{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,22]],"date-time":"2026-07-22T23:27:04Z","timestamp":1784762824491,"version":"3.55.0"},"reference-count":19,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"5","content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":[],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1097\/eja.0000000000000779","type":"journal-article","created":{"date-parts":[[2018,1,25]],"date-time":"2018-01-25T15:55:59Z","timestamp":1516895759000},"page":"390-397","source":"Crossref","is-referenced-by-count":13,"title":["Comparison of double intravenous vasopressor automated system using nexfin versus manual vasopressor bolus administration for maintenance of haemodynamic stability during spinal anaesthesia for caesarean delivery"],"prefix":"10.1097","volume":"35","author":[{"given":"Ban Leong","family":"Sng","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wei","family":"Du","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Man Xin","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Farida","family":"Ithnin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Deepak","family":"Mathur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wan Ling","family":"Leong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rehena","family":"Sultana","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nian-Lin R.","family":"Han","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alex Tiong Heng","family":"Sia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-10-20210207","first-page":"62","article-title":"Maternal hypotension during spinal anaesthesia for caesarean delivery","volume":"79","author":"Mercier","year":"2013","journal-title":"Minerva Anestesiol"},{"key":"R2-10-20210207","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1213\/ANE.0b013e3181ea5f77","article-title":"Spinal anesthesia during elective cesarean delivery: closer to a solution","volume":"111","author":"Dyer","year":"2010","journal-title":"Anesth Analg"},{"key":"R3-10-20210207","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1097\/01.aco.0000192816.22989.ba","article-title":"Vasopressors in obstetrics: what should we be using?","volume":"19","author":"Ngan Kee","year":"2006","journal-title":"Curr Opin Anaesthesiol"},{"key":"R4-10-20210207","doi-asserted-by":"crossref","first-page":"56.e1","DOI":"10.1016\/j.ajog.2009.07.012","article-title":"Maternal hypotension during elective cesarean section and short-term neonatal outcome","volume":"202","author":"Maayan-Metzger","year":"2010","journal-title":"Am J Obstet Gynecol"},{"key":"R5-10-20210207","doi-asserted-by":"crossref","first-page":"810","DOI":"10.1111\/j.1399-6576.2011.02646.x","article-title":"Vasopressors for the management of hypotension after spinal anaesthesia for elective caesarean section. Systematic review and cumulative meta-analysis","volume":"56","author":"Veeser","year":"2012","journal-title":"Acta Anaesthesiol Scand"},{"key":"R7-10-20210207","doi-asserted-by":"crossref","first-page":"1348","DOI":"10.1111\/anae.12000","article-title":"Closed-loop double-vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: a preliminary study","volume":"67","author":"Sia","year":"2012","journal-title":"Anaesthesia"},{"key":"R8-10-20210207","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1111\/anae.12460","article-title":"Closed-loop double-vasopressor automated system vs manual bolus vasopressor to treat hypotension during spinal anaesthesia for caesarean section: a randomised controlled trial","volume":"69","author":"Sng","year":"2014","journal-title":"Anaesthesia"},{"key":"R9-10-20210207","doi-asserted-by":"crossref","first-page":"691","DOI":"10.1111\/anae.13008","article-title":"Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section","volume":"70","author":"Sng","year":"2015","journal-title":"Anaesthesia"},{"key":"R10-10-20210207","doi-asserted-by":"crossref","first-page":"605","DOI":"10.1016\/S0008-6363(98)00067-4","article-title":"Fifteen years experience with finger arterial pressure monitoring: Assessment of the technology","volume":"38","author":"Imholz","year":"1998","journal-title":"Cardiovasc Res"},{"key":"R11-10-20210207","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.1097\/ALN.0b013e31824f94ed","article-title":"Noninvasive continuous arterial blood pressure monitoring with Nexfin\u00ae","volume":"116","author":"Martina","year":"2012","journal-title":"Anesthesiology"},{"key":"R12-10-20210207","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1111\/j.1365-2044.2011.07018.x","article-title":"A comparison of the Nexfin(R) and transcardiopulmonary thermodilution to estimate cardiac output during coronary artery surgery","volume":"67","author":"Broch","year":"2012","journal-title":"Anaesthesia"},{"key":"R13-10-20210207","doi-asserted-by":"crossref","first-page":"1343","DOI":"10.1213\/ANE.0b013e31826ac3db","article-title":"Phenylephrine infusion versus bolus regimens during cesarean delivery under spinal anesthesia: a double-blind randomized clinical trial to assess hemodynamic changes","volume":"115","author":"Doherty","year":"2012","journal-title":"Anesth Analg"},{"key":"R14-10-20210207","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1097\/ALN.0b013e3181b437e0","article-title":"Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery","volume":"111","author":"Dyer","year":"2009","journal-title":"Anesthesiology"},{"key":"R15-10-20210207","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1093\/bja\/aes339","article-title":"Randomized comparison of closed-loop feedback computer-controlled with manual-controlled infusion of phenylephrine for maintaining arterial pressure during spinal anaesthesia for caesarean delivery","volume":"110","author":"Ngan Kee","year":"2013","journal-title":"Br J Anaesth"},{"key":"R16-10-20210207","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1007\/BF01143186","article-title":"Measuring the predictive performance of computer-controlled infusion pumps","volume":"20","author":"Varvel","year":"1992","journal-title":"J Pharmacokinet Biopharm"},{"key":"R17-10-20210207","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1111\/j.1365-2044.2007.05257.x","article-title":"Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study","volume":"62","author":"Ngan Kee","year":"2007","journal-title":"Anaesthesia"},{"key":"R18-10-20210207","doi-asserted-by":"crossref","first-page":"744","DOI":"10.1097\/00000542-200510000-00012","article-title":"Prevention of hypotension during spinal anesthesia for cesarean delivery: an effective technique using combination phenylephrine infusion and crystalloid cohydration","volume":"103","author":"Ngan Kee","year":"2005","journal-title":"Anesthesiology"},{"key":"R19-10-20210207","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1213\/ANE.0000000000001974","article-title":"Closed-loop feedback computer-controlled phenylephrine for maintenance of blood pressure during spinal anesthesia for cesarean delivery: a randomized trial comparing automated boluses versus infusion","volume":"125","author":"Ngan Kee","year":"2017","journal-title":"Anesth Analg"},{"key":"R20-10-20210207","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1016\/S0034-7094(10)70048-9","article-title":"Phenylephrine for blood pressure control in elective cesarean section: therapeutic versus prophylactic doses","volume":"60","author":"das Neves","year":"2010","journal-title":"Rev Bras Anestesiol"}],"container-title":["European Journal of Anaesthesiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/EJA.0000000000000779","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,14]],"date-time":"2021-05-14T00:46:51Z","timestamp":1620953211000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/00003643-201805000-00010"}},"subtitle":["A randomised double-blind controlled trial"],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":19,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018]]}},"URL":"https:\/\/doi.org\/10.1097\/eja.0000000000000779","relation":{},"ISSN":["0265-0215"],"issn-type":[{"value":"0265-0215","type":"print"}],"subject":[],"published":{"date-parts":[[2018,5]]}}}