plain, Massachusetts;"},{"name":"Department of Dermatology, Beth Israel Deaconess Medical Center, Boston, Massachusetts;"},{"name":"Department of Dermatology, Brigham and Women's Hospital, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Benjamin","family":"Thorne","sequence":"additional","affiliation":[{"name":"School of Engineering and Applied Science, Harvard University, Cambridge, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hye Jin","family":"Chung","sequence":"additional","affiliation":[{"name":"Harvard Medical School, Boston, Massachusetts;"},{"name":"Department of Dermatology, Beth Israel Deaconess Medical Center, Boston, Massachusetts;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Erin","family":"Theisen","sequence":"additional","affiliation":[{"name":"Harvard Medical School, Boston, Massachusetts;"},{"name":"Department of Dermatology, Brigham and Women's Hospital, Boston, Massachusetts;"},{"name":"Division of Rheumatology, Inflammation, and Immunity, Brigham and Women's Hospital, Boston, Massachusetts"}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","published-online":{"date-parts":[[2026,7,30]]},"reference":[{"key":"R1-20260922","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1055\/s-0032-1329414","article-title":"Fractional carbon dioxide laser resurfacing","volume":"26","author":"Ramsdell","year":"2012","journal-title":"Semin Plast Surg"},{"key":"R2-20260922","doi-asserted-by":"crossref","first-page":"719","DOI":"10.1016\/j.jaad.2008.01.003","article-title":"The spectrum of laser skin resurfacing: nonablative, fractional, and ablative laser resurfacing","volume":"58","author":"Alexiades-Armenakas","year":"2008","journal-title":"J Am Acad Dermatol"},{"key":"R3-20260922","doi-asserted-by":"crossref","first-page":"552","DOI":"10.1097\/DSS.0000000000001716","article-title":"Histologic effects of fractional laser and radiofrequency devices on hyaluronic acid filler","volume":"45","author":"Hsu","year":"2019","journal-title":"Dermatol Surg"},{"key":"R4-20260922","doi-asserted-by":"crossref","first-page":"205","DOI":"10.1002\/lsm.20241","article-title":"Safety of radiofrequency treatment over human skin previously injected with medium-term injectable soft-tissue augmentation materials: a controlled pilot trial","volume":"38","author":"Alam","year":"2006","journal-title":"Lasers Surg Med"},{"key":"R5-20260922","doi-asserted-by":"crossref","first-page":"356","DOI":"10.1002\/lsm.20253","article-title":"Effects of monopolar radiofrequency treatment over soft-tissue fillers in an animal model","volume":"37","author":"England","year":"2005","journal-title":"Lasers Surg Med"},{"key":"R6-20260922","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1111\/jocd.15498","article-title":"The effect of combined of hyaluronic acid dermal filler and microfocused ultrasound treatment: a clinicopathological study","volume":"22","author":"Vachiramon","year":"2023","journal-title":"J Cosmet Dermatol"},{"key":"R7-20260922","doi-asserted-by":"crossref","first-page":"798","DOI":"10.1111\/jocd.15509","article-title":"The effect of combined hyaluronic acid filler injection and radiofrequency treatment: a clinic histological analysis","volume":"22","author":"Jurairattanaporn","year":"2023","journal-title":"J Cosmet Dermatol"},{"key":"R8-20260922","doi-asserted-by":"crossref","first-page":"678","DOI":"10.1097\/PRS.0000000000001638","article-title":"Cohesivity of hyaluronic acid fillers: development and clinical implications of a novel assay, pilot validation with a five-point grading scale, and evaluation of six U.S. food and Drug administration-approved fillers","volume":"136","author":"Sundaram","year":"2015","journal-title":"Plast Reconstr Surg"},{"key":"R9-20260922","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1097\/DSS.0000000000003108","article-title":"Comparing water absorption of Food and Drug Administration-approved hyaluronic acid fillers","volume":"47","author":"Woodward","year":"2021","journal-title":"Dermatol Surg"},{"key":"R10-20260922","first-page":"127","article-title":"Rheological properties of cross-linked hyaluronic acid dermal fillers","volume":"9","author":"Santoro","year":"2011","journal-title":"J Appl Biomater Biomech"},{"issue":"suppl 1","key":"R11-20260922","doi-asserted-by":"crossref","first-page":"S373","DOI":"10.1097\/DSS.0000000000000536","article-title":"Rheological properties and in vivo performance characteristics of soft tissue fillers","volume":"41","author":"Hee","year":"2015","journal-title":"Dermatol Surg"},{"key":"R12-20260922","doi-asserted-by":"crossref","first-page":"e13395","DOI":"10.1111\/srt.13395","article-title":"Connections between cohesion and properties that related to safety and effectiveness of the hyaluronic acid dermal fillers: a comparative study of the cohesive and non-cohesive gels","volume":"29","author":"Wang","year":"2023","journal-title":"Skin Res Technol"},{"key":"R13-20260922","first-page":"948","article-title":"Rheological properties of several hyaluronic acid-based gels: a comparative study","volume":"17","author":"Micheels","year":"2018","journal-title":"J Drugs Dermatol"},{"key":"R14-20260922","doi-asserted-by":"crossref","first-page":"10518","DOI":"10.3390\/ijms231810518","article-title":"The rheology and physicochemical characteristics of hyaluronic acid fillers: their clinical implications","volume":"23","author":"Fundar\u00f2","year":"2022","journal-title":"Int J Mol Sci"},{"key":"R15-20260922","doi-asserted-by":"crossref","first-page":"707e","DOI":"10.1097\/PRS.0000000000005429","article-title":"Rheologic and physicochemical properties used to differentiate injectable hyaluronic acid filler products","volume":"143","author":"Fagien","year":"2019","journal-title":"Plast Reconstr Surg"},{"key":"R16-20260922","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1097\/DSS.0000000000001370","article-title":"Cohesion of hyaluronic acid fillers: correlation between cohesion and other physicochemical properties","volume":"44","author":"Edsman","year":"2018","journal-title":"Dermatol Surg"},{"key":"R17-20260922","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1055\/a-2234-1019","article-title":"\u201cCohesiveness of hyaluronic acid fillers\u201d: evaluation using multiple cohesion tests","volume":"51","author":"Kim","year":"2024","journal-title":"Arch Plast Surg"},{"key":"R18-20260922","doi-asserted-by":"crossref","first-page":"17","DOI":"10.20517\/2347-9264.2018.10","article-title":"Key rheological properties of hyaluronic acid fillers: from tissue integration to product degradation","volume":"5","author":"Gavard","year":"2018","journal-title":"Plast Aesthet Res"}],"container-title":["Dermatologic Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/www.ovid.com\/10.1097\/DSS.0000000000005285","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2026,9,22]],"date-time":"2026-09-22T19:00:23Z","timestamp":1790103623000},"score":1,"resource":{"primary":{"URL":"https:\/\/www.ovid.com\/10.1097\/DSS.0000000000005285"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,7,30]]},"references-count":18,"URL":"https:\/\/doi.org\/10.1097\/dss.0000000000005285","relation":{},"ISSN":["1076-0512","1524-4725"],"issn-type":[{"value":"1076-0512","type":"print"},{"value":"1524-4725","type":"electronic"}],"subject":[],"published":{"date-parts":[[2026,7,30]]}}}