{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,4]],"date-time":"2026-09-04T20:34:37Z","timestamp":1788554077380,"version":"build-2803163510"},"reference-count":21,"publisher":"Ovid Technologies (Wolters Kluwer Health)","issue":"3","content-domain":{"domain":["lww.com","ovid.com"],"crossmark-restriction":true},"short-container-title":[],"published-print":{"date-parts":[[2021,6]]},"abstract":"<jats:sec>\n                    <jats:title>Background:<\/jats:title>\n                    <jats:p>Drug concentrations of antiepileptic drugs (AEDs) are routinely determined from blood serum or plasma at trough levels (before intake of morning dose). In capillary blood collection, blood is taken from the fingertip with the aid of a disposable tool and dried on absorbent material. The volumetric absorptive microsampling technique offers several advantages over the use of filter paper cards. The aim of this study was to determine conversion factors for the estimation of AED serum concentrations from capillary blood concentrations.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Methods:<\/jats:title>\n                    <jats:p>Venous and capillary blood samples were collected from adult inpatients with epilepsy who were treated with lacosamide (LCM, n = 30), lamotrigine (LTG, n = 40), and\/or levetiracetam (LEV, n = 36). A validated liquid chromatography-mass spectrometry (LC-MS) method for dried blood samples for these AEDs was compared with routine serum laboratory methods. Method agreement was evaluated using different regression techniques, and the conversion factors were calculated.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Results:<\/jats:title>\n                    <jats:p>\n                      Regression analyses revealed a linear relationship between serum and capillary blood concentrations for all 3 AEDs (\n                      <jats:italic toggle=\"yes\">r<\/jats:italic>\n                      \u2265 0.95). For LTG, the regression intercept was significantly different from 0, indicating that the relationship was linear, but not necessarily proportional. Although LEV and LCM concentrations tended to be lower in capillary blood than in serum (mean ratio of serum concentration to capillary blood concentration: 1.14 and 1.22, respectively), LTG concentrations were higher in capillary blood (mean ratio = 0.85).\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>Conclusions:<\/jats:title>\n                    <jats:p>The estimation of serum concentrations from measured capillary blood concentrations is feasible for LCM, LTG, and LEV. A simple ratio approach using the mean ratio and Passing\u2013Bablok regression showed the best results for all 3 AEDs. The volumetric absorptive microsampling technique facilitates the quantitative sample collection of capillary blood and overcomes the drawbacks associated with the classical dried blood spot technique.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1097\/ftd.0000000000000890","type":"journal-article","created":{"date-parts":[[2021,4,14]],"date-time":"2021-04-14T23:59:20Z","timestamp":1618444760000},"page":"394-400","update-policy":"https:\/\/doi.org\/10.1097\/lww.0000000000001000","source":"Crossref","is-referenced-by-count":12,"title":["Therapeutic Drug Monitoring of Lamotrigine, Lacosamide, and Levetiracetam in Dried Capillary Blood\u2014Determination of Conversion Factors for Serum-Based Reference Ranges"],"prefix":"10.1097","volume":"43","author":[{"given":"Dennis","family":"Klimpel","sequence":"first","affiliation":[{"name":"MVZ Labor Krone GbR, Bad Salzuflen;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anne","family":"Hagemann","sequence":"additional","affiliation":[{"name":"Society for Epilepsy Research; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian G.","family":"Bien","sequence":"additional","affiliation":[{"name":"Society for Epilepsy Research; and"},{"name":"Bethel Epilepsy Center, Mara Hospital, Bielefeld, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bertin","family":"Dufaux","sequence":"additional","affiliation":[{"name":"MVZ Labor Krone GbR, Bad Salzuflen;"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theodor W.","family":"May","sequence":"additional","affiliation":[{"name":"Society for Epilepsy Research; and"}],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Brandt","sequence":"additional","affiliation":[{"name":"Bethel Epilepsy Center, Mara Hospital, Bielefeld, Germany."}],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"276","reference":[{"key":"R1-20250603","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1097\/FTD.0000000000000623","article-title":"Pharmacodynamic monitoring of antiepileptic drug therapy","volume":"41","author":"Brandt","year":"2019","journal-title":"Ther Drug Monit."},{"key":"R2-20250603","first-page":"161","article-title":"Therapeutic drug monitoring of newer antiepileptic drugs","volume":"35","author":"Brandt","year":"2011","journal-title":"J Lab Med."},{"key":"R3-20250603","doi-asserted-by":"crossref","first-page":"1239","DOI":"10.1111\/j.1528-1167.2008.01561.x","article-title":"Antiepileptic drugs-best practice guidelines for therapeutic drug monitoring: a position paper by the subcommission on therapeutic drug monitoring, ILAE commission on therapeutic strategies","volume":"49","author":"Patsalos","year":"2008","journal-title":"Epilepsia"},{"key":"R4-20250603","doi-asserted-by":"crossref","first-page":"2331","DOI":"10.1007\/s00216-018-0866-4","article-title":"Volumetric absortive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs","volume":"410","author":"Velghe","year":"2018","journal-title":"Anal Bioanal Chem."},{"key":"R5-20250603","doi-asserted-by":"crossref","first-page":"338","DOI":"10.1542\/peds.32.3.338","article-title":"A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants","volume":"32","author":"Guthrie","year":"1963","journal-title":"Pediatrics"},{"key":"R6-20250603","doi-asserted-by":"crossref","first-page":"288","DOI":"10.1016\/j.jpba.2017.07.029","article-title":"Volumetric microsampling: current advantages and applications","volume":"147","author":"Kok","year":"2018","journal-title":"J Pharm Biomed Anal."},{"key":"R7-20250603","doi-asserted-by":"crossref","first-page":"681","DOI":"10.1097\/FTD.0000000000000652","article-title":"Volumetric absortive microsampling: a new sampling tool for therapeutic drug monitoring of antiepileptic drugs","volume":"41","author":"D\u00b4Urso","year":"2019","journal-title":"Ther Drug Monit."},{"key":"R9-20250603","first-page":"238","article-title":"Lamotrigine in dried blood spots by HPLC","volume":"31","author":"Soons","year":"2006","journal-title":"Ned Tijdschr Klin Chem Labgeneesk"},{"key":"R10-20250603","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1016\/j.clinbiochem.2016.12.008","article-title":"Comparison between dried blood spot and plasma sampling for therapeutic drug monitoring of antiepileptic drugs in children with epilepsy: a step towards home sampling","volume":"50","author":"Linder","year":"2017","journal-title":"Clin Biochem."},{"key":"R11-20250603","first-page":"185","article-title":"Appendix B to the GTFCh guidelines for quality assurance in forensic-toxicologic analysis: requirements for the validation of analytical methods","volume":"76","author":"Peters","year":"2009","journal-title":"Toxichem Krimtech"},{"key":"R12-20250603","first-page":"A1583","article-title":"Richtlinie der Bundes\u00e4rztekammer zur Qualit\u00e4tssicherung laboratoriumsmedizinischer Untersuchungen [in German]","volume":"111","year":"2014","journal-title":"Deutsches \u00c4rzteblatt."},{"key":"R13-20250603","first-page":"709","article-title":"A new biometrical procedure for testing the equality of measurements from two different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry, part I","volume":"21","author":"Passing","year":"1983","journal-title":"J Clin Chem Clin Biochem."},{"key":"R16-20250603","doi-asserted-by":"crossref","first-page":"124","DOI":"10.20982\/tqmp.10.2.p124","article-title":"Sample size estimation for correlations with pre-specified confidence interval","volume":"10","author":"Moinester","year":"2014","journal-title":"Quant Methods Psychol."},{"key":"R18-20250603","doi-asserted-by":"crossref","first-page":"1287","DOI":"10.2307\/1911963","article-title":"A simple test for heteroscedasticity and random coefficient variation","volume":"47","author":"Breusch","year":"1979","journal-title":"Econometrica."},{"key":"R19-20250603","doi-asserted-by":"crossref","first-page":"409","DOI":"10.1097\/FTD.0000000000000643","article-title":"Official international association for therapeutic drug monitoring and clinical toxicology guideline: development and validation of dried blood spot-based methods for therapeutic drug monitoring","volume":"41","author":"Capiau","year":"2019","journal-title":"Ther Drug Monit."},{"key":"R20-20250603","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1111\/bcpt.13269","article-title":"Development and clinical applications of the dried blood spot method for therapeutic drug monitoring of anti-epileptic drugs","volume":"125","author":"Min","year":"2019","journal-title":"Basic Clin Pharmacol Toxicol."},{"key":"R21-20250603","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.jchromb.2017.11.005","article-title":"Carbamazepine, lamotrigine, levetiracetam and valproic acid in dried blood spots with liquid chromatography tandem mass spectrometry; method development and validation","volume":"1072","author":"Linder","year":"2018","journal-title":"J Chromatogr B Analyt Technol Biomed Life Sci."},{"key":"R22-20250603","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1111\/j.1423-0410.2007.00978.x","article-title":"Use of capillary blood count parameters in adults","volume":"93","author":"Schalk","year":"2007","journal-title":"Vox Sang"},{"key":"R23-20250603","doi-asserted-by":"crossref","first-page":"653","DOI":"10.4155\/bio.14.310","article-title":"A device for dried blood microsampling in quantitative bioanalysis; overcoming the issues associated blood hematocrit","volume":"7","author":"Spooner","year":"2015","journal-title":"Bioanalysis"},{"key":"R24-20250603","doi-asserted-by":"crossref","first-page":"8489","DOI":"10.1021\/ac5022562","article-title":"Volumetric absortive microsampling: a dried sample collection technique for quantitative bioanalysis","volume":"86","author":"Denniff","year":"2014","journal-title":"Anal Chem."},{"key":"R25-20250603","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1097\/FTD.0000000000000605","article-title":"Dried blood spot self-sampling by guardians of children with epilepsy is feasible: comparison with plasma for multiple antieplileptic drugs","volume":"41","author":"Linder","year":"2019","journal-title":"Ther Drug Monit."}],"container-title":["Therapeutic Drug Monitoring"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/journals.lww.com\/10.1097\/FTD.0000000000000890","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,3]],"date-time":"2025-06-03T13:19:09Z","timestamp":1748956749000},"score":1,"resource":{"primary":{"URL":"https:\/\/journals.lww.com\/10.1097\/FTD.0000000000000890"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,6]]},"references-count":21,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021]]}},"URL":"https:\/\/doi.org\/10.1097\/ftd.0000000000000890","relation":{},"ISSN":["0163-4356"],"issn-type":[{"value":"0163-4356","type":"print"}],"subject":[],"published":{"date-parts":[[2021,6]]},"assertion":[{"value":"2020-11-06","name":"received","label":"Received","group":{"name":"publication_history","label":"Publication History"}},{"value":"2021-02-19","name":"accepted","label":"Accepted","group":{"name":"publication_history","label":"Publication History"}}]}}