{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T07:25:44Z","timestamp":1777965944997,"version":"3.51.4"},"reference-count":23,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:sec>\n            <jats:title>Background:<\/jats:title>\n            <jats:p>Dried blood spots (DBSs) have gained recent popularity as a sampling method for therapeutic drug monitoring. For patients, DBS sampling has several advantages over venous blood sampling. However, technical issues primarily influenced by hematocrit levels, interfere with the implementation of this method in daily clinical practice. The results of concentration measurements of drugs that are influenced by hematocrit should be corrected for hematocrit levels. In this article, we developed a fast, nondestructive, near-infrared (NIR)-based method for measuring the hematocrit in DBSs.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Method:<\/jats:title>\n            <jats:p>Using a partial least squares algorithm, an NIR-based quantification method was developed for measuring hematocrit levels of 0.19\u20130.49 L\/L. Residual venous blood of 522 patients was used to build this partial least squares model. The validity of the method was evaluated using 40 patient samples. DBSs were created by adding a small amount (50 \u00b5L) of blood on a Whatman filter paper and drying for 24 hours in a desiccator cabinet. The robustness was evaluated by measuring 24 additional samples with a high hemolysis, icterus, and lipemia (HIL) index. The hematocrit values obtained using a Sysmex XN hemocytometry analyzer were used as reference.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Results:<\/jats:title>\n            <jats:p>The difference between hematocrit measurements obtained with NIR spectroscopy and a hemocytometry analyzer was &lt;15% for the 40 samples. The accuracy (\u22649%) and precision (\u22647%) for all the quality control samples were within the acceptance criteria of &lt;15%. The intraassay and interassay coefficient of variability was \u22643% and \u22646%, respectively, for the different quality control levels. There were no deviations in the measurements for the samples with high HIL indices. The stability of hematocrit in DBS was up to 14 days for all levels.<\/jats:p>\n          <\/jats:sec>\n          <jats:sec>\n            <jats:title>Conclusions:<\/jats:title>\n            <jats:p>We developed and validated a hematocrit model using NIR spectroscopy. This nondestructive, accurate, and reproducible method has a short analysis time (51 seconds), and can be used to analyze DBS samples stored for up to 2 weeks in a desiccator cabinet.<\/jats:p>\n          <\/jats:sec>","DOI":"10.1097\/ftd.0000000000000834","type":"journal-article","created":{"date-parts":[[2020,11,9]],"date-time":"2020-11-09T05:00:35Z","timestamp":1604898035000},"page":"351-357","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":26,"title":["Development and Validation of Hematocrit Level Measurement in Dried Blood Spots Using Near-Infrared Spectroscopy"],"prefix":"10.1097","volume":"43","author":[{"given":"Daan","family":"van de Velde","sequence":"first","affiliation":[{"name":"Department of Hospital Pharmacy, Erasmus MC;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jordy L.","family":"van der Graaf","sequence":"additional","affiliation":[{"name":"Department of Hospital Pharmacy, Erasmus MC;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mariam","family":"Boussaidi","sequence":"additional","affiliation":[{"name":"Department of Hospital Pharmacy, Erasmus MC;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ruud","family":"Huisman","sequence":"additional","affiliation":[{"name":"Department of Hospital Pharmacy, Erasmus MC;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dennis A.","family":"Hesselink","sequence":"additional","affiliation":[{"name":"Department of Internal Medicine, Division of Nephrology and Transplantation, Erasmus MC ;"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Henk","family":"Russcher","sequence":"additional","affiliation":[{"name":"Department of Clinical Chemistry, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands; and"}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Annelies C.","family":"Kooij-Egas","sequence":"additional","affiliation":[{"name":"Department of Hospital Pharmacy, University Medical Center Utrecht, Utrecht, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Erik","family":"van Maarseveen","sequence":"additional","affiliation":[{"name":"Department of Hospital Pharmacy, University Medical Center Utrecht, Utrecht, the Netherlands."}],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Brenda C.M.","family":"de Winter","sequence":"additional","affiliation":[{"name":"Department of Hospital Pharmacy, Erasmus MC;"}],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"276","reference":[{"key":"R1-20250603","doi-asserted-by":"crossref","first-page":"2889","DOI":"10.1111\/bcp.13755","article-title":"Therapeutic drug monitoring of tacrolimus and mycophenolic acid in outpatient renal transplant recipients using a volumetric dried blood spot sampling device","volume":"84","author":"Zwart","year":"2018","journal-title":"Br J Clin Pharmacol."},{"key":"R2-20250603","doi-asserted-by":"crossref","first-page":"54","DOI":"10.1016\/j.jchromb.2013.02.035","article-title":"Analysis of tacrolimus and creatinine from a single dried blood spot using liquid chromatography tandem mass spectrometry","volume":"926","author":"Koop","year":"2013","journal-title":"J Chromatogr B Analyt Technol Biomed Life Sci."},{"key":"R3-20250603","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/FTD.0000000000000643","article-title":"Official international association for therapeutic drug monitoring and clinical toxicology guideline: development and validation of dried blood spot-based methods for therapeutic drug monitoring","volume":"41","author":"Capiau","year":"2019","journal-title":"Ther Drug Monit."},{"key":"R4-20250603","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/j.talanta.2013.04.027","article-title":"Fast LC-MS\/MS analysis of tacrolimus, sirolimus, everolimus and cyclosporin A in dried blood spots and the influence of the hematocrit and immunosuppressant concentration on recovery","volume":"115","author":"Koster","year":"2013","journal-title":"Talanta."},{"key":"R5-20250603","doi-asserted-by":"crossref","first-page":"412","DOI":"10.1097\/FTD.0000000000000422","article-title":"Dried blood spot sampling for tacrolimus and mycophenolic acid in children: analytical and clinical validation","volume":"39","author":"Martial","year":"2017","journal-title":"Ther Drug Monit."},{"key":"R6-20250603","doi-asserted-by":"crossref","first-page":"344","DOI":"10.1097\/FTD.0000000000000502","article-title":"Dried blood spot analysis for therapeutic drug monitoring of antipsychotics: drawbacks of its clinical application","volume":"40","author":"Kloosterboer","year":"2018","journal-title":"Ther Drug Monit."},{"key":"R7-20250603","doi-asserted-by":"crossref","first-page":"6749","DOI":"10.1007\/s00216-014-8114-z","article-title":"Potassium-based algorithm allows correction for the hematocrit bias in quantitative analysis of caffeine and its major metabolite in dried blood spots","volume":"406","author":"De Kesel","year":"2014","journal-title":"Anal Bioanal Chem."},{"key":"R8-20250603","doi-asserted-by":"crossref","first-page":"653","DOI":"10.4155\/bio.14.310","article-title":"A device for dried blood microsampling in quantitative bioanalysis: overcoming the issues associated blood hematocrit","volume":"7","author":"Spooner","year":"2015","journal-title":"Bioanalysis."},{"key":"R9-20250603","doi-asserted-by":"crossref","first-page":"3315","DOI":"10.1007\/s00216-018-0993-y","article-title":"Precise, accurate and user-independent blood collection system for dried blood spot sample preparation","volume":"410","author":"Neto","year":"2018","journal-title":"Anal Bioanal Chem."},{"key":"R10-20250603","doi-asserted-by":"crossref","first-page":"2068","DOI":"10.1021\/ac503931g","article-title":"New microfluidic-based sampling procedure for overcoming the hematocrit problem associated with dried blood spot analysis","volume":"87","author":"Leuthold","year":"2015","journal-title":"Anal Chem."},{"key":"R11-20250603","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1021\/ac303014b","article-title":"Prediction of the hematocrit of dried blood spots via potassium measurement on a routine clinical chemistry analyzer","volume":"85","author":"Capiau","year":"2013","journal-title":"Anal Chem."},{"key":"R12-20250603","doi-asserted-by":"crossref","first-page":"6538","DOI":"10.1021\/acs.analchem.6b01321","article-title":"A novel, nondestructive, dried blood spot-based hematocrit prediction method using noncontact diffuse reflectance spectroscopy","volume":"88","author":"Capiau","year":"2016","journal-title":"Anal Chem."},{"key":"R13-20250603","doi-asserted-by":"crossref","DOI":"10.4172\/2155-9872.1000162","article-title":"An on-card approach for assessment of hematocrit on dried blood spots which allows for correction of sample volume","volume":"4","author":"Miller","year":"2013","journal-title":"J Anal Bioanal Tech."},{"key":"R14-20250603","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1177\/0004563216643557","article-title":"Serum indices: managing assay interference","volume":"53","author":"Farrell","year":"2016","journal-title":"Ann Clin Biochem."},{"key":"R15-20250603","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1111\/ijlh.12498","article-title":"Effects of haemolysis, icterus and lipaemia on coagulation tests as performed on stago STA-Compact-Max analyser","volume":"38","author":"Woolley","year":"2016","journal-title":"Int J Lab Hematol."},{"key":"R16-20250603","doi-asserted-by":"crossref","first-page":"307","DOI":"10.3343\/alm.2014.34.4.307","article-title":"Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results","volume":"34","author":"Shin","year":"2014","journal-title":"Ann Lab Med."},{"key":"R17-20250603","doi-asserted-by":"crossref","first-page":"e22229","DOI":"10.1002\/jcla.22229","article-title":"Icteric human samples: icterus index and method of estimating an interference-free value for 16 biochemical analyses","volume":"32","author":"Nicolay","year":"2018","journal-title":"J Clin Lab Anal."},{"key":"R18-20250603","doi-asserted-by":"crossref","first-page":"57","DOI":"10.11613\/BM.2014.008","article-title":"Lipemia: causes, interference mechanisms, detection and management","volume":"24","author":"Nikolac","year":"2014","journal-title":"Biochem Med."},{"key":"R21-20250603","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/j.aca.2010.03.048","article-title":"Variables selection methods in near-infrared spectroscopy","volume":"667","author":"Xiaobo","year":"2010","journal-title":"Anal Chim Acta"},{"key":"R24-20250603","doi-asserted-by":"crossref","first-page":"056004","DOI":"10.1117\/1.JBO.19.5.056004","article-title":"Deep optical imaging of tissue using the second and third near-infrared spectral windows","volume":"19","author":"Sordillo","year":"2014","journal-title":"J Biomed Opt."},{"key":"R25-20250603","doi-asserted-by":"crossref","first-page":"41128","DOI":"10.1117\/1.2342076","article-title":"Prediction of glucose in whole blood by near-infrared spectroscopy: influence of wavelength region, preprocessing, and hemoglobin concentration","volume":"11","author":"Kim","year":"2006","journal-title":"J Biomed Opt."},{"key":"R26-20250603","first-page":"57","article-title":"New insights into evaluation of regression models through a decomposition of the prediction errors: application to near-infrared spectral data","volume":"37","author":"S\u00e1nchez-Rodr\u00edguez","year":"2013"},{"key":"R27-20250603","doi-asserted-by":"crossref","first-page":"1534","DOI":"10.1373\/clinchem.2016.263053","article-title":"Measurement of hematocrit in dried blood spots using near-infrared spectroscopy: robust, fast, and nondestructive","volume":"62","author":"Oostendorp","year":"2016","journal-title":"Clin Chem."}],"container-title":["Therapeutic Drug Monitoring"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/FTD.0000000000000834","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,3]],"date-time":"2025-06-03T17:17:56Z","timestamp":1748971076000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/FTD.0000000000000834"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":23,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/ftd.0000000000000834","relation":{},"ISSN":["0163-4356"],"issn-type":[{"value":"0163-4356","type":"print"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"2020-08-01","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2020-10-05","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}